Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Open accessThe DOI matches its Crossref record; 121 of the 121 references it cites were found in a registry or an index.
Abstract
The volume of interstitial fluid (ISF) in the human body is three times that of blood. Yet, collecting diagnostically useful ISF is more challenging than collecting blood because the extraction of dermal ISF disrupts the delicate balance of pressure between ISF, blood and lymph, and because the triggered local inflammation further skews the concentrations of many analytes in the extracted fluid. In this Perspective, we overview the most meaningful differences in the make-up of ISF and blood, and discuss why ISF cannot be viewed generally as a diagnostically useful proxy for blood. We also argue that continuous sensing of small-molecule analytes in dermal ISF via rapid assays compatible with nanolitre sample volumes or via miniaturized sensors inserted into the dermis can offer clinically advantageous utility, particularly for the monitoring of therapeutic drugs and of the status of the immune system. This Perspective argues that dermal interstitial fluid cannot be generally considered a diagnostically useful proxy for blood, yet that it can offer advantageous utility for the monitoring of therapeutic drugs and of the status of the immune system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular properties that influence the oral bioavailability of drug candidates
Veber, D. F., Johnson, S. R., Cheng, H.-Y., Smith, B. R., Ward, K. W., & Kopple, K. D. (2002) · Journal of Medicinal Chemistry · doi:10.1021/jm020017n · Cited by 8,420 · cited 1×
“…between enhanced lipid-bilayer penetration and decreased escape kinetics has been investigated for hydrophobic solutes in vitro 41 , and the kinetics of hydrophobic molecules characterized in vivo in the context of designing drugs for rapid uptake by gut tissue or for permeation through it 42,43 .”
Kumar, A., Roberts, D., Wood, K. E., Light, B., Parrillo, J. E., Sharma, S., Suppes, R., Feinstein, D., Zanotti, S., Taiberg, L., et al. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000217961.75225.e9 · Cited by 6,109 · cited 1×
“Point-of-care devices that can sensitively detect the initial stages of immune responses in the dermis would have a profound impact on the management of sepsis and other diseases for which early detection greatly decreases the risk of mortality 128 .”
Guo (2020) · doi:10.1186/s40779-020-00240-0 · Cited by 4,735 · cited 1×
“https://doi.org/10.1038/s41551-022-00998-9 of infections such as SARS-CoV-2 and influenza 121,122 , and the management of chronic inflammatory disorders such as lupus and systemic juvenile idiopathic arthritis 123 .”
InfluentialInto the Eye of the Cytokine Storm
Tisoncik, J. R., Korth, M. J., Simmons, C. P., Farrar, J., Martin, T. R., & Katze, M. G. (2012) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.05015-11 · Cited by 1,940 · cited 1×
“https://doi.org/10.1038/s41551-022-00998-9 of infections such as SARS-CoV-2 and influenza 121,122 , and the management of chronic inflammatory disorders such as lupus and systemic juvenile idiopathic arthritis 123 .”
InfluentialWearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citationSkin immune sentinels in health and disease
Nestle, F. O., Di Meglio, P., Qin, J.-Z., & Nickoloff, B. J. (2009) · Nature Reviews Immunology · doi:10.1038/nri2622 · Cited by 1,420
Diabetes and vascular disease: pathophysiology, clinical consequences, and medical therapy: part I
Paneni, F., Beckman, J. A., Creager, M. A., & Cosentino, F. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht149 · Cited by 1,401
Microvascular fluid exchange and the revised Starling principle
Levick, J. R., & Michel, C. C. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq062 · Cited by 1,183 · cited 2×
“Under homoeostatic conditions, fluid flow is unidirectional, from capillary to ISF to lymph 25 .”
Physiology and function of the tight junction
Anderson, J. M., & Van Itallie, C. M. (2009) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a002584 · Cited by 1,059 · cited 1×
“…IEJs are tight junctions that block all but the smallest of analytes (<4 Å) in their closed state; still, these exhibit frequent breaks and undergo remodelling that permits the leakage of larger molecules 27,34,35 (however, this has not been rigorously proven for the capillary endothelium).”
Interstitial-lymphatic mechanisms in the control of extracellular fluid volume
Aukland, K., & Reed, R. K. (1993) · Physiological Reviews · doi:10.1152/physrev.1993.73.1.1 · Cited by 934
Cited by
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Skin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Applied body-fluid analysis by wearable devices
Brasier, N., Wang, J., Gao, W., Sempionatto, J. R., Dincer, C., Ates, H. C., Güder, F., Olenik, S., Schauwecker, I., Schaffarczyk, D., et al. (2024) · Nature · doi:10.1038/s41586-024-08249-4 · Cited by 298
Biomolecular sensors for advanced physiological monitoring
Flynn, C. D., Chang, D., Mahmud, A., Yousefi, H., Das, J., Riordan, K. T., Sargent, E. H., & Kelley, S. O. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00067-z · Cited by 226
Bioadhesive Technology Platforms
Wu, S. J., & Zhao, X. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00380 · Cited by 218
Wearable Electrochemical Biosensors for Advanced Healthcare Monitoring
Duan, H., Peng, S., He, S., Tang, S., Goda, K., Wang, C. H., & Li, M. (2025) · Advanced Science · doi:10.1002/advs.202411433 · Cited by 195
Wu, Z., Qiao, Z., Chen, S., Fan, S., Liu, Y., Qi, J., & Lim, C. T. (2024) · Communications Materials · doi:10.1038/s43246-024-00468-6 · Cited by 183
Wearable flexible microfluidic sensing technologies
Chen, S., Qiao, Z., Niu, Y., Yeo, J. C., Liu, Y., Qi, J., Fan, S., Liu, X., Lee, J. Y., & Lim, C. T. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00094-w · Cited by 168
“Wick extraction, suction blisters, sonophoresis, micro-dialysis and thermal ablation can be applied to collect ISF, but these methods can cause local trauma or stratum corneum disruption 111,112 .”
BackgroundInfluentialA microneedle device for rapid dermal interstitial fluid sampling
Hung, A. H., Kamat, N. U., Bermudez, A., Boczek, S. M., Garcia-Marqués, F. J., Tan, Y. L., Hwang, J. (., Sinawang, P. D., Ilyin, D., Jacobson, G. B., et al. (2025) · Science Advances · doi:10.1126/sciadv.adx5492 · Cited by 22
A Microneedle Device for Rapid Dermal Interstitial Fluid Sampling
Hung, A. H., Rajesh, N. U., Bermudez, A., Boczek, S. M., Garcia-Marqués, F. J., Tan, Y. L., Hwang, J. (., Sinawang, P. D., Ilyin, D., Jacobson, G. B., et al. (2025) · doi:10.1101/2025.03.13.641882 · Cited by 22
Metadata
- Authors
- Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J.
- Venue
- Nature Biomedical Engineering
- Published
- 2023-01-19
- Volume
- 7
- Issue
- 12
- Pages
- 1541-1555
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W4317500685
- Cited by
- 360
- References
- 121
- FWCI
- 26.39
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.