Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Open accessThe DOI matches its Crossref record; 121 of the 121 references it cites were found in a registry or an index.
Abstract
The volume of interstitial fluid (ISF) in the human body is three times that of blood. Yet, collecting diagnostically useful ISF is more challenging than collecting blood because the extraction of dermal ISF disrupts the delicate balance of pressure between ISF, blood and lymph, and because the triggered local inflammation further skews the concentrations of many analytes in the extracted fluid. In this Perspective, we overview the most meaningful differences in the make-up of ISF and blood, and discuss why ISF cannot be viewed generally as a diagnostically useful proxy for blood. We also argue that continuous sensing of small-molecule analytes in dermal ISF via rapid assays compatible with nanolitre sample volumes or via miniaturized sensors inserted into the dermis can offer clinically advantageous utility, particularly for the monitoring of therapeutic drugs and of the status of the immune system. This Perspective argues that dermal interstitial fluid cannot be generally considered a diagnostically useful proxy for blood, yet that it can offer advantageous utility for the monitoring of therapeutic drugs and of the status of the immune system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular properties that influence the oral bioavailability of drug candidates
Veber, D. F., Johnson, S. R., Cheng, H.-Y., Smith, B. R., Ward, K. W., & Kopple, K. D. (2002) · Journal of Medicinal Chemistry · doi:10.1021/jm020017n · Cited by 8,420 · cited 1×
“…between enhanced lipid-bilayer penetration and decreased escape kinetics has been investigated for hydrophobic solutes in vitro 41 , and the kinetics of hydrophobic molecules characterized in vivo in the context of designing drugs for rapid uptake by gut tissue or for permeation through it 42,43 .”
Kumar, A., Roberts, D., Wood, K. E., Light, B., Parrillo, J. E., Sharma, S., Suppes, R., Feinstein, D., Zanotti, S., Taiberg, L., et al. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000217961.75225.e9 · Cited by 6,109 · cited 1×
“Point-of-care devices that can sensitively detect the initial stages of immune responses in the dermis would have a profound impact on the management of sepsis and other diseases for which early detection greatly decreases the risk of mortality 128 .”
Guo (2020) · doi:10.1186/s40779-020-00240-0 · Cited by 4,735 · cited 1×
“https://doi.org/10.1038/s41551-022-00998-9 of infections such as SARS-CoV-2 and influenza 121,122 , and the management of chronic inflammatory disorders such as lupus and systemic juvenile idiopathic arthritis 123 .”
InfluentialInto the Eye of the Cytokine Storm
Tisoncik, J. R., Korth, M. J., Simmons, C. P., Farrar, J., Martin, T. R., & Katze, M. G. (2012) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.05015-11 · Cited by 1,940 · cited 1×
“https://doi.org/10.1038/s41551-022-00998-9 of infections such as SARS-CoV-2 and influenza 121,122 , and the management of chronic inflammatory disorders such as lupus and systemic juvenile idiopathic arthritis 123 .”
InfluentialWearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citationSkin immune sentinels in health and disease
Nestle, F. O., Di Meglio, P., Qin, J.-Z., & Nickoloff, B. J. (2009) · Nature Reviews Immunology · doi:10.1038/nri2622 · Cited by 1,420
Diabetes and vascular disease: pathophysiology, clinical consequences, and medical therapy: part I
Paneni, F., Beckman, J. A., Creager, M. A., & Cosentino, F. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht149 · Cited by 1,401
Microvascular fluid exchange and the revised Starling principle
Levick, J. R., & Michel, C. C. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq062 · Cited by 1,183 · cited 2×
“Under homoeostatic conditions, fluid flow is unidirectional, from capillary to ISF to lymph 25 .”
Physiology and function of the tight junction
Anderson, J. M., & Van Itallie, C. M. (2009) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a002584 · Cited by 1,059 · cited 1×
“…IEJs are tight junctions that block all but the smallest of analytes (<4 Å) in their closed state; still, these exhibit frequent breaks and undergo remodelling that permits the leakage of larger molecules 27,34,35 (however, this has not been rigorously proven for the capillary endothelium).”
Interstitial-lymphatic mechanisms in the control of extracellular fluid volume
Aukland, K., & Reed, R. K. (1993) · Physiological Reviews · doi:10.1152/physrev.1993.73.1.1 · Cited by 934
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (2000) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s004240000307 · Cited by 898
Michel, C. C., & Curry, F. E. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.3.703 · Cited by 811
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
The Vast Majority of CLA+ T Cells Are Resident in Normal Skin
Clark, R. A., Chong, B., Mirchandani, N., Brinster, N. K., Yamanaka, K.-I., Dowgiert, R. K., & Kupper, T. S. (2006) · The Journal of Immunology · doi:10.4049/jimmunol.176.7.4431 · Cited by 796
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Self-citationContinuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 737
Wiig, H., & Swartz, M. A. (2012) · Physiological Reviews · doi:10.1152/physrev.00037.2011 · Cited by 722
Effect of Microneedle Design on Pain in Human Volunteers
Gill, H. S., Denson, D. D., Burris, B. A., & Prausnitz, M. R. (2008) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e31816778f9 · Cited by 701
Tehrani, F., Teymourian, H., Wuerstle, B., Kavner, J., Patel, R., Furmidge, A., Aghavali, R., Hosseini-Toudeshki, H., Brown, C., Zhang, F., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00887-1 · Cited by 625
Harbarth, S., Samore, M. H., Lichtenberg, D., & Carmeli, Y. (2000) · Circulation · doi:10.1161/01.cir.101.25.2916 · Cited by 592
Transport of macromolecules across microvascular walls: the two-pore theory
Rippe, B., & Haraldsson, B. (1994) · Physiological Reviews · doi:10.1152/physrev.1994.74.1.163 · Cited by 560
Rocchitta, G., Spanu, A., Babudieri, S., Latte, G., Madeddu, G., Galleri, G., Nuvoli, S., Bagella, P., Demartis, M., Fiore, V., et al. (2016) · Sensors · doi:10.3390/s16060780 · Cited by 555
FLOW THROUGH INTERSTITIUM AND OTHER FIBROUS MATRICES
Levick, J. R. (1987) · Quarterly Journal of Experimental Physiology · doi:10.1113/expphysiol.1987.sp003085 · Cited by 480
Nickoloff, B. J., & Naidu, Y. (1994) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(94)70059-1 · Cited by 459
Blot, S. I., Pea, F., & Lipman, J. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.07.006 · Cited by 444
Pathogenesis of Macrophage Activation Syndrome and Potential for Cytokine- Directed Therapies
Schulert, G. S., & Grom, A. A. (2015) · Annual Review of Medicine · doi:10.1146/annurev-med-061813-012806 · Cited by 402
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390 · cited 1×
“71 ).”
Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid
Wang, Z., Luan, J., Seth, A., Liu, L., You, M., Gupta, P., Rathi, P., Wang, Y., Cao, S., Jiang, Q., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00672-y · Cited by 386
Sampling interstitial fluid from human skin using a microneedle patch
Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw0285 · Cited by 379
Mechanisms of sampling interstitial fluid from skin using a microneedle patch
Samant, P. P., & Prausnitz, M. R. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716772115 · Cited by 363
Shen, L., Weber, C. R., & Turner, J. R. (2008) · The Journal of Cell Biology · doi:10.1083/jcb.200711165 · Cited by 359
Capillary endothelial surface layer selectively reduces plasma solute distribution volume
Vink, H., & Duling, B. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.1.h285 · Cited by 335
Therapeutic drug monitoring of antimicrobials
Roberts, J. A., Norris, R., Paterson, D. L., & Martin, J. H. (2012) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2011.04080.x · Cited by 316
AAPS-FDA Workshop White Paper: Microdialysis Principles, Application and Regulatory Perspectives
Chaurasia, C. S., Müller, M., Bashaw, E. D., Benfeldt, E., Bolinder, J., Bullock, R., Bungay, P. M., DeLange, E. C. M., Derendorf, H., Elmquist, W. F., et al. (2007) · Pharmaceutical Research · doi:10.1007/s11095-006-9206-z · Cited by 316
Dauphin-Ducharme, P., Yang, K., Arroyo-Currás, N., Ploense, K. L., Zhang, Y., Gerson, J., Kurnik, M., Kippin, T. E., Stojanovic, M. N., & Plaxco, K. W. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01616 · Cited by 280
On-Site Therapeutic Drug Monitoring
Ates, H. C., Roberts, J. A., Lipman, J., Cass, A. E. G., Urban, G. A., & Dincer, C. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.03.001 · Cited by 268
Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles
Miller, P. R., Taylor, R. M., Tran, B. Q., Boyd, G., Glaros, T., Chavez, V. H., Krishnakumar, R., Sinha, A., Poorey, K., Williams, K. P., et al. (2018) · Communications Biology · doi:10.1038/s42003-018-0170-z · Cited by 258
Self-citationStructure, Function, and Molecular Control of the Skin Lymphatic System
Skobe, M., & Detmar, M. (2000) · Journal of Investigative Dermatology Symposium Proceedings · doi:10.1046/j.1087-0024.2000.00001.x · Cited by 257
Lin, S., Cheng, X., Zhu, J., Wang, B., Jelinek, D., Zhao, Y., Wu, T.-Y., Horrillo, A., Tan, J., Yeung, J., et al. (2022) · Science Advances · doi:10.1126/sciadv.abq4539 · Cited by 255
Protein Binding: Do We Ever Learn?
Zeitlinger, M. A., Derendorf, H., Mouton, J. W., Cars, O., Craig, W. A., Andes, D., & Theuretzbacher, U. (2011) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.01433-10 · Cited by 249
Carlson, A. L., Sherr, J. L., Shulman, D. I., Garg, S. K., Pop-Busui, R., Bode, B. W., Lilenquist, D. R., Brazg, R. L., Kaiserman, K. B., Kipnes, M. S., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0319 · Cited by 230
Compilation of 222 drugs’ plasma protein binding data and guidance for study designs
Zhang, F., Xue, J., Shao, J., & Jia, L. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.12.018 · Cited by 220
Microneedle-based device for the one-step painless collection of capillary blood samples
Blicharz, T. M., Gong, P., Bunner, B. M., Chu, L. L., Leonard, K. M., Wakefield, J. A., Williams, R. E., Dadgar, M., Tagliabue, C. A., El Khaja, R., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0194-1 · Cited by 216
Intravital analysis of vascular permeability in mice using two-photon microscopy
Egawa, G., Nakamizo, S., Natsuaki, Y., Doi, H., Miyachi, Y., & Kabashima, K. (2013) · Scientific Reports · doi:10.1038/srep01932 · Cited by 213
Microneedle Aptamer-Based Sensors for Continuous, Real-Time Therapeutic Drug Monitoring
Wu, Y., Tehrani, F., Teymourian, H., Mack, J., Shaver, A., Reynoso, M., Kavner, J., Huang, N., Furmidge, A., Duvvuri, A., et al. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c00829 · Cited by 212
Localization of Basement Membrane Components After Dermal-Epidermal Junction Separation
Woodley, D. T., Sauder, D. N., Talley, M. J., Silver, M. H., Grotendorst, G. R., & Qwarnström, E. E. (1983) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12543517 · Cited by 210
Reed, R. K., & Rubin, K. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq143 · Cited by 209 · cited 1×
“We refer to previous review articles for a detailed discussion on the flow of analytes into ISF 11 , on micronee-dle devices for ISF sensing 12–14 and on specific applications such as therapeutic-drug monitoring 15 .”
Tran, B. Q., Miller, P. R., Taylor, R. M., Boyd, G., Mach, P. M., Rosenzweig, C. N., Baca, J. T., Polsky, R., & Glaros, T. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00642 · Cited by 198
Self-citationSuccessful application of large microneedle patches by human volunteers
Ripolin, A., Quinn, J., Larrañeta, E., Vicente-Perez, E. M., Barry, J., & Donnelly, R. F. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.02.011 · Cited by 193
Sime, F. B., Roberts, M. S., Peake, S. L., Lipman, J., & Roberts, J. A. (2012) · Annals of Intensive Care · doi:10.1186/2110-5820-2-35 · Cited by 184
Benefits of Therapeutic Drug Monitoring of Vancomycin: A Systematic Review and Meta-Analysis
Ye, Z.-K., Tang, H.-L., & Zhai, S.-D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0077169 · Cited by 181
De Paepe, P., Belpaire, F. M., & Buylaert, W. A. (2002) · Clinical Pharmacokinetics · doi:10.2165/00003088-200241140-00002 · Cited by 181
Rawson, T. M., Gowers, S. A. N., Freeman, D. M. E., Wilson, R. C., Sharma, S., Gilchrist, M., MacGowan, A., Lovering, A., Bayliss, M., Kyriakides, M., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30131-1 · Cited by 180
Determinants of valve gating in collecting lymphatic vessels from rat mesentery
Davis, M. J., Rahbar, E., Gashev, A. A., Zawieja, D. C., & Moore, J. E. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00133.2011 · Cited by 179
Design, Development, and Evaluation of a Novel Microneedle Array-based Continuous Glucose Monitor
Jina, A., Tierney, M. J., Tamada, J. A., McGill, S., Desai, S., Chua, B., Chang, A., & Christiansen, M. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814526191 · Cited by 176
Anatomy of the Lymphatic System and the Lymphosome Concept with Reference to Lymphedema
Scaglioni, M., & Suami, H. (2018) · Seminars in Plastic Surgery · doi:10.1055/s-0038-1635118 · Cited by 170
Structure and function of endothelial caveolae
Stan, R. (2002) · Microscopy Research and Technique · doi:10.1002/jemt.10089 · Cited by 167
Leung, K. K., Downs, A. M., Ortega, G., Kurnik, M., & Plaxco, K. W. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01183 · Cited by 166
Capillaroscopy and the measurement of capillary pressure
Shore, A. C. (2000) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2000.00278.x · Cited by 164
Monitoring biomolecule concentrations in tissue using a wearable droplet microfluidic-based sensor
Nightingale, A. M., Leong, C. L., Burnish, R., Hassan, S.-U., Zhang, Y., Clough, G. F., Boutelle, M. G., Voegeli, D., & Niu, X. (2019) · Nature Communications · doi:10.1038/s41467-019-10401-y · Cited by 160
García‐Guzmán, J. J., Pérez‐Ràfols, C., Cuartero, M., & Crespo, G. A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116148 · Cited by 149
The Organization of Human Epidermis: Functional Epidermal Units and Phi Proportionality
Hoath, S. B., & Leahy, D. G. (2003) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2003.12606.x · Cited by 145
Watkins, Z., Karajić, A., Young, T., White, R. J., & Heikenfeld, J. C. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02403 · Cited by 143
Self-citationForecasting the cytokine storm following systemic interleukin (IL)-2 administration
Panelli, M. C., White, R., Foster, M., Martin, B., Wang, E., Smith, K., & Marincola, F. M. (2004) · Journal of Translational Medicine · doi:10.1186/1479-5876-2-17 · Cited by 139
The Determination of Lipids and Proteins in Suction Blister Fluid
Vermeer, B. J., Reman, F. C., & van Gent, C. M. (1979) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12531833 · Cited by 135
Protein Concentration in Interstitial and Lymphatic Fluids from the Subcutaneous Tissue
Rutili, G., & Arfors, K. (1977) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1977.tb10345.x · Cited by 133
Closed-loop control of circulating drug levels in live animals
Mage, P. L., Ferguson, B. S., Maliniak, D., Ploense, K. L., Kippin, T. E., & Soh, H. T. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0070 · Cited by 133
Self-citationSkin Cell Proliferation Stimulated by Microneedles
Liebl, H., & Kloth, L. C. (2012) · Journal of the American College of Clinical Wound Specialists · doi:10.1016/j.jccw.2012.11.001 · Cited by 130
From the beaker to the body: translational challenges for electrochemical, aptamer-based sensors
Arroyo-Currás, N., Dauphin-Ducharme, P., Scida, K., & Chávez, J. L. (2020) · Analytical Methods · doi:10.1039/d0ay00026d · Cited by 129
Regulation of blood vascular permeability in the skin
Ono, S., Egawa, G., & Kabashima, K. (2017) · Inflammation and Regeneration · doi:10.1186/s41232-017-0042-9 · Cited by 121
Wan, W., Skandari, M. R., Minc, A., Nathan, A. G., Winn, A., Zarei, P., O’Grady, M., & Huang, E. S. (2018) · Diabetes Care · doi:10.2337/dc17-1821 · Cited by 118
Partitioning, diffusivity and clearance of skin permeants in mammalian dermis
Kretsos, K., Miller, M. A., Zamora-Estrada, G., & Kasting, G. B. (2007) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2007.06.020 · Cited by 116
Self-citationImpaired Target Site Penetration of Vancomycin in Diabetic Patients following Cardiac Surgery
Skhirtladze, K., Hutschala, D., Fleck, T., Thalhammer, F., Ehrlich, M. P., Vukovich, T., Müller, M., & Tschernko, E. (2006) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.50.4.1372-1375.2006 · Cited by 116
Microneedle Arrays for Sampling and Sensing Skin Interstitial Fluid
Kashaninejad, N., Munaz, A., Moghadas, H., Yadav, S., Umer, M., & Nguyen, N. (2021) · Chemosensors · doi:10.3390/chemosensors9040083 · Cited by 116
Intradermal vaccination using the novel microneedle device MicronJet600: Past, present, and future
Levin, Y., Kochba, E., Hung, I., & Kenney, R. (2015) · Human Vaccines & Immunotherapeutics · doi:10.1080/21645515.2015.1010871 · Cited by 108
The challenge of long-term stability for nucleic acid-based electrochemical sensors
Shaver, A., & Arroyo‐Currás, N. (2021) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2021.100902 · Cited by 105
A Model for Mechanics of Primary Lymphatic Valves
Mendoza, E., & Schmid-Scho¨nbein, G. W. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1568128 · Cited by 104
Zheng, H., GhavamiNejad, A., GhavamiNejad, P., Samarikhalaj, M., Giacca, A., & Poudineh, M. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01033 · Cited by 104
Effect of Acetaminophen on CGM Glucose in an Outpatient Setting
Maahs, D. M., DeSalvo, D., Pyle, L., Ly, T., Messer, L., Clinton, P., Westfall, E., Wadwa, R. P., & Buckingham, B. (2015) · Diabetes Care · doi:10.2337/dc15-1096 · Cited by 102
Kiang, T. K. L., Ranamukhaarachchi, S. A., & Ensom, M. H. H. (2017) · Pharmaceutics · doi:10.3390/pharmaceutics9040043 · Cited by 101
Butterfield, J. M., Patel, N., Pai, M. P., ROSANO, T. G., Drusano, G. L., & Lodise, T. P. (2011) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.01674-10 · Cited by 99
Dermal Clearance Model for Epidermal Bioavailability Calculations
Ibrahim, R. E., Nitsche, J. M., & Kasting, G. B. (2012) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23106 · Cited by 83
Self-citationGarg, S. K., Liljenquist, D., Bode, B., Christiansen, M. P., Bailey, T. S., Brazg, R. L., Denham, D. S., Chang, A. R., Akturk, H. K., Dehennis, A., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0182 · Cited by 83
Joseph, J. I. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820911919 · Cited by 82
Effects of Surgery on the Pharmacokinetic Parameters of Drugs
Kennedy, J., & Riji, A. M. V. (1998) · Clinical Pharmacokinetics · doi:10.2165/00003088-199835040-00003 · Cited by 80
Quantifying the Composition of Human Skin for Glucose Sensor Development
Groenendaal, W., von Basum, G., Schmidt, K. A., Hilbers, P. A. J., & van Riel, N. A. W. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400502 · Cited by 79
Superswelling Microneedle Arrays for Dermal Interstitial Fluid (Prote)Omics
Laszlo, E., Crescenzo, G. D., Nieto-Argüello, A., Banquy, X., & Brambilla, D. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202106061 · Cited by 78
Morphological and cytochemical aspects of capillary permeability
Bendayan, M. (2002) · Microscopy Research and Technique · doi:10.1002/jemt.10088 · Cited by 75
A Modern View of the Interstitial Space in Health and Disease
Stewart, R. H. (2020) · Frontiers in Veterinary Science · doi:10.3389/fvets.2020.609583 · Cited by 75
Kolluru, C., Williams, M., Yeh, J. S., Noel, R. K., Knaack, J. S., & Prausnitz, M. R. (2019) · Biomedical Microdevices · doi:10.1007/s10544-019-0363-3 · Cited by 72
Dermal Capillary Clearance: Physiology and Modeling
Kretsos, K., & Kasting, G. B. (2005) · Skin Pharmacology and Physiology · doi:10.1159/000083706 · Cited by 71
Self-citationGebhart, S., Faupel, M., Fowler, R., Kapsner, C., Lincoln, D., McGee, V., Pasqua, J., Steed, L., Wangsness, M., Xu, F., et al. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503321827812 · Cited by 69
Jamalian, S., Jafarnejad, M., Zawieja, S. D., Bertram, C. D., Gashev, A. A., Zawieja, D. C., Davis, M. J., & Moore, J. E. (2017) · Scientific Reports · doi:10.1038/s41598-017-11599-x · Cited by 69
Christiansen, M. P., Klaff, L. J., Bailey, T. S., Brazg, R., Carlson, G., & Tweden, K. S. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0020 · Cited by 62
Design of a Biosensor for Continual, Transdermal Glucose Monitoring
Tierney, M. J., Jayalakshmi, Y., Parris, N. A., Reidy, M. P., Uhegbu, C., & Vijayakumar, P. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1681 · Cited by 59
Liao, Y., Kuo, W.-C., Chou, S.-Y., Tsai, C.-S., Lin, G.-L., Tsai, M.-R., Shih, Y.-T., Lee, G.-G., & Sun, C. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003266 · Cited by 58
Clough, G. F., Jackson, C. L., Lee, J. J. P., Jamal, S. C., & Church, M. K. (2007) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5700930 · Cited by 54
Noddeland, H. (1982) · Scandinavian Journal of Clinical & Laboratory Investigation · doi:10.1080/00365518209168062 · Cited by 53
Kanick, S. C., Schneider, P. A., Klitzman, B. M., Wisniewski, N. A., & Rebrin, K. (2019) · Microvascular Research · doi:10.1016/j.mvr.2019.02.002 · Cited by 52
Xue, Y., Luo, X., Xu, W., Wang, K., Wu, M., Chen, L., Yang, G., Ma, K., Yao, M., Zhou, Q., et al. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03590 · Cited by 45
Taylor, R. M., Miller, P. R., Ebrahimi, P., Polsky, R., & Baca, J. T. (2018) · Laboratory Animals · doi:10.1177/0023677218758801 · Cited by 44
Self-citationKurnik, M., Pang, E. Z., & Plaxco, K. W. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202007256 · Cited by 44
Chien, J., Baker, S. W., Soh, H. T., & Arbabian, A. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3020789 · Cited by 43
Self-citationNedrebø, T., Reed, R. K., Jonsson, R., Berg, A., & Wiig, H. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.057216 · Cited by 42
Pharmacokinetic implications of changing blood flow in skin
Riviere, J. E., & Williams, P. L. (1992) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600810628 · Cited by 42
Continuous Free Cortisol Profiles in Healthy Men
Bhake, R., Russell, G. M., Kershaw, Y., Stevens, K., Zaccardi, F., Warburton, V. E. C., Linthorst, A. C. E., & Lightman, S. L. (2020) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgz002 · Cited by 42
Collison, M. E., Stout, P. J., Glushko, T. S., Pokela, K. N., Mullins-Hirte, D. J., Racchini, J. R., Walter, M. A., Mecca, S. P., Rundquist, J., Allen, J. J., et al. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1665 · Cited by 40
Fibrotic Encapsulation Is the Dominant Source of Continuous Glucose Monitor Delays
McClatchey, P. M., McClain, E. S., Williams, I. M., Malabanan, C. M., James, F. D., Lord, P., Gregory, J. M., Cliffel, D. E., & Wasserman, D. H. (2019) · Diabetes · doi:10.2337/db19-0229 · Cited by 40
Spehar‐Délèze, A., Anastasova, S., & Vadgama, P. M. (2021) · Chemosensors · doi:10.3390/chemosensors9080195 · Cited by 39
Ultraslow microdialysis and microfiltration for in-line, on-line and off-line monitoring
Korf, J., Huinink, K. D., & Posthuma‐Trumpie, G. A. (2010) · Trends in biotechnology · doi:10.1016/j.tibtech.2009.12.005 · Cited by 37
Boscari, F., Vettoretti, M., Cavallin, F., Amato, A. M. L., Uliana, A., Vallone, V., Avogaro, A., Facchinetti, A., & Bruttomesso, D. (2021) · Journal of Endocrinological Investigation · doi:10.1007/s40618-021-01624-2 · Cited by 33
Protein Concentration of Subcutaneous Interstitial Fluid in the Human Leg
Haaverstad, R., Romslo, I., Larsen, S., & Myhre, H. O. (2008) · International Journal of Microcirculation · doi:10.1159/000179159 · Cited by 32
LaCount, T. D., Zhang, Q. Y., Hao, J., Ghosh, P., Raney, S. G., Talattof, A., Kasting, G. B., & Li, S. K. (2020) · The AAPS Journal · doi:10.1208/s12248-020-00451-2 · Cited by 30
Self-citationHamada, Y., Kuti, J. L., & Nicolau, D. P. (2015) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkv074 · Cited by 24
Zaleska, M., Olszewski, W. L., Durlik, M., & Miller, N. E. (2013) · Lymphatic Research and Biology · doi:10.1089/lrb.2013.0014 · Cited by 24
Yuan, Y., DeBrosse, M. C., Brothers, M. C., Kim, S. S., Sereda, A., Ivanov, N. V., Hussain, S. M., & Heikenfeld, J. C. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c14175 · Cited by 23
Self-citationSubcutaneous Capillary Filtrate Collector for Measurement of Blood Glucose
Ash, S. R., Poulos, J. T., Rainier, J. B., Zopp, W. E., Janle, E. M., & Kissinger, P. T. (1992) · ASAIO Journal · doi:10.1097/00002480-199207000-00067 · Cited by 22
The Role of Payload Hydrophobicity in Nanotherapeutic Pharmacokinetics
Norvaišas, P., & Žiemys, A. (2014) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23996 · Cited by 21
Using Flash Continuous Glucose Monitoring in Primary Practice
Hirsch, I. B., & Wright, E. E. (2018) · Clinical Diabetes · doi:10.2337/cd18-0054 · Cited by 15
Plasma proteins in a standardised skin mini-erosion (II): effects of extraction pressure
Svedman, C., Yu, B. B., Ryan, T. J., & Svensson, H. (2002) · BMC Dermatology · doi:10.1186/1471-5945-2-4 · Cited by 13
Stout, P. J., Pokela, K. N., Mullins-Hirte, D. J., Hoegh, T., Hilgers, M. E., Thorp, A., Collison, M. E., & Glushko, T. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1674 · Cited by 10
Cited by
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Skin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Applied body-fluid analysis by wearable devices
Brasier, N., Wang, J., Gao, W., Sempionatto, J. R., Dincer, C., Ates, H. C., Güder, F., Olenik, S., Schauwecker, I., Schaffarczyk, D., et al. (2024) · Nature · doi:10.1038/s41586-024-08249-4 · Cited by 298
Biomolecular sensors for advanced physiological monitoring
Flynn, C. D., Chang, D., Mahmud, A., Yousefi, H., Das, J., Riordan, K. T., Sargent, E. H., & Kelley, S. O. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00067-z · Cited by 226
Bioadhesive Technology Platforms
Wu, S. J., & Zhao, X. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00380 · Cited by 218
Metadata
- Authors
- Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J.
- Venue
- Nature Biomedical Engineering
- Published
- 2023-01-19
- Volume
- 7
- Issue
- 12
- Pages
- 1541-1555
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W4317500685
- Cited by
- 360
- References
- 121
- FWCI
- 26.39
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.