Stretchable ionic–electronic bilayer hydrogel electronics enable in situ detection of solid-state epidermal biomarkers
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Continuous and in situ detection of biomarkers in biofluids (for example, sweat) can provide critical health data but is limited by biofluid accessibility. Here we report a sensor design that enables in situ detection of solid-state biomarkers ubiquitously present on human skin. We deploy an ionic–electronic bilayer hydrogel to facilitate the sequential dissolution, diffusion and electrochemical reaction of solid-state analytes. We demonstrate continuous monitoring of water-soluble analytes (for example, solid lactate) and water-insoluble analytes (for example, solid cholesterol) with ultralow detection limits of 0.51 and 0.26 nmol cm−2, respectively. Additionally, the bilayer hydrogel electrochemical interface reduces motion artefacts by a factor of three compared with conventional liquid-sensing electrochemical interfaces. In a clinical study, solid-state epidermal biomarkers measured by our stretchable wearable sensors showed a high correlation with biomarkers in human blood and dynamically correlated with physiological activities. These results present routes to universal platforms for biomarker monitoring without the need for biofluid acquisition. Biomarkers in biofluids are widely used for medical diagnosis, but their use is limited by accessibility. Here the authors present a stretchable wearable sensor allowing in situ detection of solid-state biomarkers on human skin, hence avoiding biofluid acquisition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly accurate protein structure prediction with AlphaFold
Jumper, J., Evans, R., Pritzel, A., Green, T., Figurnov, M., Ronneberger, O., Tunyasuvunakool, K., Bates, R., Žídek, A., Potapenko, A., et al. (2021) · Nature · doi:10.1038/s41586-021-03819-2 · Cited by 43,764
Trumbo, P., Schlicker, S., Yates, A. A., & Poos, M. (2002) · Journal of the American Dietetic Association · doi:10.1016/s0002-8223(02)90346-9 · Cited by 5,993 · cited 2×
“Biomarkers in biofluids such as blood, urine, saliva and sweat indicate human physiological processes and disease states and are widely used for medical diagnosis and health monitoring 1–3 .”
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 2×
“…and blood) and SEBs from different locations and the placement of sensors for each type of biofluid and solid-state biomarker. b , Comparison of ease of access and correlation to blood biomarker concentration for different biofluids 6,10,12–14 , volatile organic compounds (VOC) 15,16 and SEBs.”
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · cited 1×
“Wearable sensors 4,5 provide an alternative means for in situ, continuous and non-invasive detection 6–16 of human sweat biomarkers, such as metabolites 6,7 , electrolytes 8 , vitamins 10 and amino acids 11 .”
Metabolite profiles and the risk of developing diabetes
Wang, T. J., Larson, M. G., Vasan, R. S., Cheng, S., Rhee, E. P., McCabe, E., Lewis, G. D., Fox, C. S., Jacques, P. F., Fernandez, C., et al. (2011) · Nature Medicine · doi:10.1038/nm.2307 · Cited by 3,143
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315 · cited 1×
“Wearable sensors 4,5 provide an alternative means for in situ, continuous and non-invasive detection 6–16 of human sweat biomarkers, such as metabolites 6,7 , electrolytes 8 , vitamins 10 and amino acids 11 .”
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308 · cited 1×
“Wearable sensors 4,5 provide an alternative means for in situ, continuous and non-invasive detection 6–16 of human sweat biomarkers, such as metabolites 6,7 , electrolytes 8 , vitamins 10 and amino acids 11 .”
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270 · cited 3×
“7).”
An epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers
Sempionatto, J. R., Lin, M., Yin, L., De la paz, E., Pei, K., Sonsa-ard, T., de Loyola Silva, A. N., Khorshed, A. A., Zhang, F., Tostado, N., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00685-1 · Cited by 658 · cited 1×
“Sweat can be induced by physical exercise, iontophoresis 7 and the application of drugs, such as pilocarpine 9 .”
Pappas, A. (2009) · Dermato-Endocrinology · doi:10.4161/derm.1.2.7811 · Cited by 326 · cited 1×
“20 and 21, and Supplementary Note 4) 36–38 .”
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., et al. (2011) · Talanta · doi:10.1016/j.talanta.2010.10.055 · Cited by 279 · cited 1×
“…and blood) and SEBs from different locations and the placement of sensors for each type of biofluid and solid-state biomarker. b , Comparison of ease of access and correlation to blood biomarker concentration for different biofluids 6,10,12–14 , volatile organic compounds (VOC) 15,16 and SEBs.”
A mountable toilet system for personalized health monitoring via the analysis of excreta
Park, S.-M., Won, D. D., Lee, B. J., Escobedo, D., Esteva, A., Aalipour, A., Ge, T. J., Kim, J. H., Suh, S., Choi, E. H., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0534-9 · Cited by 175
Metadata
- Authors
- Arwani, R. T., Tan, S. C. L., Sundarapandi, A., Goh, W. P., Liu, Y., Leong, F. Y., Yang, W., Zheng, X. T., Yu, Y., Jiang, C., Ang, Y. C., Kong, L., Teo, S. L., Chen, P., Su, X., Li, H., Liu, Z., Chen, X., Yang, L., & Liu, Y.
- Venue
- Nature Materials
- Published
- 2024-06-12
- Volume
- 23
- Issue
- 8
- Pages
- 1115-1122
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- OpenAlex
- W4399586219
- Cited by
- 222
- References
- 14
- FWCI
- 23.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.