Geodesy and metrology with a transportable optical clock
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Optical atomic clocks, due to their unprecedented stability1–3 and uncertainty3–6, are already being used to test physical theories7,8 and herald a revision of the International System of Units9,10. However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy11, a major challenge remains: their transformation from highly specialized instruments restricted to national metrology laboratories into flexible devices deployable in different locations12–14. Here, we report the first field measurement campaign with a transportable 87Sr optical lattice clock12. We use it to determine the gravity potential difference between the middle of a mountain and a location 90 km away, exploiting both local and remote clock comparisons to eliminate potential clock errors. A local comparison with a 171Yb lattice clock15 also serves as an important check on the international consistency of independently developed optical clocks. This campaign demonstrates the exciting prospects for transportable optical clocks. An atomic clock has been deployed on a field measurement campaign to determine the height of a mountain location 1,000 m above sea level, returning a value that is in good agreement with state-of-the-art geodesy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Present-day optical clocks and frequency links have already demonstrated geopotential (height) comparisons at the few-centimetre level [7, 14, 27]”
From Chapter 1 Theoretical background (1996) · cites this paper as [7]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Within this project, a proof-of-principle experiment of chronometric geodesy was done by comparing two optical clocks separated by a height difference of around 1000 m, using an optical fibre link [61].”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [61]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Chronometric leveling with a transportable optical clock has first been realized with a 87 Sr lattice clock [24] between Modane (France) and Torino (Italy), albeit with a moderate fractional frequency uncertainty of 1 . 9 × 10 -15 [21].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [21]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 1×
“The influence of BBR on the clock frequency has been discussed elsewhere 3,4,34–36 .”
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572 · cited 1×
“The atoms are then trapped in one-dimensional optical lattices operating at the magic wavelengths 31 λ Ybmagic ≈ 759 nm and λ Srmagic ≈ 813 nm, which to first order give a zero differential light shift between the 1 S 0 and 3 P 0 states.”
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460 · cited 6×
“Its path was equipped with two dedicated bidirectional erbium-doped fibre amplifiers that allowed a phase stable signal to be generated at LSM through the Doppler noise cancellation technique 17,18 .”
InfluentialSelf-citationUltrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Lemke, N., Ludlow, A., Barber, Z., Fortier, T., Diddams, S., Jiang, Y., Jefferts, S., Heavner, T., Parker, T., & Oates, C. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.063001 · Cited by 274
Research works printed but not linked: 3
- Vermeer, M. Chronometric levelling. Rep. Finn. Geod. Inst. 83, 2 (1983).
- Denker, H. in Sciences of Geodesy – II (ed. Xu, G.) Ch. 5 (Springer, 2013).
- JCGM (BIPM, IEC, IFCC, ILAC, ISO, IUPAC, IUPAP and OIML) Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement Vol. 100 (International Organization for Standardization, 2008); http://www.bipm.org/utils/common/documents/jcgm/JCGM_100_2008_E.pdf
Cited by
Items 101–200 of 559
Stadnik, Y. V. (2020) · Physical Review D · doi:10.1103/physrevd.102.115016 · Cited by 31
Limits and prospects for long-baseline optical fiber interferometry
Hilweg, C., Shadmany, D., Walther, P. J., Mavalvala, N., & Sudhir, V. (2022) · Optica · doi:10.1364/optica.470430 · Cited by 36
“A related field is relativistic geodesy, where the clock rates of optical frequency standards are compared via optical fiber links to gain information about differences in gravitational potentials between sites [172, 173].”
BackgroundHigh-precision optical time and frequency transfer
Caldwell, E. D., Triano, T., & Sinclair, L. C. (2025) · Advances in Optics and Photonics · doi:10.1364/aop.545290 · Cited by 42
Wang, S., Cao, J. Z., Yuan, J., Liu, D., Shu, H., & Huang, X.-R. (2020) · Optics Express · doi:10.1364/oe.383115 · Cited by 35
Golovizin, A. A., Tregubov, D. O., Fedorova, E. S., Mishin, D., Provorchenko, D. I., Khabarova, K. Y., Sorokin, V. N., & Kolachevsky, N. (2021) · Nature Communications · doi:10.1038/s41467-021-25396-8 · Cited by 34
Two-Color Grating Magneto-Optical Trap for Narrow-Line Laser Cooling
Bondza, S., Lisdat, C., Kroker, S., & Leopold, T. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.044002 · Cited by 34
Self-citationExtreme Spin Squeezing via Optimized One-Axis Twisting and Rotations
Carrasco, S. C., Goerz, M. H., Li, Z., Colombo, S., Vuletić, V., & Malinovsky, V. S. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.064050 · Cited by 34
Robust optical clock transitions in trapped ions using dynamical decoupling
Aharon, N., Spethmann, N., Leroux, I. D., Schmidt, P. O., & Retzker, A. (2019) · New Journal of Physics · doi:10.1088/1367-2630/ab3871 · Cited by 34
Long-distance chronometric leveling with a portable optical clock
Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l061001 · Cited by 33
Self-citationGHZ protocols enhance frequency metrology despite spontaneous decay
Kielinski, T., Schmidt, P. O., & Hammerer, K. (2024) · Science Advances · doi:10.1126/sciadv.adr1439 · Cited by 33
Using quantum optical sensors for determining the Earth’s gravity field from space
Müller, J., & Wu, H. (2020) · Journal of Geodesy · doi:10.1007/s00190-020-01401-8 · Cited by 32
Exploring potential applications of optical lattice clocks in a plate subduction zone
Tanaka, Y., & Katori, H. (2021) · Journal of Geodesy · doi:10.1007/s00190-021-01548-y · Cited by 31
“2017) with an uncertainty of 7 × 10 offer a new tool for chronometric leveling (Grotti et al. 2018).”
MethodDynamical decoupling of laser phase noise in compound atomic clocks
Dörscher, S., Al-Masoudi, A., Bober, M., Schwarz, R., Hobson, R., Sterr, U., & Lisdat, C. (2020) · Communications Physics · doi:10.1038/s42005-020-00452-9 · Cited by 31
Self-citationUncertainty Evaluation of an 171Yb Optical Lattice Clock at NMIJ
Kobayashi, T., Akamatsu, D., Hisai, Y., Tanabe, T., Inaba, H., Suzuyama, T., Hong, F.-L., Hosaka, K., & Yasuda, M. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2870937 · Cited by 31
Clock networks for height system unification: a simulation study
Wu, H., Müller, J., & Lämmerzahl, C. (2019) · Geophysical Journal International · doi:10.1093/gji/ggy508 · Cited by 30
Dicke State Generation and Extreme Spin Squeezing via Rapid Adiabatic Passage
Carrasco, S. C., Goerz, M. H., Malinovskaya, S., Vuletić, V., Schleich, W. P., & Malinovsky, V. S. (2024) · Physical Review Letters · doi:10.1103/physrevlett.132.153603 · Cited by 30
Deployment of a transportable Yb optical lattice clock
Bothwell, T., Brand, W., Fasano, R., Akin, T. G., Whalen, J. D., Grogan, T., Chen, Y.-J., Pomponio, M., Nakamura, T., Rauf, B., et al. (2025) · Optics Letters · doi:10.1364/ol.543310 · Cited by 31
Self-citationOptical atomic clock comparison through turbulent air
Bodine, M. I., Deschênes, J.-D., Khader, I. H., Swann, W. C., Leopardi, H., Beloy, K., Bothwell, T., Brewer, S. M., Bromley, S., Chen, J.-S., et al. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033395 · Cited by 31
“As transportable optical atomic clocks are developed [20,32–34], O-TWTFT will be able to support their comparisons for applications such as fundamental time metrology, relativistic geodesy measurements, or dark matter searches.”
BackgroundPassive optical phase noise cancellation
Hu, L., Tian, X., Wu, G., & Chen, J. (2020) · Optics Letters · doi:10.1364/ol.393010 · Cited by 30
Ab initio quantum theory of mass defect and time dilation in trapped-ion optical clocks
Martínez-Lahuerta, V. J., Eilers, S., Mehlstäubler, T. E., Schmidt, P. O., & Hammerer, K. (2022) · Physical Review A · doi:10.1103/physreva.106.032803 · Cited by 31
Reduction of light shifts in Ramsey spectroscopy with a combined error signal
Shuker, M., Pollock, J. W., Boudot, R., Yudin, V. I., Taichenachev, A. V., Kitching, J., & Donley, E. A. (2019) · Applied Physics Letters · doi:10.1063/1.5093921 · Cited by 30
Chronometric Geodesy: Methods and Applications
Delva, P., Denker, H., & Lion, G. (2019) · Fundamental Theories of Physics · doi:10.1007/978-3-030-11500-5_2 · Cited by 28
“Within this project, a proof-of-principle experiment of chronometric geodesy was done by comparing two optical clocks separated by a height difference of around 1000 m, using an optical fibre link [61].”
MethodSelf-citationLindvall, T., Fordell, T., Hanhijärvi, K., Doležal, M., Rahm, J., Weyers, S., & Wallin, A. E. (2025) · Physical Review Applied · doi:10.1103/czlf-bfvp · Cited by 29
“0 × 10 − 15 − 1 / 2”
A robust, high-flux source of laser-cooled ytterbium atoms
Wodey, E., Rengelink, R. J., Meiners, C., Rasel, E. M., & Schlippert, D. (2021) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/abd2d1 · Cited by 27
A 500-km Cascaded White Rabbit Link for High-Performance Frequency Dissemination
Kaur, N., Frank, F., Pinto, J., Tuckey, P. A., & Pottie, P.-É. (2021) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2021.3134163 · Cited by 27
Wang, L., Liu, Y., Jiao, W., Hu, L., Chen, J., & Wu, G. (2022) · Optics Express · doi:10.1364/oe.462808 · Cited by 27
Ytterbium optical lattice clock with instability of order 10 −18
Zhang, A., Xiong, Z.-X., Chen, X., Jiang, Y., Wang, J., Tian, C., Zhu, Q., Wang, B., Xiong, D., He, L., et al. (2022) · Metrologia · doi:10.1088/1681-7575/ac99e4 · Cited by 29
Toward a New Generation of Compact Transportable Yb+ Optical Clocks
Khabarova, K. Y., Kryuchkov, D. S., Borisenko, A., Zalivako, I. V., Semerikov, I. A., Aksenov, M. A., Sherstov, I., Abbasov, T., Tausenev, A. V., & Kolachevsky, N. (2022) · Symmetry · doi:10.3390/sym14102213 · Cited by 28
“This system was used for the first on-field chronometric leveling measurement campaign, which aimed to determine the gravitational redshift between the laboratory clocks at INRIM (Turin) and the transportable clock moved to the Modane underground laboratory [13].”
MethodReducing the Instability of an Optical Lattice Clock Using Multiple Atomic Ensembles
Zheng, X., Dolde, J., & Kolkowitz, S. (2024) · Physical Review X · doi:10.1103/physrevx.14.011006 · Cited by 27
Combined error signal in Ramsey spectroscopy of clock transitions
Yudin, V. I., Taichenachev, A. V., Basalaev, M. Y., Zanon-Willette, T., Mehlstäubler, T. E., Boudot, R., Pollock, J. W., Shuker, M., Donley, E. A., & Kitching, J. (2018) · New Journal of Physics · doi:10.1088/1367-2630/aaf47c · Cited by 27
“Frequency measurements at this level enable improved tests of fundamental physics, as well as new applications like chronometric geodesy [6, 7].”
BackgroundA scalable hardware and software control apparatus for experiments with hybrid quantum systems
Perego, E., Pomponio, M., Detti, A., Duca, L., Sias, C., & Calosso, C. E. (2018) · Review of Scientific Instruments · doi:10.1063/1.5049120 · Cited by 27
Coherent fibre link for synchronization of delocalized atomic clocks
Cizek, M., Pravdova, L., Pham, T. M., Lesundak, A., Hrabina, J., Lazar, J., Pronebner, T., Aeikens, E., Premper, J., Havliš, O., et al. (2022) · Optics Express · doi:10.1364/oe.447498 · Cited by 27
Transportable optical atomic clocks for use in out-of-the-lab environments
Gellesch, M., Jones, J., Barron, R., Singh, A., Sun, Q., Bongs, K., & Singh, Y. (2020) · Advanced Optical Technologies · doi:10.1515/aot-2020-0023 · Cited by 26
Intensity interferometry for ultralight bosonic dark matter detection
Masia‐Roig, H., Figueroa, N. L., Bordon, A., Smiga, J. A., Stadnik, Y. V., Budker, D., Centers, G. P., Gramolin, A. V., Hamilton, P., Khamis, S., et al. (2023) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.108.015003 · Cited by 26
“[96] Jacopo Grotti, Silvio Koller, Stefan Vogt, Sebastian Häfner, Uwe Sterr, Christian Lisdat, Heiner Denker, Christian Voigt, Ludger Timmen, Antoine Rolland, et al.”
BackgroundQuantum-amplified global-phase spectroscopy on an optical clock transition
Zaporski, L., Liu, Q., Velez, G., Radzihovsky, M., Li, Z., Colombo, S., Pedrozo-Peñafiel, E., & Vuletić, V. (2025) · Nature · doi:10.1038/s41586-025-09578-8 · Cited by 25
Non-reciprocity in optical fiber links: experimental evidence
Xu, D., Lopez, O., Amy‐Klein, A., & Pottie, P.-É. (2021) · Optics Express · doi:10.1364/oe.420661 · Cited by 25
Multi-node optical frequency dissemination with post automatic phase correction
Hu, L., Tian, X., Wu, G., Kong, M., Shen, J., & Chen, J. (2020) · Journal of Lightwave Technology · doi:10.1109/jlt.2020.2976167 · Cited by 24
“To date, efforts have mainly focused on long-distance connections between just two locations connected by an optical fiber by correcting phase perturbations between the local and remote end [8], For example, frequency comparison between two separated Sr optical clocks located at PTB (Germany) and SYRTE (France) has be…”
BackgroundLu, X., Guo, F., Wang, Y., Xu, Q., Zhou, C., Xia, J., Wu, W., & Chang, H. (2023) · Metrologia · doi:10.1088/1681-7575/acb05c · Cited by 24
Shen, Z., Shen, W., Zhao, P., Liu, T., Zhang, S., & Chao, D. (2019) · Journal of Earth Science · doi:10.1007/s12583-018-0834-0 · Cited by 24
Distributed multi-parameter quantum metrology with a superconducting quantum network
Zhang, J., Wang, L., Hai, Y.-J., Zhang, J., Chu, J., Jiang, J., Huang, W., Liang, Y., Qiu, J., Sun, X., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-68535-9 · Cited by 23
Cao, J. Z., Yuan, J., Wang, S., Zhang, P., Yuan, Y., Liu, D., Cui, K., Chao, S., Shu, H., Lin, Y., et al. (2022) · Applied Physics Letters · doi:10.1063/5.0079432 · Cited by 23
Yan, C., Shi, H., Yao, Y., Yu, H., Jiang, Y., & Ma, L.-S. (2022) · Chinese Optics Letters · doi:10.3788/col202220.070201 · Cited by 23
All-fiber-based ultrastable laser with long-term frequency stability of 1.1 × 10-14
Huang, Y., Hu, D., Ye, M., Wang, Y., Li, Y., Li, M., Chen, Y., Qu, Q., Wang, L., Liu, L., et al. (2022) · Chinese Optics Letters · doi:10.3788/col202321.031404 · Cited by 23
Optical and Microwave Metrology at the 10−18 Level with an Er/Yb:glass Frequency Comb
Nardelli, N. V., Leopardi, H., Schibli, T. R., & Fortier, T. M. (2023) · Laser & Photonics Review · doi:10.1002/lpor.202200650 · Cited by 23
Sundar, B., Barberena, D., Orioli, A. P., Chu, A., Thompson, J. K., Rey, A. M., & Lewis-Swan, R. J. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.113202 · Cited by 23
Tian, X., Hu, L., Wu, G., & Chen, J. (2020) · Journal of Lightwave Technology · doi:10.1109/jlt.2020.2989328 · Cited by 23
“Thanks to the rapid development over the last decades, newly developed radio frequency (RF) and optical frequency dissemination schemes with ever-increasing performance and fiber distances are expected to play a crucial role for science and technology including geodesy [1], radio astronomy [2], [3], optical clock comp…”
BackgroundHigh diffraction efficiency grating atom chip for magneto-optical trap
Duan, J., Liu, X., Zhou, Y., Xu, X., Chen, L., Zou, C., Zhu, Z., Yu, Z., Ru, N., & Qu, J. (2022) · Optics Communications · doi:10.1016/j.optcom.2022.128087 · Cited by 23
International comparison of optical frequencies with transportable optical lattice clocksPreprint
Clock, I., Networking, O., Collaboration, :, Amy‐Klein, A., Benkler, E., Blondé, P., Bongs, K., Cantin, E., Chardonnet, C., et al. (2024) · arXiv · doi:10.48550/arxiv.2410.22973 · Cited by 23
“They demonstrated its field operation and geodetic measurement by connecting their clock to a reference clock at INRiM (Istituto Nazionale di Ricerca Metrologica) 17 .”
MethodSelf-citationDevelopment of 8-branch Er:fiber frequency comb for Sr and Yb optical lattice clocks
Hisai, Y., Akamatsu, D., Kobayashi, T., Okubo, S., Inaba, H., Hosaka, K., Yasuda, M., & Hong, F.-L. (2019) · Optics Express · doi:10.1364/oe.27.006404 · Cited by 22
High-flux, adjustable, compact cold-atom source
Ravenhall, S., Yuen, B., & Foot, C. J. (2021) · Optics Express · doi:10.1364/oe.423662 · Cited by 22
Steady-state magneto-optical trap of fermionic strontium on a narrow-line transition
Escudero, R. G., Chen, C.-C., Bennetts, S., Pasquiou, B., & Schreck, F. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.033159 · Cited by 23
Optically Loaded Strontium Lattice Clock With a Single Multi-Wavelength Reference Cavity
Barbiero, M., Calonico, D., Levi, F., & Tarallo, M. G. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3165292 · Cited by 22
“Because of its simple electronic structure and its commercial accessible cooling transitions, it finds successful application for optical clocks [5], [6], quantum control and quantum simulation [7], [8], probing new physics beyond the standard model [9], and chronometric geodesy [10]–[12].”
BackgroundSelf-citationTurn-key Voigt optical frequency standard
Liu, Z., Wang, Z., Qin, X., Guan, X., Shi, H., Cao, S., Wei, S., Zhang, J., Xiao, Z., Shi, T., et al. (2025) · Photonics Research · doi:10.1364/prj.545009 · Cited by 22
Compact magneto-optical trap of thulium atoms for a transportable optical clock
Golovizin, A. A., Tregubov, D. O., Mishin, D., Provorchenko, D. I., & Kolachevsky, N. (2021) · Optics Express · doi:10.1364/oe.435105 · Cited by 21
Field deployable atomics package for an optical lattice clock
Kale, Y. B., Singh, A. K., Gellesch, M., Jones, J. M., Morris, D. C., Aldous, M., Bongs, K., & Singh, Y. (2022) · Quantum Science and Technology · doi:10.1088/2058-9565/ac7b40 · Cited by 21
Year-long optical time scale with sub-nanosecond capabilities
Formichella, V., Signorile, G., Thai, T. T., Galleani, L., Pizzocaro, M., Goti, I., Condio, S., Clivati, C., Risaro, M., Levi, F., et al. (2024) · Optica · doi:10.1364/optica.509706 · Cited by 21
Self-citationDual-frequency optical-microwave atomic clocks based on cesium atoms
Shi, T., Wei, Q., Qin, X., Liu, Z., Chen, K., Cao, S., Shi, H., Liu, Z., & Chen, J. (2024) · Photonics Research · doi:10.1364/prj.528942 · Cited by 21
“…have a broad range of applications in basic physics research through frequency ratio measurements[5], such as the verification of general relativity[6], dark matter detection[7], detection of changes in physical constants over time[8], and definition and revision of a base unit of time in the…”
BackgroundAn extended-cavity diode laser at 497 nm for laser cooling and trapping of neutral strontium
Schkolnik, V., Fartmann, O., & Krutzik, M. (2019) · Laser Physics · doi:10.1088/1555-6611/aaffc8 · Cited by 22
“In particular, clocks based on neutral strontium have become widely used over the world in the past, operating uninterrupted over multiple weeks in laboratories and recently started to even perform outside the lab [12].”
BackgroundSimultaneous preparation of two initial clock states in a thulium optical clock
Fedorova, E. S., Golovizin, A. A., Tregubov, D. O., Mishin, D., Provorchenko, D. I., Сорокин, В. Н., Khabarova, K. Y., & Kolachevsky, N. (2020) · Physical Review A · doi:10.1103/physreva.102.063114 · Cited by 21
Dipole-Dipole Frequency Shifts in Multilevel Atoms
Cidrim, A., Orioli, A. P., Sanner, C., Hutson, R. B., Ye, J., Bachelard, R., & Rey, A. M. (2021) · Physical Review Letters · doi:10.1103/physrevlett.127.013401 · Cited by 20
A transportable optical lattice clock at the National Time Service Center*
Kong, D., Wang, Z., Guo, F., Zhang, Q., Lu, X., Wang, Y., & Chang, H. (2020) · Chinese Physics B · doi:10.1088/1674-1056/ab9290 · Cited by 23
Perspective: Practical atom-based quantum sensors
Brown, J. M., & Walker, T. G. (2025) · Physical Review A · doi:10.1103/q6d1-594v · Cited by 21
Absolute frequency measurement of a Yb optical clock at the limit of the Cs fountain
Goti, I., Condio, S., Clivati, C., Risaro, M., Gozzelino, M., Costanzo, G. A., Levi, F., Calonico, D., & Pizzocaro, M. (2023) · Metrologia · doi:10.1088/1681-7575/accbc5 · Cited by 20
“at PTB [30], and via very long baseline interferometry in col-”
BackgroundSelf-citationAtom-Number Enhancement by Shielding Atoms From Losses in Strontium Magneto-Optical Traps
Höschele, J., Buob, S., Rubio-Abadal, A., Makhalov, V., & Tarruell, L. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.064011 · Cited by 20
“Existing experiments can readily benefit from our scheme, since it requires no additional changes in the setups and it is compatible with the miniaturization of experiments [6, 7, 54].”
MethodJia, Q., Li, Q., & Liu, L. (2024) · Aerospace Science and Technology · doi:10.1016/j.ast.2024.109136 · Cited by 20
Modeling motional energy spectra and lattice light shifts in optical lattice clocks
Beloy, K., McGrew, W. F., Zhang, X., Nicolodi, D., Fasano, R., Hassan, Y. S., Brown, R. C., & Ludlow, A. D. (2020) · Physical Review A · doi:10.1103/physreva.101.053416 · Cited by 20
Optical Atomic Clocks for Redefining SI Units of Time and Frequency
Sharma, L., Rathore, H. K., Utreja, S., Neelam, N., Roy, A., De, S., & Panja, S. (2020) · MAPAN · doi:10.1007/s12647-020-00397-y · Cited by 20
Zuo, F., Chen, Z., Hu, L., Chen, J., Jin, Y., & Wu, G. (2020) · Journal of Lightwave Technology · doi:10.1109/jlt.2020.3043340 · Cited by 20
Xiao, R., Xu, Y., Wang, Y., Sun, H., & Chen, Q. (2022) · Applied Physics B · doi:10.1007/s00340-022-07938-0 · Cited by 20
Tang, Z.-M., Yu, Y., Sahoo, B. K., Dong, C., Yang, Y., & Zou, Y. (2023) · Physical Review A · doi:10.1103/physreva.107.053111 · Cited by 20
Transportable strontium lattice clock with 4 × 10 − 19 blackbody radiation shift uncertainty
Nosske, I., Vishwakarma, C., Lücke, T., Rahm, J., Poudel, N., Weyers, S., Benkler, E., Dörscher, S., & Lisdat, C. (2025) · Quantum Science and Technology · doi:10.1088/2058-9565/ae1161 · Cited by 19
Self-citationCompact Transportable Optical Standard Based on a Single 171Yb+ Ion (“YBIS” Project)
Semerikov, I. A., Khabarova, K. Y., Zalivako, I. V., Borisenko, A. S., & Kolachevsky, N. (2018) · Bulletin of the Lebedev Physics Institute · doi:10.3103/s1068335618110039 · Cited by 19
Robust optical frequency dissemination with a dual-polarization coherent receiver
Clivati, C., Savio, P., Abrate, S., Curri, V., Gaudino, R., Pizzocaro, M., & Calonico, D. (2020) · Optics Express · doi:10.1364/oe.378602 · Cited by 19
Self-citationDual-Mode Operation of an Optical Lattice Clock Using Strontium and Ytterbium Atoms
Akamatsu, D., Kobayashi, T., Hisai, Y., Tanabe, T., Hosaka, K., Yasuda, M., & Hong, F.-L. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2819888 · Cited by 19
“agrees with a weighted average of previous experimental results [18-21] within our measurement uncertainty.”
MethodResultBarbieri, P., Clivati, C., Pizzocaro, M., Levi, F., & Calonico, D. (2019) · Metrologia · doi:10.1088/1681-7575/ab2b0f · Cited by 18
“In the last two decades, optical combs became a fundamental tool in experimental physics, finding applications beyond optical [1, 2] and microwave [3] frequency metrology.”
Self-citationNovel repumping on 3P0 → 3D1 for Sr magneto-optical trap and Landé g factor measurement of 3D1
Zhang, S., Ramchurn, P., Menchetti, M., Ubaid, Q. H., Jones, J. M., Bongs, K., & Singh, Y. (2020) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/abbe2c · Cited by 19
Sub-kelvin temperature management in ion traps for optical clocks
Nordmann, T., Didier, A., Doležal, M., Balling, P., Burgermeister, T., & Mehlstäubler, T. E. (2020) · Review of Scientific Instruments · doi:10.1063/5.0024693 · Cited by 18
Branching Optical Frequency Transfer With Enhanced Post Automatic Phase Noise Cancellation
Xue, R., Hu, L., Shen, J., Chen, J., & Wu, G. (2021) · Journal of Lightwave Technology · doi:10.1109/jlt.2021.3076182 · Cited by 18
“This optical-frequency transfer capability was developed for optical clock comparison and timekeeping [9], [10], [11], [12], [13].”
The MOCAST+ Study on a Quantum Gradiometry Satellite Mission with Atomic Clocks
Migliaccio, F., Reguzzoni, M., Rosi, G., Braitenberg, C., Tino, G. M., Sorrentino, F., Mottini, S., Rossi, L., Koç, Ö., Batsukh, K., et al. (2023) · Surveys in Geophysics · doi:10.1007/s10712-022-09760-x · Cited by 18
Embedded control system for mobile atom interferometers
Malek, B. S., Pagel, Z., Wu, X., & Müller, H. (2019) · Review of Scientific Instruments · doi:10.1063/1.5083981 · Cited by 18
Phase noise of frequency doublers in optical clock lasers
Herbers, S., Dörscher, S., Benkler, E., & Lisdat, C. (2019) · Optics Express · doi:10.1364/oe.27.023262 · Cited by 18
Self-citationSnowmass 2021: Quantum Sensors for HEP Science -- Interferometers, Mechanics, Traps, and ClocksPreprint
Buchmueller, O. L., Carney, D., Cecil, T., Ellis, J. R., Ruíz, R. F. G., Geraci, A. A., Hanneke, D., Hogan, J. M., Hutzler, N. R., Jayich, A. M., et al. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2203.07250 · Cited by 18
Embedded Digital Phase Noise Analyzer for Optical Frequency Metrology
Donadello, S., Bertacco, E. K., Calonico, D., & Clivati, C. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3288255 · Cited by 17
“potential [1], [2]; optically coherent frequency combs suitable”
BackgroundSelf-citationExcited-Band Coherent Delocalization for Improved Optical Lattice Clock Performance
Siegel, J. L., McGrew, W. F., Hassan, Y. S., Chen, C.-C., Beloy, K., Grogan, T., Zhang, X., & Ludlow, A. D. (2024) · Physical Review Letters · doi:10.1103/physrevlett.132.133201 · Cited by 17
Collinear Three-Photon Excitation of a Strongly Forbidden Optical Clock Transition
Carman, S. P., Rudolph, J., Garber, B. E., de Graaff, M. J. V., Swan, H., Jiang, Y., Nantel, M. K. T., Abe, M., Barcklay, R. L., & Hogan, J. M. (2025) · Physical Review X · doi:10.1103/qk3v-46y8 · Cited by 18
“Narrow optical transitions to long-lived atomic states are essential for many applications in metrology [1–3], precision timekeeping [4–6], and tests of fundamental physics [7–10].”
Precision measurements with cold atoms and trapped ions*
Zhang, Q., Wang, Y., Zhu, C., Wang, Y., Zhang, X., Gao, K., & Zhang, W. (2020) · Chinese Physics B · doi:10.1088/1674-1056/aba9c6 · Cited by 17
Ultra-Wideband Free-Space Optical Phase Stabilization
Dix-Matthews, B. P., Gozzard, D. R., Karpathakis, S., Gravestock, C., & Schediwy, S. (2021) · IEEE Communications Letters · doi:10.1109/lcomm.2021.3053943 · Cited by 17
“The stable transmission of coherent reference signals over FSO channels is important to many scientific applications [10]–[13].”
BackgroundImproved frequency ratio measurement with 87 Sr and 171 Yb optical lattice clocks at NMIJ
Hisai, Y., Akamatsu, D., Kobayashi, T., Hosaka, K., Inaba, H., Hong, F.-L., & Yasuda, M. (2021) · Metrologia · doi:10.1088/1681-7575/abc104 · Cited by 17
“The frequency ratio has also been determined via a satellite link [22] and a transportable OLC [13].”
MethodMeasuring Height Difference Using Two-Way Satellite Time and Frequency Transfer
Cheng, P., Shen, W., Sun, X. L., Cai, C., Wu, K., & Shen, Z. (2022) · Remote Sensing · doi:10.3390/rs14030451 · Cited by 17
“Grotti et al. (2018) reported the first field measurement campaign with a 87Sr TOC with an uncertainty of 1.8×10-16 and a 171Yb OAC with an uncertainty of 1.6×10-16.”
BackgroundMethodInfluentialA proof-of-concept model of compact and high-performance 87Sr optical lattice clock for space
Guo, F., Tan, W., Zhou, C.-H., Xia, J., Chen, Y.-X., Liang, T., Liu, Q., Liu, Y., He, D.-J., Zhou, Y.-Z., et al. (2021) · AIP Advances · doi:10.1063/5.0064087 · Cited by 16
Atomic Clock Frequency Ratios with Fractional Uncertainty ≤ 3.2 × 10 − 18
Aeppli, A., Arthur-Dworschack, W. J., Beloy, K., Berry, C. M., Bothwell, T., Folz, A., Fortier, T. M., Grogan, T. M., Hassan, Y. S., Hu, Z., et al. (2026) · Physical Review Letters · doi:10.1103/g865-9mk1 · Cited by 17
Relativistic tidal effects on clock-comparison experiments
Qin, C.-G., Tan, Y.-J., & Shao, C.-G. (2019) · Classical and Quantum Gravity · doi:10.1088/1361-6382/ab01ae · Cited by 16
Passively stable dissemination of ultrastable optical frequency via a noisy field fiber network
Zhang, X., Hu, L., Deng, X., Zang, Q., Jiao, D., Gao, J., Wang, D., Zhou, Q., Liu, J., Xu, G., et al. (2022) · Optics & Laser Technology · doi:10.1016/j.optlastec.2022.108738 · Cited by 16
Phase Noise and Frequency Stability of the Red-Pitaya Internal PLL
Cardenas-Olaya, A., Calosso, C. E., Friedt, J., Micalizio, S., & Rubiola, E. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2883830 · Cited by 16
Relativistic geoid: Gravity potential and relativistic effects
Philipp, D., Hackmann, E., Lämmerzahl, C., & Müller, J. (2020) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.101.064032 · Cited by 16
Atomic Clock Ensemble in Space
Cacciapuoti, L., Busso, A., Jansen, R., Pataraia, S., Peignier, T., Weinberg, S., Crescence, P., Helm, A., Kehrer, J., Koller, S., et al. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012005 · Cited by 16
Self-citationBeating the Ramsey limit on sensing with deterministic qubit control
Hecht, M., Saurav, K., Vlachos, E., Lidar, D. A., & Levenson-Falk, E. M. (2025) · Nature Communications · doi:10.1038/s41467-025-58947-4 · Cited by 16
Shen, Z., Shen, W., Zhang, T., He, L., Cai, Z., Tian, X., & Zhang, P. (2021) · Advances in Space Research · doi:10.1016/j.asr.2021.07.004 · Cited by 15
Highly vibration-resistant sub-Hertz ultra-stable laser passing over 1700 km transport test
Jiao, D., Deng, X., Gao, J., Zhang, L., Xu, G., Liu, T., Dong, R., & Zhang, S. (2023) · Infrared Physics & Technology · doi:10.1016/j.infrared.2023.104608 · Cited by 17
“Optical atomic clocks have reached unprecedented fractional frequency instabilities below the 10 level [1-5], which have made them an indispensable experimental tool in numerous applications, such as fundamental physics tests [6-10], relativistic geodesy [11-14], and redefinition of the unit “second” [15,16].”
BackgroundBASE-STEP: A transportable antiproton reservoir for fundamental interaction studies
Smorra, C., Abbass, F., Schweitzer, D., Bohman, M., Devine, J., Dutheil, Y., Hobl, A., Arndt, B. P., Bauer, B. B., Devlin, J. A., et al. (2023) · Review of Scientific Instruments · doi:10.1063/5.0155492 · Cited by 15
Metadata
- Authors
- Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., Baynes, F. N., Margolis, H. S., Zampaolo, M., Thoumany, P., Pizzocaro, M., Rauf, B., Bregolin, F., Tampellini, A., Barbieri, P., Zucco, M., Costanzo, G. A., Clivati, C., Levi, F., & Calonico, D.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Leibniz University Hannover (DE)
- National Physical Laboratory (GB)
- Istituto Nazionale di Ricerca Metrologica (IT)
- Politecnico di Torino (IT)
- Corresponding author
- Lisdat, Christian
- ORCID
- Venue
- Nature Physics
- Published
- 2018-02-12
- Volume
- 14
- Issue
- 5
- Pages
- 437-441
- ISSN
- 1745-2473 (ISSN-L)
- 1745-2481
- OpenAlex
- W2612253094
- Cited by
- 495
- References
- 63
- Citations by year
- 2026: 37 · 2025: 51 · 2024: 59 · 2023: 62 · 2022: 68 · 2021: 47 · 2020: 78 · 2019: 60 · 2018: 32
- FWCI
- 25.43
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Physics (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion, cc-by-nc-nd)
- PORTO@Iris (submittedVersion, cc-by)
- HAL (submittedVersion, other-oa)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Publication Database GFZ (GFZ German Research Centre for Geosciences) (submittedVersion)
- PORTO Publications Open Repository TOrino (Politecnico di Torino) (submittedVersion, cc-by)
- arXiv (Cornell University)
- Funders
- European Association of National Metrology Institutes (SIB55-ITOC)
- European Commission
- Deutsche Forschungsgemeinschaft (CRC 1128 (“geo-Q”, CRC 1128)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- relativistic geodesy, field measurement campaign, clock comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.