Geodesy and metrology with a transportable optical clock
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Optical atomic clocks, due to their unprecedented stability1–3 and uncertainty3–6, are already being used to test physical theories7,8 and herald a revision of the International System of Units9,10. However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy11, a major challenge remains: their transformation from highly specialized instruments restricted to national metrology laboratories into flexible devices deployable in different locations12–14. Here, we report the first field measurement campaign with a transportable 87Sr optical lattice clock12. We use it to determine the gravity potential difference between the middle of a mountain and a location 90 km away, exploiting both local and remote clock comparisons to eliminate potential clock errors. A local comparison with a 171Yb lattice clock15 also serves as an important check on the international consistency of independently developed optical clocks. This campaign demonstrates the exciting prospects for transportable optical clocks. An atomic clock has been deployed on a field measurement campaign to determine the height of a mountain location 1,000 m above sea level, returning a value that is in good agreement with state-of-the-art geodesy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Present-day optical clocks and frequency links have already demonstrated geopotential (height) comparisons at the few-centimetre level [7, 14, 27]”
From Chapter 1 Theoretical background (1996) · cites this paper as [7]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Within this project, a proof-of-principle experiment of chronometric geodesy was done by comparing two optical clocks separated by a height difference of around 1000 m, using an optical fibre link [61].”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [61]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Chronometric leveling with a transportable optical clock has first been realized with a 87 Sr lattice clock [24] between Modane (France) and Torino (Italy), albeit with a moderate fractional frequency uncertainty of 1 . 9 × 10 -15 [21].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [21]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 1×
“The influence of BBR on the clock frequency has been discussed elsewhere 3,4,34–36 .”
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572 · cited 1×
“The atoms are then trapped in one-dimensional optical lattices operating at the magic wavelengths 31 λ Ybmagic ≈ 759 nm and λ Srmagic ≈ 813 nm, which to first order give a zero differential light shift between the 1 S 0 and 3 P 0 states.”
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460 · cited 6×
“Its path was equipped with two dedicated bidirectional erbium-doped fibre amplifiers that allowed a phase stable signal to be generated at LSM through the Doppler noise cancellation technique 17,18 .”
InfluentialSelf-citationUltrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Lemke, N., Ludlow, A., Barber, Z., Fortier, T., Diddams, S., Jiang, Y., Jefferts, S., Heavner, T., Parker, T., & Oates, C. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.063001 · Cited by 274
Research works printed but not linked: 3
- Vermeer, M. Chronometric levelling. Rep. Finn. Geod. Inst. 83, 2 (1983).
- Denker, H. in Sciences of Geodesy – II (ed. Xu, G.) Ch. 5 (Springer, 2013).
- JCGM (BIPM, IEC, IFCC, ILAC, ISO, IUPAC, IUPAP and OIML) Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement Vol. 100 (International Organization for Standardization, 2008); http://www.bipm.org/utils/common/documents/jcgm/JCGM_100_2008_E.pdf
Cited by
Items 201–300 of 559
Shen, W., Sun, X. L., Cai, C., Wu, K., & Shen, Z. (2019) · Terrestrial Atmospheric and Oceanic Sciences · doi:10.3319/tao.2018.07.09.02 · Cited by 15
“Later Lisdat et al. (2016) and Grotti et al. (2018) successively provided relevant experimental results which confirmed the OFFT approach (Shen and Peng 2012; Shen 2013a, b; Shen et al. 2018b).”
ResultWDM-Based Fiber-Optic Time Synchronization Without Requiring Link Calibration
Zuo, F., Chen, Z., Hu, L., Chen, J., & Wu, G. (2020) · IEEE Access · doi:10.1109/access.2020.3003702 · Cited by 15
“INTRODUCTION High precision fiber-optic time synchronization has attracted extensive research interest over the last two decades in the applications of metrology, telecommunication, navigation and atomic timescales development, where time deviation with the order of pico-second are required, because of fiber-optic’s u…”
BackgroundBrazhnikov, D. V., Ignatovich, S. M., Mesenzova, I. S., Михайлов, А. М., Boudot, R., & Skvortsov, M. N. (2020) · Quantum Electronics · doi:10.1070/qel17433 · Cited by 15
The expanding role of National Metrology Institutes in the quantum era
Tzalenchuk, A. Y., Spethmann, N., Prior, T. J., Hendricks, J. H., Pan, Y., Bubanja, V., Temporão, G. P., Yu, D.-H., Ilić, D., & Goldstein, B. L. (2022) · Nature Physics · doi:10.1038/s41567-022-01659-z · Cited by 15
Hu, L., Xue, R., Cao, X., Liu, J., Wu, K., Wu, G., & Chen, J. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3191656 · Cited by 14
“Overall, the system performance in terms of the phase noise PSDs, fractional frequency instabilities and uncertainty results are all suitable for the optical frequency transfer application for the state-of-the-art optical atomic clocks [1], [2], [3], [4], [5].”
BackgroundQin, C.-G., Liu, T., Dai, X.-Y., Guo, P., Huang, W., Liu, X., Tan, Y.-J., & Shao, C.-G. (2024) · Classical and Quantum Gravity · doi:10.1088/1361-6382/ad4ae2 · Cited by 14
“Atomic clocks, based on quantum transitions, provide the best available references for time and frequency, with stability and uncertainty levels reaching 10 − 18 and even 10 − 19 [29–34].”
10 −15 -level laser stabilization down to fiber thermal noise limit using self-homodyne detection
Jeon, I., Jeong, W., Ahn, C., & Kim, J. (2025) · Optics Letters · doi:10.1364/ol.541281 · Cited by 14
“There is an increasing demand for ultra-stable laser sources that can be used in non-laboratory environments such as atmospheric and gas sensing [1,2], transportable lattice clock [3,4], and earthquake (moonquake) detection [5–7].”
BackgroundA 780 nm optical frequency standard based on diffuse laser cooled 87Rb atoms
Guan, X., Zhang, J., Gao, X., Wang, Y., Shi, T., & Chen, J. (2025) · Applied Physics Letters · doi:10.1063/5.0250471 · Cited by 15
Obaze-Adeleke, A. C., Semon, B., & Bandi, T. (2025) · Photonics · doi:10.3390/photonics12050513 · Cited by 14
“As optical clocks advance as the leading frequency standards, researchers have focused on their miniaturization [63,109,110] for more compact, transportable, and out-of-the-lab use [11,111–113].”
Coherent Optical Frequency Transfer via a 490 km Noisy Fiber Link
Zhang, X., Deng, X., Zang, Q., Jiao, D., Gao, J., Wang, D., Zhou, Q., Liu, J., Xu, G., Dong, R., et al. (2022) · Chinese Physics Letters · doi:10.1088/0256-307x/39/4/044201 · Cited by 14
Coherent fiber links operated for years: effect of missing data
Tønnes, M., Schüller, F., Cantin, E., Lopez, O., Targat, R. L., Amy‐Klein, A., & Pottie, P.-É. (2022) · Metrologia · doi:10.1088/1681-7575/ac938e · Cited by 14
Optical frequency divider: Capable of measuring optical frequency ratio in 22 digits
Shi, H., Jiang, Y., Yao, Y., Li, B., Wang, C., Yu, H., & Ma, L. (2023) · APL Photonics · doi:10.1063/5.0165602 · Cited by 14
Recent Advances Concerning the 87Sr Optical Lattice Clock at the National Time Service Center
Wang, Y., Lu, X., Lu, B., Kong, D., & Chang, H. (2018) · Applied Sciences · doi:10.3390/app8112194 · Cited by 15
Passive Optical Phase Stabilization on a Ring Fiber Network
Hu, L., Tian, X., Wang, L., Wu, G., & Chen, J. (2020) · Journal of Lightwave Technology · doi:10.1109/jlt.2020.3006091 · Cited by 14
“dark matter, chronometric geodesy [11], and gravitational waves [12]–[14].”
BackgroundQuantum sensing using multiqubit quantum systems and the Pauli polytope
Avdic, I., Sager-Smith, L. M., Ghosh, I., Wedig, O. C., Higgins, J. S., Engel, G. S., & Mazziotti, D. A. (2023) · Physical Review Research · doi:10.1103/physrevresearch.5.043097 · Cited by 13
Benefit of classical leveling for geoid-based vertical reference frames
Gerlach, C., & Rummel, R. (2024) · Journal of Geodesy · doi:10.1007/s00190-024-01849-y · Cited by 13
“• Chronometric leveling: Determine potential differences between stations by clock comparisons exploiting the relativistic gravitational frequency redshift, see e.g., Grotti et al. (2018).”
Lu+ optical frequency references with accuracy verified at the 19th digit
Arnold, K. J., Lee, M. D. K., Zhao, Q., Qin, Q., Zhang, Z., Jayjong, N., & Barrett, M. D. (2026) · Nature · doi:10.1038/s41586-026-11072-8 · Cited by 16
“Below 10 −18 testing of uncertainty budgets thus requires comparison of references at the same location, with inter-institute validation at this level only possible through transportable references 46 .”
Optimal binary gratings for multi-wavelength magneto-optical traps
Burrow, O. S., Fasano, R., Brand, W., Wright, M. W., Li, W., Ludlow, A. D., Riis, E., Griffin, P. F., & Arnold, A. S. (2023) · Optics Express · doi:10.1364/oe.498606 · Cited by 13
Generation of a precise time scale assisted by a near-continuously operating optical lattice clock
Kobayashi, T., Akamatsu, D., Hosaka, K., Hisai, Y., Nishiyama, A., Kawasaki, A., Wada, M., Inaba, H., Tanabe, T., Suzuyama, T., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.064015 · Cited by 13
Yuan, Y., Cui, K., Liu, D., Yuan, J., Cao, J. Z., Wang, D., Chao, S., Shu, H., & Huang, X.-R. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.044052 · Cited by 13
Noise characterization of an ultra-stable laser for optical clocks
Wang, Z., Ma, Z., Wei, W., Chang, J., Zhang, J., Wu, Q., Yuan, W. H., Deng, K., Lu, Z. H., & Zhang, J. (2024) · Review of Scientific Instruments · doi:10.1063/5.0204016 · Cited by 13
Magic polarization for cancellation of light shifts in two-photon optical clocks
Jackson, S., & Vutha, A. C. (2019) · Physical Review A · doi:10.1103/physreva.99.063422 · Cited by 13
Observations of coherence de Broglie wavesPreprint
Byoung Seung, H. A. M. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2007.04738 · Cited by 13
An integrated high-flux cold atomic beam source for strontium
Li, J., Jia, Z.-P., Liu, P., Liu, X., Wang, D., Kong, D.-Q., Li, S.-M., Cui, X.-Y., Dai, H.-N., Chen, Y.-A., et al. (2023) · Review of Scientific Instruments · doi:10.1063/5.0162128 · Cited by 12
Probing new forces with nuclear clocks
Cedric Delaunay, B., Lee, S. J., Ozeri, R., Perez, G., Ratzinger, W., & Yu, B. (2025) · Physical review. D/Physical review. D. · doi:10.1103/gw1d-hbxj · Cited by 12
“Since realizing an atomic–or even more so, a nuclear– clock in space presents multiple technological challenges, one may consider a ground-based transportable version, similar to the setup in [57], accompanied by another optical clock for comparison.”
Quantum Signatures of Proper Time in Optical Ion Clocks
Sorci, G., Foo, J., Leibfried, D. G., Sanner, C., & Pikovski, I. (2026) · Physical Review Letters · doi:10.1103/qhj9-pc2b · Cited by 13
Cai, C., Shen, W., Shen, Z., & Xu, W. S. (2020) · IEEE Access · doi:10.1109/access.2020.3036988 · Cited by 12
“The CTC technique is based on continuously comparing the change in time difference between a fixed clock with a transportable clock [6].”
MethodLow power consumption grating magneto-optical trap based on planar elements
Yu, Z., Zhu, Y., Yao, M., Feng, Q. C., Chen, L., Zou, C., Duan, J., & Liu, X. (2024) · Optics Express · doi:10.1364/oe.518268 · Cited by 12
“The magneto-optical trap (MOT) is a general and robust approach for cooling and trapping atoms and is widely applied in quantum standards and sensors [1-7].”
BackgroundLu, X., Guo, F., Liu, Y., Xia, J., Zhao, G.-D., Chen, Y.-X., Wang, Y., Lu, B., & Chang, H. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.024042 · Cited by 12
Geopotential Difference Measurement Using Two Transportable Optical Clocks’ Frequency Comparisons
Liu, D., Wu, L. F., Xiong, C., & Bao, L. (2024) · Remote Sensing · doi:10.3390/rs16132462 · Cited by 12
Distributed Bragg reflector lasers emitting between 696 and 712 nm
Wenzel, H., Arar, B., Maaßdorf, A., Fricke, J., Martin, D., Zink, C., Schiemangk, M., Wicht, A., Weyers, M., & Knigge, A. C. (2022) · Electronics Letters · doi:10.1049/ell2.12645 · Cited by 12
Weakly gravitating isotropic waveguides
Beig, R., Chruściel, P. T., Hilweg, C., Kornreich, P., & Walther, P. J. (2018) · Classical and Quantum Gravity · doi:10.1088/1361-6382/aae873 · Cited by 12
“Other experiments use optical fibers as a link in order to perform frequency comparisons of clocks located at different gravitational potentials [6, 7].”
MethodPortable Frequency Stabilized Lasers for Quantum Technologies Using Digital Techniques
Chau, H. K., Bridges, C., & Nisbet-Jones, P. B. R. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3285974 · Cited by 11
“environments [16], [17], [21], [22], [23], [24], but terrestrial environments can limit measurement type and sensitivity.”
BackgroundSelf-injection locked laser via a hollow-core fiber Fabry–Perot resonator
Feng, Z., Ding, M., Komanec, M., Zvánovec, S., Zhong, A., Poletti, F., Marra, G., & Slavík, R. (2024) · Photonics Research · doi:10.1364/prj.530157 · Cited by 11
Compact optical frequency standard using a wafer-level MEMS vapor cell
Yang, Q., Hu, Z., Liu, T., Miao, J., Chang, P., Pan, D., Li, Z., Wei, X., & Chen, J. (2025) · Photonics Research · doi:10.1364/prj.563033 · Cited by 13
The Tidal Clock Effects of the Lunisolar Gravitational Field and the Earth’s Tidal Deformation
Qin, C.-G., Tan, Y.-J., & Shao, C.-G. (2020) · The Astronomical Journal · doi:10.3847/1538-3881/abc06f · Cited by 11
“…Global Positioning System (GPS; Nelson 2011; Guang et al. 2018; Weyers et al. 2018), relativistic geodesy and gravimetry (Müller et al. 2008, 2018; Grotti et al. 2018; Kopeikin et al. 2018; Mehlstäubler et al. 2018), searching for dark matter (Derevianko & Pospelov 2014; Roberts et al. 2017),…”
BackgroundValidating frequency transfer via interferometric fiber links for optical clock comparisons
Koke, S., Benkler, E., Kühl, A., & Grosche, G. (2021) · New Journal of Physics · doi:10.1088/1367-2630/ac21a0 · Cited by 12
Optical frequency reference based on a cryogenic silicon resonator
Wiens, E., Kwong, C. J., Müller, T., Bongs, K., Singh, Y., & Schiller, S. (2023) · Optics Express · doi:10.1364/oe.497365 · Cited by 11
Optimal Ramsey interferometry with echo protocols based on one-axis twisting
Scharnagl, M. S., Kielinski, T., & Hammerer, K. (2023) · Physical Review A · doi:10.1103/physreva.108.062611 · Cited by 11
“These in turn pave the way for the search for new physics, such as experiments on Lorentz violation [3], the search for dark matter [4] and for variation of the fundamental constants [5], geodesy [6] and tests of general relativity [7].”
BackgroundAnton, O., Henderson, V., Ros, E. D., Sekulic, I., Burger, S., Schneider, P., & Krutzik, M. (2024) · Machine Learning Science and Technology · doi:10.1088/2632-2153/ad3cb6 · Cited by 11
Cascaded optical frequency transfer over 500-km fiber link using regenerative amplifier*
Deng, X., Jiao, D., Liu, J., Zang, Q., Zhang, X., Wang, D., Gao, J., Dong, R., Liu, T., & Zhang, S. (2020) · Chinese Physics B · doi:10.1088/1674-1056/ab7b4f · Cited by 11
Hoang, A. T., Shen, Z., Wu, K., Ning, A., & Shen, W. (2022) · Remote Sensing · doi:10.3390/rs14194850 · Cited by 11
Hamilton, R., Roberts, B. M., Scholten, S. K., Locke, C. R., Luiten, A. N., Ginges, J. S. M., & Perrella, C. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.054059 · Cited by 11
High Power Distributed Bragg Reflector Lasers at 689.45 nm for Quantum Technology Applications
Pyrlik, C., Goossen-Schmidt, N., Hassan, M. T., Bawamia, A., Fricke, J., Knigge, A. C., Maaßdorf, A., Schiemangk, M., Wenzel, H., & Wicht, A. (2021) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2021.3139433 · Cited by 11
Progress in quantum metrology and applications for optical atomic clocksPreprint
Kaubruegger, R., & Kaufman, A. M. (2025) · arXiv (Cornell University) · doi:10.48550/arxiv.2512.02202 · Cited by 11
Laboratory demonstration of geopotential measurement using transportable optical clocks
Liu, D.-X., Cao, J., Yuan, J.-B., Cui, K.-F., Yuan, Y., Zhang, P., Chao, S.-J., Shu, H.-L., & Huang, X.-R. (2023) · Chinese Physics B · doi:10.1088/1674-1056/ac6337 · Cited by 10
Wu, Y., & Shen, W. (2021) · Advances in Space Research · doi:10.1016/j.asr.2021.05.005 · Cited by 10
Zanon-Willette, T., Wilkowski, D., Lefèvre, R., Taǐchenachev, A. V., & Yudin, V. I. (2022) · Physical Review Research · doi:10.1103/physrevresearch.4.023222 · Cited by 10
Shen, Z., Shen, W., Xu, X., Zhang, S., Zhang, T., He, L., Cai, Z., Xiong, S., & Wang, L. (2023) · Remote Sensing · doi:10.3390/rs15143514 · Cited by 11
Xie, G., Liu, Y., Zhou, L., Zhu, Z., Deng, Z., Luo, D., Gu, C., & Li, W. (2021) · Results in Physics · doi:10.1016/j.rinp.2021.103886 · Cited by 10
Performance of digital servos in an optical frequency transfer network
Hu, L., Xue, R., Wu, G., & Chen, J. (2021) · Review of Scientific Instruments · doi:10.1063/5.0045168 · Cited by 10
Laser-induced thermal source for cold atoms
Hsu, C. C., Larue, R., Kwong, C. C., & Wilkowski, D. (2022) · Scientific Reports · doi:10.1038/s41598-021-04697-4 · Cited by 10
Piotrowski, M., Scarabel, J., Lobino, M., Streed, E. W., & Gensemer, S. D. (2020) · OSA Continuum · doi:10.1364/osac.396290 · Cited by 10
Shen, Z., Shen, W., Zhang, S., Shum, C. K., Zhang, T., He, L., Cai, Z., Xiong, S., & Wang, L. (2023) · Remote Sensing · doi:10.3390/rs15123020 · Cited by 9
Absolute frequency measurements with a robust, transportable 40Ca+ optical clock
Zhang, H., Huang, Y., Zhang, B., Hao, Y., Zeng, M., Chen, Q., Wang, Y., Cao, S., Lin, Y., Fang, Z., et al. (2023) · Metrologia · doi:10.1088/1681-7575/acd05d · Cited by 10
Wu, K., Shen, W., Sun, X. L., Cai, C., & Shen, Z. (2023) · Geo-spatial Information Science · doi:10.1080/10095020.2023.2231515 · Cited by 9
“Some successful clock-transportation experiments have been conducted for testing gravitational redshift or measuring geopotentials via fiber links (Grotti et al. 2018; Lisdat et al. 2016; Takamoto et al. 2020; Takano et al. 2016).”
Ratchet loading and multi-ensemble operation in an optical lattice clock
Hassan, Y. S., Kobayashi, T., Bothwell, T., Siegel, J. L., Hunt, B. D., Beloy, K., Gibble, K., Grogan, T., & Ludlow, A. D. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad6286 · Cited by 9
Compact 852 nm Faraday optical frequency standard
Wang, Z., Liu, Z., Jyoti, Shi, H., Qin, X., Guan, X., Zhang, J., Gao, Z., Shi, T., & Chen, J. (2025) · Applied Physics Letters · doi:10.1063/5.0236915 · Cited by 10
Electro-optic time transfer with femtosecond stability
Olson, J., Rockmore, R., Lemke, N., Krzyzewski, S., & Kasch, B. L. (2025) · Applied Physics Letters · doi:10.1063/5.0240786 · Cited by 10
Nonlinear Networks for Arbitrary Optical Synthesis
Black, J. A., Newman, Z. L., Yu, S., Carlson, D. R., & Papp, S. B. (2023) · Physical Review X · doi:10.1103/physrevx.13.021027 · Cited by 9
Investigation of the 6s6p P03−4f135d6s2 ( J=2 ) Clock Transition in Yb171 Atoms
Qiao, H., Ai, D., Sun, C., Peng, C., Qi, Q.-C., Zhao, C., Luo, L., Jin, T., Zhang, T., Zhou, M., et al. (2024) · Physical Review X · doi:10.1103/physrevx.14.011023 · Cited by 9
Determination of the time-variable geopotential by means of orbiting clocks
Giuliani, S., Tapley, B. D., & Ries, J. (2024) · Journal of Geodesy · doi:10.1007/s00190-024-01868-9 · Cited by 9
“9 × 10 − 15 over 90km (Grotti et al. 2018) and 4 .”
Seishu, Y., & Hasegawa, T. (2019) · Applied Physics B · doi:10.1007/s00340-019-7253-5 · Cited by 9
Gao, K. (2020) · National Science Review · doi:10.1093/nsr/nwaa119 · Cited by 9
Bi‐Frequency Illumination: A Quantum‐Enhanced Protocol
Casariego, M., Omar, Y., & Sanz, M. (2022) · Advanced Quantum Technologies · doi:10.1002/qute.202100051 · Cited by 9
“Namely, in the domain of quantum sensing and metrology [6], we are currently witnessing a boost of applications to a wide spectrum of physical problems: from gravimetry and geodesy [7, 8, 9, 10, 11], gravitational waves [12], clock synchronisation [5, 13], thermometry [14] and biosensors [15, 16, 17, 18, 19], to exper…”
BackgroundXiong, D., Zhu, Q., Wang, J., Zhang, A., Tian, C., Wang, B., He, L., Xiong, Z.-X., & Lyu, B. (2021) · Metrologia · doi:10.1088/1681-7575/abeec3 · Cited by 9
Phase-stabilized free-space link for optical frequency transfer
Yang, J., Kang, H. J., Lee, K., Lee, J., Kim, Y., & Kim, S. (2021) · Optics Communications · doi:10.1016/j.optcom.2021.127481 · Cited by 9
Jin, L., Hang, C., Jiang, Y., Zhu, C., Zheng, Z., Yao, Y., Huang, G., & Ma, L.-S. (2019) · Applied Physics Letters · doi:10.1063/1.5082660 · Cited by 9
Generating 500 mW for laser cooling of strontium atoms by injection locking a high power laser diodePreprint
Schkolnik, V., Williams, J., & Yu, N. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2004.11732 · Cited by 9
Optical system for a strontium optical lattice clock aboard the Chinese Space Station
Xia, J., Wang, W., Zhao, G., Tan, W., Zhou, Y., Guo, F., Liu, Y., He, D., Feng, M., Liang, T., et al. (2025) · Review of Scientific Instruments · doi:10.1063/5.0282958 · Cited by 8
International optical clock comparison using the European optical fiber network
Anonymous, Zyskind, C., Amy‐Klein, A., Benkler, E., Bize, S., Calonico, D., Cantin, E., Chardonnet, C., Clivati, C., Condio, S., et al. (2026) · Physical Review Research · doi:10.1103/l4bh-ryxs · Cited by 8
“…groundbreaking applications, including tests of fundamental physics such as searching for variations of fundamental constants [12, 13], the testing of general relativity [14, 15], chronometric leveling [16, 17], searches for dark matter [18–22] and the generation of optical time scales [23–25].”
Self-citationMeasurement of infrared magic wavelength for an all-optical trapping of 40Ca+ ion clock
Huang, Y., Wang, M., Chen, Z. L., Li, C., Zhang, H., Zhang, B., Tang, L., Shi, T.-Y., Guan, H., & Gao, K. (2024) · New Journal of Physics · doi:10.1088/1367-2630/ad3ea8 · Cited by 8
“At this level of accuracy, optical clocks can play a critical role in redefining the second [6], in searching for variation of fundamental constants [7, 8], and in chronometric leveling [9].”
BackgroundUltra-long-distance distribution of low-phase-noise reference lightwave for optical communications
Sakaguchi, J., Awaji, Y., & Furukawa, H. (2023) · Optics Express · doi:10.1364/oe.492367 · Cited by 8
A compact and robust cooling laser system for an optical strontium lattice clock
Schwarz, R., Dörscher, S., Al-Masoudi, A., Vogt, S., Li, Y., & Lisdat, C. (2019) · Review of Scientific Instruments · doi:10.1063/1.5063552 · Cited by 8
Self-citationAblewski, P., Bober, M., & Zawada, M. (2020) · Metrologia · doi:10.1088/1681-7575/ab63ae · Cited by 8
Strontium optical lattice clock
Yi-Ge, L., & Fang, Z. (2018) · Acta Physica Sinica · doi:10.7498/aps.67.20181097 · Cited by 8
Towards a compact, optically interrogated, cold-atom microwave clock
Elvin, R., Wright, M. W., Lewis, B., Keliehor, B., Bregazzi, A., McGilligan, J. P., Arnold, A. S., Griffin, P. F., & Riis, E. (2019) · Advanced Optical Technologies · doi:10.1515/aot-2020-0022 · Cited by 8
High-power, fiber–laser-based source for magic-wavelength trapping in neutral-atom optical clocks
Eckner, W. J., Young, A. W., Schine, N., & Kaufman, A. M. (2021) · Review of Scientific Instruments · doi:10.1063/5.0057619 · Cited by 8
All-Passive Cascaded Optical Frequency Transfer
Zhang, X., Hu, L., Deng, X., Zang, Q., Liu, J., Jiao, D., Gao, J., Dong, R., Liu, T., Wu, G., et al. (2022) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2022.3164406 · Cited by 8
Transfer of laser frequency from 729 nm to 1.5 µm with precision at the level of 10−20
Fang, P., Sun, H., Wang, Y., Xu, Y., & Chen, Q. (2022) · Chinese Optics Letters · doi:10.3788/col202220.081403 · Cited by 8
Unidirectional two-way optical frequency comparison and its fundamental limitations
Xu, D., Lopez, O., Amy‐Klein, A., & Pottie, P.-É. (2020) · Optics Letters · doi:10.1364/ol.404866 · Cited by 8
Hoang, A. T., Shen, Z., Shen, W., Cai, C., Xu, W. S., Ning, A., & Wu, Y. (2021) · Geodesy and Geodynamics · doi:10.1016/j.geog.2021.08.003 · Cited by 8
Vapor-cell frequency reference for short-wavelength transitions in neutral calcium
Taylor, J. A., Hemingway, B., Hanssen, J. L., Swanson, T. B., & Peil, S. (2018) · Journal of the Optical Society of America B · doi:10.1364/josab.35.001557 · Cited by 8
“Examples include operational clocks used for generation of precise time [5], space clocks for applications such as global navigation [6], and field clocks for relativistic geodesy [7].”
BackgroundEarth-based clocks test general relativity
Bongs, K., & Singh, Y. (2020) · Nature Photonics · doi:10.1038/s41566-020-0654-5 · Cited by 8
Kadum, J. E., Ji, J., Kühl, A., Misera, M., Waterholter, T., & Koke, S. (2023) · APL Photonics · doi:10.1063/5.0133919 · Cited by 7
Hoang, A. T., Shen, Z., & Shen, W. (2023) · IEEE Access · doi:10.1109/access.2023.3308519 · Cited by 7
“[13], [14], [15], [16], [17], [18], [19], [20].”
Improved absolute frequency measurement of 171Yb at NMIJ with uncertainty below 2 × 10 − 16
Kobayashi, T., Nishiyama, A., Hosaka, K., Akamatsu, D., Kawasaki, A., Wada, M., Inaba, H., Tanabe, T., & Yasuda, M. (2025) · Metrologia · doi:10.1088/1681-7575/adb754 · Cited by 7
Semiconductor optical amplifier-based laser system for cold-atom sensors
Kittlaus, E. A., Hunacek, J., Bagheri, M., Nejadriahi, H., Langlois, M., Chiow, S., Yu, N., & Forouhar, S. (2025) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-025-00348-z · Cited by 7
Direct measurement of the P 0 3 clock state natural lifetime in Sr 87
Dolde, J., Ganapathy, D., Zheng, X., Ma, S., Beloy, K., & Kolkowitz, S. (2025) · Physical Review A · doi:10.1103/f6pt-flnt · Cited by 7
Bayesian frequency metrology with optimal Ramsey interferometry in optical atomic clocks
Kielinski, T., & Hammerer, K. (2025) · Reports on Progress in Physics · doi:10.1088/1361-6633/ae213d · Cited by 7
Wang, L., Jiao, W., Hu, L., Chen, J., & Wu, G. (2023) · Optics & Laser Technology · doi:10.1016/j.optlastec.2023.109365 · Cited by 8
REFIMEVE frequency and time network and applications
Cantin, E., Lopez, O., Chardonnet, C., Amy‐Klein, A., Rabault, M., Coget, G., Rosenbusch, P., Ménoret, V., Quintin, N., Tønnes, M., et al. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012031 · Cited by 9
Amazingly precise optical atomic clocks are more than timekeepers
Mann, A. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1809852115 · Cited by 7
Past and Future of Optical Clocks Toward Redefinition of the SI Second
Ido, T. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2874333 · Cited by 8
“This system has already moved around Europe, resulting in a Yb-Sr frequency ratio measurement [19].”
BackgroundDawel, F., Wilzewski, A., Herbers, S., Pelzer, L., Kramer, J., Hild, M. B., Dietze, K., Krinner, L., Spethmann, N., & Schmidt, P. O. (2024) · Optics Express · doi:10.1364/oe.516433 · Cited by 7
“Apart from laboratory experiments in well-controlled environments, a rising number of trans-portable optical clocks [16, 17, 18, 19, 20, 21, 22, 23] also have clock laser stabilisation cavities with instabilities below 1 .”
BackgroundToward a quantum-enhanced strontium optical lattice clock at INRIM
Tarallo, M. G. (2020) · EPJ Web of Conferences · doi:10.1051/epjconf/202023000011 · Cited by 7
Jin, T., Zhang, T., Luo, L., Liu, L., Zhou, M., & Xu, X. (2023) · Measurement · doi:10.1016/j.measurement.2023.112946 · Cited by 6
Compact 780-nm Rb optical clock
Chen, Z., Liu, T., Yang, R., Yang, Q., Wang, Y., Miao, J., Chen, J., Pan, D., Cao, S., Zhang, Z., et al. (2026) · Physical Review Applied · doi:10.1103/6pt5-zgmd · Cited by 7
100 ± Δ t years of quantum uncertainty: From origins to modern insights
Conlon, L. O., Shajilal, B., Zhao, J., Ralph, T. C., Leuchs, G., Andersen, U. L., Assad, S. M., Lam, P. K., & Xiao, Y. (2026) · Reviews of Modern Physics · doi:10.1103/tv7g-jcnk · Cited by 6
Jürß, T., Grosche, G., & Koke, S. (2023) · Photonics Research · doi:10.1364/prj.485899 · Cited by 8
Metadata
- Authors
- Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., Baynes, F. N., Margolis, H. S., Zampaolo, M., Thoumany, P., Pizzocaro, M., Rauf, B., Bregolin, F., Tampellini, A., Barbieri, P., Zucco, M., Costanzo, G. A., Clivati, C., Levi, F., & Calonico, D.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Leibniz University Hannover (DE)
- National Physical Laboratory (GB)
- Istituto Nazionale di Ricerca Metrologica (IT)
- Politecnico di Torino (IT)
- Corresponding author
- Lisdat, Christian
- ORCID
- Venue
- Nature Physics
- Published
- 2018-02-12
- Volume
- 14
- Issue
- 5
- Pages
- 437-441
- ISSN
- 1745-2473 (ISSN-L)
- 1745-2481
- OpenAlex
- W2612253094
- Cited by
- 495
- References
- 63
- Citations by year
- 2026: 37 · 2025: 51 · 2024: 59 · 2023: 62 · 2022: 68 · 2021: 47 · 2020: 78 · 2019: 60 · 2018: 32
- FWCI
- 25.43
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Physics (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion, cc-by-nc-nd)
- PORTO@Iris (submittedVersion, cc-by)
- HAL (submittedVersion, other-oa)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Publication Database GFZ (GFZ German Research Centre for Geosciences) (submittedVersion)
- PORTO Publications Open Repository TOrino (Politecnico di Torino) (submittedVersion, cc-by)
- arXiv (Cornell University)
- Funders
- European Association of National Metrology Institutes (SIB55-ITOC)
- European Commission
- Deutsche Forschungsgemeinschaft (CRC 1128 (“geo-Q”, CRC 1128)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- relativistic geodesy, field measurement campaign, clock comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.