Geodesy and metrology with a transportable optical clock
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Optical atomic clocks, due to their unprecedented stability1–3 and uncertainty3–6, are already being used to test physical theories7,8 and herald a revision of the International System of Units9,10. However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy11, a major challenge remains: their transformation from highly specialized instruments restricted to national metrology laboratories into flexible devices deployable in different locations12–14. Here, we report the first field measurement campaign with a transportable 87Sr optical lattice clock12. We use it to determine the gravity potential difference between the middle of a mountain and a location 90 km away, exploiting both local and remote clock comparisons to eliminate potential clock errors. A local comparison with a 171Yb lattice clock15 also serves as an important check on the international consistency of independently developed optical clocks. This campaign demonstrates the exciting prospects for transportable optical clocks. An atomic clock has been deployed on a field measurement campaign to determine the height of a mountain location 1,000 m above sea level, returning a value that is in good agreement with state-of-the-art geodesy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Present-day optical clocks and frequency links have already demonstrated geopotential (height) comparisons at the few-centimetre level [7, 14, 27]”
From Chapter 1 Theoretical background (1996) · cites this paper as [7]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Within this project, a proof-of-principle experiment of chronometric geodesy was done by comparing two optical clocks separated by a height difference of around 1000 m, using an optical fibre link [61].”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [61]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Chronometric leveling with a transportable optical clock has first been realized with a 87 Sr lattice clock [24] between Modane (France) and Torino (Italy), albeit with a moderate fractional frequency uncertainty of 1 . 9 × 10 -15 [21].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [21]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 1×
“The influence of BBR on the clock frequency has been discussed elsewhere 3,4,34–36 .”
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572 · cited 1×
“The atoms are then trapped in one-dimensional optical lattices operating at the magic wavelengths 31 λ Ybmagic ≈ 759 nm and λ Srmagic ≈ 813 nm, which to first order give a zero differential light shift between the 1 S 0 and 3 P 0 states.”
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460 · cited 6×
“Its path was equipped with two dedicated bidirectional erbium-doped fibre amplifiers that allowed a phase stable signal to be generated at LSM through the Doppler noise cancellation technique 17,18 .”
InfluentialSelf-citationUltrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Lemke, N., Ludlow, A., Barber, Z., Fortier, T., Diddams, S., Jiang, Y., Jefferts, S., Heavner, T., Parker, T., & Oates, C. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.063001 · Cited by 274
Experimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Geopotential measurements with synchronously linked optical lattice clocks
Takano, T., Takamoto, M., Ushijima, I., Ohmae, N., Akatsuka, T., Yamaguchi, A., Kuroishi, Y., Munekane, H., Miyahara, B., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.159 · Cited by 245
Transportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238
Self-citationFrequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
Torge, W., & Müller, J. (2012) · doi:10.1515/9783110250008 · Cited by 220
Sr87Lattice Clock with Inaccuracy below10−15
Boyd, M. M., Ludlow, A. D., Blatt, S., Foreman, S. M., Ido, T., Zelevinsky, T., & Ye, J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.083002 · Cited by 187
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Self-citationTowards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
High-accuracy coherent optical frequency transfer over a doubled 642-km fiber link
Calonico, D., Bertacco, E. K., Calosso, C. E., Clivati, C., Costanzo, G. A., Frittelli, M., Godone, A., Mura, A., Poli, N., Sutyrin, D. V., et al. (2014) · Applied Physics B · doi:10.1007/s00340-014-5917-8 · Cited by 168 · cited 1×
“Its path was equipped with two dedicated bidirectional erbium-doped fibre amplifiers that allowed a phase stable signal to be generated at LSM through the Doppler noise cancellation technique 17,18 .”
Self-citationRabi spectroscopy and excitation inhomogeneity in a one-dimensional optical lattice clock
Blatt, S., Thomsen, J. W., Campbell, G. K., Ludlow, A. D., Swallows, M. D., Martin, M. J., Boyd, M. M., & Ye, J. (2009) · Physical Review A · doi:10.1103/physreva.80.052703 · Cited by 167 · cited 2×
“The lattice of the Yb clock is operated at ν l = 394,798.238 GHz with a trap depth U 0 = 196(4) E r ( E r being the lattice recoil energy) and an atomic temperature of 7(3) µ K as determined by sideband spectroscopy 32 .”
InfluentialUltraprecise Measurement of Optical Frequency Ratios
Stenger, J., Schnatz, H., Tamm, C., & Telle, H. R. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.073601 · Cited by 155
High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.263004 · Cited by 154 · cited 2×
“After averaging (see Methods), we determine the ratio to be R = ν Yb / ν Sr = 1.207,507,039,343,338,41(34).”
InfluentialSelf-citationThe absolute frequency of the87Sr optical clock transition
Campbell, G. K., Ludlow, A. D., Blatt, S., Thomsen, J. W., Martin, M. J., de Miranda, M. H. G., Zelevinsky, T., Boyd, M. M., Ye, J., Diddams, S. A., et al. (2008) · Metrologia · doi:10.1088/0026-1394/45/5/008 · Cited by 151
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Self-citationBlackbody-radiation shift in the Sr optical atomic clock
Safronova, M. S., Porsev, S. G., Safronova, U. I., Kozlov, M. G., & Clark, C. W. (2013) · Physical Review A · doi:10.1103/physreva.87.012509 · Cited by 140
Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the10−17Level
Westergaard, P. G., Lodewyck, J., Lorini, L., Lecallier, A., Burt, E. A., Zawada, M., Millo, J., & Lemonde, P. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.210801 · Cited by 137
Accuracy evaluation of ITCsF2: a nitrogen cooled caesium fountain
Levi, F., Calonico, D., Calosso, C. E., Godone, A., Micalizio, S., & Costanzo, G. A. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/270 · Cited by 134 · cited 1×
“At INRIM, a cryogenic Cs fountain clock 23 and a 171 Yb optical lattice clock 15 served as references.”
Self-citationHigh-Accuracy Measurement of Atomic Polarizability in an Optical Lattice Clock
Sherman, J. A., Lemke, N. D., Hinkley, N., Pizzocaro, M., Fox, R. W., Ludlow, A. D., & Oates, C. W. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.153002 · Cited by 131
Self-citationThe87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129
Self-citationMeasuring the frequency of a Sr optical lattice clock using a 120 km coherent optical transfer
Hong, F.-L., Musha, M., Takamoto, M., Inaba, H., Yanagimachi, S., Takamizawa, A., Watabe, K., Ikegami, T., Imae, M., Fujii, Y., et al. (2009) · Optics Letters · doi:10.1364/ol.34.000692 · Cited by 113
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
A compact, transportable single-ion optical clock with 7.8 × 10−17 systematic uncertainty
Cao, J., Zhang, P., Shang, J., Cui, K., Yuan, J., Chao, S., Wang, S., Shu, H., & Huang, X. (2017) · Applied Physics B · doi:10.1007/s00340-017-6671-5 · Cited by 101
One-Dimensional Optical Lattice Clock with a Fermionic171Yb Isotope
Kohno, T., Yasuda, M., Hosaka, K., Inaba, H., Nakajima, Y., & Hong, F.-L. (2009) · Applied Physics Express · doi:10.1143/apex.2.072501 · Cited by 98
An optical lattice clock with spin-polarized 87Sr atoms
Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Chapelet, F., Abgrall, M., Rovera, G. D., Laurent, P., Rosenbusch, P., et al. (2008) · The European Physical Journal D · doi:10.1140/epjd/e2007-00330-3 · Cited by 96
Development of a strontium optical lattice clock for the SOC mission on the ISS
Bongs, K., Singh, Y., Smith, L., He, W., Kock, O., Świerad, D., Hughes, J., Schiller, S., Alighanbari, S., Origlia, S., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.009 · Cited by 94
Self-citationDenker, H., Timmen, L., Voigt, C., Weyers, S., Peik, E., Margolis, H. S., Delva, P., Wolf, P., & Petit, G. (2018) · Journal of Geodesy · doi:10.1007/s00190-017-1075-1 · Cited by 91
Self-citationAgreement between two88Sr+optical clocks to 4 parts in 1017
Barwood, G. P., Huang, G., Klein, H. A., Johnson, L. A. M., King, S. A., Margolis, H. S., Szymaniec, K., & Gill, P. (2014) · Physical Review A · doi:10.1103/physreva.89.050501 · Cited by 90
Self-citationThe combined satellite gravity field model GOCO05s
Mayer‐Gürr, T., Pail, R., Fecher, R., Gruber, T., & Team Goco (2015) · Publication Database GFZ (GFZ German Research Centre for Geosciences) · Cited by 86
Regional Gravity Field Modeling: Theory and Practical Results
Denker, H. (2013) · Sciences of Geodesy - II · doi:10.1007/978-3-642-28000-9_5 · Cited by 85
Self-citationFrequency ratios of Sr, Yb, and Hg based optical lattice clocks and their applications
Takamoto, M., Ushijima, I., Das, M., Nemitz, N., Ohkubo, T., Yamanaka, K., Ohmae, N., Takano, T., Akatsuka, T., Yamaguchi, A., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.04.003 · Cited by 85
Noise and instability of an optical lattice clock
Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2015) · Physical Review A · doi:10.1103/physreva.92.063814 · Cited by 84
Self-citationMatsubara, K., Hachisu, H., Li, Y., Nagano, S., Locke, C., Nogami, A., Kajita, M., Hayasaka, K., Ido, T., & Hosokawa, M. (2012) · Optics Express · doi:10.1364/oe.20.022034 · Cited by 79
Park, C. Y., Yu, D.-H., Lee, W.-K., Park, S. E., Kim, E. B., Lee, S. K., Cho, J. W., Yoon, T. H., Mun, J., Park, S. J., et al. (2013) · Metrologia · doi:10.1088/0026-1394/50/2/119 · Cited by 74
Grosche, G. (2014) · Optics Letters · doi:10.1364/ol.39.002545 · Cited by 72
Yasuda, M., Inaba, H., Kohno, T., Tanabe, T., Nakajima, Y., Hosaka, K., Akamatsu, D., Onae, A., Suzuyama, T., Amemiya, M., et al. (2012) · Applied Physics Express · doi:10.1143/apex.5.102401 · Cited by 66
First Evaluation and Frequency Measurement of the Strontium Optical Lattice Clock at NIM
Lin, Y.-G., Wang, Q., Li, Y., Meng, F., Lin, B.-K., Zang, E.-J., Sun, Z., Fang, F., Li, T.-C., & Fang, Z.-J. (2015) · Chinese Physics Letters · doi:10.1088/0256-307x/32/9/090601 · Cited by 65
Cavity-stabilized laser with acceleration sensitivity below10−12g−1
Leibrandt, D. R., Bergquist, J. C., & Rosenband, T. (2013) · Physical Review A · doi:10.1103/physreva.87.023829 · Cited by 59
The generalized weighted mean of correlated quantities
Cox, M. G., Eiø, C., Mana, G., & Pennecchi, F. R. (2006) · Metrologia · doi:10.1088/0026-1394/43/4/s14 · Cited by 58 · cited 1×
“We applied a statistical analysis that considers the correlations between the measurements from the different systematic shifts where the covariance matrix of the eight daily measurements is used to calculate a generalized least squares fit for the average 25,45 .”
Pizzocaro, M., Thoumany, P., Rauf, B., Bregolin, F., Milani, G., Clivati, C., Costanzo, G. A., Levi, F., & Calonico, D. (2017) · Metrologia · doi:10.1088/1681-7575/aa4e62 · Cited by 58
Self-citationDirect comparison of optical lattice clocks with an intercontinental baseline of 9000 km
Hachisu, H., Fujieda, M., Nagano, S., Gotoh, T., Nogami, A., Ido, T., Falke, S., Huntemann, N., Grebing, C., Lipphardt, B., et al. (2014) · Optics Letters · doi:10.1364/ol.39.004072 · Cited by 53
Self-citationHachisu, H., Petit, G., Nakagawa, F., Hanado, Y., & Ido, T. (2017) · Optics Express · doi:10.1364/oe.25.008511 · Cited by 53
Yamaguchi, A., Shiga, N., Nagano, S., Li, Y., Ishijima, H., Hachisu, H., Kumagai, M., & Ido, T. (2012) · Applied Physics Express · doi:10.1143/apex.5.022701 · Cited by 51
Voigt, C., Denker, H., & Timmen, L. (2016) · Metrologia · doi:10.1088/0026-1394/53/6/1365 · Cited by 50 · cited 5×
“Separate gravity surveys were carried out around INRIM and LSM, resulting in 36 and 123 new gravity points, respectively.”
InfluentialSelf-citationAkamatsu, D., Inaba, H., Hosaka, K., Yasuda, M., Onae, A., Suzuyama, T., Amemiya, M., & Hong, F.-L. (2014) · Applied Physics Express · doi:10.7567/apex.7.012401 · Cited by 49
Frequency ratio measurement of ^171Yb and ^87Sr optical lattice clocks
Akamatsu, D., Yasuda, M., Inaba, H., Hosaka, K., Tanabe, T., Onae, A., & Hong, F.-L. (2014) · Optics Express · doi:10.1364/oe.22.007898 · Cited by 48
Margolis, H. S., & Gill, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/5/628 · Cited by 40
Self-citationKim, H., Heo, M.-S., Lee, W.-K., Park, C. Y., Hong, H.-G., Hwang, S.-W., & Yu, D.-H. (2017) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.050302 · Cited by 38
Margolis, H. (2014) · Nature Physics · doi:10.1038/nphys2834 · Cited by 33 · cited 1×
“The contribution of fibre frequency transfer to the total fractional uncertainty was assessed to be 3 × 10 –19 by looping back the signal from LSM using a parallel fibre.”
Self-citationHachisu, H., Petit, G., & Ido, T. (2017) · Applied Physics B · doi:10.1007/s00340-016-6603-9 · Cited by 31
Tanabe, T., Akamatsu, D., Kobayashi, T., Takamizawa, A., Yanagimachi, S., Ikegami, T., Suzuyama, T., Inaba, H., Okubo, S., Yasuda, M., et al. (2015) · Journal of the Physical Society of Japan · doi:10.7566/jpsj.84.115002 · Cited by 28
Spin-1/2 Optical Lattice ClockPreprint
Lemke, N., Ludlow, A. D., Barber, Z. W., et al. (2009) · arXiv (Cornell University) · doi:10.48550/arxiv.0906.1219 · Cited by 15
Orthometric correction and normal heights for Italian levelling network: a case study
Barzaghi, R., Betti, B., Carrión, D., Gentile, G., Maseroli, R., & Sacerdote, F. (2014) · Applied Geomatics · doi:10.1007/s12518-013-0121-9 · Cited by 13 · cited 1×
“The GNSS/geoid approach was chosen because the levelling data for Italy are rather old and do not include gravity corrections 43 , and because the GNSS/ geoid approach is not affected by systematic levelling errors.”
A transportable optical lattice clock
Vogt, S., Häfner, S., Grotti, J., Koller, S., Al-Masoudi, A., Sterr, U., & Lisdat, C. (2016) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/723/1/012020 · Cited by 13 · cited 2×
“The physics package is less than 0.6 m 3 in size, and we use laser bread-boards with mechanical stress-resistant fibre couplers 21 .”
InfluentialSelf-citation
Research works printed but not linked: 3
- Vermeer, M. Chronometric levelling. Rep. Finn. Geod. Inst. 83, 2 (1983).
- Denker, H. in Sciences of Geodesy – II (ed. Xu, G.) Ch. 5 (Springer, 2013).
- JCGM (BIPM, IEC, IFCC, ILAC, ISO, IUPAC, IUPAP and OIML) Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement Vol. 100 (International Organization for Standardization, 2008); http://www.bipm.org/utils/common/documents/jcgm/JCGM_100_2008_E.pdf
Cited by
20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
Architecture for the photonic integration of an optical atomic clock
Newman, Z. L., Maurice, V., Drake, T., Stone, J. R., Briles, T. C., Spencer, D. T., Fredrick, C., Li, Q., Westly, D., Ilic, B. R., et al. (2019) · Optica · doi:10.1364/optica.6.000680 · Cited by 636
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citation
Metadata
- Authors
- Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., Baynes, F. N., Margolis, H. S., Zampaolo, M., Thoumany, P., Pizzocaro, M., Rauf, B., Bregolin, F., Tampellini, A., Barbieri, P., Zucco, M., Costanzo, G. A., Clivati, C., Levi, F., & Calonico, D.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Leibniz University Hannover (DE)
- National Physical Laboratory (GB)
- Istituto Nazionale di Ricerca Metrologica (IT)
- Politecnico di Torino (IT)
- Corresponding author
- Lisdat, Christian
- ORCID
- Venue
- Nature Physics
- Published
- 2018-02-12
- Volume
- 14
- Issue
- 5
- Pages
- 437-441
- ISSN
- 1745-2473 (ISSN-L)
- 1745-2481
- OpenAlex
- W2612253094
- Cited by
- 495
- References
- 63
- Citations by year
- 2026: 37 · 2025: 51 · 2024: 59 · 2023: 62 · 2022: 68 · 2021: 47 · 2020: 78 · 2019: 60 · 2018: 32
- FWCI
- 25.43
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Physics (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion, cc-by-nc-nd)
- PORTO@Iris (submittedVersion, cc-by)
- HAL (submittedVersion, other-oa)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Publication Database GFZ (GFZ German Research Centre for Geosciences) (submittedVersion)
- PORTO Publications Open Repository TOrino (Politecnico di Torino) (submittedVersion, cc-by)
- arXiv (Cornell University)
- Funders
- European Association of National Metrology Institutes (SIB55-ITOC)
- European Commission
- Deutsche Forschungsgemeinschaft (CRC 1128 (“geo-Q”, CRC 1128)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- relativistic geodesy, field measurement campaign, clock comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.