Geodesy and metrology with a transportable optical clock
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Optical atomic clocks, due to their unprecedented stability1–3 and uncertainty3–6, are already being used to test physical theories7,8 and herald a revision of the International System of Units9,10. However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy11, a major challenge remains: their transformation from highly specialized instruments restricted to national metrology laboratories into flexible devices deployable in different locations12–14. Here, we report the first field measurement campaign with a transportable 87Sr optical lattice clock12. We use it to determine the gravity potential difference between the middle of a mountain and a location 90 km away, exploiting both local and remote clock comparisons to eliminate potential clock errors. A local comparison with a 171Yb lattice clock15 also serves as an important check on the international consistency of independently developed optical clocks. This campaign demonstrates the exciting prospects for transportable optical clocks. An atomic clock has been deployed on a field measurement campaign to determine the height of a mountain location 1,000 m above sea level, returning a value that is in good agreement with state-of-the-art geodesy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Present-day optical clocks and frequency links have already demonstrated geopotential (height) comparisons at the few-centimetre level [7, 14, 27]”
From Chapter 1 Theoretical background (1996) · cites this paper as [7]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Within this project, a proof-of-principle experiment of chronometric geodesy was done by comparing two optical clocks separated by a height difference of around 1000 m, using an optical fibre link [61].”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [61]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Chronometric leveling with a transportable optical clock has first been realized with a 87 Sr lattice clock [24] between Modane (France) and Torino (Italy), albeit with a moderate fractional frequency uncertainty of 1 . 9 × 10 -15 [21].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [21]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 1×
“The influence of BBR on the clock frequency has been discussed elsewhere 3,4,34–36 .”
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572 · cited 1×
“The atoms are then trapped in one-dimensional optical lattices operating at the magic wavelengths 31 λ Ybmagic ≈ 759 nm and λ Srmagic ≈ 813 nm, which to first order give a zero differential light shift between the 1 S 0 and 3 P 0 states.”
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460 · cited 6×
“Its path was equipped with two dedicated bidirectional erbium-doped fibre amplifiers that allowed a phase stable signal to be generated at LSM through the Doppler noise cancellation technique 17,18 .”
InfluentialSelf-citationUltrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Lemke, N., Ludlow, A., Barber, Z., Fortier, T., Diddams, S., Jiang, Y., Jefferts, S., Heavner, T., Parker, T., & Oates, C. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.063001 · Cited by 274
Research works printed but not linked: 3
- Vermeer, M. Chronometric levelling. Rep. Finn. Geod. Inst. 83, 2 (1983).
- Denker, H. in Sciences of Geodesy – II (ed. Xu, G.) Ch. 5 (Springer, 2013).
- JCGM (BIPM, IEC, IFCC, ILAC, ISO, IUPAC, IUPAP and OIML) Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement Vol. 100 (International Organization for Standardization, 2008); http://www.bipm.org/utils/common/documents/jcgm/JCGM_100_2008_E.pdf
Cited by
Items 501–559 of 559
Demonstration of Real-Time Precision Optical Time Synchronization in a True Three-Node Architecture
Martin, K. W., Bigelow, M. S., Zaki, N., Stuhl, B., Matthews, N., Elgin, J., & Frey, K. (2024) · Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting · doi:10.33012/2024.19591
Clivati, C. (2021) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.5713920
Self-citationA gravitational eye: a method for extracting maximum information from gravitational potentials
de Villiers, G. D., Vovrosh, J., Ridley, K. D., & Holynski, M. (2024) · Measurement Science and Technology · doi:10.1088/1361-6501/ad404d
“The frequency shift can be measured using a transportable optical clock [34].”
MethodTwo-Dimensional Magneto-optical Trap for Producing a Flux of Cold Thulium Atoms
Yaushev, M. O., Mishin, D., Tregubov, D. O., Provorchenko, D. I., Kolachevskiy, N. N., & Golovizin, A. A. (2023) · Журнал Экспериментальной и Теоретической Физики · doi:10.31857/s0044451023080060
Optical-to-microwave phase coherent link at 19th digit accuracy
Rauf, B., Baldoni, I., Wolferstetter, M., Fricke, A., Fischer, M., Giunta, M., & Holzwarth, R. (2024) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2024.sf3n.6
Self-citationPreliminary characterization of a surface electrode Paul trap for frequency metrology
Madunic, J., Groult, L., Achi, B., Lauprêtre, T., Boudrias, A., Roset, P., Soumann, V., Kersalé, Y., Hafiz, M. A., & Lacroûte, C. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012013 · Cited by 1
Wang, B., Yang, Y., Zhang, H., Hu, R., Mao, H., Huang, Y., Gao, K., & Guan, H. (2025) · Sensors · doi:10.3390/s25041044
Kühl, A., Koke, S., Koczwara, A., Waterholter, T., & Grosche, G. (2025) · Annalen der Physik · doi:10.1002/andp.202400414
JIANG, 江. Z.-W., TANG, 唐. Y., HUANG, 黄. P., WANG, 王. B., ZHU, 朱. Q., & Xiong, Z.-X. (2024) · Acta Sinica Quantum Optica · doi:10.3788/jqo20243004.0601
GUO, 郭. C.-Q., JIANG, 江. Z.-W., WANG, 王. B., ZHU, 朱. Q., & Xiong, Z.-X. (2023) · Acta Sinica Quantum Optica · doi:10.3788/jqo20232904.0202
Structure calculations for the low-charged Sn 2 + ion clock
Zheng, H. W., & Tang, L.-Y. (2025) · Physical Review A · doi:10.1103/fmyj-3fyn
Nanosecond Ramsey spectroscopy for Ca beam optical clocks
Chen, J., Liu, T., Miao, J., Ge, Z., Shang, H., Su, Y., Xue, X., Pan, D., & Chen, J. (2025) · npj Quantum Information · doi:10.1038/s41534-025-01114-w
Xác định chênh lệch độ cao giữa hai điểm bằng đồng hồ nguyên tử, một thí nghiệm tại Vũ Hán
Hoàng, A. T., Đậu, K. T., & Shen, W. (2024) · Tạp chí Trắc địa - Bản đồ · doi:10.67484/geogis.62.1001.2024
(2019) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/18972
Time - Frequency transfer and orbit determination systems for space applications
Plumaris, M. (2025) · IRIS Research product catalog (Sapienza University of Rome)
Additive Fertigung hochbeanspruchter Antriebsbauteile
Haubrich, J. (2020) · elib (German Aerospace Center)
THz frequency synthesis in complementary metal-oxide-semiconductor for a chip-scale molecular clock
Mawdsley, J. (2019) · DSpace@MIT (Massachusetts Institute of Technology)
Scientists are hoping to redefine the second – here’s why
Murdin, B. N. (2021) · The Conversation · doi:10.64628/ab.qp6ep35s4
Design of a double-beam MOT chip based on metasurface
Zeng, Y., Zhang, X., Zhao, S., Zhou, F. L., Guo, R., Gao, Y., Yang, B., Ding, C., & Sun, X. (2025) · Physics Letters A · doi:10.1016/j.physleta.2025.131312
Performance limits of a quantum receiver for detecting phase-modulated communication signalsPreprint
Watkins, W. M., Norris, L., & Titum, P. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2602.07123
Operation and optical frequency comparisons with an ytterbium optical lattice clock
Condio, S. (2025) · PORTO@Iris · doi:10.13121/polito/porto/3002616
Trichev, K. K., Borisyuk, P. V., Cherepanov, P. A., Трегубов, Д. О., & Acosta, G. Q. (2025) · Bulletin of the Lebedev Physics Institute · doi:10.3103/s1068335625604650
Realization of the SI Second Defined by Geometric Mean of Multiple Clock TransitionsPreprint
Fang, F., Wang, C., Zuo, Y., & Dai, S. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2603.14858
Fisher information and optimal measurement of Rabi spectrum in optical lattice atomic clocks
韩, R.-S. 弱. H., Tang, G., & Wang, T. (2026) · Acta Physica Sinica · doi:10.7498/aps.75.20251198
MACOR glass-ceramic-based UHV cell for quantum technology applications
Proske, M., Boles, S., Latorre-Bastidas, D., Varma, I., Skanda, R., Hellmig, O., Sengstock, K., Wenzlawski, A., & Windpassinger, P. (2026) · Applied Physics Letters · doi:10.1063/5.0317325
Symmetry-driven zero-frequency-pulling lasing via superradiant sidebands for active optical clocks
Jeon, M., Kim, J., & An, K. (2026) · Physical Review Research · doi:10.1103/q6lc-f9b8
Experiments of orthometric height determination by transportable clock referred to GNSS time
Wang, L., Li, L., Zhang, P., Xu, W., Ning, A., Xu, R., Shen, Z., Wu, K., & Shen, W. (2026) · Advances in Space Research · doi:10.1016/j.asr.2026.04.027
Fresnel zone plates for reconfigurable atomic waveguides
Pike, A. M., Dorne, A., Pickering, L., Jamieson, M., MacCuish, I., Riis, E., Johnson, M. Y. H., Henderson, V. A., Griffin, P. F., & Arnold, A. S. (2026) · Optics Express · doi:10.1364/oe.597259
Laser frequency stabilization using a spatially multiplexed microfabricated Rb vapor cell
Kang, S., Choi, S., Baek, J., Park, S. E., Park, J., Na, Y., Kwon, T. Y., Lee, S.-B., Lee, J. H., Seo, S., et al. (2026) · Applied Physics Express · doi:10.35848/1882-0786/ae5f5a
Redefining the limits of real-time noise cancellation in optical fiber links
McLemore, C. A., Pomponio, M., Nakamura, T., Liu, Y., Hoghooghi, N., Mecozzi, A., & Quinlan, F. (2026) · Optica · doi:10.1364/optica.609658
Seo, M. H., Lee, J. H., Park, Y.-H., Hong, H.-G., Kang, S., Heo, M.-S., Lee, S.-B., Kwon, T. Y., Seo, S., & Park, S. E. (2026) · Optics Express · doi:10.1364/oe.606737
“As these technologies mature toward field-deployable instruments—including transportable optical clocks [7], quantum gravimeters [8], space-borne atom interferometers [9], compact satellite references [10], and portable atom-interferometry laser systems [11]—the demand for compact, robust, and…”
Atomic-referenced Hz-linewidth lasers via fiber interferometric stabilizationPreprint
Ahn, C., Jeong, H., Yang, S., Choi, J., Jeon, I., Moon, H., & Kim, J. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2605.26427
A Zeeman slower based on permanent magnets for optical atomic clocks
Bilicki, S., Morzyński, P., Stellmer, S., & Zawada, M. (2026) · Measurement Science and Technology · doi:10.1088/1361-6501/ae7744
“Recent international efforts have focused on miniaturizing such systems and developing low-power, cost-effective solutions for field applications, including space-based platforms and geophysical measurements [11–13].”
Testing the einstein equivalence principle with atomic clock comparison experiments
Wang, Y.-J., Lu, X.-Y., Li, Z.-G., Hou, S.-J., Zhang, J., Bao, C.-H., Da-hu, C., Gong, Q.-L., & Qin, C.-G. (2026) · Chinese Journal of Physics · doi:10.1016/j.cjph.2026.06.005
Robust Optical Frequency Transfer Against Fiber-Induced Backscattering
Zhang, Y., Zhang, X., Zhou, Q., Yuan, R., 臧, Q. 琦. Z., Liu, T., Dong, R., & Zhang, S. (2026) · Journal of Lightwave Technology · doi:10.1109/jlt.2026.3704954
HUANG, 黄. Y., LEI, 雷. Y., Qi, J., ZHANG, 张. X., WANG, 王. J., & WU, 武. H. (2026) · Acta Sinica Quantum Optica · doi:10.3788/jqo20263202.0601
Toward high-efficiency repumping for ultra-stable Yb inner-shell optical lattice clocks
Feng, S., Jin, T., Zhang, T., Lei, S., Zhang, J., Xia, Y., Chang, H., Liu, X., Zhang, R., Pan, Y., et al. (2026) · Applied Physics Letters · doi:10.1063/5.0325272
Metal-all dielectric optical filters in an Rb hot vapor-based atomic clock
Mirzaei, A., & Hamidi, S. M. (2026) · Optics Express · doi:10.1364/oe.605872
Observation of a sub-Hertz-level Bloch-Siegert shift in a Floquet-engineered optical lattice clock
Anonymous, Lu, X., Chang, H., Zhang, X., & Wang, T. (2026) · Physical Review A · doi:10.1103/mbgj-w2nz
A 1.4 GHz radio frequency source with low phase noise and fast modulation for cold atom experiments
Mingyi, 朱. Z., Peijun, 冯. F., Huang, X., Kong, D.-Q., Jiang, X., Qin, D., Lin, Y., Rao, T., & Jiang, X. Q. (2026) · AIP Advances · doi:10.1063/5.0331604
Hu, R., Ma, Z., Zhang, B., Zhang, H., Wang, Y., Fang, P., Zhang, Y., Hu, Y., Wang, X., Wu, M., et al. (2026) · New Journal of Physics · doi:10.1088/1367-2630/ae9c68
Zhou, Z., Peng, G., Qiu, Z., Hu, L., Wu, G., Chen, J., Zhang, X., Dong, R., Liu, T., & Zhang, S. (2026) · Journal of Lightwave Technology · doi:10.1109/jlt.2026.3728787
Thurtell, T. G. (2026) · UNM’s Digital Repository (University of New Mexico)
Adiabatic Rapid Passage for State Transfer and Sideband Cooling in an 87 Sr Optical Lattice Clock
李, J.-A. 家. L., Cao, J., Hu, C.-Z., Tan, W., Xia, J., 刘, Y.-Y. 艳. L., Zhou, C., & Chang, H. (2026) · Chinese Physics B · doi:10.1088/1674-1056/aea75d
Kobayashi, T., Nishiyama, A., Saito, I., Akamatsu, D., Kawasaki, A., Nagase, S., & Yasuda, M. (2026) · arXiv · doi:10.48550/arxiv.2609.18468
Jian, X., 周驰华, Guodong, Z., Jingjing, 夏. X., Jie, R., Yanyan, L., Li, J., Hu, C., Wei, T., & Hong, C. (2026) · Acta Physica Sinica · doi:10.7498/aps.76.20260803
Interfacing cold atoms with optical waveguides for quantum technologies
Overton, M. (2026) · Nottingham ePrints (University of Nottingham)
High-Accuracy Optical Frequency Metrology: traceability at the 1E-17 level
Barbieri, P. (2020) · PORTO@Iris
Self-citationPrecise Orbit Determination for a Spaceborne Optical Clock Experiment
Kim, Y., Dobbin, M., Scheeres, D., & Axelrad, P. (2026) · Proceedings of the Satellite Division's International Technical Meeting (Online)/Proceedings of the Satellite Division's International Technical Meeting (CD-ROM) · doi:10.33012/2026.20678
An Aubry-André localized optical lattice clockPreprint
Ma, S., Stölzel, A., Christensen, B., Ding, Z., Ganapathy, D., Householder, A., Liu, G., & Kolkowitz, S. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2610.17499
“Optical lattice clocks have been used to probe fundamental physics through measurements of gravitational redshifts over laboratory and geodetic scales [6–9] and searches for ultralight dark matter [10–12].”
Hierarchical Predictive Delay Compensation for Multi-Access Fiber-Optic Time Dissemination
Zhang, R., Dong, J., Wu, G., Yu, S., & Luo, B. (2026) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2026.3743879
Guan, X., Mengyuan, 韩. H., Zhang, J., Gao, X., Wang, Y., Zhuang, W., Shi, T., & 陈景标 (2026) · Physical Review Research · doi:10.1103/8wmd-2s5q
A compact ultracold strontium experimentPreprint
Bertrand, M., Pöpplau, T., Béguin, L., Long, R., & Reichel, J. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2610.29540
Vorobyev, A. K., Khronusova, O., Zhadnov, N. O., Kudeyarov, K. S., Kryuchkov, D. S., Morozov, D., Dmitriev, N. Y., Shitikov, A. E., Chermoshentsev, D. A., Bilenko, I. A., et al. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2610.31866
“The thermal-noise-limited performance of our system at 1–10 s directly supports clock instabilities at the low-10 − 15 / √ τ level, comparable to state-of-the-art transportable clocks [12, 69].”
Velocity-Comb Modulation Transfer Spectroscopy for Laser Frequency Stabilization
Guan, X., Liu, Z., Zhang, J., Qin, X., Gao, X., Mengyuan, 韩. H., Shi, T., & Chen, J. (2026) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/ifcs68110.2026.11738381
Optical clock network tracks tidal variations of the gravity potentialPreprint
Stahl, K., Nosske, I., Vishwakarma, C., Lücke, T., Klose, J., Benkler, E., Kühl, A., Mukherjee, S., Legero, T., Kronjäger, J., et al. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2610.39635 · Cited by 1
“Experiments have progressed from initial demonstrations [2, 9–11] to measuring potential differences with state-of-the-art height uncertainties of few centimetres [14].”
Self-citationSubpicosecond Optical Time Transfer under Simulated Motion with Electro-Optic Frequency CombsPreprint
Matthews, N., Olson, J., Rockmore, R., & Krzyzewski, S. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2611.15763
Xu, W. S., Zhang, P., Li, X., & Song, J. (2026) · Universe · doi:10.3390/universe12110356
Metadata
- Authors
- Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., Baynes, F. N., Margolis, H. S., Zampaolo, M., Thoumany, P., Pizzocaro, M., Rauf, B., Bregolin, F., Tampellini, A., Barbieri, P., Zucco, M., Costanzo, G. A., Clivati, C., Levi, F., & Calonico, D.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Leibniz University Hannover (DE)
- National Physical Laboratory (GB)
- Istituto Nazionale di Ricerca Metrologica (IT)
- Politecnico di Torino (IT)
- Corresponding author
- Lisdat, Christian
- ORCID
- Venue
- Nature Physics
- Published
- 2018-02-12
- Volume
- 14
- Issue
- 5
- Pages
- 437-441
- ISSN
- 1745-2473 (ISSN-L)
- 1745-2481
- OpenAlex
- W2612253094
- Cited by
- 495
- References
- 63
- Citations by year
- 2026: 37 · 2025: 51 · 2024: 59 · 2023: 62 · 2022: 68 · 2021: 47 · 2020: 78 · 2019: 60 · 2018: 32
- FWCI
- 25.43
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Physics (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion, cc-by-nc-nd)
- PORTO@Iris (submittedVersion, cc-by)
- HAL (submittedVersion, other-oa)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Publication Database GFZ (GFZ German Research Centre for Geosciences) (submittedVersion)
- PORTO Publications Open Repository TOrino (Politecnico di Torino) (submittedVersion, cc-by)
- arXiv (Cornell University)
- Funders
- European Association of National Metrology Institutes (SIB55-ITOC)
- European Commission
- Deutsche Forschungsgemeinschaft (CRC 1128 (“geo-Q”, CRC 1128)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- relativistic geodesy, field measurement campaign, clock comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.