Geodesy and metrology with a transportable optical clock
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Optical atomic clocks, due to their unprecedented stability1–3 and uncertainty3–6, are already being used to test physical theories7,8 and herald a revision of the International System of Units9,10. However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy11, a major challenge remains: their transformation from highly specialized instruments restricted to national metrology laboratories into flexible devices deployable in different locations12–14. Here, we report the first field measurement campaign with a transportable 87Sr optical lattice clock12. We use it to determine the gravity potential difference between the middle of a mountain and a location 90 km away, exploiting both local and remote clock comparisons to eliminate potential clock errors. A local comparison with a 171Yb lattice clock15 also serves as an important check on the international consistency of independently developed optical clocks. This campaign demonstrates the exciting prospects for transportable optical clocks. An atomic clock has been deployed on a field measurement campaign to determine the height of a mountain location 1,000 m above sea level, returning a value that is in good agreement with state-of-the-art geodesy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Present-day optical clocks and frequency links have already demonstrated geopotential (height) comparisons at the few-centimetre level [7, 14, 27]”
From Chapter 1 Theoretical background (1996) · cites this paper as [7]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Within this project, a proof-of-principle experiment of chronometric geodesy was done by comparing two optical clocks separated by a height difference of around 1000 m, using an optical fibre link [61].”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [61]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Chronometric leveling with a transportable optical clock has first been realized with a 87 Sr lattice clock [24] between Modane (France) and Torino (Italy), albeit with a moderate fractional frequency uncertainty of 1 . 9 × 10 -15 [21].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [21]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 1×
“The influence of BBR on the clock frequency has been discussed elsewhere 3,4,34–36 .”
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572 · cited 1×
“The atoms are then trapped in one-dimensional optical lattices operating at the magic wavelengths 31 λ Ybmagic ≈ 759 nm and λ Srmagic ≈ 813 nm, which to first order give a zero differential light shift between the 1 S 0 and 3 P 0 states.”
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460 · cited 6×
“Its path was equipped with two dedicated bidirectional erbium-doped fibre amplifiers that allowed a phase stable signal to be generated at LSM through the Doppler noise cancellation technique 17,18 .”
InfluentialSelf-citationUltrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Lemke, N., Ludlow, A., Barber, Z., Fortier, T., Diddams, S., Jiang, Y., Jefferts, S., Heavner, T., Parker, T., & Oates, C. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.063001 · Cited by 274
Research works printed but not linked: 3
- Vermeer, M. Chronometric levelling. Rep. Finn. Geod. Inst. 83, 2 (1983).
- Denker, H. in Sciences of Geodesy – II (ed. Xu, G.) Ch. 5 (Springer, 2013).
- JCGM (BIPM, IEC, IFCC, ILAC, ISO, IUPAC, IUPAP and OIML) Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement Vol. 100 (International Organization for Standardization, 2008); http://www.bipm.org/utils/common/documents/jcgm/JCGM_100_2008_E.pdf
Cited by
20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
Architecture for the photonic integration of an optical atomic clock
Newman, Z. L., Maurice, V., Drake, T., Stone, J. R., Briles, T. C., Spencer, D. T., Fredrick, C., Li, Q., Westly, D., Ilic, B. R., et al. (2019) · Optica · doi:10.1364/optica.6.000680 · Cited by 636
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citationResolving the gravitational redshift across a millimetre-scale atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2022) · Nature · doi:10.1038/s41586-021-04349-7 · Cited by 449
Frequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Entanglement on an optical atomic-clock transition
Pedrozo-Peñafiel, E., Colombo, S., Shu, C., Adiyatullin, A. F., Li, Z., Mendez, E., Braverman, B., Kawasaki, A., Akamatsu, D., Xiao, Y., et al. (2020) · Nature · doi:10.1038/s41586-020-3006-1 · Cited by 275
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“These are important ingredients for actual campaigns outside metrology laboratories and a transportable lattice clock, shown in figure 21, was indeed used for out-of-the-labora-tory experiments with negligible metrological infrastructure (Grotti et al 2018).”
InfluentialSelf-citationTime-reversal-based quantum metrology with many-body entangled states
Colombo, S., Pedrozo-Peñafiel, E., Adiyatullin, A. F., Li, Z., Mendez, E., Shu, C., & Vuletić, V. (2022) · Nature Physics · doi:10.1038/s41567-022-01653-5 · Cited by 231
Roadmap towards the redefinition of the second
Dimarcq, N., Gertsvolf, M., Mileti, G., Bize, S., Oates, C. W., Peik, E., Calonico, D., Ido, T., Tavella, P., Meynadier, F., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad17d2 · Cited by 211
“In addition to their role in the redefinition, the TOCs are essential tools for chronometric levelling and some have already been used for this purpose [62, 87, 90].”
MethodSelf-citationThe missing link in gravitational-wave astronomy: discoveries waiting in the decihertz range
Sedda, M. A., Berry, C. P. L., Jani, K., Amaro‐Seoane, P., Auclair, P., Baird, J., Baker, T., Berti, E., Breivik, K., Burrows, A. S., et al. (2020) · Classical and Quantum Gravity · doi:10.1088/1361-6382/abb5c1 · Cited by 196
Seconds-scale coherence on an optical clock transition in a tweezer array
Norcia, M. A., Young, A. W., Eckner, W. J., Oelker, E., Ye, J., & Kaufman, A. M. (2019) · Science · doi:10.1126/science.aay0644 · Cited by 185
“This capability could be especially transformative for high-performance portable optical clocks [7], where technical constraints limit the performance of the clock laser.”
BackgroundDistributed quantum sensing with mode-entangled spin-squeezed atomic states
Malia, B. K., Wu, Y., Martínez-Rincón, J., & Kasevich, M. A. (2022) · Nature · doi:10.1038/s41586-022-05363-z · Cited by 188
An Atomic-Array Optical Clock with Single-Atom Readout
Madjarov, I. S., Cooper, A., Shaw, A. L., Covey, J. P., Schkolnik, V., Yoon, T. H., Williams, J. R., & Endres, M. (2019) · Physical Review X · doi:10.1103/physrevx.9.041052 · Cited by 104
2000-Times Repeated Imaging of Strontium Atoms in Clock-Magic Tweezer Arrays
Covey, J. P., Madjarov, I. S., Cooper, A., & Endres, M. (2019) · Physical Review Letters · doi:10.1103/physrevlett.122.173201 · Cited by 137
Coherent phase transfer for real-world twin-field quantum key distribution
Clivati, C., Meda, A., Donadello, S., Virzì, S., Genovese, M., Levi, F., Mura, A., Pittaluga, M., Yuan, Z. L., Shields, A. J., et al. (2022) · Nature Communications · doi:10.1038/s41467-021-27808-1 · Cited by 164
“These fibers are part of the Italian Quantum Backbone and carry other services, among which is the dissemination of atomic clock signals to research facilities of the Country [35, 36].”
BackgroundSelf-citationDifferential clock comparisons with a multiplexed optical lattice clock
Zheng, X., Dolde, J., Lochab, V., Merriman, B. N., Li, H., & Kolkowitz, S. (2022) · Nature · doi:10.1038/s41586-021-04344-y · Cited by 150
Towards the optical second: verifying optical clocks at the SI limit
McGrew, W. F., Zhang, X., Leopardi, H., Fasano, R. J., Nicolodi, D., Beloy, K., Yao, J., Sherman, J. A., Schäffer, S. A., Savory, J., et al. (2019) · Optica · doi:10.1364/optica.6.000448 · Cited by 135
Origlia, S., Pramod, M. S., Schiller, S., Singh, Y., Bongs, K., Schwarz, R., Al-Masoudi, A., Dörscher, S., Herbers, S., Häfner, S., et al. (2018) · Physical Review A · doi:10.1103/physreva.98.053443 · Cited by 142
Self-citationQuantum Variational Optimization of Ramsey Interferometry and Atomic Clocks
Kaubruegger, R., Vasilyev, D. V., Schulte, M., Hammerer, K., & Zoller, P. (2021) · Physical Review X · doi:10.1103/physrevx.11.041045 · Cited by 142
A dielectric metasurface optical chip for the generation of cold atoms
Zhu, L., Liu, X., Sain, B., Wang, M., Schlickriede, C., Tang, Y., Deng, J., Li, K., Yang, J., Holynski, M., et al. (2020) · Science Advances · doi:10.1126/sciadv.abb6667 · Cited by 122
Continuous Bose–Einstein condensation
Chen, C.-C., Escudero, R. G., Minář, J., Pasquiou, B., Bennetts, S., & Schreck, F. (2022) · Nature · doi:10.1038/s41586-022-04731-z · Cited by 122
“Creating such a CW source of matter will benefit applications ranging from geodesy [17, 18], to tests of Einstein’s equivalence principle [5, 6], gravitational-wave detection [12, 13, 19– 21], and dark-matter and dark-energy searches [22, 23].”
Schioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., et al. (2022) · Nature Communications · doi:10.1038/s41467-021-27884-3 · Cited by 118
Self-citationRoslund, J., Cingöz, A., Lunden, W. D. M., Partridge, G. B., Kowligy, A. S., Roller, F., Sheredy, D., Skulason, G. E., Song, J. P., Abo-Shaeer, J. R., et al. (2024) · Nature · doi:10.1038/s41586-024-07225-2 · Cited by 117
“6, 7), transportable versions of these high-performing clocks 8,9 have limited utility because of their size, environmental sensitivity and cost 10 .”
Fundamental physics with a state-of-the-art optical clock in space
Derevianko, A., Gibble, K., Hollberg, L. W., Newbury, N. R., Oates, C. W., Safronova, M. S., Sinclair, L. C., & Yu, N. (2022) · Quantum Science and Technology · doi:10.1088/2058-9565/ac7df9 · Cited by 110
Femtosecond time synchronization of optical clocks off of a flying quadcopter
Bergeron, H., Sinclair, L. C., Swann, W. C., Khader, I. H., Cossel, K. C., Cermak, M. A., Deschênes, J.-D., & Newbury, N. R. (2019) · Nature Communications · doi:10.1038/s41467-019-09768-9 · Cited by 113
Inner-shell clock transition in atomic thulium with a small blackbody radiation shift
Golovizin, A. A., Fedorova, E., Tregubov, D. O., Sukachev, D., Khabarova, K. Y., Sorokin, V., & Kolachevsky, N. (2019) · Nature Communications · doi:10.1038/s41467-019-09706-9 · Cited by 102
Common-clock very long baseline interferometry using a coherent optical fiber link
Clivati, C., Aiello, R., Bianco, G., Bortolotti, C., De Natale, P., Di Sarno, V., Maddaloni, P., Maccaferri, G., Mura, A., Negusini, M., et al. (2020) · Optica · doi:10.1364/optica.393356 · Cited by 99
Self-citationIn + 115 − Yb + 172 Coulomb Crystal Clock with 2.5 × 10 − 18 Systematic Uncertainty
Hausser, H. N., Keller, J., Nordmann, T., Bhatt, N. M., Kiethe, J., Liu, H., Richter, I. M., von Boehn, M., Rahm, J., Weyers, S., et al. (2025) · Physical Review Letters · doi:10.1103/physrevlett.134.023201 · Cited by 99
Self-citationMiniaturized optical frequency reference for next-generation portable optical clocks
Maurice, V. N., Newman, Z. L., Dickerson, S. M., Rivers, M., Hsiao, J., Greene, P., Mescher, M., Kitching, J. E., Hummon, M. T., & Johnson, C. (2020) · Optics Express · doi:10.1364/oe.396296 · Cited by 94
Prospects and challenges for squeezing-enhanced optical atomic clocks
Schulte, M., Lisdat, C., Schmidt, P. O., Sterr, U., & Hammerer, K. (2020) · Nature Communications · doi:10.1038/s41467-020-19403-7 · Cited by 90
“[11] J.”
BackgroundSelf-citationImproving cold-atom sensors with quantum entanglement: Prospects and challenges
Szigeti, S. S., Hosten, O., & Haine, S. A. (2021) · Applied Physics Letters · doi:10.1063/5.0050235 · Cited by 90
Point-to-point stabilized optical frequency transfer with active optics
Dix-Matthews, B. P., Schediwy, S., Gozzard, D. R., Savalle, E., Esnault, F.-X., Lévèque, T., Gravestock, C., D’Mello, D., Karpathakis, S., Tobar, M. E., et al. (2021) · Nature Communications · doi:10.1038/s41467-020-20591-5 · Cited by 89
Quantum technologies in the telecommunications industry
Martin, V., Brito, J. P., Escribano, C., Menchetti, M., White, C., Lord, A., Wissel, F., Gunkel, M., Gavignet, P., Genay, N., et al. (2021) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-021-00108-9 · Cited by 85
Ohmae, N., Takamoto, M., Takahashi, Y., Kokubun, M., Araki, K., Hinton, A., Ushijima, I., Muramatsu, T., Furumiya, T., Sakai, Y., et al. (2021) · Advanced Quantum Technologies · doi:10.1002/qute.202100015 · Cited by 79
Trapping of single atoms in metasurface optical tweezer arrays
Holman, A., Xu, Y., Sun, X., Wu, J., Wang, M., Zhu, Z., Seo, B., Yu, N., & Will, S. (2026) · Nature · doi:10.1038/s41586-025-09961-5 · Cited by 80
Towards a transportable aluminium ion quantum logic optical clock
Hannig, S., Pelzer, L., Scharnhorst, N., Kramer, J., Stepanova, M., Xu, Z. T., Spethmann, N., Leroux, I. D., Mehlstäubler, T. E., & Schmidt, P. O. (2019) · Review of Scientific Instruments · doi:10.1063/1.5090583 · Cited by 76
Planar-Integrated Magneto-Optical Trap
Chen, L., Huang, C.-J., Xu, X., Zhang, Y., Ma, D.-Q., Lu, Z., Wang, Z.-B., Chen, G.-J., Zhang, J.-Z., Tang, H. X., et al. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.034031 · Cited by 70
A pyramid MOT with integrated optical cavities as a cold atom platform for an optical lattice clock
Bowden, W., Hobson, R., Hill, I. R., Vianello, A., Schioppo, M., Silva, A., Margolis, H. S., Baird, P. E. G., & Gill, P. (2019) · Scientific Reports · doi:10.1038/s41598-019-48168-3 · Cited by 55
Self-citationIntercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64
Self-citationNarrow-line Cooling and Determination of the Magic Wavelength of Cd
Yamaguchi, A., Safronova, M. S., Gibble, K., & Katori, H. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.113201 · Cited by 65
“Such advanced atomic clocks motivate an optical redefinition of the second [6] and open up new applications, such as chronometric leveling [7,8] and laboratory searches for variations of fundamental constants [9,10].”
BackgroundPizzocaro, M., Bregolin, F., Barbieri, P., Rauf, B., Levi, F., & Calonico, D. (2020) · Metrologia · doi:10.1088/1681-7575/ab50e8 · Cited by 63
Self-citationFemtosecond optical two-way time-frequency transfer in the presence of motion
Sinclair, L. C., Bergeron, H., Swann, W. C., Khader, I. H., Cossel, K. C., Cermak, M. A., Newbury, N. R., & Deschênes, J.-D. (2019) · Physical Review A · doi:10.1103/physreva.99.023844 · Cited by 66
Compact 459-nm Cs Cell Optical Frequency Standard with 2.1×10−13/τ Short-Term Stability
Miao, J., Shi, T., Zhang, J., & Chen, J. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.024034 · Cited by 63
Optical frequency ratio of a 171Yb+ single-ion clock and a 87Sr lattice clock
Dörscher, S., Huntemann, N., Schwarz, R., Lange, R., Benkler, E., Lipphardt, B., Sterr, U., Peik, E., & Lisdat, C. (2021) · Metrologia · doi:10.1088/1681-7575/abc86f · Cited by 53
Self-citationLattice-induced photon scattering in an optical lattice clock
Dörscher, S., Schwarz, R., Al-Masoudi, A., Falke, S., Sterr, U., & Lisdat, C. (2018) · Physical Review A · doi:10.1103/physreva.97.063419 · Cited by 60
Self-citationCold atoms in space: community workshop summary and proposed road-map
Alonso, I., Alpigiani, C., Altschul, B., Araújo, H. M., Arduini, G., Arlt, J., Badurina, L., Balaž, A., Bandarupally, S., Barish, B. C., et al. (2022) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-022-00147-w · Cited by 61
“These setups are developed for space applications [40], and have been used in a geodetic context [120, 121] or to test fundamental aspects of physics [80].”
BackgroundSelf-citationHobson, R., Bowden, W., Vianello, A., Silva, A., Baynham, C. F. A., Margolis, H. S., Baird, P. E. G., Gill, P., & Hill, I. R. (2020) · Metrologia · doi:10.1088/1681-7575/abb530 · Cited by 58
Self-citationCold-atom clock based on a diffractive optic
Elvin, R., Hoth, G. W., Wright, M., Lewis, B., McGilligan, J. P., Arnold, A. S., Griffin, P. F., & Riis, E. (2019) · Optics Express · doi:10.1364/oe.378632 · Cited by 57
Optically synchronized fibre links using spectrally pure chip-scale lasers
Brodnik, G. M., Harrington, M. W., Dallyn, J. H., Bose, D., Zhang, W., Stern, L., Morton, P. A., Behunin, R. O., Papp, S. B., & Blumenthal, D. J. (2021) · Nature Photonics · doi:10.1038/s41566-021-00831-w · Cited by 58
Atomic clock ensemble in space
Cacciapuoti, L., & Salomon, C. (2011) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/327/1/012049 · Cited by 56
A strontium lattice clock with both stability and uncertainty below 5 × 10 − 18
Li, J., Cui, X.-Y., Jia, Z.-P., Kong, D.-Q., Yu, H.-W., Zhu, X.-Q., Liu, X., Wang, D., Zhang, X., Huang, X.-Y., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad1a4c · Cited by 58
Optical frequency distribution using laser repeater stations with planar lightwave circuits
Akatsuka, T., Goh, T., Imai, H., Oguri, K., Ishizawa, A., Ushijima, I., Ohmae, N., Takamoto, M., Katori, H., Hashimoto, T., et al. (2020) · Optics Express · doi:10.1364/oe.383526 · Cited by 55
Optical frequency transfer over submarine fiber links
Clivati, C., Tampellini, A., Mura, A., Levi, F., Marra, G., Galea, P., Xuereb, A., & Calonico, D. (2018) · Optica · doi:10.1364/optica.5.000893 · Cited by 55
Self-citationAdvanced Satellite-Based Frequency Transfer at the 10−16 Level
Fujieda, M., Yang, S.-H., Gotoh, T., Hwang, S.-W., Hachisu, H., Kim, H., Lee, Y. K., Tabuchi, R., Ido, T., Lee, W.-K., et al. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2821159 · Cited by 55
Metasurface holographic optical traps for ultracold atoms
Huang, X., Yuan, W., Holman, A., Kwon, M., Masson, S. J., Gutiérrez-Jáuregui, R., Asenjo-García, A., Will, S., & Yu, N. (2023) · Progress in Quantum Electronics · doi:10.1016/j.pquantelec.2023.100470 · Cited by 55
Geopotential measurement with a robust, transportable Ca+ optical clock
Huang, Y., Zhang, H., Zhang, B., Hao, Y., Guan, H., Zeng, M., Chen, Q., Lin, Y., Wang, Y., Cao, S., et al. (2020) · Physical Review A · doi:10.1103/physreva.102.050802 · Cited by 52
Laser with 10−13 short-term instability for compact optically pumped cesium beam atomic clock
Shang, H., Zhang, T., Miao, J., Shi, T., Pan, D., Zhao, X., Wei, Q., Yang, L., & Chen, J. (2020) · Optics Express · doi:10.1364/oe.381147 · Cited by 52
Optical time-frequency transfer across a free-space, three-node network
Bodine, M. I., Ellis, J. L., Swann, W. C., Stevenson, S. A., Deschênes, J.-D., Hannah, E. D., Manurkar, P., Newbury, N. R., & Sinclair, L. C. (2020) · APL Photonics · doi:10.1063/5.0010704 · Cited by 53
A highly stable monolithic enhancement cavity for second harmonic generation in the ultraviolet
Hannig, S., Mielke, J., Fenske, J.-A., Misera, M., Beev, N., Ospelkaus, C., & Schmidt, P. O. (2018) · Review of Scientific Instruments · doi:10.1063/1.5005515 · Cited by 53
The unit of time: Present and future directions
Bize, S. (2019) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2019.02.002 · Cited by 47
“Recently, one of these devices was used for another proofof-concept experiment [195] again in conjunction with coherent optical fiber link.”
MethodDemonstration of the nearly continuous operation of an 171 Yb optical lattice clock for half a year
Kobayashi, T., Akamatsu, D., Hosaka, K., Hisai, Y., Wada, M., Inaba, H., Suzuyama, T., Hong, F.-L., & Yasuda, M. (2020) · Metrologia · doi:10.1088/1681-7575/ab9f1f · Cited by 50
Absolute frequency measurement of the 171Yb optical lattice clock at KRISS using TAI for over a year
Kim, H., Heo, M.-S., Park, C. Y., Yu, D.-H., & Lee, W.-K. (2021) · Metrologia · doi:10.1088/1681-7575/ac1950 · Cited by 51
“The absolute frequency measurements of the 1S0-3P0 transition of 171Yb have been performed many times by laboratories worldwide by using TAI (International Atomic Time) [13, 25-31], by using a local Cs fountain clock [20, 32], or by using the frequency ratio measurement between different atomic species [17, 33-42].”
Testing gravity with cold-atom clocks in space: The ACES mission
Cacciapuoti, L., Armano, M., Much, R., Sy, O., Helm, A., Hess, M. P., Kehrer, J., Koller, S., Niedermaier, T., Esnault, F.-X., et al. (2020) · The European Physical Journal D · doi:10.1140/epjd/e2020-10167-7 · Cited by 50
Self-citationLow-loss low thermo-optic coefficient Ta2O5 on crystal quartz planar optical waveguides
Zhao, Q., Behunin, R. O., Rakich, P. T., Chauhan, N., Isichenko, A., Wang, J., Hoyt, C., Fertig, C., Lin, M. H., & Blumenthal, D. J. (2020) · APL Photonics · doi:10.1063/5.0024743 · Cited by 48
Measurement of Optical Rubidium Clock Frequency Spanning 65 Days
Lemke, N., Martin, K. W., Beard, R., Stuhl, B., Metcalf, A. J., & Elgin, J. (2022) · Sensors · doi:10.3390/s22051982 · Cited by 48
The CIPM list ‘Recommended values of standard frequencies’: 2021 update
Margolis, H. S., Panfilo, G., Petit, G., Oates, C. W., Ido, T., & Bize, S. (2024) · Metrologia · doi:10.1088/1681-7575/ad3afc · Cited by 48
Self-citationA lab-based test of the gravitational redshift with a miniature clock network
Zheng, X., Dolde, J., Cambria, M. C., Lim, H. M., & Kolkowitz, S. (2023) · Nature Communications · doi:10.1038/s41467-023-40629-8 · Cited by 47
“The measurement of gravitational potential differences between clocks with sub-centimeter resolution is a major goal of relativistic geodesy 15,31 – 34 .”
InfluentialStand-alone vacuum cell for compact ultracold quantum technologies
Burrow, O. S., Osborn, P. F., Boughton, E., Mirando, F., Burt, D. P., Griffin, P. F., Arnold, A. S., & Riis, E. (2021) · Applied Physics Letters · doi:10.1063/5.0061010 · Cited by 47
Systematic evaluation of a 171Yb optical clock by synchronous comparison between two lattice systems
Gao, Q., Zhou, M., Han, C., Li, S., Zhang, S., Yao, Y., Li, B., Qiao, H., Ai, D., Lou, G., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-26365-w · Cited by 47
Dichroic Two-Photon Rubidium Frequency Standard
Perrella, C., Light, P. S., Anstie, J. D., Baynes, F. N., White, R. T., & Luiten, A. N. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.054063 · Cited by 46
Self-citationEntanglement-enhanced optical atomic clocks
Colombo, S., Pedrozo-Peñafiel, E., & Vuletić, V. (2022) · Applied Physics Letters · doi:10.1063/5.0121372 · Cited by 45
“Optical-transition atomic clocks 1–5 are the most accurate sensors developed by humankind, reaching fractional stabilities below 10 (cid:2) 18 .”
BackgroundEfficient Preparation of Dicke States
Yu, J., Muleady, S. R., Wang, Y.-X., Schine, N., Gorshkov, A. V., & Childs, A. M. (2026) · Physical Review Letters · doi:10.1103/9gjk-rgql · Cited by 46
Protocol for Light-Shift Compensation in a Continuous-Wave Microcell Atomic Clock
Hafiz, M. A., Vicarini, R., Passilly, N., Calosso, C. E., Maurice, V. N., Pollock, J. W., Taichenachev, A. V., Yudin, V. I., Kitching, J., & Boudot, R. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.034015 · Cited by 45
“These instruments are exquisite tools to perform fundamental physics tests including geodesy [3,4], Lorentz symmetry testing [5], and dark-matter searching [6].”
MethodOptical atomic clock interrogation using an integrated spiral cavity laser
Loh, W., Reens, D., Kharas, D., Sumant, A., Belanger, C., Maxson, R., Medeiros, A., Setzer, W., Gray, D. J., DeBry, K., et al. (2025) · Nature Photonics · doi:10.1038/s41566-024-01588-8 · Cited by 44
Optical atomic clocks: defining the future of time and frequency metrology
Fortier, T. M., Luiten, A. N., & Margolis, H. S. (2026) · Optica · doi:10.1364/optica.575770 · Cited by 45
Self-citationSI-traceable frequency dissemination at 1572.06 nm in a stabilized fiber network with ring topology
Husmann, D., Bernier, L.-G., Bertrand, M., Calonico, D., Chaloulos, K. S., Clausen, G., Clivati, C., Faist, J., Heiri, E., Hollenstein, U., et al. (2021) · Optics Express · doi:10.1364/oe.427921 · Cited by 43
Self-citationCoherent Optical-Fiber Link Across Italy and France
Clivati, C., Pizzocaro, M., Bertacco, E. K., Condio, S., Costanzo, G. A., Donadello, S., Goti, I., Gozzelino, M., Levi, F., Mura, A., et al. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.054009 · Cited by 44
Self-citationImproved interspecies optical clock comparisons through differential spectroscopy
Kim, M. E., McGrew, W. F., Nardelli, N. V., Clements, E., Hassan, Y. S., Zhang, X., Valencia, J. L., Leopardi, H., Hume, D. B., Fortier, T. M., et al. (2022) · Nature Physics · doi:10.1038/s41567-022-01794-7 · Cited by 43
Real-time phase tracking for wide-band optical frequency measurements at the 20th decimal place
Giunta, M., Hänsel, W., Fischer, M., Lezius, M., Udem, T., & Holzwarth, R. (2020) · Nature Photonics · doi:10.1038/s41566-019-0520-5 · Cited by 41
Ultra-broadband dual-branch optical frequency comb with 10−18instability
Rolland, A., Li, P., Kuse, N., Jiang, J., Cassinerio, M., Langrock, C., & Fermann, M. E. (2018) · Optica · doi:10.1364/optica.5.001070 · Cited by 35
Self-citation13 134-Km Fiber-Optic Time Synchronization
Zuo, F., Xie, K., Hu, L., Chen, J., & Wu, G. (2021) · Journal of Lightwave Technology · doi:10.1109/jlt.2021.3102674 · Cited by 41
A perspective on the future of transportable optical lattice clocks
Takamoto, M., Tanaka, Y., & Katori, H. (2022) · Applied Physics Letters · doi:10.1063/5.0087894 · Cited by 40
Demonstration of a mobile optical clock ensemble at sea
Hilton, A. P., Offer, R. F., Klantsataya, E., Scholten, S. K., Hébert, N. B., Billington, C. J., Locke, C. R., Perrella, C., Nelligan, M., Allison, J. W., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-61140-2 · Cited by 42
“Please either just refer to this as “technology explored in Ref [34]”, or refer to Vector Atomic by name when giving the initial reference in line 87.”
Ohmae, N., Bregolin, F., Nemitz, N., & Katori, H. (2020) · Optics Express · doi:10.1364/oe.391602 · Cited by 36
Self-citationImproving the Q Factor of an Optical Atomic Clock Using Quantum Nondemolition Measurement
Bowden, W., Vianello, A., Hill, I. R., Schioppo, M., & Hobson, R. (2020) · Physical Review X · doi:10.1103/physrevx.10.041052 · Cited by 41
“Our work builds on recent demonstrations with Yb [24] and Sr [25, 26] by applying QND measurement to a fully operational Sr OLC—an exceptionally stable and accurate type of clock [27–30] which is a prime candidate to underpin a future redefinition of the SI second [31] as well as being a sensitive probe for geodesy [3…”
MethodCompact and ultrastable photonic microwave oscillator
Giunta, M., Yu, J., Lessing, M., Fischer, M., Lezius, M., Xie, X., Santarelli, G., Coq, Y. L., & Holzwarth, R. (2020) · Optics Letters · doi:10.1364/ol.385503 · Cited by 39
Ultra-precise optical phase-locking approach for ultralow noise frequency comb generation
Deng, Z., Liu, Y., Zhu, Z., Luo, D., Gu, C., Zhou, L., Xie, G., & Li, W. (2021) · Optics & Laser Technology · doi:10.1016/j.optlastec.2020.106906 · Cited by 39
Short-term stability of Cs microcell-stabilized lasers using dual-frequency sub-Doppler spectroscopy
Gusching, A., Petersen, M., Passilly, N., Brazhnikov, D. V., Hafiz, M. A., & Boudot, R. (2021) · Journal of the Optical Society of America B · doi:10.1364/josab.438111 · Cited by 40
Park, A. J., Trautmann, J., Šantić, N., Klüsener, V., Heinz, A., Bloch, I., & Blatt, S. (2022) · PRX Quantum · doi:10.1103/prxquantum.3.030314 · Cited by 39
Muniz, J. A., Young, D. J., Cline, J. R. K., & Thompson, J. K. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.023152 · Cited by 38
McLemore, C. A., Jin, N., Kelleher, M., Hendrie, J., Mason, D., Luo, Y., Lee, D., Rakich, P. T., Diddams, S. A., & Quinlan, F. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.054054 · Cited by 39
Cs microcell optical reference with frequency stability in the low 10−13 range at 1 s
Gusching, A., Millo, J., Rýger, I., Vicarini, R., Hafiz, M. A., Passilly, N., & Boudot, R. (2023) · Optics Letters · doi:10.1364/ol.485548 · Cited by 38
Seconds-scale coherence in a tweezer-array optical clock
Norcia, M. A., Young, A. W., Eckner, W. J., Oelker, E., Ye, J., & Kaufman, A. M. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1904.10934 · Cited by 30
“This capability could be especially transformative for high-performance portable optical clocks [7], where technical constraints limit the performance of the clock laser.”
BackgroundTransportable interrogation laser system with an instability of mod σy = 3 × 10−16
Häfner, S., Herbers, S., Vogt, S., Lisdat, C., & Sterr, U. (2020) · Optics Express · doi:10.1364/oe.390105 · Cited by 37
Self-citationCoordinated international comparisons between optical clocks connected via fiber and satellite links
Lindvall, T., Pizzocaro, M., Godun, R. M., Abgrall, M., Akamatsu, D., Amy‐Klein, A., Benkler, E., Bhatt, N., Calonico, D., Cantin, E., et al. (2025) · Optica · doi:10.1364/optica.561754 · Cited by 38
Self-citationKoke, S., Kühl, A., Waterholter, T., Raupach, S. M. F., Lopez, O., Cantin, E., Quintin, N., Amy‐Klein, A., Pottie, P.-É., & Grosche, G. (2019) · New Journal of Physics · doi:10.1088/1367-2630/ab5d95 · Cited by 37
“Besides supporting the roadmap towards the redefinition of the SI-second [12], fiber-based comparisons of distant optical clocks enables high-resolution measurements of height differences by chronometric levelling [13][14][15] or tests of non-local relativistic effects [16].”
BackgroundUniversal visible emitters in nanoscale integrated photonics
Spektor, G., Carlson, D. R., Newman, Z. L., Skarda, J., Sapra, N. V., Su, L., Jammi, S., Ferdinand, A. R., Agrawal, A. K., Vučković, J., et al. (2023) · Optica · doi:10.1364/optica.486747 · Cited by 37
Optomechanical resonator-enhanced atom interferometry
Richardson, L., Rajagopalan, A., Albers, H., Meiners, C., Nath, D., Schubert, C., Tell, D., Wodey, É., Abend, S., Gersemann, M., et al. (2020) · Communications Physics · doi:10.1038/s42005-020-00473-4 · Cited by 37
Metadata
- Authors
- Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., Baynes, F. N., Margolis, H. S., Zampaolo, M., Thoumany, P., Pizzocaro, M., Rauf, B., Bregolin, F., Tampellini, A., Barbieri, P., Zucco, M., Costanzo, G. A., Clivati, C., Levi, F., & Calonico, D.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Leibniz University Hannover (DE)
- National Physical Laboratory (GB)
- Istituto Nazionale di Ricerca Metrologica (IT)
- Politecnico di Torino (IT)
- Corresponding author
- Lisdat, Christian
- ORCID
- Venue
- Nature Physics
- Published
- 2018-02-12
- Volume
- 14
- Issue
- 5
- Pages
- 437-441
- ISSN
- 1745-2473 (ISSN-L)
- 1745-2481
- OpenAlex
- W2612253094
- Cited by
- 495
- References
- 63
- Citations by year
- 2026: 37 · 2025: 51 · 2024: 59 · 2023: 62 · 2022: 68 · 2021: 47 · 2020: 78 · 2019: 60 · 2018: 32
- FWCI
- 25.43
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Physics (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion, cc-by-nc-nd)
- PORTO@Iris (submittedVersion, cc-by)
- HAL (submittedVersion, other-oa)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Publication Database GFZ (GFZ German Research Centre for Geosciences) (submittedVersion)
- PORTO Publications Open Repository TOrino (Politecnico di Torino) (submittedVersion, cc-by)
- arXiv (Cornell University)
- Funders
- European Association of National Metrology Institutes (SIB55-ITOC)
- European Commission
- Deutsche Forschungsgemeinschaft (CRC 1128 (“geo-Q”, CRC 1128)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- relativistic geodesy, field measurement campaign, clock comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.