Frequency ratio measurements at 18-digit accuracy using an optical clock network
The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
Atomic clocks are vital in a wide array of technologies and experiments, including tests of fundamental physics 1 . Clocks operating at optical frequencies have now demonstrated fractional stability and reproducibility at the 10 -18 level, two orders of magnitude beyond their microwave predecessors 2 . Frequency ratio measurements between optical clocks are the basis for many of the applications that take advantage of this remarkable precision. However, the highest reported accuracy for frequency ratio measurements has remained largely unchanged for more than a decade 3-5 . Here we operate a network of optical clocks based on 27 Al + (ref. 6 ), 87 Sr (ref. 7 ) and 171 Yb (ref. 8 ), and measure their frequency ratios with fractional uncertainties at or below 8 × 10 -18 . Exploiting this precision, we derive improved constraints on the potential coupling of ultralight bosonic dark matter to standard model fields 9,10 . Our optical clock network utilizes not just optical fibre 11 , but also a 1.5-kilometre free-space link 12,13 . This advance in frequency ratio measurements lays the groundwork for future networks of mobile, airborne and remote optical clocks that will be used to test physical laws 1 , perform relativistic geodesy 14 and substantially improve international timekeeping 15 .
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While this is a small effect, modern optical atomic clocks with their outstanding fractional uncertainty of ∼ 10 -18 [1-4] can resolve a potential difference corresponding to a height difference of ∆ h ∼ 1 cm close to the geoid, where ∆ h = ∆ U/g for a homogeneous gravity acceleration g .”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [3]
In the citing paper
“In the recent past, fractional uncertainty of optical clocks has entered low 10 -18 , which can preliminarily satisfy the needs of centimeter-scale height measurements [12].”
From Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks (2022) · cites this paper as [12]
Citations
Cites
Evaluating the Accuracy of Sampling-Based Approaches to the Calculation of Posterior Moments
Geweke, J. (1992) · Bayesian Statistics 4 · doi:10.1093/oso/9780198522669.003.0010 · Cited by 3,307
Evaluating the Accuracy of Sampling-Based Approaches to the Calculation of Posterior MomentsPreprint
Geweke, J. F. (1991) · doi:10.21034/sr.148 · Cited by 2,521
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationFuller, W. A. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/9780470316665 · Cited by 2,351
Measurement Error in Nonlinear Models
Carroll, R. J., Ruppert, D., Stefanski, L. A., & Crainiceanu, C. M. (2006) · Chapman & Hall/CRC eBooks · doi:10.1201/9781420010138 · Cited by 2,116 · cited 1×
“To test this, we use errors-in-variables regression 63,64 (Extended Data Fig.”
Ultralight scalars as cosmological dark matter
Hui, L., Ostriker, J. P., Tremaine, S., & Witten, E. (2017) · Physical Review D · doi:10.1103/physrevd.95.043541 · Cited by 1,699
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citation20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Self-citationCODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
Research works printed but not linked: 2
- Dörscher, S. et al. Optical frequency ratio of a 171Yb+ single-ion clock and a 87Sr lattice clock. Preprint at https://arXiv.org/abs/2009.05470 (2020). · arXiv
- Gelman, A. et al. Bayesian Data Analysis 3rd edn (Chapman & Hall/CRC Texts in Statistical Science) (CRC Press, 2014).
Cited by
Items 401–427 of 427
Self-Interaction Bounds on Ultralight Dark Matter Couplings to MatterPreprint
Aghaie, M., & Li, S.-P. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2605.03477 · Cited by 2
Oscillating Imprints of Dark Matter in Mesons DecaysPreprint
Chiatto, P. L., Döbrich, B., & Perez, G. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2605.24090
Lunar tidal response-induced clock frequency variations on the Moon
Zhang, H., & Zhang, B. (2026) · The European Physical Journal C · doi:10.1140/epjc/s10052-026-15816-8
Towards dark matter detection by quantum-enhanced spectroscopy
Constantin, F. L. (2026) · SPIE Quantum Technologies · doi:10.1117/12.3099470
A Zeeman slower based on permanent magnets for optical atomic clocks
Bilicki, S., Morzyński, P., Stellmer, S., & Zawada, M. (2026) · Measurement Science and Technology · doi:10.1088/1361-6501/ae7744
Amplifier-free erbium-fiber frequency comb
Wu, T.-H., Newman, Z., MACKENZIE, M., Chang, P., Brooks, N., Chang, K. F., Hickstein, D. D., CARLSON, D. R., & Diddams, S. A. (2026) · Optics Letters · doi:10.1364/ol.597507
Self-citationXujia, 张. Z., Yuyao, 郭. G., Jianping, 陈. C., & Kan, 吴. W. (2026) · Laser & Optoelectronics Progress · doi:10.3788/lop252557
Second-Stage Laser Cooling of Ytterbium Atoms without Using a First-Stage Magneto-Optical Trap
Vyalykh, A. P., Semenko, A. V., Kohanov, A. V., Pal'chikov, V. G., & Belotelov, G. S. (2026) · Journal of Experimental and Theoretical Physics Letters · doi:10.1134/s0021364026601454
A high-flux source of cold strontium with a loading rate of 4×1010 atoms/s for open release
Walker, T., Marchant, A. L., Bentine, E., Buchmueller, O. L., Clarke, K., Foot, C. J., Hawkins, L., Hughes, K. M., Hussain, K., Iannizzotto-Venezze, L., et al. (2026) · AVS Quantum Science · doi:10.1116/5.0338570
Broadband Commercial Frequency Combs for Stability Transfer in Quantum Applications
Smith, C., Cataño-Lopez, S. B., Sodergren, B., Barnes, E., Choura, S., Enlow, E., Spiess, A., Vogel, K. D., Knabe, K., Attar, A., et al. (2026) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_at.2026.jtu.177
Toward high-efficiency repumping for ultra-stable Yb inner-shell optical lattice clocks
Feng, S., Jin, T., Zhang, T., Lei, S., Zhang, J., Xia, Y., Chang, H., Liu, X., Zhang, R., Pan, Y., et al. (2026) · Applied Physics Letters · doi:10.1063/5.0325272
Observation of a sub-Hertz-level Bloch-Siegert shift in a Floquet-engineered optical lattice clock
Anonymous, Lu, X., Chang, H., Zhang, X., & Wang, T. (2026) · Physical Review A · doi:10.1103/mbgj-w2nz
Self-citationLi, W., Wu, T., Pang, Z., Li, C., Song, D., Zhu, H., Sun, P., & Wang, B. (2026) · Laser & Photonics Review · doi:10.1002/lpor.71668
Optical telecommunications-band inner-shell orbital clock transition in neutral erbium atoms
Zhang, S., Duan, Y., Liu, Y., Ma, J., Jie, 王. W., & Wu, H. (2026) · Applied Physics Reviews · doi:10.1063/5.0301129
Spatially defined Rabi spectroscopy for uninterrupted optical clock interrogation
Nishida, K., Takeuchi, R., Tsuji, S., 岡場, 翔., & Katori, H. (2026) · Nature Communications · doi:10.1038/s41467-026-76017-1
Balkie, M. W., Nesic, A., & Schall-Giesecke, A. L. (2026) · Springer proceedings in physics · doi:10.1007/978-3-032-29673-3_7
Absolute frequency measurement of the SrII optical lattice clock at NTSC using TAI for one year
Guo, F., 刘, Y.-Y. 艳. L., Xia, J., Xu, Q. M., Yebing, 王. W., Lu, X., Wu, W.-J., & Chang, H. (2026) · Metrologia · doi:10.1088/1681-7575/ae9772 · Cited by 1
Kletetschka, G. (2026) · Reports in Advances of Physical Sciences · doi:10.1142/s2424942426500106
Yan, 戴. D., Mei, 杨. Y., Yan, M., & Heping, 曾. Z. (2026) · Acta Optica Sinica (Online) · doi:10.3788/aosol260510
Record-breaking optical frequency dissemination over 2,067 km fiber network
Chen, Z., KEmi, X., & Guo, H. (2026) · eLight · doi:10.1186/s43593-026-00137-w
“…precision, optical frequency dissemination supports a wide range of frontier applications, including international optical clock comparisons [1, 2], relativistic geodesy [3], very-long-baseline interferometry [4–6], distributed quantum networks [7], fundamental physics [8–10], and future…”
Enhanced Resolution NEMS-Based Optomechanical Frequency Combs
Mouharrar, H., Ouakad, H. M., Akbari, M., Musselman, K. P., Muñoz‐Rojas, D., Basrour, S., Yavuz, M., & Abdel-Rahman, E. M. (2026) · NODYCON conference proceedings series · doi:10.1007/978-3-032-16532-9_9
Wu, W., Lei, Y., Yu, X., Zhang, J., Song, X., Zhao, J., Chen, Y., Zhang, D., Liang, L., Jia, P., et al. (2026) · Laser & Photonics Review · doi:10.1002/lpor.71773
Local Determination of Comb Mode Number in Remote Optical Clock Comparison
Liu, H., Tian, H., Lu, B., Wang, Q., & Lin, Y. (2026) · Sensors · doi:10.3390/s26175360
“Comparisons of optical clocks with different transitions, or remote comparisons with the same transition, require OFCs whose development has revolutionized optical metrology [13–18].”
Li, 宋. S., Yang, 付. F., Zhai, Y., Hanxu, 吴. W., Shouming, 程. C., Cheng, P., Haonan, 李. L., Xinyi, 陈. C., Zhao, W., Chunlian, 占. Z., et al. (2026) · Acta Optica Sinica · doi:10.3788/aos252116
Dimensional Analysis over Finite Holographic Substrate
Akhtman, Y. (2026) · Entropy · doi:10.3390/e28101122
“That is thirteen orders below the eighteen-digit frequency comparisons of optical clocks [43,44] and twenty-six below the uncertainty of G; in bits, the floor is 102 against the 67 of the finest differential comparison, 7.6 × 10 − 21 within one clock species [45], and no measurement has reached it.”
InfluentialMeasuring space-time with optical lattice clocks
Guzmán, A. M. (2026) · Asian Journal of Physics · doi:10.54955/ajp.35.1-3.2026.123-139
Optical clock network tracks tidal variations of the gravity potentialPreprint
Stahl, K., Nosske, I., Vishwakarma, C., Lücke, T., Klose, J., Benkler, E., Kühl, A., Mukherjee, S., Legero, T., Kronjäger, J., et al. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2610.39635 · Cited by 1
Self-citation
Metadata
- Authors
- Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., Fortier, T. M., Hassan, Y. S., Hume, D. B., Kedar, D., Kennedy, C. J., Khader, I., Koepke, A., Leibrandt, D. R., Leopardi, H., Ludlow, A. D., McGrew, W. F., Milner, W. R., Newbury, N. R., Nicolodi, D., Oelker, E., Parker, T. E., Robinson, J. M., Romisch, S., Schäffer, S. A., Sherman, J. A., Sinclair, L. C., Sonderhouse, L., Swann, W. C., Yao, J., Ye, J., & Zhang, X.
- Affiliations
- National Institute of Standards and Technology (US)
- Joint Institute for Laboratory Astrophysics (US)
- Corresponding author
- Fortier, Tara M.
- Hume, David B.
- Kennedy, Colin J.
- Koepke, Amanda
- Leopardi, Holly
- Sinclair, Laura C.
- Zhang, Xiaogang
- ORCID
- Beloy, Kyle
- Bodine, Martha I.
- Bothwell, Tobias
- Brewer, Samuel M.
- Bromley, Sarah L.
- Chen, Jwo-Sy
- Deschênes, Jean-Daniel
- Diddams, Scott A.
- Fortier, Tara M.
- Hassan, Youssef S.
- Hume, David B.
- Kedar, Dhruv
- Kennedy, Colin J.
- Khader, Isaac
- Leibrandt, David R.
- Leopardi, Holly
- Ludlow, Andrew D.
- McGrew, William F.
- Milner, William R.
- Newbury, Nathan R.
- Nicolodi, Daniele
- Oelker, Eric
- Parker, Thomas E.
- Robinson, John M.
- Romisch, Stefania
- Schäffer, Stefan A.
- Sinclair, Laura C.
- Sonderhouse, Lindsay
- Yao, Jian
- Ye, Jun
- Zhang, Xiaogang
- Venue
- Nature
- Published
- 2021-03-24
- Volume
- 591
- Issue
- 7851
- Pages
- 564-569
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W4230217355
- Cited by
- 390
- References
- 66
- Citations by year
- 2026: 47 · 2025: 88 · 2024: 87 · 2023: 83 · 2022: 60 · 2021: 25
- FWCI
- 28.05
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Keywords
- optical atomic clocks, frequency ratio measurement, clock distribution, 27Al, 87Sr, 171Yb, free-space optical links, ultralight bosonic dark matter, fundamental physics tests, relativistic geodesy, timekeeping
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.