Frequency ratio measurements at 18-digit accuracy using an optical clock network
The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
Atomic clocks are vital in a wide array of technologies and experiments, including tests of fundamental physics 1 . Clocks operating at optical frequencies have now demonstrated fractional stability and reproducibility at the 10 -18 level, two orders of magnitude beyond their microwave predecessors 2 . Frequency ratio measurements between optical clocks are the basis for many of the applications that take advantage of this remarkable precision. However, the highest reported accuracy for frequency ratio measurements has remained largely unchanged for more than a decade 3-5 . Here we operate a network of optical clocks based on 27 Al + (ref. 6 ), 87 Sr (ref. 7 ) and 171 Yb (ref. 8 ), and measure their frequency ratios with fractional uncertainties at or below 8 × 10 -18 . Exploiting this precision, we derive improved constraints on the potential coupling of ultralight bosonic dark matter to standard model fields 9,10 . Our optical clock network utilizes not just optical fibre 11 , but also a 1.5-kilometre free-space link 12,13 . This advance in frequency ratio measurements lays the groundwork for future networks of mobile, airborne and remote optical clocks that will be used to test physical laws 1 , perform relativistic geodesy 14 and substantially improve international timekeeping 15 .
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While this is a small effect, modern optical atomic clocks with their outstanding fractional uncertainty of ∼ 10 -18 [1-4] can resolve a potential difference corresponding to a height difference of ∆ h ∼ 1 cm close to the geoid, where ∆ h = ∆ U/g for a homogeneous gravity acceleration g .”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [3]
In the citing paper
“In the recent past, fractional uncertainty of optical clocks has entered low 10 -18 , which can preliminarily satisfy the needs of centimeter-scale height measurements [12].”
From Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks (2022) · cites this paper as [12]
Citations
Cites
Evaluating the Accuracy of Sampling-Based Approaches to the Calculation of Posterior Moments
Geweke, J. (1992) · Bayesian Statistics 4 · doi:10.1093/oso/9780198522669.003.0010 · Cited by 3,307
Evaluating the Accuracy of Sampling-Based Approaches to the Calculation of Posterior MomentsPreprint
Geweke, J. F. (1991) · doi:10.21034/sr.148 · Cited by 2,521
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationFuller, W. A. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/9780470316665 · Cited by 2,351
Measurement Error in Nonlinear Models
Carroll, R. J., Ruppert, D., Stefanski, L. A., & Crainiceanu, C. M. (2006) · Chapman & Hall/CRC eBooks · doi:10.1201/9781420010138 · Cited by 2,116 · cited 1×
“To test this, we use errors-in-variables regression 63,64 (Extended Data Fig.”
Ultralight scalars as cosmological dark matter
Hui, L., Ostriker, J. P., Tremaine, S., & Witten, E. (2017) · Physical Review D · doi:10.1103/physrevd.95.043541 · Cited by 1,699
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citation20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Self-citationCODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Self-citationChou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
Self-citationSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 1×
“This work employed the JILA SrI clock system instead of the SrII sys-tem 16 .”
Self-citationAtomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
Self-citation(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Self-citationSingle-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Ma, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566
Self-citationTest of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citationGodun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
A clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
Self-citationJILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324
Self-citationMonoion oscillator as potential ultimate laser frequency standard
Dehmelt, H. G. (1982) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1982.6312526 · Cited by 323
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Optical clock comparison for Lorentz symmetry testing
Sanner, C., Huntemann, N., Lange, R., Tamm, C., Peik, E., Safronova, M. S., & Porsev, S. G. (2019) · Nature · doi:10.1038/s41586-019-0972-2 · Cited by 275
Lemke, N., Ludlow, A., Barber, Z., Fortier, T., Diddams, S., Jiang, Y., Jefferts, S., Heavner, T., Parker, T., & Oates, C. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.063001 · Cited by 274
Self-citationRiehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Search for Ultralight Scalar Dark Matter with Atomic Spectroscopy
Van Tilburg, K., Leefer, N., Bougas, L., & Budker, D. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.011802 · Cited by 253
Hees, A., Guéna, J., Abgrall, M., Bize, S., & Wolf, P. (2016) · Physical Review Letters · doi:10.1103/physrevlett.117.061301 · Cited by 230
Stochastic fluctuations of bosonic dark matter
Centers, G. P., Blanchard, J. W., Conrad, J., Figueroa, N. L., Garcon, A., Gramolin, A. V., Kimball, D. F. J., Lawson, M., Pelssers, B., Smiga, J. A., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-27632-7 · Cited by 229 · cited 3×
“All bounds derived from atomic spectroscopy are modified by the same scaling factor to account for stochastic fluctuations in the dark-matter field amplitude 53 .”
InfluentialCoherent transfer of an optical carrier over 251 km
Newbury, N. R., Williams, P. A., & Swann, W. C. (2007) · Optics Letters · doi:10.1364/ol.32.003056 · Cited by 228
Self-citationFrequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
Kennedy, C. J., Oelker, E., Robinson, J. M., Bothwell, T., Kedar, D., Milner, W. R., Marti, G. E., Derevianko, A., & Ye, J. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.201302 · Cited by 219
Self-citationFortier, T. M., Bartels, A., & Diddams, S. A. (2006) · Optics Letters · doi:10.1364/ol.31.001011 · Cited by 212
Self-citationImproved Limits for Violations of Local Position Invariance from Atomic Clock Comparisons
Lange, R., Huntemann, N., Rahm, J. M., Sanner, C., Shao, H., Lipphardt, B., Tamm, C., Weyers, S., & Peik, E. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.011102 · Cited by 200
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
Synchronization of Distant Optical Clocks at the Femtosecond Level
Deschênes, J.-D., Sinclair, L. C., Giorgetta, F. R., Swann, W. C., Baumann, E., Bergeron, H., Cermak, M., Coddington, I., & Newbury, N. R. (2016) · Physical Review X · doi:10.1103/physrevx.6.021016 · Cited by 164 · cited 1×
“Because the sampled air paths are common to pulse trains travelling in each direction, O-TWTFT allows for frequency transfer at better than 10 −18 instability despite the presence of kilometre-length turbulent air paths 12,36 .”
Self-citationNew bounds on dark matter coupling from a global network of optical atomic clocks
Wcisło, P., Ablewski, P., Beloy, K., Bilicki, S., Bober, M., Brown, R., Fasano, R., Ciuryło, R., Hachisu, H., Ido, T., et al. (2018) · Science Advances · doi:10.1126/sciadv.aau4869 · Cited by 159
Self-citationThe absolute frequency of the87Sr optical clock transition
Campbell, G. K., Ludlow, A. D., Blatt, S., Thomsen, J. W., Martin, M. J., de Miranda, M. H. G., Zelevinsky, T., Boyd, M. M., Ye, J., Diddams, S. A., et al. (2008) · Metrologia · doi:10.1088/0026-1394/45/5/008 · Cited by 151
Self-citationRealization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Coherent Optical Phase Transfer over a 32-km Fiber with 1 s Instability at10−17
Foreman, S. M., Ludlow, A. D., de Miranda, M. H. G., Stalnaker, J. E., Diddams, S. A., & Ye, J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.153601 · Cited by 141
Self-citationTowards the optical second: verifying optical clocks at the SI limit
McGrew, W. F., Zhang, X., Leopardi, H., Fasano, R. J., Nicolodi, D., Beloy, K., Yao, J., Sherman, J. A., Schäffer, S. A., Savory, J., et al. (2019) · Optica · doi:10.1364/optica.6.000448 · Cited by 135
Self-citationProspects for using laser-prepared atomic fountains for optical frequency standards applications
Hall, J. L., Zhu, M., & Buch, P. (1989) · Journal of the Optical Society of America B · doi:10.1364/josab.6.002194 · Cited by 130
Consensus building for interlaboratory studies, key comparisons, and meta-analysis
Koepke, A., Lafarge, T., Possolo, A. M., & Toman, B. (2017) · Metrologia · doi:10.1088/1681-7575/aa6c0e · Cited by 107
Self-citationLeopardi, H., Davila-Rodriguez, J., Quinlan, F., Olson, J., Sherman, J. A., Diddams, S. A., & Fortier, T. M. (2017) · Optica · doi:10.1364/optica.4.000879 · Cited by 104
Self-citationOptical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
Self-citationWhen should we change the definition of the second?
Gill, P. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0237 · Cited by 101
Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock
Brown, R. C., Phillips, N. B., Beloy, K., McGrew, W. F., Schioppo, M., Fasano, R. J., Milani, G., Zhang, X., Hinkley, N., Leopardi, H., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.253001 · Cited by 101
Self-citationFrequency ratios of Sr, Yb, and Hg based optical lattice clocks and their applications
Takamoto, M., Ushijima, I., Das, M., Nemitz, N., Ohkubo, T., Yamanaka, K., Ohmae, N., Takano, T., Akatsuka, T., Yamaguchi, A., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.04.003 · Cited by 85
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Tyumenev, R., Favier, M., Bilicki, S., Bookjans, E., Targat, R. L., Lodewyck, J., Nicolodi, D., Coq, Y. L., Abgrall, M., Guéna, J., et al. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/11/113002 · Cited by 85
Self-citationStrategies for reducing the light shift in atomic clocks
Katori, H., Ovsiannikov, V. D., Marmo, S. I., & Palchikov, V. G. (2015) · Physical Review A · doi:10.1103/physreva.91.052503 · Cited by 74
Comparing Optical Oscillators across the Air to Milliradians in Phase and 10−17 in Frequency
Sinclair, L. C., Bergeron, H., Swann, W. C., Baumann, E., Deschênes, J.-D., & Newbury, N. R. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.050801 · Cited by 74
Self-citationOptical-to-microwave frequency comparison with fractional uncertainty of 10-15
Stalnaker, J. E., Diddams, S. A., Fortier, T. M., Kim, K., Hollberg, L. W., Bergquist, J., Itano, W. M., Delany, M. J., Lorini, L., Oskay, W. H., et al. (2007) · Applied Physics B · doi:10.1007/s00340-007-2762-z · Cited by 59
Self-citationPizzocaro, M., Thoumany, P., Rauf, B., Bregolin, F., Milani, G., Clivati, C., Costanzo, G. A., Levi, F., & Calonico, D. (2017) · Metrologia · doi:10.1088/1681-7575/aa4e62 · Cited by 58
Hachisu, H., Petit, G., Nakagawa, F., Hanado, Y., & Ido, T. (2017) · Optics Express · doi:10.1364/oe.25.008511 · Cited by 53
Optical frequency ratio of a 171Yb+ single-ion clock and a 87Sr lattice clock
Dörscher, S., Huntemann, N., Schwarz, R., Lange, R., Benkler, E., Lipphardt, B., Sterr, U., Peik, E., & Lisdat, C. (2021) · Metrologia · doi:10.1088/1681-7575/abc86f · Cited by 53
Frequency ratio measurement of ^171Yb and ^87Sr optical lattice clocks
Akamatsu, D., Yasuda, M., Inaba, H., Hosaka, K., Tanabe, T., Onae, A., & Hong, F.-L. (2014) · Optics Express · doi:10.1364/oe.22.007898 · Cited by 48
Single-ion, transportable optical atomic clocks
Delehaye, M., & Lacroûte, C. (2018) · Journal of Modern Optics · doi:10.1080/09500340.2018.1441917 · Cited by 40
Kim, H., Heo, M.-S., Lee, W.-K., Park, C. Y., Hong, H.-G., Hwang, S.-W., & Yu, D.-H. (2017) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.050302 · Cited by 38
Ohmae, N., Bregolin, F., Nemitz, N., & Katori, H. (2020) · Optics Express · doi:10.1364/oe.391602 · Cited by 36
Modeling light shifts in optical lattice clocks
Nemitz, N., Jørgensen, A. A., Yanagimoto, R., Bregolin, F., & Katori, H. (2019) · Physical Review A · doi:10.1103/physreva.99.033424 · Cited by 34
Optical atomic clock comparison through turbulent air
Bodine, M. I., Deschênes, J.-D., Khader, I. H., Swann, W. C., Leopardi, H., Beloy, K., Bothwell, T., Brewer, S. M., Bromley, S., Chen, J.-S., et al. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033395 · Cited by 31
Self-citationALPHA-DOT OR NOT: COMPARISON OF TWO SINGLE ATOM OPTICAL CLOCKS
Rosenband, T., Hume, D. B., Chou, C. W., Koelemeij, J. C. J., Brusch, A., Bickman, S., Oskay, W. H., Fortier, T. M., Stalnaker, J. E., Diddams, S. A., et al. (2009) · Symposium on Frequency Standards and Metrology · doi:10.1142/9789812838223_0002 · Cited by 3 · cited 1×
“Here we evaluate all ratio data between optical clocks at NIST/JILA, including the earlier comparison of the Al + and Hg + clocks 3,41 , to establish new constraints on the modulus, d e , describing the coupling of dark matter to the electromagnetic tensor (Fig.”
Self-citation
Research works printed but not linked: 2
- Dörscher, S. et al. Optical frequency ratio of a 171Yb+ single-ion clock and a 87Sr lattice clock. Preprint at https://arXiv.org/abs/2009.05470 (2020). · arXiv
- Gelman, A. et al. Bayesian Data Analysis 3rd edn (Chapman & Hall/CRC Texts in Statistical Science) (CRC Press, 2014).
Cited by
The NANOGrav 15 yr Data Set: Search for Signals from New Physics
Afzal, A., Agazie, G., Anumarlapudi, A., Archibald, A. M., Arzoumanian, Z., Baker, P. T., Bécsy, B., Blanco-Pillado, J. J., Blecha, L., Boddy, K. K., et al. (2023) · The Astrophysical Journal Letters · doi:10.3847/2041-8213/acdc91 · Cited by 750
Integrated optical frequency comb technologies
Chang, L., Liu, S., & Bowers, J. E. (2022) · Nature Photonics · doi:10.1038/s41566-021-00945-1 · Cited by 659
Resolving the gravitational redshift across a millimetre-scale atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2022) · Nature · doi:10.1038/s41586-021-04349-7 · Cited by 449
Self-citationClock with 8 × 10 − 19 Systematic Uncertainty
Aeppli, A., Kim, K., Warfield, W., Safronova, M. S., & Ye, J. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.023401 · Cited by 211
“Every gain in stability and accuracy opens new realms of exploration, such as placing bounds on dark matter [8, 9], probing general relativity [10, 11], and will ultimately result in the redefinition of the SI second [12–14].”
BackgroundSelf-citationStochastic fluctuations of bosonic dark matter
Centers, G. P., Blanchard, J. W., Conrad, J., Figueroa, N. L., Garcon, A., Gramolin, A. V., Kimball, D. F. J., Lawson, M., Pelssers, B., Smiga, J. A., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-27632-7 · Cited by 229
Metadata
- Authors
- Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., Fortier, T. M., Hassan, Y. S., Hume, D. B., Kedar, D., Kennedy, C. J., Khader, I., Koepke, A., Leibrandt, D. R., Leopardi, H., Ludlow, A. D., McGrew, W. F., Milner, W. R., Newbury, N. R., Nicolodi, D., Oelker, E., Parker, T. E., Robinson, J. M., Romisch, S., Schäffer, S. A., Sherman, J. A., Sinclair, L. C., Sonderhouse, L., Swann, W. C., Yao, J., Ye, J., & Zhang, X.
- Affiliations
- National Institute of Standards and Technology (US)
- Joint Institute for Laboratory Astrophysics (US)
- Corresponding author
- Fortier, Tara M.
- Hume, David B.
- Kennedy, Colin J.
- Koepke, Amanda
- Leopardi, Holly
- Sinclair, Laura C.
- Zhang, Xiaogang
- ORCID
- Beloy, Kyle
- Bodine, Martha I.
- Bothwell, Tobias
- Brewer, Samuel M.
- Bromley, Sarah L.
- Chen, Jwo-Sy
- Deschênes, Jean-Daniel
- Diddams, Scott A.
- Fortier, Tara M.
- Hassan, Youssef S.
- Hume, David B.
- Kedar, Dhruv
- Kennedy, Colin J.
- Khader, Isaac
- Leibrandt, David R.
- Leopardi, Holly
- Ludlow, Andrew D.
- McGrew, William F.
- Milner, William R.
- Newbury, Nathan R.
- Nicolodi, Daniele
- Oelker, Eric
- Parker, Thomas E.
- Robinson, John M.
- Romisch, Stefania
- Schäffer, Stefan A.
- Sinclair, Laura C.
- Sonderhouse, Lindsay
- Yao, Jian
- Ye, Jun
- Zhang, Xiaogang
- Venue
- Nature
- Published
- 2021-03-24
- Volume
- 591
- Issue
- 7851
- Pages
- 564-569
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W4230217355
- Cited by
- 390
- References
- 66
- Citations by year
- 2026: 47 · 2025: 88 · 2024: 87 · 2023: 83 · 2022: 60 · 2021: 25
- FWCI
- 28.05
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Keywords
- optical atomic clocks, frequency ratio measurement, clock distribution, 27Al, 87Sr, 171Yb, free-space optical links, ultralight bosonic dark matter, fundamental physics tests, relativistic geodesy, timekeeping
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.