Plug-and-play control of a brain–computer interface through neural map stabilization
The DOI matches its Crossref record; 73 of the 74 references it cites were found in a registry or an index.
Abstract
Brain-computer interfaces (BCIs) enable control of assistive devices in individuals with severe motor impairments. A limitation of BCIs that has hindered real-world adoption is poor long-term reliability and lengthy daily recalibration times. To develop methods that allow stable performance without recalibration, we used a 128-channel chronic electrocorticography (ECoG) implant in a paralyzed individual, which allowed stable monitoring of signals. We show that long-term closed-loop decoder adaptation, in which decoder weights are carried across sessions over multiple days, results in consolidation of a neural map and 'plug-and-play' control. In contrast, daily reinitialization led to degradation of performance with variable relearning. Consolidation also allowed the addition of control features over days, that is, long-term stacking of dimensions. Our results offer an approach for reliable, stable BCI control by leveraging the stability of ECoG interfaces and neural plasticity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Despite this, durable stability has enabled ECoG-based neuroprostheses without the need for daily calibration by the user12,14,94,95.”
From The speech neuroprosthesis (2024) · cites this paper as [94]
Citations
Cites
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Neuroplasticity Subserving Motor Skill Learning
Dayan, E., & Cohen, L. G. (2011) · Neuron · doi:10.1016/j.neuron.2011.10.008 · Cited by 1,408
Cited by
Neuroprosthesis for Decoding Speech in a Paralyzed Person with Anarthria
Moses, D. A., Metzger, S. L., Liu, J. R., Anumanchipalli, G. K., Makin, J. G., Sun, P. F., Chartier, J., Dougherty, M. E., Liu, P. M., Abrams, G. M., et al. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2027540 · Cited by 582
“In previously reported brain–computer interface applications, decoding models often require daily recalibration before deployment with a user,(6,35) which can increase the variability of decoder performance across days and impede longterm adoption of the interface for real-world use.(35,36) Because of the relatively h…”
BackgroundSelf-citationBrain–computer interface: trend, challenges, and threats
Maiseli, B., Abdalla, A. T., Massawe, L. V., Mbise, M., Mkocha, K., Nassor, N. A., Ismail, M., Michael, J., & Kimambo, S. (2023) · Brain Informatics · doi:10.1186/s40708-023-00199-3 · Cited by 168
Simeral, J. D., Hosman, T., Saab, J., Flesher, S. N., Vilela, M., Franco, B., Kelemen, J. N., Brandman, D. M., Ciancibello, J. G., Rezaii, P. G., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069119 · Cited by 165
“8 on a 4x4 grid task [53].”
Metzger, S. L., Liu, J. R., Moses, D. A., Dougherty, M. E., Seaton, M. P., Littlejohn, K. T., Chartier, J., Anumanchipalli, G. K., Tu-Chan, A., Ganguly, K., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-33611-3 · Cited by 153
Self-citationFlexible Electrodes for Brain–Computer Interface System
Wang, J., Wang, T., Liu, H., Wang, K., Kumi, M., Feng, Z., Li, P., & Huang, W. (2023) · Advanced Materials · doi:10.1002/adma.202211012 · Cited by 158
The state of clinical trials of implantable brain–computer interfaces
Patrick-Krueger, K. M., Burkhart, I., & Contreras-Vidal, J. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00239-5 · Cited by 125
Shin, J. H., Kwon, J., Kim, J. U., Ryu, H., Ok, J., Joon Kwon, S., Park, H., & Kim, T.-I. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00164-w · Cited by 123
“…which enables interaction between the brain and machines 14 – 16 , can be established using electrophysiological sensors, such as brain-surface 17 , brain-penetrating 18,19 , and skin-surface electrodes 20,21 , to assess electrocorticography (ECoG), local fi eld potentials (LFPs), and…”
BackgroundBrain-Computer Interface: Applications to Speech Decoding and Synthesis to Augment Communication
Luo, S., Rabbani, Q., & Crone, N. E. (2022) · Neurotherapeutics · doi:10.1007/s13311-022-01190-2 · Cited by 106
“However, motor BCI research based on long-term ECoG signals have demonstrated reliable decoding from chronic implants [81, 82].”
BackgroundSilva, A. B., Littlejohn, K. T., Liu, J. R., Moses, D. A., & Chang, E. F. (2024) · Nature Reviews Neuroscience · doi:10.1038/s41583-024-00819-9 · Cited by 103
“Despite this, durable stability has enabled ECoG-based neuroprostheses without the need for daily calibration by the user 12,14,94,95 .”
Self-citationA memristor-based adaptive neuromorphic decoder for brain–computer interfaces
Liu, Z., Mei, J., Tang, J., Xu, M., Gao, B., Wang, K., Ding, S., Liu, Q., Qin, Q., Chen, W., et al. (2025) · Nature Electronics · doi:10.1038/s41928-025-01340-2 · Cited by 138
“Towards practical applications, previous studies suggest that a BCI would achieve optimal performance when both the brain and the decoder can adapt to new scenarios 7,50,51 .”
Angrick, M., Luo, S., Rabbani, Q., Candrea, D. N., Shah, S., Milsap, G. W., Anderson, W. S., Gordon, C. R., Rosenblatt, K. R., Clawson, L., et al. (2023) · doi:10.1101/2023.06.30.23291352 · Cited by 95
Angrick, M., Luo, S., Rabbani, Q., Candrea, D. N., Shah, S., Milsap, G., Anderson, W. S., Gordon, C. R., Rosenblatt, K. R., Clawson, L., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-60277-2 · Cited by 120
Luo, S., Angrick, M., Coogan, C., Candrea, D. N., Wyse‐Sookoo, K., Shah, S., Rabbani, Q., Milsap, G. W., Weiss, A. R., Anderson, W. S., et al. (2023) · Advanced Science · doi:10.1002/advs.202304853 · Cited by 90
A survey on hybrid human-artificial intelligence for autonomous driving
Ning, H., Yin, R., Ullah, A., & Shi, F. (2022) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2021.3074695 · Cited by 84
“At present, BCI research mainly involves improving accuracy, reducing delay and cost, and designing for generalization [104], [106], [107].”
BackgroundMethodThe science and engineering behind sensitized brain-controlled bionic hands
Pandarinath, C., & Bensmaïa, S. J. (2021) · Physiological Reviews · doi:10.1152/physrev.00034.2020 · Cited by 91
“2021 [245] ECoG Point-and click (grid) B1 Brainstem stroke 0.”
BackgroundStabilizing brain-computer interfaces through alignment of latent dynamics
Karpowicz, B. M., Ali, Y. H., Wimalasena, L. N., Sedler, A. R., Keshtkaran, M. R., Bodkin, K., Ma, X., Miller, L. E., & Pandarinath, C. (2022) · doi:10.1101/2022.04.06.487388 · Cited by 71
Stabilizing brain-computer interfaces through alignment of latent dynamics
Karpowicz, B. M., Ali, Y. H., Wimalasena, L. N., Sedler, A. R., Keshtkaran, M. R., Bodkin, K. L., Ma, X., Rubin, D. B., Williams, Z. M., Cash, S. S., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-59652-y · Cited by 115
Khan, A. A., Laghari, A. A., Shaikh, A. A., Dootio, M. A., Estrela, V. V., & Lopes, R. T. (2021) · Neuroscience Informatics · doi:10.1016/j.neuri.2021.100030 · Cited by 78
Decoding motor plans using a closed-loop ultrasonic brain–machine interface
Griggs, W. S., Norman, S. L., Deffieux, T., Segura, F., Osmanski, B.-F., Chau, G., Christopoulos, V., Liu, C. Y., Tanter, M., Shapiro, M. G., et al. (2023) · Nature Neuroscience · doi:10.1038/s41593-023-01500-7 · Cited by 91
“This is similar to the advantage seen with ECoG based BMIs, which can work well across sessions with minimal, if any, recalibration 41–43 .”
MethodVansteensel, M. J., Klein, E., van Thiel, G., Gaytant, M., Simmons, Z., Wolpaw, J. R., & Vaughan, T. M. (2023) · Journal of Neurology · doi:10.1007/s00415-022-11464-6 · Cited by 59
Learning to control a BMI-driven wheelchair for people with severe tetraplegia
Tonin, L., Perdikis, S., Kuzu, T. D., Pardo, J., Orset, B., Lee, K., Aach, M., Schildhauer, T. A., Martínez, R., & Millán, J. D. R. (2022) · iScience · doi:10.1016/j.isci.2022.105418 · Cited by 68
“BMI translational studies remain surprisingly limited (Birbaumer et al., 1999; Pfurtscheller et al., 2003; Wolpaw and McFarland, 2004; Kübler et al., 2005; Leeb et al., 2007, Leeb et al., 2013, 2015; McFarland et al., 2010; Kim et al., 2011; Gilja et al., 2012, 2015; Hochberg et al., 2012; Collinger et al., 2013; Wang…”
BackgroundBergeron, D., Iorio‐Morin, C., Bonizzato, M., Lajoie, G., Gaucher, N. O., Racine, É., & Weil, A. G. (2023) · Journal of Child Neurology · doi:10.1177/08830738231167736 · Cited by 61
Transfer learning promotes acquisition of individual BCI skills
Kumar, S., Alawieh, H., Rácz, F. S., Fakhreddine, R., & Millán, J. D. R. (2024) · PNAS Nexus · doi:10.1093/pnasnexus/pgae076 · Cited by 63
Multi-scale neural decoding and analysis
Lu, H., Lorenc, E. S., Zhu, H., Kilmarx, J., Sulzer, J. S., Xie, C., Tobler, P. N., Watrous, A. J., Orsborn, A. L., Lewis‐Peacock, J. A., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac160f · Cited by 55
“Several recent papers have demonstrated reliable real-time motor BMI control with ECoG [28, 29].”
BackgroundLuo, T.-J. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104397 · Cited by 47
Silva, A. B., Liu, J. R., Metzger, S. L., Bhaya-Grossman, I., Dougherty, M. E., Seaton, M. P., Littlejohn, K. T., Tu-Chan, A., Ganguly, K., Moses, D. A., et al. (2024) · Nature Biomedical Engineering · doi:10.1038/s41551-024-01207-5 · Cited by 67
Self-citationNatraj, N., Seko, S., Abiri, R., Miao, R., Yan, H., Graham, Y., Tu-Chan, A., Chang, E. F., & Ganguly, K. (2025) · Cell · doi:10.1016/j.cell.2025.02.001 · Cited by 48
Self-citationReinvigorating electrochemistry education
Kempler, P. A., Boettcher, S. W., & Ardo, S. (2021) · iScience · doi:10.1016/j.isci.2021.102481 · Cited by 48
Cortico-cerebellar coordination facilitates neuroprosthetic control
Abbasi, A., Rangwani, R., Bowen, D., Fealy, A. W., Danielsen, N. P., & Gulati, T. (2024) · Science Advances · doi:10.1126/sciadv.adm8246 · Cited by 46
“BMI studies that allow for sleep consolidation ( 11 , 12 , 18 ) or use multiple days of learning ( 15 , 70 ) find that M1 TR i units weaken their modulation through the course of extensive training.”
Natraj, N., Silversmith, D. B., Chang, E. F., & Ganguly, K. (2021) · Neuron · doi:10.1016/j.neuron.2021.10.002 · Cited by 54
“These results have applications with respect to ECoG in human brain machine interface (BCIs) trials (Silversmith et al., 2021; Benabid et al., 2019).”
BackgroundSelf-citationDecoding ECoG signal into 3D hand translation using deep learning
Śliwowski, M., Martin, M., Souloumiac, A., Blanchart, P., & Aksenova, T. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5d69 · Cited by 47
“LSTMs were used to classify fingers activation [19, 62] and three different hand gestures [63] from time-frequency features.”
Long-term stability of the chronic epidural wireless recorder WIMAGINE in tetraplegic patients
Larzabal, C., Bonnet, S., Costecalde, T., Auboiroux, V., Charvet, G., Chabardes, S., Aksenova, T., & Sauter-Starace, F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2003 · Cited by 37
“ECoG recordings have shown promising potential in terms of signal longevity [27, 28].”
Graphene and graphene-related materials as brain electrodes
Xu, B., Pei, J., Feng, L., & Zhang, X. (2021) · Journal of Materials Chemistry B · doi:10.1039/d1tb01795k · Cited by 40
Neural Plasticity in Sensorimotor Brain–Machine Interfaces
Dadarlat, M. C., Canfield, R. A., & Orsborn, A. L. (2023) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-110833 · Cited by 38
“Long-term ECoG BMI use leads to high performance and user learning (61, 73); population feature BMI studies have reported primarily maintenance of performance (75).”
BackgroundMethodInfluentialRecent Progress in Long-Term Sleep Monitoring Technology
Yin, J., Xu, J., & Ren, T. (2023) · Biosensors · doi:10.3390/bios13030395 · Cited by 40
“Although its main application area is to assist people with motor impairments to control assistive devices [80,81], sensors on EEG signals may further advance the development of sleep monitoring technology in the future.”
BackgroundCognitive Computing for Brain–Computer Interface-Based Computational Social Digital Twins Systems
Lv, Z., Qiao, L., & Lv, H. (2022) · IEEE Transactions on Computational Social Systems · doi:10.1109/tcss.2022.3202872 · Cited by 32
“Researchers need to master programming ability and understand biomedical, data processing, and pattern recognition knowledge, which is a comprehensive research field [9], [10].”
BackgroundNine decades of electrocorticography: A comparison between epidural and subdural recordings
Branco, M. P., Geukes, S. H., Aarnoutse, E. J., Ramsey, N. F., & Vansteensel, M. J. (2023) · European Journal of Neuroscience · doi:10.1111/ejn.15941 · Cited by 44
“%) with those reported in subdural studies that used similar strategies (Bashford et al., 2018; Degenhart et al., 2018; Silversmith et al., 2021), such as a recent study that demonstrated >85% accuracy in real-time click control using subdural ECoG (Silversmith et al., 2021).”
BackgroundResultInfluentialRestoring Speech Using Brain–Computer Interfaces
Stavisky, S. D. (2025) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110122-012818 · Cited by 52
Neural Data Transformer 2: Multi-context Pretraining for Neural Spiking Activity
Ye, J., Collinger, J. L., Wehbe, L., & Gaunt, R. (2023) · neural information processing systems · doi:10.52202/075280-3523 · Cited by 131
Davis, K., Meschede-Krasa, B., Cajigas, I., Prins, N. W., Alver, C. G., Gallo, S., Bhatia, S., Abel, J. H., Naeem, J., Fisher, L., et al. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01026-2 · Cited by 36
A Framework for Optimizing Co-adaptation in Body-Machine Interfaces
Santis, D. D. (2021) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2021.662181 · Cited by 35
“…been developed to address the issue of decoder instability (Vidaurre et al., 2011; Kao et al., 2017; Yeung et al., 2019; Degenhart et al., 2020; Silversmith et al., 2020) and to compensate for performance degradation due to the emergent closed-loop dynamics during use (Orsborn et al., 2012;…”
BackgroundRecent advances in wireless epicortical and intracortical neuronal recording systems
Ji, B., Liang, Z., Yuan, X., Xu, H., Wang, M., Yin, E., Guo, Z., Wang, L., Zhou, Y., Feng, H., et al. (2022) · Science China Information Sciences · doi:10.1007/s11432-021-3373-1 · Cited by 32
Leogrande, E., Filosa, M., Ballanti, S., Cicco, L. D., Mazzoleni, S., Ackerley, R., Oddo, C. M., & Dell’Olio, F. (2025) · Sensors and Actuators Reports · doi:10.1016/j.snr.2025.100312 · Cited by 32
How Far for the Electronic Skin: From Multifunctional Material to Advanced Applications
Chen, Y., Sun, Y., Wei, Y., & Qiu, J. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201352 · Cited by 26
Müller-Putz, G., Kobler, R. J., Pereira, J., Lopes-Dias, C., Hehenberger, L., Mondini, V., Martínez-Cagigal, V., Srisrisawang, N., Pulferer, H. S., Batistić, L., et al. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.841312 · Cited by 28
“While electrocorticogram (ECoG) is less invasive than MEAs, the first results for motor control applied in tetraplegics were recently reported (Silversmith et al., 2020).”
BackgroundEEG error-related potentials encode magnitude of errors and individual perceptual thresholds
Iwane, F., Sobolewski, A., Chavarriaga, R., & Millán, J. D. R. (2023) · iScience · doi:10.1016/j.isci.2023.107524 · Cited by 29
Candrea, D. N., Shah, S., Luo, S., Angrick, M., Rabbani, Q., Coogan, C. G., Milsap, G., Nathan, K., Wester, B. A., Anderson, W. S., et al. (2024) · Communications Medicine · doi:10.1038/s43856-024-00635-3 · Cited by 32
Ji, B., Sun, F., Guo, J., Zhou, Y., You, X., Ye, F., Wang, L., Xu, M., Zeng, W., Liu, J., et al. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00597-x · Cited by 29
“Currently, most commercially available ECoG cortical electrodes are the macro-electrodes composed of silicone and platinum-iridium alloy 26,27 , such as conventional ECoG devices from Cortec GmbH, g.tec medical engineering GmbH, PMT Corporation, Ad-Tech Medical Instrument Corporation, etc.”
BackgroundMondini, V., Sburlea, A. I., & Müller-Putz, G. (2024) · Scientific Reports · doi:10.1038/s41598-024-55413-x · Cited by 28
Wyse‐Sookoo, K., Luo, S., Candrea, D. N., Schippers, A., Tippett, D. C., Wester, B. A., Fifer, M. S., Vansteensel, M. J., Ramsey, N. F., & Crone, N. E. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad5c02 · Cited by 27
“The work of Silversmith et al in plug-and-play cursor control, and Benabid et al in long-term exoskel-eton control demonstrate the ability of upper limb ECoG BCIs to function over many days without the need for retraining [18, 22, 23].”
Brain–computer interface control with artificial intelligence copilots
Lee, J. Y., Lee, S., Mishra, A., Xu, Y., McMahan, B., Gaisford, B., Kobashigawa, C., Qu, M., Xie, C., & Kao, J. C. (2025) · Nature Machine Intelligence · doi:10.1038/s42256-025-01090-y · Cited by 65
“These approaches are complementary to other techniques to reduce the dial-in time 3,18,21,34–36 that could be combined with AI copilots.”
InfluentialBiosignal-based co-adaptive user-machine interfaces for motor control
Madduri, M. M., Burden, S. A., & Orsborn, A. L. (2023) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2023.100462 · Cited by 32
“The Silversmith et al., 2020 study highlights translation of many of these observations to human subjects.”
BackgroundWu, X., Metcalfe, B., He, S., Tan, H., & Zhang, D. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3421551 · Cited by 27
“Though the sampling rate of modern recording devices can be as high as 30k Hz [134], most invasive studies extracted features from multiple frequency bands below 500 Hz.”
BackgroundDohle, E., Swanson, E., Jovanović, L., Yusuf, S., Thompson, L., Horsfall, H. L., Muirhead, W. R., Bashford, L., & Brannigan, J. (2025) · Advanced Science · doi:10.1002/advs.202501912 · Cited by 31
A Comprehensive Survey of Brain–Computer Interface Technology in Health care: Research Perspectives
Cruz, M. V., Jamal, S., & Sethuraman, S. C. (2025) · Journal of Medical Signals & Sensors · doi:10.4103/jmss.jmss_49_24 · Cited by 27
“115-117] Devices such as neurostimulation (RNS) can be integrated to deliver targeted electrical stimulation to the brain in response to detected seizure activity.”
An artificial intelligence that increases simulated brain–computer interface performance
Olsen, S., Zhang, J., Liang, K.-F., Lam, M., Riaz, U., & Kao, J. C. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abfaaa · Cited by 19
“…2015, Pandarinath et al 2017, Nuyujukian et al 2018), electroencephalographic (Wolpaw and McFarland 2004, McFar-land et al 2010, Edelman et al 2019), or electrocor-ticographic (Leuthardt et al 2004, Chao et al 2010, Wang et al 2013, Rouse et al 2016, Degenhart et al 2018, Silversmith et al 2021).”
BackgroundChen, K., Forrest, A. M., Burgos, G.-G., & Kozai, T. D. Y. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad5049 · Cited by 18
“However, the gradual decline in recording quality during long-term implantation leads to the instability of BCI decoders over time creating a major challenge in their clinical application [9, 14, 24, 90].”
BackgroundHerron, J. A., Kullmann, F. A., Denison, T., Goodman, W. K., Gunduz, A., Neumann, W., Provenza, N. R., Shanechi, M. M., Sheth, S. A., Starr, P. A., et al. (2024) · Nature Biomedical Engineering · doi:10.1038/s41551-024-01314-3 · Cited by 25
“A subacute grid was used for investigational use 50 but it required manual fabrication and the testing of a small batch of repurposed electrodes (R. Franklin, Blackrock Neurotechnology, personal communication).”
Zhou, E., Wang, X., Liang, J., Liu, Y., Yang, Q., Ran, X., Xia, L., Zou, X., Liu, C., Sun, L., et al. (2025) · Advanced Science · doi:10.1002/advs.202506663 · Cited by 22
Impact of dataset size and long-term ECoG-based BCI usage on deep learning decoders performance
Śliwowski, M., Martin, M., Souloumiac, A., Blanchart, P., & Aksenova, T. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1111645 · Cited by 23
“The decoders used are Kalman filters (Pistohl et al., 2012; Silversmith et al., 2020) and mostly variants of linear models (Flamary and Rakotomamonjy, 2012; Liang and Bougrain, 2012; Nakanishi et al.”
Rácz, F. S., Kumar, S., Kaposzta, Z., Alawieh, H., Liu, D. H., Liu, R., Czoch, A., Mukli, P., & Millán, J. D. R. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1271831 · Cited by 16
5-year follow-up of a fully implanted brain–computer interface in a spinal cord injury patient
Davis, K., Wyse‐Sookoo, K., Raza, F., Meschede-Krasa, B., Prins, N. W., Fisher, L., Brown, E. N., Cajigas, I., Ivan, M. E., Jagid, J. R., et al. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adc48c · Cited by 21
“Importantly, the stability and utility of human ECoG signals across time have been previously described [24, 52, 53, 94, 95], however, here we present these data in a community setting outside of the laboratory.”
A subdural CMOS optical device for bidirectional neural interfacing
Pollmann, E. H., Yin, H., Uguz, I., Dubey, A., Wingel, K., Choi, J. S., Moazeni, S., Gilhotra, Y., Andino-Pavlovsky, V., Banees, A., et al. (2024) · Nature Electronics · doi:10.1038/s41928-024-01209-w · Cited by 25
“824 ) is comparable to electrical signals in ECoG ( ρ = 0.9) 47 .”
InfluentialLong-term unsupervised recalibration of cursor BCIsPreprint
Wilson, G. H., Willett, F. R., Stein, E. A., Kamdar, F. B., Avansino, D. T., Hochberg, L. R., Shenoy, K. V., Druckmann, S., & Henderson, J. M. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.02.03.527022 · Cited by 14
“An alternative approach that has been explored is the use of electrocorticography (ECoG) signals, which involves recording electrical activity from the surface of the brain with coarser electrode grids 2 .”
BackgroundMethodInfluentialWilson, G. H., Stein, E. A., Kamdar, F. B., Avansino, D. T., Pun, T. K., Gross, R., Hosman, T., Singer-Clark, T., Kapitonava, A., Hochberg, L. R., et al. (2025) · Nature Biomedical Engineering · doi:10.1038/s41551-025-01536-z · Cited by 40
Visual tracking brain-computer interface
Huang, C., Shi, N., Miao, Y., Chen, X., Wang, Y., & Gao, X. (2024) · iScience · doi:10.1016/j.isci.2024.109376 · Cited by 19
“These results compare favorably to some spike-based BCIs, which have reported Fitt’s ITR of 0.4 bps 26 , although they fall below the highest recorded rates for individuals ranging from 1.4 to 4.2 bps 2 .”
MethodResultInfluentialResearch on Brain-Computer Interfaces in the Entertainment Field
Cavalcanti, D. D. Q., de Sá, F. M. F., Silva, T., Falcao, M. V., Cavalcanti, M. D., & Becker, V. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-35596-7_26 · Cited by 12
Sawyer, A., Cooke, L., Ramsey, N. F., & Putrino, D. F. (2023) · Journal of NeuroInterventional Surgery · doi:10.1136/jnis-2023-020316 · Cited by 13
Agudelo-Toro, A., Michaels, J. A., Sheng, W.-A., & Scherberger, H. (2024) · Neuron · doi:10.1016/j.neuron.2024.09.018 · Cited by 13
Iwama, S., & Ushiba, J. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3365197 · Cited by 10
“…posit that the proposed algorithm for rapid IAF determination is of potential utility for any other neural oscillations such as occipital alpha which reflects activities of visual cortices [35], [53], application of ECoG-based BCIs leveraging neural oscillatory features as decoder inputs [6], [8].”
BackgroundAssistive sensory-motor perturbations influence learned neural representationsPreprint
Rajeswaran, P., Payeur, A., Lajoie, G., & Orsborn, A. L. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.03.20.585972 · Cited by 9
“Decoder adaptation therefore creates a dynamic mapping between neural activity and motor outcomes and yet, adaptive decoders can produce consistent, skillfull BCI control over many practice sessions [13, 23, 30, 38].”
InfluentialMadduri, M. M., Yamagami, M., Li, S. J., Burckhardt, S. N., Burden, S. A., & Orsborn, A. L. (2026) · Nature Machine Intelligence · doi:10.1038/s42256-026-01194-z · Cited by 17
Active dissociation of intracortical spiking and high gamma activity
Lei, T., Scheid, M. R., Flint, R. D., Glaser, J. I., & Slutzky, M. W. (2026) · Nature · doi:10.1038/s41586-026-10331-y · Cited by 19
Müller-Putz, G., Mondini, V., Martínez-Cagigal, V., Kobler, R. J., Pereira, J., Lopes-Dias, C., Hehenberger, L., & Sburlea, A. I. (2021) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner49283.2021.9441346 · Cited by 10
Flint, R. D., Li, Y., Wang, P. T., Vaidya, M., Barry, A. J., Ghassemi, M., Tomic, G., Brkic, N., Ripley, D. L., Liu, C. Y., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7004 · Cited by 8
Human-Centered Shared Autonomy for Motor Planning, Learning, and Control Applications
Farhadi, M. H., Rabiee, A., Ghafoori, S., Cetera, A., Xu, W., & Abiri, R. (2025) · Springer eBooks · doi:10.1007/978-3-032-06713-5_14 · Cited by 12
Self-citationIterative alignment discovery of speech-associated neural activity
Rabbani, Q., Shah, S., Milsap, G., Fifer, M. S., Heřmanský, H., & Crone, N. E. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad663c · Cited by 7
An, Y., Mitchell, D., Lathrop, J., Flynn, D., & Chung, S. (2024) · IEEE Conference on Telepresence · doi:10.1109/telepresence63209.2024.10841769 · Cited by 8
“BCIs collect brain responses, process the signals, and convert them into commands for robots or end effectors to perform the user’s intended actions [7]–[9].”
A System for Graphical Visualization of Brainwaves to Analyse Media Content Consumption
Becker, V., Cavalcanti, M. D., Silva, T., Vasconcelos, E., Pinon, A., & de Sá, F. M. F. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-05409-9_24 · Cited by 9
Silva, A. B., Liu, J. R., Anderson, V. R., Kurtz-Miott, C. M., Hallinan, I. P., Littlejohn, K. T., Brosler, S., Tu-Chan, A., Ganguly, K., Moses, D. A., et al. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adf50e · Cited by 7
Self-citationFarzan, F. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95730-4.00003-2 · Cited by 8
Iwama, S., Zhang, Y., & Ushiba, J. (2022) · eNeuro · doi:10.1523/eneuro.0145-22.2022 · Cited by 6
“While previous BCI studies have demonstrated the long-term co-adaptation is one successful strategy for efficient training (Perdikis et al., 2018; Silversmith et al., 2021), however, the limited amount of training period in the study did not elicit the adaptation of neural activity patterns by the…”
BackgroundChen, Z., Huang, X., Xia, N. L., Gu, M., Xu, J., Lu, M., Chen, H., Xiong, C., & Chen, Y. (2025) · Research · doi:10.34133/research.0942 · Cited by 4
Individualized brain-computer interface for people with disabilities: a review
Saha, S., Karlsson, P., Anderson, C. J., Kavehei, O., & McEwan, A. L. (2026) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2026.1738876 · Cited by 6
“BCI-driven neurofeedback has been reported to regulate the cortical-subcortical networks and assists in modulating brain signals for cognitive or functional recovery (Silversmith et al., 2021; Sitaram et al., 2017; Orsborn et al., 2014).”
Simultaneous speech and gesture decoding for multimodal communication in paralysis
Brosler, S., Liu, J. R., Silva, A. B., Hallinan, I. P., Kurtz-Miott, C. M., Wilker, J. D., Tu-Chan, A., Ganguly, K., & Chang, E. F. (2026) · Nature Neuroscience · doi:10.1038/s41593-026-02446-2 · Cited by 6
Self-citationI Know What You're Thinking; Can Neuroimaging Truly Reveal Our Innermost Thoughts?
Straiton, J. (2023) · BioTechniques · doi:10.2144/btn-2023-0066 · Cited by 5
Neurosurgery and the Brain-Computer Interface
Rosenfeld, J. V. (2024) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-64892-2_32 · Cited by 8
Guggisberg, A. G., Siebner, H. R., Lundell, H., Madsen, M. A. J., Madsen, K. H., Wiggermann, V., Mégevand, P., Proix, T., Dalal, S. S., Grouiller, F., et al. (2025) · Clinical Neurophysiology · doi:10.1016/j.clinph.2025.2110942 · Cited by 5
Ouchi, T., Scholl, L. R., Rajeswaran, P., Canfield, R. A., Smith, L. I., & Orsborn, A. L. (2025) · Journal of Neuroscience · doi:10.1523/jneurosci.1536-24.2025 · Cited by 6
Multi-block RNN Autoencoders Enable Broadband ECoG Signal ReconstructionPreprint
Nolan, M. A., Pesaran, B., Shlizerman, E., & Orsborn, A. L. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.09.07.507004 · Cited by 6
“This will enable the expansion of dynamical systems methods and analysis to direct modeling of mesoscale measures of neural activity that show great promise for brain-computer interfaces and other neural devices [15, 16].”
BackgroundMethodThe ‘Brussels 4’: essential requirements for implantable brain–computer interface user autonomy
Oxley, T. J., Deo, D. R., Cernera, S., Sawyer, A., Putrino, D. F., Ramsey, N. F., & Fry, A. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ada0e6 · Cited by 7
“Frequent decoder recalibration may also impede the consolidation of control strategies and lead to performance variability across days [15, 33].”
STREAMS: An Assistive Multimodal AI Framework for Empowering Biosignal Based Robotic Controls
Rabiee, A., Ghafoori, S., Bai, X., Farhadi, M., Ostadabbas, S., & Abiri, R. (2025) · International Conference on Artificial Intelligence, Robotics and Control (AIRC) · doi:10.1109/airc64931.2025.11077565 · Cited by 9
“…biosignal based control approaches and their associated decoders are not able to generate stable outputs (trajectories) particularly when facing the challenge of continuous control of an end-effector based system (e.g. computer cursor) for accurate target acquisition (Fig 1) [11], [12].”
InfluentialSelf-citationDecoding four hand gestures with a single bipolar pair of electrocorticography electrodes
Verwoert, M., Vansteensel, M. J., Freudenburg, Z. V., Aarnoutse, E. J., Leijten, F. S. S., Ramsey, N. F., & Branco, M. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2c9f · Cited by 4
Timescales of Local and Cross-Area Interactions during Neuroprosthetic Learning
Derosier, K., Veuthey, T. L., & Ganguly, K. (2021) · Journal of Neuroscience · doi:10.1523/jneurosci.1397-21.2021 · Cited by 3
Self-citationMaking Video Games More Inclusive for People Living With Motor Neuron Disease: Scoping Review
O’Mara, B., Harrison, M., Harley, K., & Dwyer, N. (2024) · JMIR Rehabilitation and Assistive Technologies · doi:10.2196/58828 · Cited by 3
“BCIs were the most common interface studied across all categories [37,39,40,42,46-50, 53, 57, Gray literature, including information resources, guidelines, and lived experience stories, generally focused on customized video game software (including accessibility features in games and gameplay) and…”
How Does Artificial Intelligence Contribute to iEEG Research?
Berezutskaya, J., Saive, A.-L., Jerbi, K., & van Gerven, M. A. J. (2023) · Studies in neuroscience, psychology and behavioral economics · doi:10.1007/978-3-031-20910-9_47 · Cited by 5
Brain Computer Interface: Future, Challenges, and Potential ThreatsPreprint
Maiseli, B. J., Massawe, L. V., Mbise, M. E., Mkocha, K., Ally, N., Ismail, M., Michael, J., & Kimambo, S. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4073630 · Cited by 3
Generative AI for brain-computer interfaces decoding: Advances, challenges and future
Guo, Y., Ren, G., Ma, S., Zhou, J., Al-Nashash, H. A., Jolfaei, A., Zhang, Z., Li, G., Li, Y., Hu, Y., et al. (2026) · The Innovation Medicine · doi:10.59717/j.xinn-med.2026.100193 · Cited by 8
Cellular mechano-memory informs biomaterials and mechano-medicine
Qiao, P., Zhao, H., Ma, Z., Hasani, M., & Song, Y. (2026) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2026.103308 · Cited by 3
Liu, L., & Zeng, X. (2024) · Journal of Aging and Rehabilitation · doi:10.1097/jagr.0000000000000022 · Cited by 2
“59 Pels fully implanting ECoG-BCI under the dural, using the attempted action of the right hand, the user was able to generate a “ brain click ” for letter or word selection in the communication program with a high (89”
Metadata
- Authors
- Silversmith, D. B., Abiri, R., Hardy, N. F., Natraj, N., Tu-Chan, A., Chang, E. F., & Ganguly, K.
- Affiliations
- San Francisco VA Medical Center (US)
- University of California, San Francisco (US)
- Corresponding author
- Ganguly, Karunesh
- ORCID
- Venue
- Nature Biotechnology
- Published
- 2020-09-07
- Volume
- 39
- Issue
- 3
- Pages
- 326-335
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W3083554171
- Semantic Scholar
- 3ce94f8bf29734a289a4c42e903eb6f1cdb4dada
- Cited by
- 126
- References
- 74
- Citations by year
- 2026: 12 · 2025: 28 · 2024: 32 · 2023: 22 · 2022: 17 · 2021: 15
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Doris Duke Charitable Foundation (2013101)
- U.S. Department of Health & Human Services | NIH | NICHD | National Center for Medical Rehabilitation Research (1 DP2 HD087955)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- brain-computer interface, plug-and-play control, recalibration, neuroplasticity, paralysis, motor impairment, assistive devices
- MeSH terms
- Adaptation, Physiological, Brain Mapping, Electroencephalography, Humans, Motor Cortex, Neuronal Plasticity, Paralysis, Psychomotor Performance, Self-Help Devices, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.