Fully implantable and bioresorbable cardiac pacemakers without leads or batteries
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Temporary cardiac pacemakers used in periods of need during surgical recovery involve percutaneous leads and externalized hardware that carry risks of infection, constrain patient mobility and may damage the heart during lead removal. Here we report a leadless, battery-free, fully implantable cardiac pacemaker for postoperative control of cardiac rate and rhythm that undergoes complete dissolution and clearance by natural biological processes after a defined operating timeframe. We show that these devices provide effective pacing of hearts of various sizes in mouse, rat, rabbit, canine and human cardiac models, with tailored geometries and operation timescales, powered by wireless energy transfer. This approach overcomes key disadvantages of traditional temporary pacing devices and may serve as the basis for the next generation of postoperative temporary pacing technology. A biodegradable pacemaker without external leads improves the safety of temporary cardiac pacing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
Kurs, A., Karalis, A., Moffatt, R., Joannopoulos, J. D., Fisher, P., & Soljačić, M. (2007) · Science · doi:10.1126/science.1143254 · Cited by 5,576
Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier
Makadia, H. K., & Siegel, S. J. (2011) · Polymers · doi:10.3390/polym3031377 · Cited by 4,816
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
On the adsorption of proteins on solid surfaces, a common but very complicated phenomenon
Nakanishi, K., Sakiyama, T., & Imamura, K. (2001) · Journal of Bioscience and Bioengineering · doi:10.1016/s1389-1723(01)80127-4 · Cited by 1,006
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
Self-citationPoly(ethylene oxide) Grafted to Silicon Surfaces: Grafting Density and Protein Adsorption
Sofia, S. J., Premnath, V., & Merrill, E. W. (1998) · Macromolecules · doi:10.1021/ma971016l · Cited by 610
Koo, J., MacEwan, M. R., Kang, S.-K., Won, S. M., Stephen, M., Gamble, P., Xie, Z., Yan, Y., Chen, Y.-Y., Shin, J., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0196-2 · Cited by 496
Self-citationDissolvable Metals for Transient Electronics
Yin, L., Cheng, H., Mao, S., Haasch, R., Liu, Y., Xie, X., Hwang, S., Jain, H., Kang, S., Su, Y., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201301847 · Cited by 487
Self-citationCurrent and Novel Techniques for Metal Artifact Reduction at CT: Practical Guide for Radiologists
Katsura, M., Sato, J., Akahane, M., Kunimatsu, A., & Abe, O. (2018) · RadioGraphics · doi:10.1148/rg.2018170102 · Cited by 343
Choi, Y. S., Hsueh, Y.-Y., Koo, J., Yang, Q., Avila, R., Hu, B., Xie, Z., Lee, G., Ning, Z., Liu, C., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19660-6 · Cited by 292
Self-citationBailey, W. H., Harrington, T., Hirata, A., Kavet, R. R., Keshvari, J., Klauenberg, B. J., Legros, A., Maxson, D. P., Osepchuk, J. M., Reilly, J. P., et al. (2019) · IEEE Access · doi:10.1109/access.2019.2954823 · Cited by 251
Gutruf, P., Yin, R. T., Lee, K. B., Ausra, J., Brennan, J. A., Qiao, Y., Xie, Z., Peralta, R., Talarico, O., Murillo, A., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-13637-w · Cited by 220
Self-citationAnimal models of arrhythmia: classic electrophysiology to genetically modified large animals
Clauss, S., Bleyer, C., Schüttler, D., Tomsits, P., Renner, S., Klymiuk, N., Wakili, R., Massberg, S., Wolf, E., & Kääb, S. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-019-0179-0 · Cited by 216
External noninvasive temporary cardiac pacing: clinical trials.
Zoll, P. M., Zoll, R. H., Falk, R. H., Clinton, J. E., Eitel, D. R., & Antman, E. M. (1985) · Circulation · doi:10.1161/01.cir.71.5.937 · Cited by 202
Hwang, S.-W., Park, G., Edwards, C., Corbin, E. A., Kang, S.-K., Cheng, H., Song, J.-K., Kim, J.-H., Yu, S., Ng, J., et al. (2014) · ACS Nano · doi:10.1021/nn500847g · Cited by 202
Self-citationPermanent pacemaker infections: Characterization and management
Choo, M. H., Holmes, D. R., Gersh, B. J., Maloney, J. D., Merideth, J., Pluth, J. R., & Trusty, J. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90088-6 · Cited by 177
Koo, J., Kim, S. B., Choi, Y. S., Xie, Z., Bandodkar, A. J., Khalifeh, J., Yan, Y., Kim, H., Pezhouh, M. K., Doty, K., et al. (2020) · Science Advances · doi:10.1126/sciadv.abb1093 · Cited by 160
Self-citationAnalysis of pacemaker malfunction and complications of temporary pacing in the coronary care unit
Austin, J. L., Preis, L. K., Crampton, R. S., Beller, G., & Martin, R. P. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)90505-7 · Cited by 153
Natural Wax for Transient Electronics
Won, S. M., Koo, J., Crawford, K. E., Mickle, A. D., Xue, Y., Min, S., McIlvried, L. A., Yan, Y., Kim, S. B., Lee, S. M., et al. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201801819 · Cited by 126
Self-citationBiodegradable Polyanhydrides as Encapsulation Layers for Transient Electronics
Choi, Y. S., Koo, J., Lee, Y. J., Lee, G., Avila, R. O., Ying, H., Reeder, J. T., Hambitzer, L., Im, K., Jungwon, K., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202000941 · Cited by 124
Self-citationMechanisms for Hydrolysis of Silicon Nanomembranes as Used in Bioresorbable Electronics
Yin, L., Farimani, A. B., Min, K., Nandigana, V. V. R., Lam, J., Lee, Y., Aluru, N. R., & Rogers, J. A. (2015) · Advanced Materials · doi:10.1002/adma.201404579 · Cited by 121
Self-citationLee, Y. K., Yu, K. J., Song, E., Barati Farimani, A., Vitale, F., Xie, Z., Yoon, Y., Kim, Y., Richardson, A., Luan, H., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b06697 · Cited by 109
Self-citationBRAUN, M. U., RAUWOLF, T., BOCK, M., KAPPERT, U., BOSCHERI, A., SCHNABEL, A., & STRASSER, R. H. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00454.x · Cited by 105
Temporary Epicardial Pacing after Open Heart Surgery: Complications and Prevention
del Nido, P. J., & Goldman, B. S. (1989) · Journal of Cardiac Surgery · doi:10.1111/j.1540-8191.1989.tb00262.x · Cited by 96
Inorganic materials for transient electronics in biomedical applications
Choi, Y. S., Koo, J., & Rogers, J. A. (2020) · MRS Bulletin · doi:10.1557/mrs.2020.25 · Cited by 91
Self-citationLee, G., Choi, Y. S., Yoon, H., & Rogers, J. A. (2020) · Matter · doi:10.1016/j.matt.2020.08.021 · Cited by 90
Self-citationPermanent Pacemakers: 8-Year Follow-Up Study
Bernstein, V., ROTEM, C. E., & PERETZ, D. I. (1971) · Annals of Internal Medicine · doi:10.7326/0003-4819-74-3-361 · Cited by 89
Electrical Impedance Properties of Normal and Chronically Infarcted Left Ventricular Myocardium
Schwartzman, D. A., Chang, I. A., Michele, J. J., Mirotznik, M. S., & Foster, K. R. (1999) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1009887306055 · Cited by 85
Cardiac Pacemaker Infection: Surgical Management With and Without Extracorporeal Circulation
Wilhelm, M. J., Schmid, Ç., Hammel, D., Kerber, S., Loick, H. M., Herrmann, M., & Scheld, H. H. (1997) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(97)00989-2 · Cited by 81
Extending the limits of wireless power transfer to miniaturized implantable electronic devices
Dinis, H., Colmiais, I., & Mendes, P. (2017) · Micromachines · doi:10.3390/mi8120359 · Cited by 59
Electrical Impedance of Cardiac Muscle
Sperelakis, N., & Hoshiko, T. (1961) · Circulation Research · doi:10.1161/01.res.9.6.1280 · Cited by 59
Prophylactic antibiotics and the insertion of permanent transvenous cardiac pacemakers
Hartstein, A. I., Jackson, J., & Gilbert, D. N. (1978) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)41289-0 · Cited by 52
Evaluation of the Skin-To-Heart Distance in the Standing Adult by Two-Dimensional Echocardiography
Rahko, P. S. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.10.027 · Cited by 52
Effects of age, sex, and breeding status on the rat heart
Shreiner, D., Weisfeldt, M. L., & Shock, N. W. (1969) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1969.217.1.176 · Cited by 52
Fry, C. H., Salvage, S. C., Manazza, A., Dupont, E., Labeed, F. H., Hughes, M. P., & Jabr, R. I. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2012.10.023 · Cited by 34
Winter, K.-F., Hartmann, R., & Klinke, R. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)00160-x · Cited by 22
Chemical and structural characterization of Candelilla (Euphorbia antisyphilitica Zucc.)
Rojas-Molina, R., León-Zapata, M. Á. D., Saucedo-Pompa, S., Aguilar-González, M. Á., & Aguilar, C. N. (2013) · Journal of Medicinal Plants Research · doi:10.5897/jmpr11.321 · Cited by 18
Actions of neurotransmitters and peptides on longitudinal and circular muscle of the rat portal vein
Mathison, R. D. (1983) · Journal of Pharmacy and Pharmacology · doi:10.1111/j.2042-7158.1983.tb04259.x · Cited by 17
George, S. A., Brennan, J. A., & Efimov, I. R. (2020) · Journal of Visualized Experiments · doi:10.3791/60781 · Cited by 16
Self-citation
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationWearable Pressure Sensors for Pulse Wave Monitoring
Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., Xiao, X., & Chen, J. (2022) · Advanced Materials · doi:10.1002/adma.202109357 · Cited by 878
Topological supramolecular network enabled high-conductivity, stretchable organic bioelectronics
Jiang, Y., Zhang, Z., Wang, Y.-X., Li, D., Coen, C.-T., Hwaun, E., Chen, G., Wu, H.-C., Zhong, D., Niu, S., et al. (2022) · Science · doi:10.1126/science.abj7564 · Cited by 617
Self-citationMaterials-Driven Soft Wearable Bioelectronics for Connected Healthcare
Gong, S., Lu, Y., Yin, J., Levin, A., & Cheng, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00502 · Cited by 411
Skin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Metadata
- Authors
- Choi, Y. S., Yin, R. T., Pfenniger, A., Koo, J., Avila, R., Benjamin Lee, K., Chen, S. W., Lee, G., Li, G., Qiao, Y., Murillo-Berlioz, A., Kiss, A., Han, S., Lee, S. M., Li, C., Xie, Z., Chen, Y.-Y., Burrell, A., Geist, B., Jeong, H., Kim, J., Yoon, H.-J., Banks, A., Kang, S.-K., Zhang, Z. J., Haney, C. R., Sahakian, A. V., Johnson, D., Efimova, T., Huang, Y., Trachiotis, G. D., Knight, B. P., Arora, R. K., Efimov, I. R., & Rogers, J. A.
- Venue
- Nature Biotechnology
- Published
- 2021-06-28
- Volume
- 39
- Issue
- 10
- Pages
- 1228-1238
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W3175547357
- Cited by
- 361
- References
- 40
- FWCI
- 34.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.