Field-Effect Transistor Biosensor for Rapid Detection of Ebola Antigen
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
The Ebola virus transmits a highly contagious, frequently fatal human disease for which there is no specific antiviral treatment. Therefore, rapid, accurate, and early diagnosis of Ebola virus disease (EVD) is critical to public health containment efforts, particularly in developing countries where resources are few and EVD is endemic. We have developed a reduced graphene oxide-based field-effect transistor method for real-time detection of the Ebola virus antigen. This method uses the attractive semiconductor characteristics of graphene-based material, and instantaneously yields highly sensitive and specific detection of Ebola glycoprotein. The feasibility of this method for clinical application in point-of-care technology is evaluated using Ebola glycoprotein suspended in diluted PBS buffer, human serum, and plasma. These results demonstrate the successful fabrication of a promising field-effect transistor biosensor for EVD diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ebola virus disease in West Africa—the first 9 months of the epidemic and forward projections
WHO Ebola Response Team (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1411100 · Cited by 1,674
Emergence of Zaire Ebola Virus Disease in Guinea
Baize, S., Pannetier, D., Oestereich, L., Rieger, T., Koivogui, L., Magassouba, N., Soropogui, B., Sow, M. S., Keïta, S., De Clerck, H., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1404505 · Cited by 1,366
Genomic surveillance elucidates Ebola virus origin and transmission during the 2014 outbreak
Gire, S. K., Goba, A., Andersen, K. G., Sealfon, R. S. G., Park, D. J., Kanneh, L., Jalloh, S., Momoh, M., Fullah, M., Dudas, G., et al. (2014) · Science · doi:10.1126/science.1259657 · Cited by 1,215
Henao-Restrepo, A. M., Longini, I. M., Egger, M., Dean, N. E., Edmunds, W. J., Camacho, A., Carroll, M. W., Doumbia, M., Draguez, B., Duraffour, S., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)61117-5 · Cited by 793
Reduced graphene oxide for room-temperature gas sensors
Lu, G., Ocola, L. E., & Chen, J. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/44/445502 · Cited by 775
Self-citationUltrahigh sensitivity and layer-dependent sensing performance of phosphorene-based gas sensors
Cui, S., Pu, H., Wells, S. A., Wen, Z., Mao, S., Chang, J., Hersam, M. C., & Chen, J. (2015) · Nature Communications · doi:10.1038/ncomms9632 · Cited by 763
Self-citationAbbas, A. N., Liu, B., Chen, L., Ma, Y., Cong, S., Aroonyadet, N., Köpf, M., Nilges, T., & Zhou, C. (2015) · ACS Nano · doi:10.1021/acsnano.5b01961 · Cited by 735
Assessment of the Risk of Ebola Virus Transmission from Bodily Fluids and Fomites
Bausch, D. G., Towner, J. S., Dowell, S. F., Kaducu, F., Lukwiya, M., Sanchez, A., Nichol, S. T., Ksiazek, T. G., & Rollin, P. E. (2007) · The Journal of Infectious Diseases · doi:10.1086/520545 · Cited by 522
Mao, S., Lu, G., Yu, K., Bo, Z., & Chen, J. (2010) · Advanced Materials · doi:10.1002/adma.201000520 · Cited by 471
Self-citationAn Optofluidic Nanoplasmonic Biosensor for Direct Detection of Live Viruses from Biological Media
Yanik, A. A., Huang, M., Kamohara, O., Artar, A., Geisbert, T. W., Connor, J. H., & Altug, H. (2010) · Nano Letters · doi:10.1021/nl103025u · Cited by 454
Xu, S., Zhan, J., Man, B., Jiang, S., Yue, W., Gao, S., Guo, C., Liu, H., Li, Z., Wang, J., et al. (2017) · Nature Communications · doi:10.1038/ncomms14902 · Cited by 437
Nabel, G. J., Yang, Z., Duckers, H. J., Sullivan, N. J., Sanchez, A., & Nabel, E. G. (2000) · Nature Medicine · doi:10.1038/78645 · Cited by 413
Nanozyme-strip for rapid local diagnosis of Ebola
Duan, D., Fan, K., Zhang, D., Tan, S., Liang, M., Liu, Y., Zhang, J., Zhang, P., Liu, W., Qiu, X., et al. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.025 · Cited by 388
Graphene-based biosensors for detection of bacteria and their metabolic activities
Huang, Y., Dong, X., Liu, Y., Li, L.-J., & Chen, P. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm11436k · Cited by 375
Ksiazek, T. G., Rollin, P. E., Williams, A. J., Bressler, D. S., Martin, M. L., Swanepoel, R., Burt, F. J., Leman, P. A., Khan, A. S., Rowe, A. K., et al. (1999) · The Journal of Infectious Diseases · doi:10.1086/514321 · Cited by 359
Yen, C.-W., de Puig, H., Tam, J. O., Gómez-Márquez, J., Bosch, I., Hamad-Schifferli, K., & Gehrke, L. (2015) · Lab on a Chip · doi:10.1039/c5lc00055f · Cited by 308
Volchkov, V. E., Volchkova, V. A., Mühlberger, E., Kolesnikova, L. V., Weik, M., Dolnik, O., & Klenk, H.-D. (2001) · Science · doi:10.1126/science.1057269 · Cited by 303
Tuning gas-sensing properties of reduced graphene oxide using tin oxide nanocrystals
Mao, S., Cui, S., Lu, G., Yu, K., Wen, Z., & Chen, J. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm30378g · Cited by 284
Self-citationEbolavirus Glycoprotein Structure and Mechanism of Entry
Lee, J. E., & Saphire, E. O. (2009) · Future Virology · doi:10.2217/fvl.09.56 · Cited by 281
Field-effect transistor biosensors with two-dimensional black phosphorus nanosheets
Chen, Y., Ren, R., Pu, H., Chang, J., Mao, S., & Chen, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.03.059 · Cited by 261
Self-citationChen, K., Lu, G., Chang, J., Mao, S., Yu, K., Cui, S., & Chen, J. (2012) · Analytical Chemistry · doi:10.1021/ac3000336 · Cited by 253
Self-citationChu, C.-H., Sarangadharan, I., Regmi, A., Chen, Y.-W., Hsu, C.-P., Chang, W.-H., Lee, G.-Y., Chyi, J.-I., Chen, C.-C., Shiesh, S.-C., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-05426-6 · Cited by 245
Self-citationBroadhurst, M. J., Kelly, J. D., Miller, A., Semper, A., Bailey, D., Groppelli, E., Simpson, A., Brooks, T., Hula, S., Nyoni, W., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)61042-x · Cited by 205
Direct Growth of Vertically-oriented Graphene for Field-Effect Transistor Biosensor
Mao, S., Yu, K., Chang, J., Steeber, D. A., Ocola, L. E., & Chen, J. (2013) · Scientific Reports · doi:10.1038/srep01696 · Cited by 204
Self-citationBeeching, N. J., Fenech, M., & Houlihan, C. F. (2014) · BMJ · doi:10.1136/bmj.g7348 · Cited by 180
Possible sexual transmission of Ebola virus - Liberia, 2015.
Christie, A., Davies-Wayne, G., Cordier-Lassalle, T., Cordier-Lasalle, T., Blackley, D. J., Laney, A. S., Williams, D. E., Shinde, S. A., Badio, M., Lo, T., et al. (2015) · PubMed Central · Cited by 176
How Ebola and Marburg viruses battle the immune system
Mohamadzadeh, M., Chen, L., & Schmaljohn, A. L. (2007) · Nature reviews. Immunology · doi:10.1038/nri2098 · Cited by 161
Zhou, G., Chang, J., Cui, S., Pu, H., Wen, Z., & Chen, J. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am505275a · Cited by 140
Self-citationEnzyme immunosorbent assay for Ebola virus antigens in tissues of infected primates
Ksiazek, T. G., Rollin, P. E., Jahrling, P. B., Johnson, E. D., Dalgard, D. W., & Peters, C. J. (1992) · Journal of Clinical Microbiology · doi:10.1128/jcm.30.4.947-950.1992 · Cited by 132
Optofluidic analysis system for amplification-free, direct detection of Ebola infection
Cai, H., Parks, J. W., Wall, T. A., Stott, M. A., Stambaugh, A., Alfson, K., Griffiths, A., Mathies, R. A., Carrion, R., Patterson, J. L., et al. (2015) · Scientific Reports · doi:10.1038/srep14494 · Cited by 123
Daaboul, G. G., A, C. A. L., Chinnala, J., Goldberg, B. B., Connor, J. H., & Ünlü, M. S. (2014) · ACS Nano · doi:10.1021/nn501312q · Cited by 105
Rapid, Label-Free, Electrical Whole Blood Bioassay Based on Nanobiosensor Systems
Chang, H.-K., Ishikawa, F. N., Zhang, R., Datar, R. H., Côté, R. J., Thompson, M. E., & Zhou, C. (2011) · ACS Nano · doi:10.1021/nn2035796 · Cited by 87
Mohan, G. S., Ye, L., Li, W., Monteiro, A. C., Lin, X., Sapkota, B., Pollack, B. P., Compans, R. W., & Yang, C. (2014) · Journal of Virology · doi:10.1128/jvi.01810-14 · Cited by 66
Chang, J., Mao, S., Zhang, Y., Cui, S., Steeber, D. A., & Chen, J. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.10.041 · Cited by 46
Self-citationDirect growth of graphene on quartz substrates for label-free detection of adenosine triphosphate
Xu, S., Man, B., Jiang, S., Yue, W., Yang, C., Liu, M., Chen, C., & Zhang, C. (2014) · Nanotechnology · doi:10.1088/0957-4484/25/16/165702 · Cited by 44
Liang, L., Hu, W., Xue, Z., & Shen, J. (2017) · FlatChem · doi:10.1016/j.flatc.2017.02.001 · Cited by 31
Cited by
Tracking virus outbreaks in the twenty-first century
Grubaugh, N. D., Ladner, J. T., Lemey, P., Pybus, O. G., Rambaut, A., Holmes, E. C., & Andersen, K. G. (2018) · Nature Microbiology · doi:10.1038/s41564-018-0296-2 · Cited by 485
Two-Dimensional Field-Effect Transistor Sensors: The Road toward Commercialization
Dai, C., Liu, Y., & Wei, D. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00924 · Cited by 303
Field-Effect Transistor Biosensors for Biomedical Applications: Recent Advances and Future Prospects
Vu, C.-A., & Chen, W.-Y. (2019) · Sensors · doi:10.3390/s19194214 · Cited by 238
“01 × PBS, HS, Human Plasma 1 ng/mL 1–444 ng/mL [84]”
ResultUltrasensitive detection of pathogenic viruses with electrochemical biosensor: State of the art
Khan, M. Z. H., Hasan, M. R., Hossain, S. I., Ahommed, M. S., & Daizy, M. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112431 · Cited by 224
Metadata
- Authors
- Chen, Y., Ren, R., Pu, H., Guo, X., Chang, J., Zhou, G., Mao, S., Kron, M., & Chen, J.
- Venue
- Scientific Reports
- Published
- 2017-09-08
- Volume
- 7
- Issue
- 1
- Pages
- 10974-10974
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2751201118
- Cited by
- 162
- References
- 36
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.