CoChat

Visuo-acoustic stimulation that helps you to relax: A virtual reality setup for patients in the intensive care unit

Open access

The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.

Abstract

After prolonged stay in an intensive care unit (ICU) patients often complain about cognitive impairments that affect health-related quality of life after discharge. The aim of this proof-of-concept study was to test the feasibility and effects of controlled visual and acoustic stimulation in a virtual reality (VR) setup in the ICU. The VR setup consisted of a head-mounted display in combination with an eye tracker and sensors to assess vital signs. The stimulation consisted of videos featuring natural scenes and was tested in 37 healthy participants in the ICU. The VR stimulation led to a reduction of heart rate (p = 0. 049) and blood pressure (p = 0.044). Fixation/saccade ratio (p < 0.001) was increased when a visual target was presented superimposed on the videos (reduced search activity), reflecting enhanced visual processing. Overall, the VR stimulation had a relaxing effect as shown in vital markers of physical stress and participants explored less when attending the target. Our study indicates that VR stimulation in ICU settings is feasible and beneficial for critically ill patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-017-13153-1

Cites

66 of 66 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Vital parameters pooled with oculomotor data of healthy participants (n = 37, age M = 48 years, SD = 17). The oculomotor data (fixation duration, number of fixations, saccade amplitudes and fixation/saccade ratio) is based on moving window calculations, whereas the vital sign measurements (MAP, HF, RF and SpO2) were sampled at each data points separately.
Figure 1 Vital parameters pooled with oculomotor data of healthy participants (n = 37, age M = 48 years, SD = 17). The oculomotor data (fixation duration, number of fixations, saccade amplitudes and fixation/saccade ratio) is based on moving window calculations, whereas the vital sign measurements (MAP, HF, RF and SpO2) were sampled at each data points separately.CC BY · PubMed Central
Figure 2 Participant lying on the bed in the ICU during stimulation, including the whole setup.
Figure 2 Participant lying on the bed in the ICU during stimulation, including the whole setup.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 66 references

Cited by

See all 151

Metadata

Authors
Gerber, S. M., Jeitziner, M.-M., Wyss, P., Chesham, A., Urwyler, P., Müri, R. M., Jakob, S. M., & Nef, T.
Affiliations
University of Bern (CH)
Corresponding author
Nef, Tobias
Venue
Scientific Reports
Published
2017-10-16
Volume
7
Issue
1
Pages
13228-13228
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2762490179
Cited by
151
References
66
Citations by year
2026: 14 · 2025: 16 · 2024: 23 · 2023: 24 · 2022: 21 · 2021: 27 · 2020: 14 · 2019: 11 · 2018: 1
FWCI
8.80
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • BORIS (University Library Bern) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Open Access CRIS of the University of Bern
Funders
  • University of Bern
  • Inselspital, Universitätsspital Bern
Topics
  • Physical Sciences › Computer Science › Human-Computer Interaction › Virtual Reality Applications and Impacts
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Intensive Care Unit Cognitive Disorders
  • Social Sciences › Psychology › Social Psychology › Music Therapy and Health
Keywords
virtual reality, intensive care unit, relaxation, head-mounted displays, eye tracking, heart rate, blood pressure, vital signs, visual processing, cognitive impairment, critically ill patients, stress reduction
MeSH terms
Virtual Reality, Acoustic Stimulation, Adult, Aged, Aged, 80 and over, Critical Care, Feasibility Studies, Female, Humans, Intensive Care Units, Male, Middle Aged, Photic Stimulation, Surveys and Questionnaires, Relaxation Therapy, Time Factors, Young Adult, Vital Signs

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Visuo-acoustic stimulation that helps you to relax: A virtual reality setup for patients in the intensive care unit. https://app.cochat.ai/papers/10.1038/s41598-017-13153-1
The paper
Gerber, S. M., Jeitziner, M.-M., Wyss, P., Chesham, A., Urwyler, P., Müri, R. M., Jakob, S. M., & Nef, T. (2017). Visuo-acoustic stimulation that helps you to relax: A virtual reality setup for patients in the intensive care unit. Scientific Reports. https://doi.org/10.1038/s41598-017-13153-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.