Detecting and classifying lesions in mammograms with Deep Learning
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
In the last two decades, Computer Aided Detection (CAD) systems were developed to help radiologists analyse screening mammograms, however benefits of current CAD technologies appear to be contradictory, therefore they should be improved to be ultimately considered useful. Since 2012, deep convolutional neural networks (CNN) have been a tremendous success in image recognition, reaching human performance. These methods have greatly surpassed the traditional approaches, which are similar to currently used CAD solutions. Deep CNN-s have the potential to revolutionize medical image analysis. We propose a CAD system based on one of the most successful object detection frameworks, Faster R-CNN. The system detects and classifies malignant or benign lesions on a mammogram without any human intervention. The proposed method sets the state of the art classification performance on the public INbreast database, AUC = 0.95. The approach described here has achieved 2nd place in the Digital Mammography DREAM Challenge with AUC = 0.85. When used as a detector, the system reaches high sensitivity with very few false positive marks per image on the INbreast dataset. Source code, the trained model and an OsiriX plugin are published online at https://github.com/riblidezso/frcnn_cad .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“eight91–98 studies validated algorithms on external data”
From Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis (2021) · cites this paper as [96]
In the citing paper
“Federated averaging FedAvg is a generalization of FedSGD [46], which allows local nodes to perform more than one batch update on local data and exchanges the updated weights rather than the gradients.”
From Memory-aware curriculum federated learning for breast cancer classification (2023) · cites this paper as [46]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Very Deep Convolutional Networks for Large-Scale Image Recognition
Simonyan, K., & Zisserman, A. (2014) · arXiv · doi:10.48550/arxiv.1409.1556 · Cited by 114,148
Faster R-CNN: Towards Real-Time Object Detection with Region Proposal Networks
Ren, S., He, K., Girshick, R., & Sun, J. (2017) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2016.2577031 · Cited by 73,472 · cited 3×
“During training we optimized the object detection part and the classifier part of the model in the same time, this is called the joint optimization [45].”
MethodFaster R-CNN: Towards Real-Time Object Detection with Region Proposal Networks
Ren, S., He, K., Girshick, R., & Sun, J. (2015) · arXiv · doi:10.48550/arxiv.1506.01497 · Cited by 70,812 · cited 3×
“During training we optimized the object detection part and the classifier part of the model in the same time, this is called the joint optimization [45].”
MethodAdvances in neural information processing systems 7
Cios, K., & Shields, M. (1997) · Neurocomputing · doi:10.1016/s0925-2312(97)90018-7 · Cited by 22,059
Delving Deep into Rectifiers: Surpassing Human-Level Performance on ImageNet Classification
He, K., Zhang, X., Ren, S., & Sun, J. (2015) · 2015 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2015.123 · Cited by 19,741
Caffe: Convolutional Architecture for Fast Feature Embedding
Jia, Y., Shelhamer, E., Donahue, J., Karayev, S., Long, J., Girshick, R., Guadarrama, S., & Darrell, T. (2014) · Proceedings of the 22nd ACM international conference on Multimedia · doi:10.1145/2647868.2654889 · Cited by 11,077 · cited 1×
“We have used the framework developed by the authors of Faster R-CNN [38], which was built in the Caffe framework for deep learning [25].”
MethodCaffe: Convolutional Architecture for Fast Feature Embedding
Jia, Y., Shelhamer, E., Donahue, J., Karayev, S., Long, J., Girshick, R., Guadarrama, S., & Darrell, T. J. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1408.5093 · Cited by 3,752 · cited 1×
“We have used the framework developed by the authors of Faster R-CNN [38], which was built in the Caffe framework for deep learning [25].”
MethodMoreira, I. C., Amaral, I., Domingues, I., Cardoso, A., Cardoso, M. J., & Cardoso, J. S. (2012) · Academic Radiology · doi:10.1016/j.acra.2011.09.014 · Cited by 1,177 · cited 15×
“We have also evaluated the model on the publicly available INbreast dataset.”
BackgroundMethodInfluentialTHE DIGITAL DATABASE FOR SCREENING MAMMOGRAPHY
Heath, M. D., Bowyer, K. W., Kopans, D. B., & Moore, R. M. (2007) · Cited by 1,017
Large scale deep learning for computer aided detection of mammographic lesions
Kooi, T., Litjens, G., van Ginneken, B., Gubern-Mérida, A., Sánchez, C. I., Mann, R., den Heeten, A., & Karssemeijer, N. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.07.007 · Cited by 965
Analysis of cancers missed at screening mammography.
Bird, R. E., Wallace, T. W., & Yankaskas, B. C. (1992) · Radiology · doi:10.1148/radiology.184.3.1509041 · Cited by 820
Freer, T. W., & Ulissey, M. J. (2001) · Radiology · doi:10.1148/radiol.2203001282 · Cited by 751
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678 · cited 3×
“Therefore the vast majority of cases which are recalled are false positives [41, 28, 27, 15, 32, 17, 43, 11].”
BackgroundInfluence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619 · cited 3×
“Therefore the vast majority of cases which are recalled are false positives [41, 28, 27, 15, 32, 17, 43, 11].”
BackgroundResultPotential Contribution of Computer-aided Detection to the Sensitivity of Screening Mammography
Warren Burhenne, L. J., Wood, S. A., D'Orsi, C. J., Feig, S. A., Kopans, D. B., O'Shaughnessy, K. F., Sickles, E. A., Tabar, L., Vyborny, C. J., & Castellino, R. A. (2000) · Radiology · doi:10.1148/radiology.215.2.r00ma15554 · Cited by 554
von Karsa, L., Anttila, A., Ronco, G., Ponti, A., Malila, N. K., Arbyn, M., Segnan, N., Castillo-Beltran, M., Boniol, M., Ferlay, J., et al. (2008) · Cited by 551
Broeders, M., Moss, S., Nyström, L., Njor, S., Jonsson, H., Paap, E., Massat, N., Duffy, S., Lynge, E., & Paci, E. (2012) · Journal of Medical Screening · doi:10.1258/jms.2012.012078 · Cited by 489 · cited 1×
“Mammographic screening was shown to reduce mortality by 38–48% among participants [7].”
BackgroundBirdwell, R. L., Ikeda, D. M., O’Shaughnessy, K. F., & Sickles, E. A. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap16192 · Cited by 428 · cited 12×
“These controversial results indicate that CAD systems need to be improved before radiologists can ultimately benefit from using the technology in everyday practice.”
BackgroundResultInfluentialBecker, A. S., Marcon, M., Ghafoor, S., Wurnig, M. C., Frauenfelder, T., & Boss, A. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000358 · Cited by 352
Single Reading with Computer-Aided Detection for Screening Mammography
Gilbert, F. J., Astley, S. M., Gillan, M. G. C., Agbaje, O. F., Wallis, M. G., James, J., Boggis, C. R. M., & Duffy, S. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0803545 · Cited by 296 · cited 3×
“Therefore the vast majority of cases which are recalled are false positives [41, 28, 27, 15, 32, 17, 43, 11].”
BackgroundBreast cancer missed by mammography
Martin, J., Moskowitz, M., & Milbrath (1979) · American Journal of Roentgenology · doi:10.2214/ajr.132.5.737 · Cited by 246 · cited 1×
“Multiple studies have shown that 20-30% of the diagnosed cancers could be found retrospectively on the previous negative screening exam by blinded reviewers [33, 3, 18, 4, 21, 1].”
BackgroundGlobal Burden of Breast Cancer
Ferlay, J., Héry, C., Autier, P., & Sankaranarayanan, R. (2010) · Breast Cancer Epidemiology · doi:10.1007/978-1-4419-0685-4_1 · Cited by 240 · cited 1×
“Mammographic screening Breast cancer is the most common cancer in women and it is the main cause of death from cancer among women in the world [16].”
BackgroundScreening Mammograms: Interpretation with Computer-aided Detection—Prospective Evaluation
Morton, M. J., Whaley, D. H., Brandt, K. R., & Amrami, K. K. (2006) · Radiology · doi:10.1148/radiol.2392042121 · Cited by 218
Bunch, P. C., Hamilton, J. F., Sanderson, G. K., & Simmons, A. H. (1977) · SPIE Proceedings · doi:10.1117/12.955926 · Cited by 212
Harvey, J. A., Fajardo, L. L., & Innis, C. A. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.161.6.8249720 · Cited by 195
Brem, R. F., Baum, J., Lechner, M., Kaplan, S., Souders, S., Naul, L. G., & Hoffmeister, J. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.3.1810687 · Cited by 189 · cited 11×
“These controversial results indicate that CAD systems need to be improved before radiologists can ultimately benefit from using the technology in everyday practice.”
ResultInfluentialBreast Cancer Detected with Screening US: Reasons for Nondetection at Mammography
Bae, M. S., Moon, W. K., Chang, J. M., Koo, H. R., Kim, W. H., Cho, N., Yi, A., La Yun, B., Lee, S. H., Kim, M. Y., et al. (2014) · Radiology · doi:10.1148/radiol.13130724 · Cited by 174
Effectiveness of Computer-Aided Detection in Community Mammography Practice
Fenton, J. J., Abraham, L., Taplin, S. H., Geller, B. M., Carney, P. A., D'Orsi, C., Elmore, J. G., Barlow, W. E., & for the Breast Cancer Surveillance Consortium (2011) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djr206 · Cited by 168
A Multi-scale CNN and Curriculum Learning Strategy for Mammogram Classification
Lotter, W., Sorensen, G., & Cox, D. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-67558-9_20 · Cited by 147 · cited 1×
“Several studies have attempted to apply Deep Learning to analyze mammograms [38, 35, 39, 40], but the problem is still far from being solved.”
BackgroundPhysician Predictors of Mammographic Accuracy
Smith-Bindman, R., Chu, P., Miglioretti, D. L., Quale, C., Rosenberg, R. D., Cutter, G., Geller, B., Bacchetti, P., Sickles, E. A., & Kerlikowske, K. (2005) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/dji060 · Cited by 145 · cited 2×
“The sensitivity of screening mammography is reported to be between 8090% [35, 9, 42, 37, 28, 27, 15, 32, 17, 2, 11].”
BackgroundComputer aided diagnosis of breast cancer in digitized mammograms
Christoyianni, I., Koutras, A., Dermatas, E., & Kokkinakis, G. (2002) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(02)00031-9 · Cited by 139 · cited 2×
“These programs usually analyze a mammogram and mark the suspicious regions, which should be reviewed by the radiologist [10].”
BackgroundMethodBlanks, R. G., Wallis, M., & Moss, S. (1998) · Journal of Medical Screening · doi:10.1136/jms.5.4.195 · Cited by 137
Banks, E., REEVES, G. K., Beral, V., Bull, D., Crossley, B., Simmonds, M., Hilton, E., Bailey, S., Barrett, N. K., Briers, P., et al. (2004) · BMJ · doi:10.1136/bmj.329.7464.477 · Cited by 123
Hoff, S. R., Abrahamsen, A.-L., Samset, J. H., Vigeland, E., Klepp, O., & Hofvind, S. S. H. (2012) · Radiology · doi:10.1148/radiol.12112074 · Cited by 121 · cited 5×
“The problem of missed cancers still persists despite modern full field digital mammography (FFDM) [4, 8].”
BackgroundInfluentialWill Machine Learning Tip the Balance in Breast Cancer Screening?
Trister, A. D., Buist, D. S. M., & Lee, C. I. (2017) · JAMA Oncology · doi:10.1001/jamaoncol.2017.0473 · Cited by 92
Ciatto, S., Turco, M. R. D., Risso, G. G., Catarzi, S., Bonardi, R., Viterbo, V., Gnutti, P., Guglielmoni, B., Pinelli, L., Pandiscia, A., et al. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00011-6 · Cited by 85
Fully automated classification of mammograms using deep residual neural networks
Dhungel, N., Carneiro, G., & Bradley, A. P. (2017) · 2017 IEEE 14th International Symposium on Biomedical Imaging (ISBI 2017) · doi:10.1109/isbi.2017.7950526 · Cited by 80 · cited 1×
“Several studies have attempted to apply Deep Learning to analyze mammograms [38, 35, 39, 40], but the problem is still far from being solved.”
BackgroundUse of Normal Tissue Context in Computer-Aided Detection of Masses in Mammograms
Hupse, R., & Karssemeijer, N. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2028611 · Cited by 62 · cited 1×
“Currently used CAD approaches are based on describing the X-ray image with meticulously designed hand crafted features, and machine learning for classification on top of these features [10, 22, 23, 24, 29] .”
MethodSadaf, A., Crystal, P., Scaranelo, A. M., & Helbich, T. H. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.08.024 · Cited by 51 · cited 1×
“The same criteria is generally used when measuring the performance of currently used CAD products [13, 39, 22].”
Kim, S. J., Moon, W. K., Cho, N., Cha, J. H., Kim, S. M., & Im, J.-G. (2008) · Radiology · doi:10.1148/radiol.2461062072 · Cited by 46
Evaluation of Computer-aided Detection Systems in the Detection of Small Invasive Breast Carcinoma
Ellis, R. L., Meade, A. A., Mathiason, M. A., Willison, K. M., & Logan-Young, W. W. (2007) · Radiology · doi:10.1148/radiol.2451060760 · Cited by 26 · cited 1×
“The same criteria is generally used when measuring the performance of currently used CAD products [13, 39, 22].”
BackgroundHupse, R., Samulski, M. R. M., Lobbes, M. B. I., den Heeten, A., Tas, M. W., Beijerinck, D., Pijnappel, R. M., Boetes, C., & Karssemeijer, N. (2012) · European Radiology · doi:10.1007/s00330-012-2562-7 · Cited by 23 · cited 1×
“Currently used CAD approaches are based on describing the X-ray image with meticulously designed hand crafted features, and machine learning for classification on top of these features [10, 22, 23, 24, 29] .”
MethodEffect of independent multiple reading of mammograms on detection performance
Karssemeijer, N., Otten, J. D. M., Roelofs, A. A. J., van Woudenberg, S., & Hendriks, J. H. C. L. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.535225 · Cited by 15
Cited by
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Narin, A., Kaya, C., & Pamuk, Z. (2021) · Pattern Analysis and Applications · doi:10.1007/s10044-021-00984-y · Cited by 2,054
“As a result of these analyzes, detection and diagnosis of diseases such as diabetes mellitus, brain tumor, skin cancer and breast cancer are provided with convenience [36-41].”
BackgroundArtificial intelligence in cancer imaging: Clinical challenges and applications
Bi, W. L., Hosny, A., Schabath, M. B., Giger, M. L., Birkbak, N. J., Mehrtash, A., Allison, T., Arnaout, O., Abbosh, C., Dunn, I. F., et al. (2019) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21552 · Cited by 1,846
Recent advances and clinical applications of deep learning in medical image analysis
Chen, X., Wang, X., Zhang, K., Fung, K.-M., Thai, T. C., Moore, K., Mannel, R. S., Liu, H., Zheng, B., & Qiu, Y. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102444 · Cited by 1,080
“Common computer-aided detection (CADe) tasks include detecting lung nodules (Gu et al., 2018; Xie et al., 2019b), breast masses (Akselrod-Ballin et al., 2017; Ribli et al., 2018), lymph nodes (Lin et al., 2019; Zhu et al., 2020b), sclerosis lesions (Nair et al., 2020), etc.”
BackgroundDeep Learning to Improve Breast Cancer Detection on Screening Mammography
Shen, L., Margolies, L. R., Rothstein, J. H., Fluder, E., McBride, R., & Sieh, W. (2019) · Scientific Reports · doi:10.1038/s41598-019-48995-4 · Cited by 873
Metadata
- Authors
- Ribli, D., Horváth, A., Unger, Z., Pollner, P., & Csabai, I.
- Affiliations
- Eötvös Loránd University (HU)
- Semmelweis University (HU)
- Corresponding author
- Ribli, Dezső
- Venue
- Scientific Reports
- Published
- 2018-03-15
- Volume
- 8
- Issue
- 1
- Pages
- 4165-4165
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC5854668
- OpenAlex
- W2737777915
- Cited by
- 696
- References
- 42
- Citations by year
- 2026: 37 · 2025: 78 · 2024: 81 · 2023: 81 · 2022: 103 · 2021: 111 · 2020: 104 · 2019: 83 · 2018: 18
- FWCI
- 44.52
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Repository of the Academy's Library (Library of the Hungarian Academy of Sciences) (acceptedVersion)
- arXiv (Cornell University) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- ELTE Digital Institutional Repository (EDIT) (Eötvös Loránd University) (submittedVersion, other-oa)
- arXiv (Cornell University)
- Funders
- Novo Nordisk (NNF15OC0016584)
- Novo Nordisk Fonden (NNF15OC0016584)
- Nemzeti Kutatási, Fejlesztési és Innovaciós Alap (FIEK_16-1-2016-0005)
- Topics
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Keywords
- computer-aided detection, mammography, breast lesion classification, Faster R-CNN, object detection, convolutional neural networks, breast cancer screening, INbreast dataset, DREAM challenge
- MeSH terms
- Data Accuracy, Machine Learning, Deep Learning, Breast Neoplasms, Diagnosis, Computer-Assisted, Female, Humans, Mammography, Mass Screening, ROC Curve, Databases, Factual, Neural Networks, Computer, Early Detection of Cancer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.