Optical Co-registration of MRI and On-scalp MEG
Open accessPublished version of a preprint
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
To estimate the neural generators of magnetoencephalographic (MEG) signals, MEG data have to be co-registered with an anatomical image, typically an MR image. Optically-pumped magnetometers (OPMs) enable the construction of on-scalp MEG systems providing higher sensitivity and spatial resolution than conventional SQUID-based MEG systems. We present a co-registration method that can be applied to on-scalp MEG systems, regardless of the number of sensors. We apply a structured-light scanner to create a surface mesh of the subject’s head and the sensor array, which we fit to the MR image. We quantified the reproducibility of the mesh and localised current dipoles with a phantom. Additionally, we measured somatosensory evoked fields (SEFs) to median nerve stimulation and compared the dipole positions between on-scalp and SQUID-based systems. The scanner reproduced the head surface with <1 mm error. Phantom dipoles were localised with 2.1 mm mean error. SEF dipoles corresponding to the P35m response for OPMs were well localised to the somatosensory cortex, while SQUID dipoles for two subjects were erroneously localised to the motor cortex. The developed co-registration method is inexpensive, fast and can easily be applied to on-scalp MEG. It is more convenient than traditional co-registration methods while also being more accurate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The OPMs were mounted inside 3D-printed, rigid helmets which allow co-registration of OPM positions and orientations to anatomical MRIs of the participants’ heads [40,46,47]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [47]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910 · cited 2×
“Using the mkheadsurf tool included in the FreeSurfer software package [10]–[12], a corresponding scalp surface mesh is extracted from the structural MR image.”
MethodFischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.021 · Cited by 9,526 · cited 2×
“Using the mkheadsurf tool included in the FreeSurfer software package [10]–[12], a corresponding scalp surface mesh is extracted from the structural MR image.”
MethodCortical Surface-Based Analysis
Fischl, B., Sereno, M. I., & Dale, A. M. (1999) · NeuroImage · doi:10.1006/nimg.1998.0396 · Cited by 6,147 · cited 1×
“The FreeSurfer software package [10], [12], [16] was used for pre-processing the MRI and for segmentation of the cortical surfaces.”
MethodHämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
A hybrid approach to the skull stripping problem in MRI
Ségonne, F., Dale, A. M., Busa, E., Glessner, M., Salat, D., Hahn, H. K., & Fischl, B. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.032 · Cited by 2,212 · cited 1×
“The skull and scalp surfaces were segmented using the watershed approach [17] implemented in FreeSurfer and MNE software [18].”
MNE software for processing MEG and EEG data
Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.027 · Cited by 1,951 · cited 2×
“All analysis was performed using MNE-Python software [18].”
MethodSelf-citationBudker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Spatiotemporal signal space separation method for rejecting nearby interference in MEG measurements
Taulu, S., & Simola, J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/7/008 · Cited by 1,549
Prioritizing spatial accuracy in high-resolution fMRI data using multivariate feature weight mapping
Stelzer, J., Buschmann, T., Lohmann, G., Margulies, D. S., Trampel, R., & Turner, R. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00066 · Cited by 634
Measuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296 · cited 2×
“Accurate co-registration is particularly important in on-scalp MEG [7] due to its high spatial resolution [2], [3].”
BackgroundSelf-citation
Cited by
Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285
“registration of OPM sensor locations to brain anatomy (Hom€ olle and Oostenveld, 2019; Zetter et al., 2019).”
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
Can EEG and MEG detect signals from the human cerebellum?
Andersen, L. M., Jerbi, K., & Dalal, S. S. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116817 · Cited by 142
Measuring functional connectivity with wearable MEG
Boto, E., Hill, R. M., Rea, M., Holmes, N., Seedat, Z. A., Leggett, J., Shah, V., Osborne, J., Bowtell, R., & Brookes, M. J. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117815 · Cited by 132
“This was provided by a 3-dimensional optical imaging system (structure IO camera (Occipital Inc., San Francisco, CA, USA) coupled to an Apple iPad, operating with Skanect Pro software) and an anatomical MRI scan (Hill et al., 2020; Homölle and Oostenveld, 2019; Zetter et al., 2019).”
Towards OPM-MEG in a Virtual Reality Environment
Roberts, G., Holmes, N., Alexander, N., Boto, E., Leggett, J., Hill, R. M., Shah, V., Rea, M., Vaughan, R., Maguire, E. A., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.010 · Cited by 128
“A requirement of beamforming is that one needs accurate knowledge of the sensor locations relative to brain anatomy; here this was provided using a procedure described in Zetter et al. (2019).”
MethodDecoding Imagined and Spoken Phrases From Non-invasive Neural (MEG) Signals
Dash, D., Ferrari, P., & Wang, J. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00290 · Cited by 124
“Encouraging recent work on wearable, OPMbased MEG systems (Boto et al., 2018; Roberts et al., 2019; Zetter et al., 2019) has shown that it is possible to build”
BackgroundA 90-Channel Triaxial Magnetoencephalography System Using Optically Pumped Magnetometers
Rea, M., Boto, E., Holmes, N., Hill, R., Osborne, J., Rhodes, N., Leggett, J., Rier, L., Bowtell, R., Shah, V., et al. (2022) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14890 · Cited by 102
Potential of on‐scalp MEG: Robust detection of human visual gamma‐band responses
Iivanainen, J., Zetter, R., & Parkkonen, L. (2020) · Human Brain Mapping · doi:10.1002/hbm.24795 · Cited by 99
“MEG–MRI co-registration was performed using an optical scanner as described by Zetter et al. (2019);an example of co-registered OPM positions with respect to the subject’s head is shown in Fig.”
Self-citationHolmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., Boto, E., Tierney, T. M., Rier, L., Rivero, G. R., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120157 · Cited by 89
“Here, co-registration of the sensor positions to an anatomical MRI of the participant was achieved using optical methods (Hill et al., 2020; Zetter et al., 2019).”
Measurement of Frontal Midline Theta Oscillations using OPM-MEG
Rhodes, N., Rea, M., Boto, E., Rier, L., Shah, V., Hill, R. M., Osborne, J., Doyle, C., Holmes, N., Coleman, S. C., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120024 · Cited by 94
How far have we explored fungi to fight cancer?
How, C. W., Ong, Y. S., Low, S. S., Pandey, A., Show, P. L., & Foo, J. B. (2021) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2021.03.009 · Cited by 87
Homölle, S., & Oostenveld, R. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108378 · Cited by 65
“Specifically, it might be useful for the OPM-based on-scalp MEG recordings which comprise magnetic field sensors that are mounted on the head in a very similar way as EEG electrodes (Boto et al., 2018; Zetter et al., 2019), or to record the position of NIRS optodes (Piper et al., 2014).”
BackgroundNaturalistic Hyperscanning with Wearable Magnetoencephalography
Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Rhodes, N., Shah, V., Osborne, J., Fromhold, T. M., et al. (2023) · Sensors · doi:10.3390/s23125454 · Cited by 52
“The OPMs were mounted inside 3D-printed, rigid helmets which allow co-registration of OPM positions and orientations to anatomical MRIs of the participants’ heads [40,46,47] (whole-head MRI scans were generated using a 3 T Philips Ingenia system, running an MPRAGE sequence, at an isotropic spatial resolution of 1 mm).”
MethodPragmatic spatial sampling for wearable MEG arrays
Tierney, T. M., Mellor, S., O’Neill, G. C., Holmes, N., Boto, E., Roberts, G., Hill, R. M., Leggett, J., Bowtell, R., Brookes, M. J., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-77589-8 · Cited by 48
Co-registration Comparison of On-Scalp Magnetoencephalography and Magnetic Resonance Imaging
Cao, F., An, N., Xu, W., Wang, W., Yang, Y., Xiang, M., Gao, Y., & Ning, X. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.706785 · Cited by 50
Rier, L., Rhodes, N., Pakenham, D. O., Boto, E., Holmes, N., Hill, R. M., Rivero, G. R., Shah, V., Doyle, C., Osborne, J., et al. (2024) · eLife · doi:10.7554/elife.94561 · Cited by 58
Schofield, H., Hill, R. M., Feys, O., Holmes, N., Osborne, J., Doyle, C., Bobela, D., Corvilain, P., Wens, V., Rier, L., et al. (2024) · Imaging Neuroscience · doi:10.1162/imag_a_00283 · Cited by 63
MEG Sensor Selection for Neural Speech Decoding
Dash, D., Wisler, A., Ferrari, P., Davenport, E. M., Maldjian, J., & Wang, J. (2020) · IEEE Access · doi:10.1109/access.2020.3028831 · Cited by 37
“With the new era of OPM-MEG developments [47], [50], establishing the optimal placement of a few sensors with improved decoding performance may have a substantial impact on the feasibility of speech-BCIs.”
BackgroundAn, N., Cao, F., Wen, L., Wang, W., Xu, W., Wang, C., Xiang, M., Gao, Y., Sui, B., Liang, A., et al. (2022) · iScience · doi:10.1016/j.isci.2022.103752 · Cited by 40
“1 ll OPEN ACCESS (Hill et al., 2020), sensor array design (Beltrachini et al., 2021), co-registration with MRI (Zetter et al., 2019; Cao et al., 2021), and applications (Iivanainen et al., 2020; Boto et al., 2021; Wittevrongel et al., 2021).”
BackgroundOptical Co-Registration Method of Triaxial OPM-MEG and MRI
Cao, F., An, N., Xu, W., Wang, W., Li, W., Wang, C., Xiang, M., Gao, Y., & Ning, X. (2023) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2023.3263167 · Cited by 32
“co-registration methods for rigid helmets [19], [20], [21], [22].”
ResultTest-retest reliability of the human connectome: An OPM-MEG study
Rier, L., Michelmann, S., Ritz, H., Shah, V., Hill, R. M., Osborne, J., Doyle, C., Holmes, N., Bowtell, R. W., Brookes, M. J., et al. (2023) · Imaging Neuroscience · doi:10.1162/imag_a_00020 · Cited by 36
Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils
Iivanainen, J., Borna, A., Zetter, R., Carter, T. R., Stephen, J. M., McKay, J., Parkkonen, L. T., Taulu, S., & Schwindt, P. D. D. (2022) · Sensors · doi:10.3390/s22083059 · Cited by 49
“, [11]), with new requirements that must be taken into account.”
BackgroundMethodInfluentialSelf-citationDetection and analysis of MEG signals in occipital region with double-channel OPM sensors
Zhang, X., Chen, C.-Q., Zhang, M., Ma, C., Zhang, Y., Wang, H., Guo, Q., Hu, T., Liu, Z., Chang, Y., et al. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108948 · Cited by 29
Høgsted, E. S., Borgsted, C., Dam, V. H., Nasser, A., Jørgensen, N. R., Ozenne, B., Stenbæk, D. S., & Frøkjær, V. G. (2021) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.731994 · Cited by 28
Pushing the boundaries of MEG based on optically pumped magnetometers towards early human life
Corvilain, P., Wens, V., Bourguignon, M., Capparini, C., Fourdin, L., Ferez, M., Feys, O., Tiège, X. D., & Bertels, J. (2025) · Imaging Neuroscience · doi:10.1162/imag_a_00489 · Cited by 35
Data‐driven model optimization for optically pumped magnetometer sensor arrays
Duque‐Muñoz, L., Tierney, T. M., Meyer, S. S., Boto, E., Holmes, N., Roberts, G., Leggett, J., Vargas‐Bonilla, J. F., Bowtell, R. W., Brookes, M. J., et al. (2019) · Human Brain Mapping · doi:10.1002/hbm.24707 · Cited by 25
Noninvasive muscle activity imaging using magnetography
Llinás, R. R., Ustinin, M. N., Rykunov, S. D., Walton, K. D., Rabello, G. M., Garcia, J., Boyko, A. I., & Sychev, V. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1913135117 · Cited by 24
“This particular combination requires the use of mathematical modeling for coregistration and thus improvement has been of recent interest and relevance (2, 3).”
BackgroundOMMR: Co-registration toolbox of OPM-MEG and MRI
Cao, F., An, N., Xu, W., Wang, W., Li, W., Wang, C., Yang, Y., Xiang, M., Gao, Y., & Ning, X. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.984036 · Cited by 28
“, 2022), structured-light scanners (Zetter et al., 2019; Hill et al., 2020), and laser scanners (Hironaga et al.”
BackgroundAutomatic coregistration of MRI and on-scalp MEG
Gu, W., Ru, X., Li, D., He, K., Cui, Y., Sheng, J., & Gao, J. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109181 · Cited by 26
Feys, O., Wens, V., Depondt, C., Rikir, E., Gaspard, N., Paesschen, W. V., Aeby, A., Bodart, O., Carrette, E., Holmes, N., et al. (2025) · Epilepsia · doi:10.1111/epi.18439 · Cited by 25
Automatic co-registration of OPM-MEG and MRI using a 3D laser scanner
Gao, Z., Cao, F., An, N., & Ning, X. (2023) · Measurement · doi:10.1016/j.measurement.2023.113729 · Cited by 22
Co-registration of OPM-MCG signals with CT using optical scanning
Yang, Y., Wang, H., Liu, Z., Wang, Y., Han, X., Jia, Y., Pang, J., Xie, F., Yu, D., Zhang, Y., et al. (2023) · iScience · doi:10.1016/j.isci.2023.108235 · Cited by 20
“Ten scans of the phantom model were conducted to calculate the reproducibility error of 0.21 G 0.02 mm, which is better than the reproducibility error reported by Zetter et al. in OPM sensor MEG registration, 19 thus proving the stability of this experimental method in OPM-MCG registration.”
MethodInfluentialSpatial accuracy evaluation of magnetic source imaging methods on OPM-based MEG
An, N., Cao, F., Li, W., Wang, W., Xu, W., Wang, C., Xiang, M., Gao, Y., Sui, B., Wang, D., et al. (2022) · iScience · doi:10.1016/j.isci.2022.105177 · Cited by 19
“The center of the reconstructed sources was near the postcentral gyrus, consistent with previous findings (Zetter et al., 2019; Hari and Puce, 2017; Backes et al., 2000).”
Iwata, G. Z., Hu, Y., Wickenbrock, A., Sander, T. H., Muthuraman, M., Chirumamilla, V. C., Groppa, S., Liu, Q., & Budker, D. (2022) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2021-0019 · Cited by 22
Methods for Improving Movement Compatibility of Wearable OPM-MEG: A Review
Wang, C., Cao, F., Wang, W., Xu, W., Li, W., Gao, Z., & An, N. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3329043 · Cited by 17
“With the increasing number of sensors in OPM-MEG systems, optical surface scanning can be used combined with HPI coils for reliable real-time head-movement tracking [75].”
MethodHironaga, N., Takei, Y., Mitsudo, T., Kimura, T., & Hirano, Y. (2020) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2020.00863 · Cited by 20
“When using wearable-type sensors, MEG-MRI coregistration is crucial because of non-fixed flexible sensor locations and orientations, but some proposals have been made for the use of OPM with 3D printers or 3D-structured light scanners (21, 22, 77).”
MethodComparison Between Conventional SQUID Based and Novel OPM Based Measuring Systems in MEG
Marhl, U., Jodko-Władzińska, A., Brühl, R., Sander, T. H., & Jazbinšek, V. (2020) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-64610-3_30 · Cited by 15
On electromagnetic head digitization in MEG and EEG
Jaiswal, A. K., Nenonen, J., & Parkkonen, L. T. (2023) · Scientific Reports · doi:10.1038/s41598-023-30223-9 · Cited by 11
Self-citationVandewouw, M. M., Sato, J., Safar, K., Rhodes, N., & Taylor, M. J. (2024) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2024.101433 · Cited by 14
“The participants ’ head digitisations collected during data acquisition and surface meshes of the age-appropriate templates were used to co-register the head models and source positions to the OPM data (R. M. Hill et al., 2020; Rhodes et al., 2023; Zetter et al., 2019).”
MethodAutomatic Sensor Array Calibration and Coregistration for On-Scalp MEG
Pang, M., Huang, Z., Ding, Z., & Han, B. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3277096 · Cited by 10
Rhodes, N., Rier, L., Boto, E., Hill, R. M., & Brookes, M. J. (2025) · Imaging Neuroscience · doi:10.1162/imag.a.8 · Cited by 15
Schneiderman, J. F., Ruffieux, S., Pfeiffer, C., & Riaz, B. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_78 · Cited by 12
Felix, S. N., Agondi, R. C., Aun, M. V., Olivo, C. R., de Almeida, F. M., Amorim, T. S., Cezario, J. C., Junior, P. F. G.-B., Tibério, I. D. F. L. C., Martins, M. A., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-97846-8 · Cited by 11
Optical pump magnetometers parametric correction method based on three-axis coil arrays
Liang, S., Zhu, Y., He, J., Qi, J., Jia, Y., Wang, A., Zhao, T., Wei, C., Jiao, H., Feng, L., et al. (2024) · Measurement · doi:10.1016/j.measurement.2024.115909 · Cited by 10
Real-Time Localization of OPMs in a Flexible Array During MEG Recordings
Gu, W., He, K., Ma, X., Li, D., Pang, W., Sheng, J., & Gao, J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3346516 · Cited by 9
“Several previous studies have relied on manually measuring the insertion depth of each OPM to localize it inside the rigid helmet [22], [23].”
BackgroundMethodHeininen, J., Julku, U. H., Myöhänen, T. T., Kotiaho, T., & Kostiainen, R. K. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462537 · Cited by 8
Co-Registration Error Analysis and Array Calibration for OPM-MEG System
Pang, M., Huang, Z., Ding, Z., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3216411 · Cited by 13
Helbling, S. (2025) · Imaging Neuroscience · doi:10.1162/imag_a_00410 · Cited by 9
MRI free targeting of deep brain structures based on facial landmarks
Riis, T. S., Lunt, S., & Kubanek, J. (2025) · Brain stimulation · doi:10.1016/j.brs.2024.12.1478 · Cited by 9
OPM-MEG reveals dynamics of beta bursts underlying attentional processes in sensory cortex
Rivero, G., Tanner, Z., Rier, L., Hill, R. M., Shah, V., Rea, M., Doyle, C., Osborne, J., Bobela, D., Morris, P. G., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-08037-8 · Cited by 8
Węgiel, A., Zielińska, N., Tubbs, R. S., & Olewnik, Ł. H. (2021) · Clinical Anatomy · doi:10.1002/ca.23798 · Cited by 7
Fertility Issues in Polycystic Ovarian Disease
Rushing, J. S., & Santoro, N. F. (2021) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2020.10.004 · Cited by 7
Measuring Human Auditory Evoked Fields with a Flexible Multi-Channel OPM-Based MEG System
Zhang, X., Chang, Y. H., Wang, H., Zhang, Y., Hu, T., Feng, X., Zhang, M., Yao, Z.-K., Chen, C.-Q., Xu, J.-Y., et al. (2024) · Journal of Integrative Neuroscience · doi:10.31083/j.jin2305093 · Cited by 7
“Such restrictions not only limit the scope of experiments [1–3], but also make them unsuitable for children, babies and subjects with reduced mobility.”
BackgroundMethodPseudo‐ MRI Engine for MRI ‐Free Electromagnetic Source Imaging
Jaiswal, A. K., Nenonen, J., & Parkkonen, L. T. (2025) · Human Brain Mapping · doi:10.1002/hbm.70148 · Cited by 7
“In contrast, extremely dense digitization points (> 500 points), such as those obtained by an optical scanner (Homölle and Oostenveld 2019; Zetter, Iivanainen, and Parkkonen 2019), prolong the warping procedure (see Table S1).”
Self-citationGao, Z., Liu, W., Wu, C., Zhang, Z., Gao, J., Shao, M., Yang, J., Li, W., Wang, W., Wang, C., et al. (2025) · Optics & Laser Technology · doi:10.1016/j.optlastec.2025.113063 · Cited by 4
Two neuropeptides that promote blood feeding in Anopheles stephensi mosquitoes
Bansal, P., Pillai, R., Pooja, D. B., & Sen, S. (2026) · eLife · doi:10.7554/elife.108625.4 · Cited by 4
Tanner, Z., Rier, L., Fildes, J., Rivero, G., Schofield, H., Marani, C., Holmes, N., Hill, R. M., Shah, V., Doyle, C., et al. (2025) · Imaging Neuroscience · doi:10.1162/imag.a.10 · Cited by 10
“By combining these coordinate transformations, it was possible to co-register the sensor locations and orientations to brain anatomy in the MRI ( Hill et al., 2020; Zetter et al., 2019).”
Vulnerability of island insect pollinator communities to pathogens
Brettell, L. E., Martin, S. J., Riegler, M., & Cook, J. M. (2021) · Journal of Invertebrate Pathology · doi:10.1016/j.jip.2021.107670 · Cited by 4
Fu, X., Yang, Y., Cao, Y., Han, Q., Guo, X. Q. T. Z. W., Xu, Y., & Ning, X. (2025) · Information Fusion · doi:10.1016/j.inffus.2025.103161 · Cited by 3
Optical co-registration method of OPM-MCG and MRI based on skin markers
He, J., Yang, S., Jia, Y., Liang, S., Zhu, Y., Qi, J., Shang, S., Wang, A., Zhao, T., Wei, C., et al. (2025) · Measurement · doi:10.1016/j.measurement.2025.118319 · Cited by 4
Global sensitivity of MEG source analysis to tissue conductivity uncertainties
Vorwerk, J., Höltershinken, M. B., Wolters, C. H., & Baumgarten, D. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121618 · Cited by 7
Gu, W., Li, D., & Gao, J. (2023) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2023.110010 · Cited by 4
Schneiderman, J. F., Ruffieux, S., Pfeiffer, C., & Riaz, B. (2019) · Springer eBooks · doi:10.1007/978-3-319-62657-4_78-1 · Cited by 4
Hillebrand, A., Holmes, N., Sijsma, N., O’Neill, G. C., Tierney, T. M., Liberton, N. P. T. J., Stam, A. H., van Klink, N. E. C., Stam, C. J., Bowtell, R. W., et al. (2022) · medRxiv · doi:10.1101/2022.11.03.22281836 · Cited by 3
“A compromise may be the use of a limited 731 number of different-sized rigid helmets, with holders in which OPMs can be pressed 732 onto the scalp (Zetter et al., 2019).”
BackgroundThe neurodevelopmental trajectory of beta band oscillations: an OPM-MEG studyPreprint
Rier, L., Rhodes, N., Pakenham, D., Boto, E., Holmes, N., Hill, R. M., Rivero, G. R., Shah, V., Doyle, C., Osborne, J., et al. (2024) · eLife · doi:10.7554/elife.94561.1 · Cited by 8
Xu, W., Wang, W., Cao, F., An, N., Li, W., Xiang, M., Ning, X., Liu, Y., & Wang, B. (2025) · Bioengineering · doi:10.3390/bioengineering12111198 · Cited by 3
“Early implementations typically employed head position indicator (HPI) coils combined with an electromagnetic tracking system (e.g., Polhemus Fastrak), where HPI coils were placed at anatomical landmarks to establish a reference coordinate system [23,24].”
Electroanatomical mapping of the stomach with simultaneous biomagnetic measurements
Drake, C. E., Cheng, L. K., Muszynski, N. D., Somarajan, S., Paskaranandavadivel, N., Angeli, T. R., Du, P., Bradshaw, L. A., & Avci, R. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.107384 · Cited by 2
Anatomically Veridical On‐Scalp Sensor Topographies
Alexander, N., Medrano, J., Seymour, R. A., Mellor, S., O’Neill, G. C., Spedden, M. E., Tierney, T. M., & Maguire, E. A. (2025) · European Journal of Neuroscience · doi:10.1111/ejn.70060 · Cited by 2
“OPMs combined with optical coregistration (Zetter, Iivanainen, and Parkkonen 2019) have also been used to scan larger cohorts (Rhodes et al. 2023).”
Skidchenko, E., Butorina, A. V., Fedosov, N., Shevtsov, O., Medvedeva, D., Zhao, D. G., Dubynin, I. A., Fedorov, M. V., Koshev, N., & Ossadtchi, A. E. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3554317 · Cited by 4
“In general, both SQUID system’s dry phantom, which is often used during MEG system’s maintenance, and a specially designed reference phantom can be employed for this purpose, see, for example [46] and [52], respectively.”
Adachi, Y., Oyama, D., & Uehara, G. (2019) · IEEE Magnetics Letters · doi:10.1109/lmag.2019.2943128 · Cited by 3
The neurodevelopmental trajectory of beta band oscillations: an OPM-MEG studyPreprint
Rier, L., Rhodes, N., Pakenham, D., Boto, E., Holmes, N., Hill, R. M., Rivero, G., Shah, V., Doyle, C., Osborne, J., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.01.04.573933 · Cited by 2
“Sensor locations and orientations relative to this anatomy were found by aligning it to the digitisation of the participant wearing the sensor helmet, and adding the known geometry of the sensor locations and orientations within the helmet 61 – 63 .”
MethodHigh-efficiency co-registration of OPM-MEG and MRI using point cloud processing
Qi, J., Shang, S., Chen, K., He, J., Yang, S., Wang, A., Wei, C., Zhao, T., Jiao, H., Feng, L., et al. (2025) · Optics Express · doi:10.1364/oe.553202 · Cited by 2
Automatic Optical Co-Registration Method of OPM-MCG and CT
Liu, Z., Yang, Y., Wang, R., Wang, Y., Pang, J., Liu, G., & Xiang, M. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3574909 · Cited by 1
“With the rapid development of optical devices, optical scanning methods are widely applied in bioelectromagnetic registration [15], [16], [17].”
Adaptive helmet design for optically pumped magnetometry
Hristova, I., Funk, F., van Schaik, B., Clercx, F., Ooms, A., Bosma, H., Sabater, D. Z., Nonnekes, A., Wang, P., & Hillebrand, A. (2025) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2025.100949 · Cited by 1
Fu, X., Yang, Y., Wang, R., Cao, Y., Ma, Y., & Ning, X. (2026) · Medical Image Analysis · doi:10.1016/j.media.2026.104084 · Cited by 1
Supine OPM-MEG in Multilayer Cylindrical Shield
Sheng, J., Li, D., Wan, S., Qin, J., & Gao, J. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_4 · Cited by 1
Turning OPM-MEG into a Wearable Technology
Rhodes, N., Holmes, N., Hill, R. M., Barnes, G. R., Bowtell, R. W., Brookes, M. J., & Boto, E. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_11 · Cited by 4
Magnetoresistance-based Biosensors
Sharma, A., Chougale, A. D., Salvan, G., & Patil, P. B. (2021) · Royal Society of Chemistry eBooks · doi:10.1039/9781839162756-00369 · Cited by 3
Niranjan, V., Lavanya, C., Pooja, H. V., Bhat, S. S., & Kulkarni, S. R. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.05.12.593770 · Cited by 1
Signal space beamforming for gain- and geometry-independent interference suppression in wearable MEGPreprint
Ferez, M., Corvilain, P., Feys, O., Capparini, C., Fourdin, L., Bertels, J., Tiège, X. D., & Wens, V. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.01.22.700798 · Cited by 1
Practicalities of Data Collection
Hari, R., & Puce, A. (2023) · Oxford University Press eBooks · doi:10.1093/med/9780197542187.003.0007
Hari, R., & Puce, A. (2023) · Oxford University Press eBooks · doi:10.1093/med/9780197542187.003.0010
The neurodevelopmental trajectory of beta band oscillations: an OPM-MEG studyPreprint
Rier, L., Rhodes, N., Pakenham, D., Boto, E., Holmes, N., Hill, R. M., Rivero, G., Shah, V., Doyle, C., Osborne, J., et al. (2024) · eLife · doi:10.7554/elife.94561.2 · Cited by 2
Myelin-informed forward models for M/EEG source reconstructionPreprint
Helbling, S., Meyer, S. S., & Weiskopf, N. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.06.30.601378
“In cryogenic MEG using subject-specific headcasts can provide the necessary co-registration accuracy 49,50 , while the use of rigid helmets 62 combined with high-accuracy optical scanning devices are expected to provide sufficient co-registration accuracy in OPM-MEG systems 63,64 .”
MethodRhodes, N., Bandhan, J., Vandewouw, M. M., Coleman, S. C., & Taylor, M. J. (2025) · Scientific Reports · doi:10.1038/s41598-025-12131-2 · Cited by 2
“A 3D model of the participant’s head, with the helmet on, was obtained using an Einscan H 3D-scanner (Shining 3D, Hangzhou, China) to determine the position of the OPM sensors relative to the head 5,38 .”
Lee, Y. S., & Woo, S. H. (2025) · Medical Lasers · doi:10.25289/ml.25.034
Yan, B., Ji, J., Peng, Y., Cao, Y., Zhang, H., Zhang, Y., Zhang, Y., Niu, Y., Sun, C., & Ding, M. (2026) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2026.05.001
A Pose Calibration Method for Sensors in OPM-MEG Systems With Experimental Validation
Dai, X., Pan, D., Li, K., Jin, C., Chen, Y., & Li, L. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3709494
“In addition to the aforementioned methods, optical scanning techniques are also employed for sensor calibration in OPM-MEG [20], [21].”
Xu, Y., Fu, X., Han, Q., Ma, W., Liu, K., Wang, Z., & Ning, X. (2026) · IEEE Data Driven Control and Learning Systems Conference (DDCLS) · doi:10.1109/ddcls71227.2026.11610132
“Current alignment methods primarily rely on optical scanning devices to capture 3D point cloud data of the head or device surface, followed by coordinate alignment via geometric fitting algorithms [4] .”
Modular Arrays for High Precision Wearable MEGPreprint
Alexander, N., Mariola, A., Puvvada, S., Bezsudnova, Y., Tierney, T. M., Barnes, G. R., & Callaghan, M. F. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.08.19.745485
“A plethora of methods are available to researchers for co-registration, typically involving spatial imaging of the head with and without the sensors, along with building a model of sensor array geometry, and finally aligning the two (Cao et al., 2023; Rhodes et al., 2023; Zetter et al., 2019).”
Rehbein, M. A., Kroker, T., Wollbrink, A., & Junghoefer, M. (2026) · Neuromethods · doi:10.1007/978-1-0716-5340-1_6
Metadata
- Authors
- Zetter, R., Iivanainen, J., & Parkkonen, L.
- Affiliations
- Aalto University (FI)
- Corresponding author
- Zetter, Rasmus
- Venue
- Scientific Reports
- Published
- 2019-04-02
- Volume
- 9
- Issue
- 1
- Pages
- 5490-5490
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC6445124
- OpenAlex
- W2904035998
- Cited by
- 93
- References
- 33
- Citations by year
- 2026: 8 · 2025: 19 · 2024: 12 · 2023: 15 · 2022: 10 · 2021: 11 · 2020: 10 · 2019: 8
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Aaltodoc (Aalto University) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Aalto-Yliopisto
- Instrumentariumin Tiedesäätiö (180043)
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (R01NS094604)
- H2020 European Research Council (678578)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- optically pumped magnetometers, structured light scanning, somatosensory evoked fields, median nerve stimulation
- MeSH terms
- Adult, Evoked Potentials, Somatosensory, Humans, Magnetic Resonance Imaging, Male, Scalp, Magnetoencephalography, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.