Optical Co-registration of MRI and On-scalp MEG
Open accessPublished version of a preprint
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
To estimate the neural generators of magnetoencephalographic (MEG) signals, MEG data have to be co-registered with an anatomical image, typically an MR image. Optically-pumped magnetometers (OPMs) enable the construction of on-scalp MEG systems providing higher sensitivity and spatial resolution than conventional SQUID-based MEG systems. We present a co-registration method that can be applied to on-scalp MEG systems, regardless of the number of sensors. We apply a structured-light scanner to create a surface mesh of the subject’s head and the sensor array, which we fit to the MR image. We quantified the reproducibility of the mesh and localised current dipoles with a phantom. Additionally, we measured somatosensory evoked fields (SEFs) to median nerve stimulation and compared the dipole positions between on-scalp and SQUID-based systems. The scanner reproduced the head surface with <1 mm error. Phantom dipoles were localised with 2.1 mm mean error. SEF dipoles corresponding to the P35m response for OPMs were well localised to the somatosensory cortex, while SQUID dipoles for two subjects were erroneously localised to the motor cortex. The developed co-registration method is inexpensive, fast and can easily be applied to on-scalp MEG. It is more convenient than traditional co-registration methods while also being more accurate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The OPMs were mounted inside 3D-printed, rigid helmets which allow co-registration of OPM positions and orientations to anatomical MRIs of the participants’ heads [40,46,47]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [47]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910 · cited 2×
“Using the mkheadsurf tool included in the FreeSurfer software package [10]–[12], a corresponding scalp surface mesh is extracted from the structural MR image.”
MethodFischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.021 · Cited by 9,526 · cited 2×
“Using the mkheadsurf tool included in the FreeSurfer software package [10]–[12], a corresponding scalp surface mesh is extracted from the structural MR image.”
MethodCortical Surface-Based Analysis
Fischl, B., Sereno, M. I., & Dale, A. M. (1999) · NeuroImage · doi:10.1006/nimg.1998.0396 · Cited by 6,147 · cited 1×
“The FreeSurfer software package [10], [12], [16] was used for pre-processing the MRI and for segmentation of the cortical surfaces.”
MethodHämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
A hybrid approach to the skull stripping problem in MRI
Ségonne, F., Dale, A. M., Busa, E., Glessner, M., Salat, D., Hahn, H. K., & Fischl, B. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.032 · Cited by 2,212 · cited 1×
“The skull and scalp surfaces were segmented using the watershed approach [17] implemented in FreeSurfer and MNE software [18].”
MNE software for processing MEG and EEG data
Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.027 · Cited by 1,951 · cited 2×
“All analysis was performed using MNE-Python software [18].”
MethodSelf-citationBudker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Spatiotemporal signal space separation method for rejecting nearby interference in MEG measurements
Taulu, S., & Simola, J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/7/008 · Cited by 1,549
Prioritizing spatial accuracy in high-resolution fMRI data using multivariate feature weight mapping
Stelzer, J., Buschmann, T., Lohmann, G., Margulies, D. S., Trampel, R., & Turner, R. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00066 · Cited by 634
Measuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296 · cited 2×
“Accurate co-registration is particularly important in on-scalp MEG [7] due to its high spatial resolution [2], [3].”
BackgroundSelf-citation(2013) · doi:10.1017/cbo9780511846380 · Cited by 286
On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K., & Parkkonen, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.022 · Cited by 269
Self-citationOn the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study
Boto, E., Bowtell, R., Krüger, P., Fromhold, T. M., Morris, P. G., Meyer, S. S., Barnes, G. R., & Brookes, M. J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0157655 · Cited by 194 · cited 2×
“Accurate co-registration is particularly important in on-scalp MEG [7] due to its high spatial resolution [2], [3].”
BackgroundGeodesic photogrammetry for localizing sensor positions in dense-array EEG
Russell, G. S., Eriksen, K. J., Poolman, P., Luu, P., & Tucker, D. M. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.12.022 · Cited by 117 · cited 1×
“In earlier EEG work, automated algorithms [13], [27], colored markers [28] or even timed LEDs [29] have successfully been used to solve this problem.”
MethodAdjamian, P., Barnes, G. R., Hillebrand, A., Holliday, I. E., Singh, K. D., Furlong, P. L., Harrington, E., Barclay, C. W., & Route, P. J. G. (2003) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.10.023 · Cited by 99 · cited 1×
“reliable source estimation as shown in several studies concerning conventional SQUID-based MEG [19], [20], EEG [21], [22] and more recently also on-scalp MEG [7].”
Balzamo, E., Marquis, P., Chauvel, P., & Régis, J. M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.02.012 · Cited by 77
Dalal, S. S., Rampp, S., Willomitzer, F., & Ettl, S. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00042 · Cited by 75 · cited 4×
“In earlier EEG work, automated algorithms [13], [27], colored markers [28] or even timed LEDs [29] have successfully been used to solve this problem.”
BackgroundInfluentialA rapid method for determining standard 10/10 electrode positions for high resolution EEG studies
Le, J., Lu, M., Pellouchoud, E., & Gevins, A. S. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00004-2 · Cited by 70 · cited 1×
“In practice, the reported accuracy of Polhemus-based co-registration ranges from 3 to 7 mm [14], [15], [24], [26].”
Öisjöen, F., Schneiderman, J. F., Figueras, G. A., Chukharkin, M. L., Kalabukhov, A., Hedström, A., Elam, M., & Winkler, D. (2012) · Applied Physics Letters · doi:10.1063/1.3698152 · Cited by 70
Spatial mislocalization of EEG electrodes – effects on accuracy of dipole estimation
Khosla, D., Don, M., & Kwong, B. (1999) · Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00121-7 · Cited by 66 · cited 1×
“reliable source estimation as shown in several studies concerning conventional SQUID-based MEG [19], [20], EEG [21], [22] and more recently also on-scalp MEG [7].”
BackgroundEEG–MRI Co-registration and Sensor Labeling Using a 3D Laser Scanner
Koessler, L., Cecchin, T., Caspary, O., Benhadid, A., Vespignani, H., & Maillard, L. G. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0230-0 · Cited by 59
Requirements for Coregistration Accuracy in On-Scalp MEG
Zetter, R., Iivanainen, J., Stenroos, M., & Parkkonen, L. (2018) · Brain Topography · doi:10.1007/s10548-018-0656-5 · Cited by 56 · cited 2×
“Accurate co-registration is particularly important in on-scalp MEG [7] due to its high spatial resolution [2], [3].”
BackgroundSelf-citationSingle Camera Photogrammetry System for EEG Electrode Identification and Localization
Baysal, U., & Şengül, G. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9950-4 · Cited by 36 · cited 1×
“In practice, the reported accuracy of Polhemus-based co-registration ranges from 3 to 7 mm [14], [15], [24], [26].”
Proposal for a new MEG–MRI co-registration: A 3D laser scanner system
Hironaga, N., Hagiwara, K., Ogata, K., Hayamizu, M., Urakawa, T., & Tobimatsu, S. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.03.029 · Cited by 36 · cited 10×
“Similar methods applied to SQUID-based MEG have previously been presented by Bardouille and colleagues [14] and Murthy and colleagues [15].”
BackgroundInfluentialLocalizing on-scalp MEG sensors using an array of magnetic dipole coils
Pfeiffer, C., Andersen, L. M., Lundqvist, D., Hämäläinen, M., Schneiderman, J. F., & Oostenveld, R. (2018) · PLoS ONE · doi:10.1371/journal.pone.0191111 · Cited by 35
Improved Localization Accuracy in Magnetic Source Imaging Using a 3-D Laser Scanner
Bardouille, T., Krishnamurthy, S. V., Hajra, S. G., & D’Arcy, R. C. N. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2220356 · Cited by 32 · cited 3×
“which is similar to what has been reported earlier when applying optical co-registration to whole-head SQUID-based MEG systems [14], [15] and significantly more accurate than these studies reported for electromagnetic digitizer-based co-registration.”
BackgroundResultA Single Camera Photogrammetry System for Multi-angle Fast Localization of EEG Electrodes
Qian, S., & Yang, S. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0374-6 · Cited by 32 · cited 1×
“In earlier EEG work, automated algorithms [13], [27], colored markers [28] or even timed LEDs [29] have successfully been used to solve this problem.”
MethodFaster and improved 3-D head digitization in MEG using Kinect
Murthy, S. V. K., MacLellan, M., Beyea, S., & Bardouille, T. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00326 · Cited by 26 · cited 4×
“which is similar to what has been reported earlier when applying optical co-registration to whole-head SQUID-based MEG systems [14], [15] and significantly more accurate than these studies reported for electromagnetic digitizer-based co-registration.”
BackgroundMethodResultInfluentialMeasurement of 3D electrode coordinates by means of a 3D photogrammetric head digitizer
Bauer, H., Lamm, C., Holzreiter, S., Holländer, I., Leodolter, U., & Leodolter, M. (2000) · NeuroImage · doi:10.1016/s1053-8119(00)91392-2 · Cited by 24 · cited 1×
“In earlier EEG work, automated algorithms [13], [27], colored markers [28] or even timed LEDs [29] have successfully been used to solve this problem.”
MethodSolomon, J. P., Boe, S. G., & Bardouille, T. (2015) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2015.10.001 · Cited by 20
On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometersPreprint
Iivanainen, J., Zetter, R., Grön, M., et al. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/471391 · Cited by 13
Self-citationImproved EEG source localization employing 3D sensing by "Flying Triangulation"
Ettl, S., Rampp, S., Fouladi-Movahed, S., Dalal, S. S., Willomitzer, F., Arold, O., Stefan, H., & Häusler, G. (2013) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2020533 · Cited by 10
Bardouille, T., Power, L., Lalancette, M., Bishop, R., Beyea, S., Taylor, M. J., & Dunkley, B. T. (2018) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2018.05.018 · Cited by 8 · cited 1×
“Previous work has shown that intersession variability of P35m localization using SQUID-MEG can be ∼5 mm [30], and N20m localization between SQUID-based MEG systems can have a variability of ∼8 mm [31].”
BackgroundHigh-resolution intersubject averaging and a coordinate system for the cortical surface
Fischl, B., Sereno, M. I., Tootell, R. B. H., & Dale, A. M. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<272::aid-hbm10>3.0.co;2-4
Cited by
Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285
“registration of OPM sensor locations to brain anatomy (Hom€ olle and Oostenveld, 2019; Zetter et al., 2019).”
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
Can EEG and MEG detect signals from the human cerebellum?
Andersen, L. M., Jerbi, K., & Dalal, S. S. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116817 · Cited by 142
Measuring functional connectivity with wearable MEG
Boto, E., Hill, R. M., Rea, M., Holmes, N., Seedat, Z. A., Leggett, J., Shah, V., Osborne, J., Bowtell, R., & Brookes, M. J. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117815 · Cited by 132
“This was provided by a 3-dimensional optical imaging system (structure IO camera (Occipital Inc., San Francisco, CA, USA) coupled to an Apple iPad, operating with Skanect Pro software) and an anatomical MRI scan (Hill et al., 2020; Homölle and Oostenveld, 2019; Zetter et al., 2019).”
Metadata
- Authors
- Zetter, R., Iivanainen, J., & Parkkonen, L.
- Affiliations
- Aalto University (FI)
- Corresponding author
- Zetter, Rasmus
- Venue
- Scientific Reports
- Published
- 2019-04-02
- Volume
- 9
- Issue
- 1
- Pages
- 5490-5490
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC6445124
- OpenAlex
- W2904035998
- Cited by
- 93
- References
- 33
- Citations by year
- 2026: 8 · 2025: 19 · 2024: 12 · 2023: 15 · 2022: 10 · 2021: 11 · 2020: 10 · 2019: 8
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Aaltodoc (Aalto University) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Aalto-Yliopisto
- Instrumentariumin Tiedesäätiö (180043)
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (R01NS094604)
- H2020 European Research Council (678578)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- optically pumped magnetometers, structured light scanning, somatosensory evoked fields, median nerve stimulation
- MeSH terms
- Adult, Evoked Potentials, Somatosensory, Humans, Magnetic Resonance Imaging, Male, Scalp, Magnetoencephalography, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.