Requirements for Coregistration Accuracy in On-Scalp MEG
Open accessPublished version of a preprint
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Recent advances in magnetic sensing has made on-scalp magnetoencephalography (MEG) possible. In particular, optically-pumped magnetometers (OPMs) have reached sensitivity levels that enable their use in MEG. In contrast to the SQUID sensors used in current MEG systems, OPMs do not require cryogenic cooling and can thus be placed within millimetres from the head, enabling the construction of sensor arrays that conform to the shape of an individual's head. To properly estimate the location of neural sources within the brain, one must accurately know the position and orientation of sensors in relation to the head. With the adaptable on-scalp MEG sensor arrays, this coregistration becomes more challenging than in current SQUID-based MEG systems that use rigid sensor arrays. Here, we used simulations to quantify how accurately one needs to know the position and orientation of sensors in an on-scalp MEG system. The effects that different types of localisation errors have on forward modelling and source estimates obtained by minimum-norm estimation, dipole fitting, and beamforming are detailed. We found that sensor position errors generally have a larger effect than orientation errors and that these errors affect the localisation accuracy of superficial sources the most. To obtain similar or higher accuracy than with current SQUID-based MEG systems, RMS sensor position and orientation errors should be [Formula: see text] and [Formula: see text], respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 2×
“Magnetoencephalography (MEG) is a non-invasive functional neuroimaging method for investigating electric neuronal activity inside the living human brain (Hämäläinen et al., 1993).”
MethodReport of the committee on methods of clinical examination in electroencephalography
(1958) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(58)90053-1 · Cited by 2,717
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561 · cited 1×
“…minimum-l1-norm estimation (Matsuura and Okabe, 1995; Uutela et al., 1999), mixed-norm estimation (Ou et al., 2009; Gramfort et al., 2012), techniques utilising multivariate source prelocalisation (Mattout et al., 2005) and different beamformer variants (Van Veen et al., 1997; Huang et al., 2004).”
MethodDale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003 · cited 2×
“Inverse metrics Minimum-norm estimation Minimum-l2-norm estimation (MNE) is a commonly used source estimation procedure (Dale and Sereno, 1993; Hämäläinen and Ilmoniemi, 1994) in which the minimisation of the l2-norm of the source estimate and the fidelity of the reconstruction of the measured…”
MethodA subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 1×
“SERF OPMs with sensitivities better than have been demonstrated (Kominis et al., 2003; Griffith et al., 2010; Colombo et al., 2016; Knappe et al., 2016).”
Pipkins, H. R., Bradshaw, J. L., Keller, L. E., Swiatlo, E., & McDaniel, L. S. (2017) · PLOS ONE · doi:10.1371/journal.pone.0179159 · Cited by 1,338
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 2×
“Especially the so-called zero-field OPMs that operate within the spin exchange relaxation-free (SERF) regime (Allred et al. 2002) appear promising as they offer high sensitivity while not Handling Editor: Seppo P.”
BackgroundVisualization of Magnetoencephalographic Data Using Minimum Current Estimates
Uutela, K., Hämäläinen, M., & Somersalo, E. (1999) · NeuroImage · doi:10.1006/nimg.1999.0454 · Cited by 512
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Research works printed but not linked: 57
- Alem O, Benison AM, Barth DS, Kitching J, Knappe S (2014) Magnetoencephalography of epilepsy with a microfabricated atomic magnetrode. J Neurosci 34(43):14324–14327. https://doi.org/10.1523/JNEUROSCI.3495-14.2014 · DOI · Paper page
- Andersen LM, Oostenveld R, Pfeiffer C, Ruffieux S, Jousmäki V, Hämäläinen M, Schneiderman JF, Lundqvist D (2017) Similarities and differences between on-scalp and conventional in-helmet magnetoencephalography recordings. PLoS ONE 12(7):1–19. https://doi.org/10.1371/journal.pone.0178602 · DOI
- Bardouille T, Krishnamurthy SV, Hajra SG, Darcy RCN (2012) Improved localization accuracy in magnetic source imaging using a 3-D laser scanner. IEEE Trans Biomed Eng 59(12):3491–3497. https://doi.org/10.1109/TBME.2012.2220356 · DOI
- Bauer H, Lamm C, Holzreiter S, Holländer I, Leodolter U, Leodolter M (2000) Measurement of 3D electrode coordinates by means of a 3D photogrammetric head digitizer. NeuroImage 11(5):S461. https://doi.org/10.1016/S1053-8119(00)91392-2 · DOI
- Baysal U, Şengül G (2010) Single camera photogrammetry system for EEG electrode identification and localization. Ann Biomed Eng 38(4):1539–1547. https://doi.org/10.1007/s10439-010-9950-4 · DOI
- Besl P, McKay N (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell 14(2):239–256. https://doi.org/10.1109/34.121791 · DOI · Paper page
- Brinkmann BH, O’Brien TJ, Dresner MA, Lagerlund TD, Sharbrough FW, Robb RA (1998) Scalp-recorded EEG localization in MRI volume data. Brain Topogr 10(4):245–253. https://doi.org/10.1023/A:1022266822252 · doi:10.1023/a:1022266822252
- Budker D, Romalis M (2007) Optical magnetometry. Nat Phys 3(4):227–234. https://doi.org/10.1038/nphys566 · DOI · Paper page
- Colombo AP, Carter TR, Borna A, Jau YY, Johnson CN, Dagel AL, Schwindt PDD (2016) Four-channel optically pumped atomic magnetometer for magnetoencephalography. Opt Express 24(14):15403–15416. https://doi.org/10.1364/OE.24.015403 · DOI · Paper page
- Cox H (1973) Resolving power and sensitivity to mismatch of optimum array processors. J Acoust Soc Am 54(3):771–785. https://doi.org/10.1121/1.1913659 · DOI · Paper page
- Dalal SS, Rampp S, Willomitzer F, Ettl S (2014) Consequences of EEG electrode position error on ultimate beamformer source reconstruction performance. Front Neurosci 8:42. https://doi.org/10.3389/fnins.2014.00042 · DOI
- Dale AM, Fischl B, Sereno MI (1999) Cortical surface-based analysis. I. Segmentation and surface reconstruction. NeuroImage 9(2):179–194. https://doi.org/10.1006/nimg.1998.0395 · DOI · Paper page
- Ettl S, Rampp S, Fouladi-Movahed S, Dalal SS, Willomitzer F, Arold O, Stefan H, Häusler G (2013) Improved EEG source localization employing 3D sensing by flying triangulation. SPIE Opt Metrol 2013:87910V. https://doi.org/10.1117/12.2020533 · DOI
- Fischl B (2012) FreeSurfer. NeuroImage 62(2):774–781. https://doi.org/10.1016/j.neuroimage.2012.01.021 · DOI · Paper page
- Fischl B, Sereno MI, Dale AM (1999a) Cortical surface-based analysis ii: inflation, flattening, and a surface-based coordinate system. NeuroImage 9(2):195–207. https://doi.org/10.1006/nimg.1998.0396 · DOI · Paper page
- Fischl B, Sereno MI, Tootell RBH, Dale AM (1999b) High-resolution intersubject averaging and a coordinate system for the cortical surface. Hum Brain Mapp 8(4):272–284. https://doi.org/10.1002/(SICI)1097-0193(1999)8:4%3c272::AID-HBM10%3e3.0.CO;2-4 · DOI · Paper page
- Goldenholz DM, Ahlfors SP, Hämäläinen MS, Sharon D, Ishitobi M, Vaina LM, Stufflebeam SM (2009) Mapping the signal-to-noise-ratios of cortical sources in magnetoencephalography and electroencephalography. Hum Brain Mapp 30(4):1077–1086. https://doi.org/10.1002/hbm.20571 · DOI · Paper page
- Gramfort A, Kowalski M, Hämäläinen M (2012) Mixed-norm estimates for the M/EEG inverse problem using accelerated gradient methods. Phys Med Biol 57(7):1937–1961. https://doi.org/10.1088/0031-9155/57/7/1937 · DOI · Paper page
- Gramfort A, Luessi M, Larson E, Engemann DA, Strohmeier D, Brodbeck C, Parkkonen L, Hämäläinen MS (2014) MNE software for processing MEG and EEG data. NeuroImage 86:446–460. https://doi.org/10.1016/j.neuroimage.2013.10.027 · DOI · Paper page
- Grave De Peralta Menendez R, Hauk O, Andino SG, Vogt H, Michel C (1997) Linear inverse solutions with optimal resolution kernels applied to electromagnetic tomography. Hum Brain Mapp 5(6):454–467. https://doi.org/10.1002/(SICI)1097-0193(1997)5:6%3c454::AID-HBM6%3e3.0.CO;2-2 · DOI · Paper page
- Griffith WC, Knappe S, Kitching J (2010) Femtotesla atomic magnetometry in a microfabricated vapor cell. Opt Express 18(26):27167–27172. https://doi.org/10.1364/OE.18.027167 · DOI · Paper page
- Hämäläinen MS, Ilmoniemi RJ (1994) Interpreting magnetic fields of the brain: minimum norm estimates. Med Biol Eng Comput 32(1):35–42. https://doi.org/10.1007/BF02512476 · DOI · Paper page
- Hansen PC, Kringelbach ML, Salmelin R (2010) MEG—an introduction to methods. MEG. https://doi.org/10.1093/acprof:oso/9780195307238.001.0001 · DOI · Paper page
- Haueisen J, Ramon C, Eiselt M, Brauer H, Nowak H (1997) Influence of tissue resistivities on neuromagnetic fields and electric potentials studied with a finite element model of the head. IEEE Trans Biomed Eng 44(8):727–735. https://doi.org/10.1109/10.605429 · DOI · Paper page
- Hauk O, Wakeman DG, Henson R (2011) Comparison of noise-normalized minimum norm estimates for MEG analysis using multiple resolution metrics. NeuroImage 54(3):1966–1974. https://doi.org/10.1016/j.neuroimage.2010.09.053 · DOI · Paper page
- Hillebrand A, Barnes GR (2003) The use of anatomical constraints with MEG beamformers. NeuroImage 20(4):2302–2313. https://doi.org/10.1016/j.neuroimage.2003.07.031 · DOI
- Hironaga N, Hagiwara K, Ogata K, Hayamizu M, Urakawa T, Tobimatsu S (2014) Proposal for a new MEG-MRI co-registration: a 3D laser scanner system. Clin Neurophysiol 125(12):2404–2412. https://doi.org/10.1016/j.clinph.2014.03.029 · DOI
- Johnson CN, Schwindt PDD, Weisend M (2013) Multi-sensor magnetoencephalography with atomic magnetometers. Phys Med Bio 58(17):6065. https://doi.org/10.1088/0031-9155/58/17/6065 · DOI · Paper page
- Kamada K, Sato D, Ito Y, Natsukawa H, Okano K, Mizutani N, Kobayashi T (2015) Human magnetoencephalogram measurements using newly developed compact module of high-sensitivity atomic magnetometer. Jpn J Appl Phys 54(2):026601. https://doi.org/10.7567/JJAP.54.026601 · DOI · Paper page
- Knappe S, Mhaskar R, Preusser J, Kitching J, Trahms L, Sander T (2011) Chip-scale room-temperature atomic magnetometers for biomedical measurements. IFMBE Proc 37:1330–1333. https://doi.org/10.1007/978-3-642-23508-5_343 · DOI
- Knappe S, Sander T, Trahms L (2014) Optically-Pumped Magnetometers for MEG. In: Supek S, Aine CJ (eds) Magnetoencephalography: from signals to dynamic cortical networks, Springer, Heidelberg, pp. 993–999, https://doi.org/10.1007/978-3-642-33045-2_49 . · DOI
- Knappe S, Alem O, Sheng D, Kitching J (2016) Microfabricated optically-pumped magnetometers for biomagnetic applications. J Phys 723:012055. https://doi.org/10.1088/1742-6596/723/1/012055 · DOI · Paper page
- Koessler L, Maillard L, Benhadid A, Vignal JP, Braun M, Vespignani H (2007) Spatial localization of EEG electrodes. Neurophysiol Clin 37(2):97–102. https://doi.org/10.1016/j.neucli.2007.03.002 · DOI
- Koessler L, Cecchin T, Ternisien E, Maillard L (2010) 3D handheld laser scanner based approach for automatic identification and localization of EEG sensors. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC’10, pp 3707–3710, https://doi.org/10.1109/IEMBS.2010.5627659 · doi:10.1109/iembs.2010.5627659
- Koessler L, Cecchin T, Caspary O, Benhadid A, Vespignani H, Maillard L (2011) EEG-MRI co-registration and sensor labeling using a 3D laser scanner. Ann Biomed Eng 39(3):983–995. https://doi.org/10.1007/s10439-010-0230-0 · DOI
- Kozinska D, Tretiak OJ, Nissanov J, Ozturk C (1997) Multidimensional alignment using the euclidean distance transform. Graph Models Image Process 59(6):373–387. https://doi.org/10.1006/gmip.1997.0447 · doi:10.1006/gmip.1997.0447
- Kozinska D, Carducci F, Nowinski K (2001) Automatic alignment of EEG/MEG and MRI data sets. Clin Neurophysiol 112(8):1553–1561. https://doi.org/10.1016/S1388-2457(01)00556-9 · DOI
- Lin FH, Witzel T, Ahlfors SP, Stufflebeam SM, Belliveau JW, Hämäläinen MS (2006) Assessing and improving the spatial accuracy in MEG source localization by depth-weighted minimum-norm estimates. NeuroImage 31(1):160–171. https://doi.org/10.1016/j.neuroimage.2005.11.054 · DOI · Paper page
- Mattout J, Pélégrini-Issac M, Garnero L, Benali H (2005) Multivariate source prelocalization (MSP): use of functionally informed basis functions for better conditioning the MEG inverse problem. NeuroImage 26(2):356–373. https://doi.org/10.1016/j.neuroimage.2005.01.026 · DOI · Paper page
- Murthy SVK, MacLellan M, Beyea S, Bardouille T (2014) Faster and improved 3-D head digitization in MEG using kinect. Front Neurosci 8:1–7. https://doi.org/10.3389/fnins.2014.00326 · DOI
- Nurminen J, Taulu S, Okada Y (2008) Effects of sensor calibration, balancing and parametrization on the signal space separation method. Phys Med Biol 53(7):1975–1987. https://doi.org/10.1088/0031-9155/53/7/012 · DOI
- Öisjöen F, Schneiderman JF, Figueras GA, Chukharkin ML, Kalabukhov A, Hedström A, Elam M, Winkler D (2012) High-Tc superconducting quantum interference device recordings of spontaneous brain activity: towards high-Tc magnetoencephalography. Appl Phys Lett 100(13):132601. https://doi.org/10.1063/1.3698152 · DOI · Paper page
- Ou W, Hämäläinen MS, Golland P (2009) A distributed spatio-temporal EEG/MEG inverse solver. NeuroImage 44(3):932–946. https://doi.org/10.1016/j.neuroimage.2008.05.063 · DOI · Paper page
- Riaz B, Pfeiffer C, Schneiderman JF (2017) Evaluation of realistic layouts for next generation on-scalp MEG: spatial information density maps. Sci Rep 7(1):6974. https://doi.org/10.1038/s41598-017-07046-6 · DOI · Paper page
- Russell GS, Eriksen KJ, Poolman P, Luu P, Tucker DM (2005) Geodesic photogrammetry for localizing sensor positions in dense-array EEG. Clin Neurophysiol 116(5):1130–1140. https://doi.org/10.1016/j.clinph.2004.12.022 · DOI
- Sander TH, Preusser J, Mhaskar R, Kitching J, Trahms L, Knappe S (2012) Magnetoencephalography with a chip-scale atomic magnetometer. Biomed Opt Express 3(5):981. https://doi.org/10.1364/BOE.3.000981 · DOI · Paper page
- Ségonne F, Dale AM, Busa E, Glessner M, Salat D, Hahn HK, Fischl B (2004) A hybrid approach to the skull stripping problem in MRI. NeuroImage 22(3):1060–1075. https://doi.org/10.1016/j.neuroimage.2004.03.032 · DOI · Paper page
- Sekihara K, Nagarajan SS (2008) Adaptive spatial filters for electromagnetic brain imaging. Springer Science & Business Media, New York. https://doi.org/10.1007/978-3-540-79370-0 · DOI · Paper page
- Sekihara K, Nagarajan SS, Poeppel D, Marantz A (2004) Asymptotic SNR of scalar and vector minimum-variance beanformers for neuromagnetic source reconstruction. IEEE Trans Biomed Eng 51(10):1726–1734. https://doi.org/10.1109/TBME.2004.827926 · DOI · Paper page
- Shah V, Knappe S, Schwindt PDD, Kitching J (2007) Subpicotesla atomic magnetometry with a microfabricated vapour cell. Nat Photonics 1(11):649–652. https://doi.org/10.1038/nphoton.2007.201 · DOI · Paper page
- Stenroos M, Hauk O (2013) Minimum-norm cortical source estimation in layered head models is robust against skull conductivity error. NeuroImage 81:265–272. https://doi.org/10.1016/j.neuroimage.2013.04.086 · DOI · Paper page
- Stenroos M, Sarvas J (2012) Bioelectromagnetic forward problem: isolated source approach revis(it)ed. Phys Med Biol 57(11):3517–3535. https://doi.org/10.1088/0031-9155/57/11/3517 · DOI
- Taulu S, Kajola M (2005) Presentation of electromagnetic multichannel data: the signal space separation method. J Appl Phys. https://doi.org/10.1063/1.1935742 · DOI · Paper page
- Troebinger L, López JD, Lutti A, Bradbury D, Bestmann S, Barnes G (2014) High precision anatomy for MEG. NeuroImage 86:583–591. https://doi.org/10.1016/j.neuroimage.2013.07.065 · DOI · Paper page
- Wang Y, Gotman J (2001) The influence of electrode location errors on EEG dipole source localization with a realistic head model. Clin Neurophysiol 112(9):1777–1780. https://doi.org/10.1016/S1388-2457(01)00594-6 · DOI
- Whalen C, Maclin EL, Fabiani M, Gratton G (2008) Validation of a method for coregistering scalp recording locations with 3D structural MR images. Hum Brain Mapp 29(11):1288–1301. https://doi.org/10.1002/hbm.20465 · DOI · Paper page
- Xia H, Ben-Amar Baranga A, Hoffman D, Romalis MV (2006) Magnetoencephalography with an atomic magnetometer. Appl Phys Lett 89(21):211104. https://doi.org/10.1063/1.2392722 · DOI · Paper page
Cited by
Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
“Nowadays, only spinexchange relaxation free variants have been used for magnetoencephalography [28,139,140].”
MethodOn-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K., & Parkkonen, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.022 · Cited by 269
Self-citationNon-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System
Borna, A., Carter, T. R., Colombo, A. P., Jau, Y.-Y., McKay, J., Weisend, M., Taulu, S., Stephen, J. M., & Schwindt, P. D. D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227684 · Cited by 158
Metadata
- Authors
- Zetter, R., Iivanainen, J., Stenroos, M., & Parkkonen, L.
- Venue
- Brain Topography
- Published
- 2018-06-22
- Volume
- 31
- Issue
- 6
- Pages
- 931-948
- ISSN
- 0896-0267 (ISSN-L)
- 1573-6792
- OpenAlex
- W2949224319
- Cited by
- 56
- References
- 16
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Funders
- National Institute of Neurological Disorders and Stroke (R01NS094604)
- European Research Council (678578)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Requirements for Coregistration Accuracy in On-Scalp MEG. https://app.cochat.ai/papers/10.1007/s10548-018-0656-5
- The paper
- Zetter, R., Iivanainen, J., Stenroos, M., & Parkkonen, L. (2018). Requirements for Coregistration Accuracy in On-Scalp MEG. Brain Topography. https://doi.org/10.1007/s10548-018-0656-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.