Repeatability of Multiparametric Prostate MRI Radiomics Features
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
In this study we assessed the repeatability of radiomics features on small prostate tumors using test-retest Multiparametric Magnetic Resonance Imaging (mpMRI). The premise of radiomics is that quantitative image-based features can serve as biomarkers for detecting and characterizing disease. For such biomarkers to be useful, repeatability is a basic requirement, meaning its value must remain stable between two scans, if the conditions remain stable. We investigated repeatability of radiomics features under various preprocessing and extraction configurations including various image normalization schemes, different image pre-filtering, and different bin widths for image discretization. Although we found many radiomics features and preprocessing combinations with high repeatability (Intraclass Correlation Coefficient > 0.85), our results indicate that overall the repeatability is highly sensitive to the processing parameters. Neither image normalization, using a variety of approaches, nor the use of pre-filtering options resulted in consistent improvements in repeatability. We urge caution when interpreting radiomics features and advise paying close attention to the processing configuration details of reported results. Furthermore, we advocate reporting all processing details in radiomics studies and strongly recommend the use of open source implementations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Ultrastructural Characterization of the Lower Motor System in a Mouse Model of Krabbe Disease
Cappello, V., Marchetti, L., Parlanti, P., Landi, S., Tonazzini, I., Cecchini, M., Piazza, V., & Gemmi, M. (2016) · Scientific Reports · doi:10.1038/s41598-016-0001-8 · Cited by 13,097
On Estimation of a Probability Density Function and Mode
Parzen, E. (1962) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177704472 · Cited by 10,585
3D Slicer as an image computing platform for the Quantitative Imaging Network
Fedorov, A., Beichel, R., Kalpathy-Cramer, J., Finet, J., Fillion-Robin, J.-C., Pujol, S., Bauer, C., Jennings, D., Fennessy, F., Sonka, M., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.05.001 · Cited by 9,023
Self-citationComputational Radiomics System to Decode the Radiographic Phenotype
(2017) · doi:10.1158/0008-5472.can-17-0339 · Cited by 6,593
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Self-citationN4ITK: Improved N3 Bias Correction
Tustison, N. J., Avants, B. B., Cook, P. A., Zheng, Y., Egan, A., Yushkevich, P. A., & Gee, J. C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2046908 · Cited by 6,073
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Self-citationRemarks on Some Nonparametric Estimates of a Density Function
Rosenblatt, M. (1956) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177728190 · Cited by 4,547
PI-RADS Prostate Imaging – Reporting and Data System: 2015, Version 2
Weinreb, J. C., Barentsz, J. O., Choyke, P. L., Cornud, F., Haider, M. A., Macura, K. J., Margolis, D., Schnall, M. D., Shtern, F., Tempany, C. M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.08.052 · Cited by 2,951
Self-citationESUR prostate MR guidelines 2012
Barentsz, J. O., Richenberg, J., Clements, R., Choyke, P., Verma, S., Villeirs, G., Rouviere, O., Logager, V., & Fütterer, J. J. (2012) · European Radiology · doi:10.1007/s00330-011-2377-y · Cited by 2,438
Radiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258 · cited 2×
“Since there is no systematic difference between the first and second scans, we model both between-subject and within-subject sources of variability as independent random effects and ICC(1,1) is therefore appropriate.”
MethodSelf-citationApplications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Self-citationImaging biomarker roadmap for cancer studies
O'Connor, J. P. B., Aboagye, E. O., Adams, J. E., Aerts, H. J. W. L., Barrington, S. F., Beer, A. J., Boellaard, R., Bohndiek, S. E., Brady, M., Brown, G., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2016.162 · Cited by 1,091
Self-citationMachine Learning methods for Quantitative Radiomic Biomarkers
Parmar, C., Grossmann, P., Bussink, J., Lambin, P., & Aerts, H. J. W. L. (2015) · Scientific Reports · doi:10.1038/srep13087 · Cited by 1,019
Self-citationNew variants of a method of MRI scale standardization
Nyul, L. G., Udupa, J. K., & Zhang, X. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836373 · Cited by 956
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
Robust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation
Parmar, C., Rios Velazquez, E., Leijenaar, R., Jermoumi, M., Carvalho, S., Mak, R. H., Mitra, S., Shankar, B. U., Kikinis, R., Haibe-Kains, B., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102107 · Cited by 611
Self-citationHambrock, T., Somford, D. M., Huisman, H. J., van Oort, I. M., Witjes, J. A., Hulsbergen-van de Kaa, C. A., Scheenen, T., & Barentsz, J. O. (2011) · Radiology · doi:10.1148/radiol.11091409 · Cited by 572
Reproducibility of radiomics for deciphering tumor phenotype with imaging
Zhao, B., Tan, Y., Tsai, W.-Y., Qi, J., Xie, C., Lu, L., & Schwartz, L. H. (2016) · Scientific Reports · doi:10.1038/srep23428 · Cited by 509
Leijenaar, R. T. H., Carvalho, S., Velazquez, E. R., van Elmpt, W. J. C., Parmar, C., Hoekstra, O. S., Hoekstra, C. J., Boellaard, R., Dekker, A. L. A. J., Gillies, R. J., et al. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.812798 · Cited by 427
Self-citationLeijenaar, R. T. H., Nalbantov, G., Carvalho, S., van Elmpt, W. J. C., Troost, E. G. C., Boellaard, R., Aerts, H. J. W. L., Gillies, R. J., & Lambin, P. (2015) · Scientific Reports · doi:10.1038/srep11075 · Cited by 426
Self-citationStatistical normalization techniques for magnetic resonance imaging
Shinohara, R. T., Sweeney, E. M., Goldsmith, J., Shiee, N., Mateen, F. J., Calabresi, P. A., Jarso, S., Pham, D. L., Reich, D. S., & Crainiceanu, C. M. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.08.008 · Cited by 425
Radiomic Machine-Learning Classifiers for Prognostic Biomarkers of Head and Neck Cancer
Parmar, C., Grossmann, P., Rietveld, D., Rietbergen, M. M., Lambin, P., & Aerts, H. J. W. L. (2015) · Frontiers in Oncology · doi:10.3389/fonc.2015.00272 · Cited by 407
Self-citationRaunig, D. L., McShane, L. M., Pennello, G., Gatsonis, C., Carson, P. L., Voyvodic, J. T., Wahl, R. L., Kurland, B. F., Schwarz, A. J., Gönen, M., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537344 · Cited by 394
Wibmer, A., Hricak, H., Gondo, T., Matsumoto, K., Veeraraghavan, H., Fehr, D., Zheng, J., Goldman, D., Moskowitz, C., Fine, S. W., et al. (2015) · European Radiology · doi:10.1007/s00330-015-3701-8 · Cited by 391
Somatic Mutations Drive Distinct Imaging Phenotypes in Lung Cancer
Rios Velazquez, E., Parmar, C., Liu, Y., Coroller, T. P., Cruz, G., Stringfield, O., Ye, Z., Makrigiorgos, M., Fennessy, F., Mak, R. H., et al. (2017) · Cancer Research · doi:10.1158/0008-5472.can-17-0122 · Cited by 391
Self-citationFehr, D., Veeraraghavan, H., Wibmer, A., Gondo, T., Matsumoto, K., Vargas, H. A., Sala, E., Hricak, H., & Deasy, J. O. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1505935112 · Cited by 382
False Discovery Rates in PET and CT Studies with Texture Features: A Systematic Review
Chalkidou, A., O’Doherty, M. J., & Marsden, P. K. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124165 · Cited by 344
Zhao, B., James, L. P., Moskowitz, C. S., Guo, P., Ginsberg, M. S., Lefkowitz, R. A., Qin, Y., Riely, G. J., Kris, M. G., & Schwartz, L. H. (2009) · Radiology · doi:10.1148/radiol.2522081593 · Cited by 339
Glioblastoma Multiforme: Exploratory Radiogenomic Analysis by Using Quantitative Image Features
Gevaert, O., Mitchell, L. A., Achrol, A. S., Xu, J., Echegaray, S., Steinberg, G. K., Cheshier, S. H., Napel, S., Zaharchuk, G., & Plevritis, S. K. (2014) · Radiology · doi:10.1148/radiol.14131731 · Cited by 319
Tixier, F., Hatt, M., Le Rest, C. C., Le Pogam, A., Corcos, L., & Visvikis, D. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.099127 · Cited by 318
van Velden, F. H. P., Kramer, G. M., Frings, V., Nissen, I. A., Mulder, E. R., de Langen, A. J., Hoekstra, O. S., Smit, E. F., & Boellaard, R. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-0940-2 · Cited by 286
Test–Retest Reproducibility Analysis of Lung CT Image Features
Balagurunathan, Y., Kumar, V., Gu, Y., Kim, J., Wang, H., Liu, Y., Goldgof, D. B., Hall, L. O., Korn, R., Zhao, B., et al. (2014) · Journal of Digital Imaging · doi:10.1007/s10278-014-9716-x · Cited by 259
Abbreviated Biparametric Prostate MR Imaging in Men with Elevated Prostate-specific Antigen
Kuhl, C. K., Bruhn, R., Krämer, N., Nebelung, S., Heidenreich, A., & Schrading, S. (2017) · Radiology · doi:10.1148/radiol.2017170129 · Cited by 253
Peng, Y., Jiang, Y., Yang, C., Brown, J. B., Antic, T., Sethi, I., Schmid-Tannwald, C., Giger, M. L., Eggener, S. E., & Oto, A. (2013) · Radiology · doi:10.1148/radiol.13121454 · Cited by 250
Jain, R., Poisson, L. M., Gutman, D., Scarpace, L., Hwang, S. N., Holder, C. A., Wintermark, M., Rao, A., Colen, R. R., Kirby, J., et al. (2014) · Radiology · doi:10.1148/radiol.14131691 · Cited by 234
Bonekamp, D., Kohl, S., Wiesenfarth, M., Schelb, P., Radtke, J. P., Götz, M., Kickingereder, P., Yaqubi, K., Hitthaler, B., Gählert, N., et al. (2018) · Radiology · doi:10.1148/radiol.2018173064 · Cited by 202
Malyarenko, D., Galbán, C. J., Londy, F. J., Meyer, C. R., Johnson, T. D., Rehemtulla, A., Ross, B. D., & Chenevert, T. L. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23825 · Cited by 197
MAPS: A Quantitative Radiomics Approach for Prostate Cancer Detection
Cameron, A., Khalvati, F., Haider, M. A., & Wong, A. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2485779 · Cited by 185
Quantification of Heterogeneity as a Biomarker in Tumor Imaging: A Systematic Review
Alic, L., Niessen, W. J., & Veenland, J. F. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110300 · Cited by 164
Desseroit, M.-C., Tixier, F., Weber, W. A., Siegel, B. A., Cheze Le Rest, C., Visvikis, D., & Hatt, M. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.180919 · Cited by 160
Hunter, L. A., Krafft, S., Stingo, F., Choi, H., Martel, M. K., Kry, S. F., & Court, L. E. (2013) · Medical Physics · doi:10.1118/1.4829514 · Cited by 117
Fedorov, A., Vangel, M. G., Tempany, C. M., & Fennessy, F. M. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000382 · Cited by 76
Self-citationReproducibility with repeat CT in radiomics study for rectal cancer
Hu, P., Wang, J., Zhong, H., Zhou, Z., Shen, L., Hu, W., & Zhang, Z. (2016) · Oncotarget · doi:10.18632/oncotarget.12199 · Cited by 74
Barnhart, H. X., Yow, E. S., Crowley, A. L., Daubert, M. A., Rabineau, D., Bigelow, R., Pencina, M. J., & Douglas, P. S. (2016) · Statistical Methods in Medical Research · doi:10.1177/0962280214534651 · Cited by 69
Radiomics and radiogenomics of prostate cancer
Smith, C. P., Czarniecki, M., Mehralivand, S., Stoyanova, R. S., Choyke, P. L., Harmon, S. A., & Türkbey, B. (2018) · Abdominal Radiology · doi:10.1007/s00261-018-1660-7 · Cited by 68
Bologna, M., Corino, V., Montin, E., Messina, A., Calareso, G., Greco, F. G., Sdao, S., & Mainardi, L. T. (2018) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-018-0092-9 · Cited by 67
Carvalho, S., Leijenaar, R. T. H., Velazquez, E. R., Oberije, C., Parmar, C., van Elmpt, W., Reymen, B. J. T., Troost, E. G. C., Öllers, M., Dekker, A. L. A. J., et al. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.812795 · Cited by 58
Self-citationGlioblastoma Multiforme: Exploratory Radiogenomic Analysis by Using Quantitative Image Features
Gevaert, O., Mitchell, L. A., Achrol, A. S., Xu, J., Echegaray, S., Steinberg, G. K., Cheshier, S. H., Napel, S. A., Zaharchuk, G., & Plevritis, S. K. (2015) · Radiology · doi:10.1148/radiol.2015154019 · Cited by 58
An annotated test-retest collection of prostate multiparametric MRI
Fedorov, A., Schwier, M., Clunie, D., Herz, C., Pieper, S., Kikinis, R., Tempany, C. M., & Fennessy, F. (2018) · Scientific Data · doi:10.1038/sdata.2018.281 · Cited by 52
Self-citationClassification of suspicious lesions on prostate multiparametric MRI using machine learning
(2018) · Journal of Medical Imaging · doi:10.1117/1.jmi.5.3.034502 · Cited by 40
Chirra, P. V., Bloch, B., Rastinehad, A. R., Purysko, A. S., Madabhushi, A., Viswanath, S. E., Leo, P., Yim, M. C., & Rosen, M. A. (2018) · SPIE Medical Imaging: Computer-Aided Diagnosis · doi:10.1117/12.2293992 · Cited by 34
Wang, X., Velcheti, V., Vaidya, P., Bera, K., Madabhushi, A., Khunger, A., Patil, P. D., & Choi, H. (2018) · SPIE Medical Imaging: Digital and Computational Pathology · doi:10.1117/12.2296646 · Cited by 21
Emaminejad, N., Kim, G. H., Brown, M. S., McNitt‐Gray, M. F., Hoffman, J., & Wahi‐Anwar, M. (2018) · SPIE Medical Imaging: Computer-Aided Diagnosis · doi:10.1117/12.2293864 · Cited by 6
Cited by
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
AI applications to medical images: From machine learning to deep learning
Castiglioni, I., Rundo, L., Codari, M., Di Leo, G., Salvatore, C., Interlenghi, M., Gallivanone, F., Cozzi, A., D'Amico, N. C., & Sardanelli, F. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.02.006 · Cited by 710
Scapicchio, C., Gabelloni, M., Barucci, A., Cioni, D., Saba, L., & Neri, E. (2021) · La radiologia medica · doi:10.1007/s11547-021-01389-x · Cited by 435
Artificial intelligence and machine learning in cancer imaging
Koh, D.-M., Papanikolaou, N., Bick, U., Illing, R., Kahn, C. E., Kalpathi-Cramer, J., Matos, C., Martí-Bonmatí, L., Miles, A., Mun, S. K., et al. (2022) · Communications Medicine · doi:10.1038/s43856-022-00199-0 · Cited by 311
Carré, A., Klausner, G., Edjlali, M., Lerousseau, M., Briend-Diop, J., Sun, R., Ammari, S., Reuzé, S., Alvarez Andres, E., Estienne, T., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-69298-z · Cited by 278
Metadata
- Authors
- Schwier, M., van Griethuysen, J., Vangel, M. G., Pieper, S., Peled, S., Tempany, C., Aerts, H. J. W. L., Kikinis, R., Fennessy, F. M., & Fedorov, A.
- Venue
- Scientific Reports
- Published
- 2019-07-01
- Volume
- 9
- Issue
- 1
- Pages
- 9441-9441
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2883648998
- Cited by
- 237
- References
- 56
- FWCI
- 23.85
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.