Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
Artificial Intelligence (AI) has long promised to increase healthcare affordability, quality and accessibility but FDA, until recently, had never authorized an autonomous AI diagnostic system. This pivotal trial of an AI system to detect diabetic retinopathy (DR) in people with diabetes enrolled 900 subjects, with no history of DR at primary care clinics, by comparing to Wisconsin Fundus Photograph Reading Center (FPRC) widefield stereoscopic photography and macular Optical Coherence Tomography (OCT), by FPRC certified photographers, and FPRC grading of Early Treatment Diabetic Retinopathy Study Severity Scale (ETDRS) and Diabetic Macular Edema (DME). More than mild DR (mtmDR) was defined as ETDRS level 35 or higher, and/or DME, in at least one eye. AI system operators underwent a standardized training protocol before study start. Median age was 59 years (range, 22–84 years); among participants, 47.5% of participants were male; 16.1% were Hispanic, 83.3% not Hispanic; 28.6% African American and 63.4% were not; 198 (23.8%) had mtmDR. The AI system exceeded all pre-specified superiority endpoints at sensitivity of 87.2% (95% CI, 81.8–91.2%) (>85%), specificity of 90.7% (95% CI, 88.3–92.7%) (>82.5%), and imageability rate of 96.1% (95% CI, 94.6–97.3%), demonstrating AI’s ability to bring specialty-level diagnostics to primary care settings. Based on these results, FDA authorized the system for use by health care providers to detect more than mild DR and diabetic macular edema, making it, the first FDA authorized autonomous AI diagnostic system in any field of medicine, with the potential to help prevent vision loss in thousands of people with diabetes annually. ClinicalTrials.gov NCT02963441
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“The regulatory approval of the first diagnostic autonomous AI system for diabetic eye exams was based on a pivotal trial against a prognostic standard, i.e., patient outcome24, showing its safety, efficacy, and lack of racial and ethnic bias for diagnosing DED in adults with diabetes with 87% sensitivity and 91% specificity24.”
From Autonomous artificial intelligence increases screening and follow-up for diabetic retinopathy in youth: the ACCESS randomized control trial (2024) · cites this paper as [24]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Only eight studies in ophthalmology imaging14,21,32,33,43,55,108,109, ten studies in respiratory imaging64,66,70,72,75,79,82,87,89,110 and six studies in breast imaging62,91,97,104,106,111 mentioned adherence to the STARD-2015 guidelines or had a STARD flow diagram in the manuscript.”
From Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis (2021) · cites this paper as [14]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These systems use large annotated datasets to learn hierarchical features directly from images, improving reproducibility and reducing reliance on manual feature engineering [27,34].”
From Artificial Intelligence in Clinical Decision-Making: A Comprehensive Review of Diagnostic, Prognostic, and Therapeutic Applications, Validation Gaps, Bias, and Deployment Challenges (2026) · cites this paper as [27]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In clinical workflows, AI supports triage prioritisation, second-opinion review, and reduction of diagnostic variability in high-volume settings [15,27].”
From Artificial Intelligence in Clinical Decision-Making: A Comprehensive Review of Diagnostic, Prognostic, and Therapeutic Applications, Validation Gaps, Bias, and Deployment Challenges (2026) · cites this paper as [27]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Adoption in clinical practice is influenced by clinician interaction with AI systems, including trust and workflow compatibility [23,27].”
From Artificial Intelligence in Clinical Decision-Making: A Comprehensive Review of Diagnostic, Prognostic, and Therapeutic Applications, Validation Gaps, Bias, and Deployment Challenges (2026) · cites this paper as [27]
Experimental — accuracy not yet measured
18 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Diagnosis and Classification of Diabetes Mellitus
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s062 · Cited by 13,988
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Centers for Disease Control and Prevention
(2007) · Encyclopedia of Measurement and Statistics · doi:10.4135/9781412952644.n74 · Cited by 6,444
Diagnosis and classification of diabetes mellitus
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s081 · Cited by 5,974
(2007) · Developments in Ophthalmology · doi:10.1159/isbn.978-3-318-01439-6 · Cited by 5,583
Bias reduction of maximum likelihood estimates
FIRTH, D. (1993) · Biometrika · doi:10.1093/biomet/80.1.27 · Cited by 5,035
Wilkinson, C. P., Ferris, F. L., Klein, R. E., Lee, P. P., Agardh, C. D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., & Verdaguer, J. T. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00475-5 · Cited by 3,743
Classification and Diagnosis of Diabetes
Fajans, S. S. (1990) · Medical Entomology and Zoology · Cited by 2,359
(2) Classification and diagnosis of diabetes
American Diabetes Association (2015) · Diabetes Care · doi:10.2337/dc15-s005 · Cited by 1,841
Aflibercept, Bevacizumab, or Ranibizumab for Diabetic Macular Edema
The Diabetic Retinopathy Clinical Research Network (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1414264 · Cited by 1,607
The Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
McGuire, S. (2014) · Advances in Nutrition · doi:10.3945/an.114.007211 · Cited by 1,122
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Self-citation(2015) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(15)00291-0 · Cited by 1,029
Fundus Photographic Risk Factors for Progression of Diabetic Retinopathy
(1991) · Ophthalmology · doi:10.1016/s0161-6420(13)38014-2 · Cited by 814
Liew, G., Michaelides, M., & Bunce, C. (2014) · BMJ Open · doi:10.1136/bmjopen-2013-004015 · Cited by 663
Automatic detection of red lesions in digital color fundus photographs
Niemeijer, M., van Ginneken, B., Staal, J., Suttorp-Schulten, M. S. A., & Abramoff, M. D. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.843738 · Cited by 504
Self-citationAutomated Analysis of Retinal Images for Detection of Referable Diabetic Retinopathy
Abràmoff, M. D., Folk, J. C., Han, D. P., Walker, J. D., Williams, D. F., Russell, S. R., Massin, P., Cochener, B., Gain, P., Tang, L., et al. (2013) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2013.1743 · Cited by 463
Self-citationNiemeijer, M., van Ginneken, B., Russell, S. R., Suttorp-Schulten, M. S. A., & Abra`moff, M. D. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0996 · Cited by 400
Self-citation(2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2008.610 · Cited by 398
Screening for HIV: U.S. Preventive Services Task Force Recommendation Statement
Moyer, V. A. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-1-201307020-00645 · Cited by 393
Lin, D. Y., Blumenkranz, M. S., Brothers, R. J., & Grosvenor, D. M. (2002) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)01522-2 · Cited by 327
Automated Early Detection of Diabetic Retinopathy
Abràmoff, M. D., Reinhardt, J. M., Russell, S. R., Folk, J. C., Mahajan, V. B., Niemeijer, M., & Quellec, G. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.03.046 · Cited by 287
Self-citationAbràmoff, M. D., Niemeijer, M., Suttorp-Schulten, M. S. A., Viergever, M. A., Russell, S. R., & van Ginneken, B. (2008) · Diabetes Care · doi:10.2337/dc07-1312 · Cited by 277
Self-citationEffect of Ruboxistaurin on Visual Loss in Patients with Diabetic Retinopathy
(2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.07.032 · Cited by 276
An economic analysis of interventions for diabetes.
Klonoff, D. C., & Schwartz, D. M. (2000) · Diabetes Care · doi:10.2337/diacare.23.3.390 · Cited by 267
Abra`moff, M. D., Alward, W. L. M., Greenlee, E. C., Shuba, L., Kim, C. Y., Fingert, J. H., & Kwon, Y. H. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-1081 · Cited by 236
Self-citationFong, D. S., Aiello, L., Gardner, T. W., King, G. L., Blankenship, G., Cavallerano, J. D., Ferris, F. L., Klein, R., & American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.1.226 · Cited by 233
Levels of categorization in visual recognition studied using functional magnetic resonance imaging
Gauthier, I., Anderson, A. W., Tarr, M. J., Skudlarski, P., & Gore, J. C. (1997) · Current Biology · doi:10.1016/s0960-9822(06)00291-0 · Cited by 229
Diabetic retinopathy is a neurodegenerative disorder
Lynch, S. K., & Abràmoff, M. D. (2017) · Vision Research · doi:10.1016/j.visres.2017.03.003 · Cited by 199
Self-citationScreening for Diabetic Retinopathy: The wide-angle retinal camera
Pugh, J. A., Jacobson, J. M., Van Heuven, W. A. J., Watters, J. A., Tuley, M. R., Lairson, D. R., Lorimor, R. J., Kapadia, A. S., & Velez, R. (1993) · Diabetes Care · doi:10.2337/diacare.16.6.889 · Cited by 172
Polk, T. A., & Farah, M. J. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.3.847 · Cited by 169
Hollands, H., Johnson, D., Hollands, S., Simel, D. L., Jinapriya, D., & Sharma, S. (2013) · JAMA · doi:10.1001/jama.2013.5099 · Cited by 158
Ahmed, J., Ward, T. P., Bursell, S.-E., Aiello, L. M., Cavallerano, J. D., & Vigersky, R. A. (2006) · Diabetes Care · doi:10.2337/dc06-0295 · Cited by 152
Niemeijer, M., Abràmoff, M. D., & van Ginneken, B. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.09.006 · Cited by 146
Self-citationScreening for Presence or Absence of Diabetic Retinopathy: A Meta-analysis
Bragge, P. (2011) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2010.319 · Cited by 134
Scanlon, P. H. (2008) · Journal of Medical Screening · doi:10.1258/jms.2008.008015 · Cited by 132
Web-Based Screening for Diabetic Retinopathy in a Primary Care Population: The EyeCheck Project
Abramoff, M. D., & Suttorp-Schulten, M. S. A. (2005) · Telemedicine and e-Health · doi:10.1089/tmj.2005.11.668 · Cited by 125
Self-citationOptimal Filter Framework for Automated, Instantaneous Detection of Lesions in Retinal Images
Quellec, G., Russell, S. R., & Abràmoff, M. D. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2089383 · Cited by 125
Self-citationInformation Fusion for Diabetic Retinopathy CAD in Digital Color Fundus Photographs
Niemeijer, M., Abràmoff, M. D., & van Ginneken, B. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2012029 · Cited by 125
Self-citationHarley, E. M., Pope, W. B., Villablanca, J. P., Mumford, J., Suh, R., Mazziotta, J. C., Enzmann, D., & Engel, S. A. (2009) · Cerebral Cortex · doi:10.1093/cercor/bhp051 · Cited by 103
Chou, R., Dana, T., Bougatsos, C., Grusing, S., & Blazina, I. (2016) · JAMA · doi:10.1001/jama.2016.0783 · Cited by 101
Wang, Y. T., Tadarati, M., Wolfson, Y., Bressler, S. B., & Bressler, N. M. (2016) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.5332 · Cited by 100
Screening for Glaucoma: U.S. Preventive Services Task Force Recommendation Statement
Moyer, V. A. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-6-201309170-00686 · Cited by 96
Hansen, M. B., Abràmoff, M. D., Folk, J. C., Mathenge, W., Bastawrous, A., & Peto, T. (2015) · PLOS ONE · doi:10.1371/journal.pone.0139148 · Cited by 93
Self-citationFarah, M. J., & Aguirre, G. K. (1999) · Trends in Cognitive Sciences · doi:10.1016/s1364-6613(99)01309-1 · Cited by 91
Automated lesion detectors in retinal fundus images
Figueiredo, I. N., Kumar, S., Oliveira, C. M., Ramos, J. D., & Engquist, B. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.08.008 · Cited by 66
Hazin, R., Colyer, M. H., Lum, F., & Barazi, M. K. (2011) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2011.06.022 · Cited by 59
Improved Automated Screening of Diabetic Retinopathy
Oliveira, C. M., Cristóvão, L. M., Ribeiro, M. L., & Abreu, J. R. F. (2011) · Ophthalmologica · doi:10.1159/000330285 · Cited by 59
Gangaputra, S., Lovato, J. F., Hubbard, L., Davis, M. D., Esser, B. A., Ambrosius, W. T., Chew, E. Y., Greven, C., Perdue, L. H., Wong, W. T., et al. (2013) · Retina · doi:10.1097/iae.0b013e318286c952 · Cited by 44
Hendricks, L. E., & Hendricks, R. T. (1998) · The Science of Diabetes Self-Management and Care · doi:10.1177/014572179802400206 · Cited by 40
Evaluation of the Age-Related Eye Disease Study Clinical Lens Grading System
Chew, E. Y., Kim, J., Sperduto, R. D., Datiles, M. B., Coleman, H. R., Thompson, D. J. S., Milton, R. C., Clayton, J. A., Hubbard, L. D., Danis, R. P., et al. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.02.033 · Cited by 39
Shah, A., Lynch, S., Niemeijer, M., Amelon, R., Clarida, W., Folk, J., Russell, S., Wu, X., & Abramoff, M. D. (2018) · 2018 IEEE 15th International Symposium on Biomedical Imaging (ISBI 2018) · doi:10.1109/isbi.2018.8363846 · Cited by 38 · cited 1×
“These physiologically plausible algorithms have been shown to be more robust to small perturbations in input images, possibly because they have partially dependent, and thus redundant detectors.(39) Additionally, microaneurysms have been long recognized as the earliest retinal sign of DR that is seen on ophthalmoscopi…”
BackgroundSelf-citationMonoscopic versus Stereoscopic Retinal Photography for Grading Diabetic Retinopathy Severity
Li, H. K., Hubbard, L. D., Danis, R. P., Esquivel, A., Florez-Arango, J. F., & Krupinski, E. A. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-4886 · Cited by 33
Li, H. K., Danis, R. P., Hubbard, L. D., Florez-Arango, J. F., Esquivel, A., & Krupinski, E. A. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-6303 · Cited by 31
The vascular lesions of diabetic retinopathy.
Friedenwald, J. S., & DAY, R. (1950) · PubMed · Cited by 27
Quellec, G., & Abramoff, M. D. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6943552 · Cited by 13
Self-citation
Research works printed but not linked: 1
- Centers for Disease Control and Prevention. Diabetes Report Card 2012 2012 Atlanta, GA U.S. Department of Health and Human Services
Cited by
High-performance medicine: the convergence of human and artificial intelligence
Topol, E. J. (2019) · Nature Medicine · doi:10.1038/s41591-018-0300-7 · Cited by 10,450
“…review (many of which are summarized in Table 1), the only prospective validation studies in a real-world setting have been for diabetic retinopathy 31,32 , detection of wrist fractures in the emergy room setting 33 , histologic breast cancer metastases 34,35 , very small colonic polyps 36,37 ,…”
BackgroundMethodKey challenges for delivering clinical impact with artificial intelligence
Kelly, C. J., Karthikesalingam, A., Suleyman, M., Corrado, G., & King, D. (2019) · BMC Medicine · doi:10.1186/s12916-019-1426-2 · Cited by 3,136
“The limited number of prospective studies to date include diabetic retinopathy grading [48 – 50], detection of breast cancer metastases in sentinel lymph node biopsies [51, 52], wrist fracture detection [53], colonic polyp detection [28, 54], and detection of congenital cataracts [55].”
BackgroundArtificial intelligence in healthcare
Yu, K.-H., Beam, A. L., & Kohane, I. S. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0305-z · Cited by 2,817
Resistance to Medical Artificial Intelligence
Longoni, C., Bonezzi, A., & Morewedge, C. K. (2019) · Journal of Consumer Research · doi:10.1093/jcr/ucz013 · Cited by 2,015
Precision medicine, AI, and the future of personalized health care
Johnson, K. B., Wei, W., Weeraratne, D., Frisse, M. E., Misulis, K., Rhee, K., Zhao, J., & Snowdon, J. L. (2021) · Clinical and Translational Science · doi:10.1111/cts.12884 · Cited by 1,854
“Such prospective studies highlighted the importance of validating the AI models in the clinical environment and considering an iteration loop—that collects users’ feedback as new input for learning and system improvement 96 before applying the AI system widely.”
Background
Metadata
- Authors
- Abràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C.
- Affiliations
- University of Iowa (US)
- University of North Carolina at Charlotte (US)
- Emmes (United States) (US)
- Corresponding author
- Abràmoff, Michael D.
- Venue
- npj Digital Medicine
- Published
- 2018-08-28
- Volume
- 1
- Issue
- 1
- Pages
- 39-39
- ISSN
- 2398-6352 (ISSN-L)
- PMC
- PMC6550188
- OpenAlex
- W2888424632
- Cited by
- 1,638
- References
- 61
- Citations by year
- 2026: 332 · 2025: 276 · 2024: 226 · 2023: 193 · 2022: 172 · 2021: 183 · 2020: 173 · 2019: 73 · 2018: 10
- FWCI
- 75.83
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- npj Digital Medicine (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- IDx LLC, Coralville, IA
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- diabetic retinopathy, diabetic macular edema, autonomous AI systems, FDA approval, primary care, fundus photography, optical coherence tomography, sensitivity and specificity, imageability, blindness prevention, diabetes mellitus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.