Wearable microfluidic biosensors with haptic feedback for continuous monitoring of hydration biomarkers in workers

Open access

Abstract

Real-time monitoring of hydration biomarkers in tandem with biophysical markers can offer valuable physiological insights about heat stress and related thermoregulatory response. These metrics have been challenging to achieve with wearable sensors. Here we present a closed-loop electrochemical/biophysical wearable sensing device and algorithms that directly measure whole-body sweat loss, sweating rate, sodium concentration, and sodium loss with electrode arrays embedded in a microfluidic channel. The device contains two temperature sensors for skin temperature and thermal flux recordings, and an accelerometer for real-time monitoring of activity level. An onboard haptic module enables vibratory feedback cues to the wearer once critical sweat loss thresholds are reached. Data is stored onboard in memory and autonomously transmitted via Bluetooth to a smartphone and cloud portal. Field studies conducted in physically demanding activities demonstrate the key capabilities of this platform to inform hydration interventions in highly challenging real-world settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41746-025-01466-9

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 EBS device showing electrochemical sensors, biophysical sensors, associated electronics, and microfluidics substrate. a Schematic drawing of the EBS device module and exploded view of the underlying microfluidic substrate, including the microfluidic channel, electrode circuitry, and multiple capping and adhesive layers. b Exploded view of electronic module showing key components including battery, PCB, microcontroller, accelerometer, two temperature sensors (for thermal flux measurements), haptic motor (for vibration notifications), and pin interconnects (for electrical coupling between microfluidic substrate and module). c Schematic drawing of the microfluidic channel and electrode circuitry layers. d Photograph of fully assembled EBS device with module mechanically clipped into the microfluidic substrate and adhered to the biceps/triceps region. e Representative example of a subject running on a treadmill while wearing the EBS device on their biceps/triceps region underneath a PPE suit.
Fig. 1 EBS device showing electrochemical sensors, biophysical sensors, associated electronics, and microfluidics substrate. a Schematic drawing of the EBS device module and exploded view of the underlying microfluidic substrate, including the microfluidic channel, electrode circuitry, and multiple capping and adhesive layers. b Exploded view of electronic module showing key components including battery, PCB, microcontroller, accelerometer, two temperature sensors (for thermal flux measurements), haptic motor (for vibration notifications), and pin interconnects (for electrical coupling between microfluidic substrate and module). c Schematic drawing of the microfluidic channel and electrode circuitry layers. d Photograph of fully assembled EBS device with module mechanically clipped into the microfluidic substrate and adhered to the biceps/triceps region. e Representative example of a subject running on a treadmill while wearing the EBS device on their biceps/triceps region underneath a PPE suit.CC BY-NC-ND · PubMed Central
Fig. 2 Benchtop calibration of electrochemical sodium sensor, volume and flow sensor, and temperature sensors. a Photograph of benchtop stage used to perfuse fluid through the EBS device at controlled salt concentrations, temperatures, and flow speeds. The EBS device was housed in an incubator with controlled temperature during these tests with polystyrene tubing connecting to an external syringe pump. b Fluid volume (top) and sodium concentration (bottom) time series data resulting from benchtop perfusion and EBS device measurements. The EBS device measured fluid fill rate (nominally 1.0 μL/min) and concentration (nominally 33.4 mM NaCl solution) during perfusion. c Measured fluid volume capture vs known fluid volume perfused across a range of physiological volumes indicative of sweat excretion (n = 3358 measurements from n = 48 tests; R2 = 1.0). d Correlation of measured voltage readings vs known sodium concentrations (mM) at 3 different temperatures: 40 °C in red (n = 70; R2 = 0.98), 32 °C in green (n = 71; R2 = 0.97), 20 °C in blue (n = 77; R2 = 0.94). e EBS device measured sodium concentrations with temperature correction applied vs known sodium concentration collected at two temperatures in the incubator. Results indicate that the EBS device effectively compensated for the temperature effects (n = 48; R2 = 0.95). Gray shaded region indicates the 95% confidence interval (C.I.).
Fig. 2 Benchtop calibration of electrochemical sodium sensor, volume and flow sensor, and temperature sensors. a Photograph of benchtop stage used to perfuse fluid through the EBS device at controlled salt concentrations, temperatures, and flow speeds. The EBS device was housed in an incubator with controlled temperature during these tests with polystyrene tubing connecting to an external syringe pump. b Fluid volume (top) and sodium concentration (bottom) time series data resulting from benchtop perfusion and EBS device measurements. The EBS device measured fluid fill rate (nominally 1.0 μL/min) and concentration (nominally 33.4 mM NaCl solution) during perfusion. c Measured fluid volume capture vs known fluid volume perfused across a range of physiological volumes indicative of sweat excretion (n = 3358 measurements from n = 48 tests; R2 = 1.0). d Correlation of measured voltage readings vs known sodium concentrations (mM) at 3 different temperatures: 40 °C in red (n = 70; R2 = 0.98), 32 °C in green (n = 71; R2 = 0.97), 20 °C in blue (n = 77; R2 = 0.94). e EBS device measured sodium concentrations with temperature correction applied vs known sodium concentration collected at two temperatures in the incubator. Results indicate that the EBS device effectively compensated for the temperature effects (n = 48; R2 = 0.95). Gray shaded region indicates the 95% confidence interval (C.I.).CC BY-NC-ND · PubMed Central
Fig. 3 On-body time series data of sweat and sodium loss, activity level, and skin temperature. a Time series of fluid deficit (blue line) and sodium deficit (purple line) over a 9-h period. Interactions between wearer and EBS device such as logging intake (green water bottle symbol), EBS device triggering a haptic notification for sweat loss (blue vibrating module icon), and EBS device triggering a haptic notification for significant net fluid deficit (red alarm icon) are automatically logged. Shading indicates regions of net fluid surplus (blue) and deficit (red). Upward step changes are present whenever the user manually logged intake. b Time-aligned measured activity score as measured by EBS device (red) and metabolic rate (kCal/min) as measured by room calorimeter (black) during typical workplace activity levels (inclined walking while wearing a weighted vest). Shading indicates the type of activity performed by the wearer. Unshaded regions represent times when the wearer stood in place to rest. The activity score reflects changes in exertion as determined both observationally and by metabolic rate. c Time-aligned skin temperature as measured by EBS device (red) and by the adjacent iButton device (black). Changes in skin temperature are reflected in both recordings. d The temperature difference measured by the EBS device’s two temperature sensors closely track heat flux measured by a heat flux sensor. The temperature difference data was filtered with a 10-point median filter to reduce noise.
Fig. 3 On-body time series data of sweat and sodium loss, activity level, and skin temperature. a Time series of fluid deficit (blue line) and sodium deficit (purple line) over a 9-h period. Interactions between wearer and EBS device such as logging intake (green water bottle symbol), EBS device triggering a haptic notification for sweat loss (blue vibrating module icon), and EBS device triggering a haptic notification for significant net fluid deficit (red alarm icon) are automatically logged. Shading indicates regions of net fluid surplus (blue) and deficit (red). Upward step changes are present whenever the user manually logged intake. b Time-aligned measured activity score as measured by EBS device (red) and metabolic rate (kCal/min) as measured by room calorimeter (black) during typical workplace activity levels (inclined walking while wearing a weighted vest). Shading indicates the type of activity performed by the wearer. Unshaded regions represent times when the wearer stood in place to rest. The activity score reflects changes in exertion as determined both observationally and by metabolic rate. c Time-aligned skin temperature as measured by EBS device (red) and by the adjacent iButton device (black). Changes in skin temperature are reflected in both recordings. d The temperature difference measured by the EBS device’s two temperature sensors closely track heat flux measured by a heat flux sensor. The temperature difference data was filtered with a 10-point median filter to reduce noise.CC BY-NC-ND · PubMed Central
Fig. 4 Population correlations of on-body data for sodium concentration, local sweat volume, and whole-body sweating rate. a Correlation of sodium concentration as measured by EBS with the ground truth as measured by the Horiba sodium electrode. The gray area represents the 95% confidence interval (C.I.) of the best fit (black line), which includes the line of unity. b Correlation of local sweat volume normalized by collection area as measured by EBS device with that measured by the net weight change of a Tegaderm pad. c Correlation of whole-body sweating rate (L/min) as measured by EBS device with the net weight loss rate of the subject pre- and post-exercise. The line of unity falls within the 95% CI.
Fig. 4 Population correlations of on-body data for sodium concentration, local sweat volume, and whole-body sweating rate. a Correlation of sodium concentration as measured by EBS with the ground truth as measured by the Horiba sodium electrode. The gray area represents the 95% confidence interval (C.I.) of the best fit (black line), which includes the line of unity. b Correlation of local sweat volume normalized by collection area as measured by EBS device with that measured by the net weight change of a Tegaderm pad. c Correlation of whole-body sweating rate (L/min) as measured by EBS device with the net weight loss rate of the subject pre- and post-exercise. The line of unity falls within the 95% CI.CC BY-NC-ND · PubMed Central
Fig. 5 Example of supervisor view of aggregated site data in cloud portal. Data from each individual’s mobile application is transmitted to a cloud portal. Population data in the cloud (e.g. heat index, average water loss, average water intake, average sodium loss, skin temperature, activity level, and fluid intake vs water loss) is aggregated and summarized for view by health and safety managers, industrial hygienists or medical personnel who review it to gain insights, anticipate risks, and identify longitudinal patterns. Managers and caregivers are empowered to communicate insights or updates to hydration safety protocols back to industrial workers.
Fig. 5 Example of supervisor view of aggregated site data in cloud portal. Data from each individual’s mobile application is transmitted to a cloud portal. Population data in the cloud (e.g. heat index, average water loss, average water intake, average sodium loss, skin temperature, activity level, and fluid intake vs water loss) is aggregated and summarized for view by health and safety managers, industrial hygienists or medical personnel who review it to gain insights, anticipate risks, and identify longitudinal patterns. Managers and caregivers are empowered to communicate insights or updates to hydration safety protocols back to industrial workers.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 48 references

Research works printed but not linked: 1

  1. Stone, J. et al. Report of the Small Business Advocacy Review Panel on OSHA’s Potential Standard for Heat Injury and Illness Prevention in Outdoor and Indoor Work Settings (U.S. Department of Labor, Occupational Safety and Health Administration Website, 2023).

Cited by

See all 44

Metadata

Authors
Spinelli, J. C., Suleski, B. J., Wright, D. E., Grow, J. L., Fagans, G. R., Buckley, M. J., Yang, D. S., Yang, K., Beil, S. M., Wallace, J. C., DiZoglio, T. S., Model, J. B., Love, S., Macintosh, D. E., Scarth, A. P., Marrapode, M. T., Serviente, C., Avila, R., Alahmad, B. K., Busa, M. A., Wright, J. A., Li, W., Casa, D. J., Rogers, J. A., Lee, S. P., Ghaffari, R., & Aranyosi, A. J.
Affiliations
  • Northwestern University (US)
  • University of Massachusetts Amherst (US)
  • Rice University (US)
  • Harvard University (US)
  • University of Connecticut (US)
Corresponding author
  • Rogers, John A.
  • Lee, Stephen P.
  • Ghaffari, Roozbeh
  • Aranyosi, Alexander J.
Venue
npj Digital Medicine
Published
2025-02-01
Volume
8
Issue
1
Pages
76-76
ISSN
2398-6352 (ISSN-L)
OpenAlex
W4407058372
Cited by
44
References
48
Citations by year
2026: 31 · 2025: 13
FWCI
10.70
Type
journal article
Language
en
Open access
Licence
Locations
  • npj Digital Medicine (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • Northwestern University
  • University of Massachusetts Amherst
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
wearable sensors, microfluidic biosensor, haptic feedback, hydration biomarkers, sweat loss, sweat rate, sweat sodium concentration, sodium loss, heat stress, thermoregulation, skin temperature, heat flux, accelerometer, closed-loop monitoring, occupational workers, Bluetooth data transmission

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wearable microfluidic biosensors with haptic feedback for continuous monitoring of hydration biomarkers in workers. https://app.cochat.ai/papers/10.1038/s41746-025-01466-9
The paper
Spinelli, J. C., Suleski, B. J., Wright, D. E., Grow, J. L., Fagans, G. R., Buckley, M. J., Yang, D. S., Yang, K., Beil, S. M., Wallace, J. C., DiZoglio, T. S., Model, J. B., Love, S., Macintosh, D. E., Scarth, A. P., Marrapode, M. T., Serviente, C., Avila, R., Alahmad, B. K., . . . Aranyosi, A. J. (2025). Wearable microfluidic biosensors with haptic feedback for continuous monitoring of hydration biomarkers in workers. npj Digital Medicine. https://doi.org/10.1038/s41746-025-01466-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.