Three-dimensional multilayer concentric bipolar electrodes restrict spatial activation in optic nerve stimulation
Open accessAbstract
Objective. Intraneural nerve interfaces often operate in a monopolar configuration with a common and distant ground electrode. This configuration leads to a wide spreading of the electric field. Therefore, this approach is suboptimal for intraneural nerve interfaces when selective stimulation is required. Approach. We designed a multilayer electrode array embedding three-dimensional concentric bipolar (CB) electrodes. First, we validated the higher stimulation selectivity of this new electrode array compared to classical monopolar stimulation using simulations. Next, we compared them in-vivo by intraneural stimulation of the rabbit optic nerve and recording evoked potentials in the primary visual cortex. Main results. Simulations showed that three-dimensional CB electrodes provide a high localisation of the electric field in the tissue so that electrodes are electrically independent even for high electrode density. Experiments in-vivo highlighted that this configuration restricts spatial activation in the visual cortex due to the fewer fibres activated by the electric stimulus in the nerve. Significance. Highly focused electric stimulation is crucial to achieving high selectivity in fibre activation. The multilayer array embedding three-dimensional CB electrodes improves selectivity in optic nerve stimulation. This approach is suitable for other neural applications, including bioelectronic medicine.
AI snapshot
Written from the paper’s full text.
TL;DR
A multilayer intraneural array with three-dimensional concentric bipolar (CB) electrodes was designed to restrict spatial activation during optic nerve stimulation. Simulations and in vivo rabbit experiments showed that 3D multilayer CB stimulation activates fewer optic nerve fibres and produces more localized visual cortex responses than monopolar stimulation.
Key findings
- FEA simulations showed that 3D multilayer CB electrodes localize the electric field and remain electrically independent even at high electrode density, whereas monopolar electrodes showed wide field spread, potential summation, and cross-talk.
- Hybrid FEA-NEURON modelling found that a 3D multilayer CB electrode activated about 40 times fewer fibres than a monopolar electrode; at similar total activation probability across the nerve section (4.8% difference), 60% of the CB cumulative distribution was activated at probability >0.9 versus 40% for monopolar, and the total activated area was 30.4% larger for monopolar.
- In vivo, EEP peak-to-peak amplitudes rose monotonically with current; responses began above zero at 150 µA for monopolar and 250 µA for 3D multilayer CB, with significantly different linear regression slopes (monopolar slope = 0.0524, R² = 0.9140; CB slope = 0.0192, R² = 0.8488; p < 0.0001).
- The 3D multilayer CB configuration produced fewer responsive ECoG electrodes and a smaller normalized weighted distance across current amplitudes; from 1500 µA, all eight stimulating electrodes per rabbit showed a significant difference between monopolar and CB. Return coefficient α linearly modulated activated fibre number, and increasing pulses in a train increased EEP amplitude.
Methods
- FEA was performed in COMSOL Multiphysics 5.3 with a 5 × 5 electrode array (80 µm diameter, 100 µm pitch) in a saline box; a hybrid FEA-NEURON model of the rabbit optic nerve used McNeal’s cable model and activation probability maps across current amplitudes from 2 to 2000 µA.
- A Flat-OpticSELINE array with eight 3D multilayer CB electrodes (40 µm diameter, 160 µm pitch) was microfabricated, coated with platinum black, and characterized by EIS and CV.
- In vivo experiments used two female Chinchilla Bastard rabbits; the array was inserted transversally into the optic nerve, EEPs were recorded from V1 with a 32-electrode ECoG array, and stimulation used biphasic pulses at 10–2000 µA, with 52 conditions and 416 stimuli delivered randomly, repeated 30 times in rabbit 1 and 15 times in rabbit 2. Analysis used PCA and Gaussian mixture model clustering, EEP peak-to-peak amplitudes, responsive electrode counts, and normalized weighted distance.
Limitations
- Stated: measuring fibre activation directly in the optic nerve remains an open challenge due to limited space in the intracranial segment; the authors instead inferred activation from visual cortex EEPs.
- Stated: the ECoG array’s signal-to-noise ratio and spatial resolution may not have been sufficient to record EEPs from a small number of activated fibres at low currents in the CB configuration; future work should use higher-resolution recording or imaging.
- Stated: central and return electrode areas were almost identical, so future work could investigate different surface areas to optimize stimulation efficiency. Evident from the text: the in vivo validation used only two rabbits, making it a feasibility study with limited generalizability.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
0 of 23 cited sources checked · 0 supported · 0 flagged
- Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 6
FEA simulations confirmed that the local return electrode in the 3D multilayer concentric bipolar configuration localised the electric field.
“FEA simulations confirmed that the local return electrode localised the electric field (figures 1(h) and (i)).”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 6
In FEA simulations with only one electrode active, the electric potential profile has a Gaussian shape for both monopolar and 3D multilayer concentric bipolar configurations.
“When only one electrode is active, the electric potential profile obtained by FEA simulations has a Gaussian shape for both the monopolar configuration (figure 2(b), left) and the 3D multilayer CB configuration (figure 2(c), left).”
Quote in the paperNot a substantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 6
When all 25 electrodes are activated in monopolar configuration, the electric potential profile is widened and increased in amplitude due to potential summation.
“When all the 25 electrodes are activated, the electric potential profile obtained for the monopolar configuration (figure 2(b), middle) is widened and increased in amplitude due to potential summation.”
Quote in the paperSubstantial claim - Findingown data§ 4. Discussion · p. 14
The response spread increased with increasing current amplitudes for both monopolar and 3D multilayer CB configurations.
“We showed it increased with increasing current amplitudes for both monopolar, as presented in [24], and 3D multilayer CB configurations.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [24] Wong, 2016, Spectral distribution of local field potential responses to electrical stimulation of the retina, J. Neural Eng. source
Not checked in the free run.
- Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 8
The 3D multilayer CB configuration contains a higher proportion of high activation probabilities than the monopolar configuration.
“The 3D multilayer CB configuration (red line) contains a higher proportion of high activation probabilities than the monopolar configuration (black line)”
Quote in the paperSubstantial claim
- Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 8
The monopolar configuration activates a more diffuse area.
“the monopolar configuration activates a more diffuse area.”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 8
When the same averaged number of fibres are activated, the 3D multilayer CB configuration activates fibres (both small and large) in a smaller area close to the electrode.
“when the same averaged number of fibres are activated (similar total activation probability across the entire nerve section), the 3D multilayer CB configuration activates fibres (both small and large) in a smaller area close to the electrode.”
Quote in the paperSubstantial claim- Rests on an assumption: Similar total activation probability across the entire nerve section corresponds to a similar number of activated fibres.
- Findingown data§ 4. Discussion · p. 14
The current threshold for cortical activation with the 3D multilayer CB configuration was higher than for monopolar.
“the current threshold for cortical activation with the 3D multilayer CB configuration was higher than for monopolar.”
Quote in the paperSubstantial claim - Findingreasoning§ 3.1. Hybrid FEA-NEURON modelling · p. 7
The activated area has a 'three-leaf clover' shape for 3D multilayer CB electrodes.
“the activated area has a 'three-leaf clover' shape for 3D multilayer CB electrodes.”
Quote in the paperNot a substantial claim - Findingown data§ 3.3. Electrophysiological validation in-vivo · p. 10
From 1500 μA, all stimulating electrodes (eight per rabbit) showed a significant difference between monopolar and 3D multilayer CB configurations.
“While from 1500 µ A, all the stimulating electrodes (eight per rabbit) showed a significant difference between monopolar ( α = 1) and the 3D multilayer CB ( α = 0.5) configurations.”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 8
The two compared current amplitudes had similar total activation probability across the entire nerve section (4.8% percentage change).
“we compared two current amplitudes having a similar total activation probability across the entire nerve section (4.8% percentage change between the two configurations)”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 7
The hybrid FEA-NEURON model showed that the nerve area activated by one electrode in the 3D multilayer concentric bipolar configuration with α = 0.5 is more confined than in the monopolar configuration.
“The model showed that the nerve area activated by one electrode in the 3D multilayer CB configuration ( α = 0.5) is more confined than the monopolar configuration (figure 3(a)).”
Quote in the paperSubstantial claim - Findingnone given§ 3.1. Hybrid FEA-NEURON modelling · p. 7
The electric potential due to the concentric return electrode blocks the activation of the nerve below the plane of the electrode array.
“electric potential due to the concentric return electrode blocks the activation of the nerve below the plane of the electrode array.”
Quote in the paperSubstantial claim - Findingown data§ 3.3. Electrophysiological validation in-vivo · p. 10
The mean EEP peak-to-peak amplitudes for all recording and stimulating electrodes in both conditions showed a monotonic growth as a function of the current amplitude.
“The mean EEP peak-to-peak amplitudes for all the recording and stimulating electrodes in both conditions, monopolar ( α = 1) and 3D multilayer CB ( α = 0.5), showed a monotonic growth as a function of the current amplitude (figure 7(a)).”
Quote in the paperNot a substantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 7
In monopolar configuration, the activated area is circular around the central electrode.
“The activated area is circular around the central electrode in the monopolar configuration.”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 6
In 3D multilayer concentric bipolar configuration, the electric potential induced by each electrode can be sharply discriminated at every distance.
“Conversely, the 3D multilayer CB configuration allows sharp discrimination of the electric potential induced by each electrode at every distance (figure 2(c), middle).”
Quote in the paperSubstantial claim - Findingown data§ 3.3. Electrophysiological validation in-vivo · p. 10
The normalised weighted distance was smaller at every current amplitude for the 3D multilayer CB configuration compared to the monopolar configuration.
“the normalised weighted distance was smaller, at every current amplitude, for the 3D multilayer CB configuration (figure 8(c)).”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 6
In 3D multilayer concentric bipolar configuration, switching off the central electrode produces a maximal contrast in the electric potential drop.
“Also, we observed a maximal contrast in the electric potential drop when the central electrode is switched off (figure 2(c), right).”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 8
The current amplitude was 20 μA for the monopolar configuration and 2000 μA for the 3D multilayer CB configuration to achieve similar total activation probability.
“The amplitude is 20 µ A for the monopolar configuration and 2000 µ A for the 3D multilayer CB (figure 4(a)).”
Quote in the paperSubstantial claim - Findingown data§ Abstract · p. 2
In vivo experiments highlighted that the 3D multilayer concentric bipolar configuration restricts spatial activation in the visual cortex due to fewer fibres activated by the electric stimulus in the nerve.
“Experiments in-vivo highlighted that this configuration restricts spatial activation in the visual cortex due to the fewer fibres activated by the electric stimulus in the nerve.”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 6
In monopolar configuration with all electrodes active, the contribution of each electrode is barely distinguishable only at 10 μm from the electrode surface, and further away the electric potentials fuse.
“The contribution of each electrode is barely distinguishable only at a distance of 10 µ m from the electrode surface. Further away, the electric potential fuse.”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 7
FEA simulations showed that the 3D multilayer concentric bipolar configuration focuses the electric potential laterally and vertically.
“FEA simulations showed that the 3D multilayer CB configuration focuses the electric potential laterally and vertically.”
Quote in the paperSubstantial claim - Findingown data§ 4. Discussion · p. 14
On average, the extent of spatial spread was significantly lower for the 3D multilayer CB configuration.
“on average, the extent of this spatial spread was significantly lower for the 3D multilayer CB configuration.”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 7
The shape of the activated area differs between the 3D multilayer concentric bipolar and monopolar configurations.
“Besides the size of the activated area, also the shape is different between the two conditions.”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 6
In monopolar configuration, switching off the central electrode leaves the electric potential blurred due to electrode cross-talk.
“When switching off the central electrode, the electric potential in monopolar configuration remains blurred due to the electrode cross-talk (figure 2(b), right).”
Quote in the paperSubstantial claim - Findingown data§ 3.3. Electrophysiological validation in-vivo · p. 10
Fewer recording electrodes had a significant response in the 3D multilayer CB configuration compared to the monopolar configuration.
“fewer recording electrodes had a significant response in the 3D multilayer CB configuration compared to the monopolar configuration (figure 8(b)).”
Quote in the paperSubstantial claim - Findingown data§ 3.3. Electrophysiological validation in-vivo · p. 10
The evoked cortical response remained more localised when the 3D multilayer CB configuration was used instead of the monopolar configuration.
“it remained more localised when the 3D multilayer CB configuration was used instead of the monopolar configuration (figure 8(a)).”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 7
For 3D multilayer CB electrodes, the return coefficient α linearly modulates the number of activated fibres.
“for 3D multilayer CB electrodes, we found that the return coefficient α linearly modulates the number of activated fibres (figure 3(d)).”
Quote in the paperSubstantial claim - Findingown data§ 3.3. Electrophysiological validation in-vivo · p. 10
The evoked cortical response spread across more recording channels for increasing current amplitudes.
“the evoked cortical response spread across more recording channels for increasing current amplitudes.”
Quote in the paperNot a substantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 7
Three-dimensional multilayer CB electrodes provide lateral selectivity of the stimulated area even at high current amplitudes.
“Three-dimensional multilayer CB electrodes provide lateral selectivity of the stimulated area even at high current amplitudes.”
Quote in the paperSubstantial claim - Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 7
A 3D multilayer CB electrode activated about 40 times fewer fibres than a monopolar electrode.
“a 3D multilayer CB electrode activated about 40 times fewer fibres than a monopolar electrode (figures 3(b) and (c)).”
- Also stated in: § 4. Discussion · p. 13 · plain
“The results showed a substantial reduction in fibres activated with the 3D multilayer CB electrode.”
Quote in the paperSubstantial claim - Also stated in: § 4. Discussion · p. 13 · plain
- Interpretationown data§ 1. Introduction · p. 3
The array of 3D multilayer concentric bipolar electrodes proposed here improves the selectivity of intraneural stimulation.
“The array of 3D multilayer CB electrodes proposed here improves the selectivity of the intraneural stimulation.”
- Also stated in: § Abstract · p. 2 · plain
“The multilayer array embedding three-dimensional CB electrodes improves selectivity in optic nerve stimulation.”
Quote in the paperSubstantial claim- Rests on an assumption: Highly focused electric stimulation is crucial to achieving high selectivity in fibre activation.
- Also stated in: § Abstract · p. 2 · plain
- Premisecitation§ 1. Introduction · p. 3
Most clinical neural interfaces function in a monopolar configuration with a common and distant return ground placed several millimetres away.
“Most clinical neural interfaces function in a monopolar configuration with a common and distant return ground placed several millimetres away [9-12].”
Quote in the paperSubstantial claim0 of 4 sources checked- cites [9] Luo, 2016, The Argus® II retinal prosthesis system, Prog. Retin. Eye Res. source
Not checked in the free run.
- cites [10] Ayton, 2014, First-in-human trial of a novel suprachoroidal retinal prosthesis ed K Mori, PLoS One source
Not checked in the free run.
- cites [11] Stieglitz, 2012, Development of a neurotechnological system for relieving phantom limb pain using transverse intrafascicular electrodes (TIME), Biomed. Tech. Eng. source
Not checked in the free run.
- cites [12] Zrenner, 2011, Subretinal electronic chips allow blind patients to read letters and combine them to words, Proc. Biol. Sci. source
Not checked in the free run.
- Interpretationreasoning§ 3.1. Hybrid FEA-NEURON modelling · p. 7
The 'three-leaf clover' shape is caused by the anodic activation from the concentric return electrode.
“This shape is caused by the anodic activation from the concentric return electrode.”
Quote in the paperNot a substantial claim - Premisecitation§ 4. Discussion · p. 13
Local return stimulation can be used to restrict the electrical activation of neurons by shaping the electric field.
“These findings are consistent with previous evidence that local return stimulation can be used to restrict the electrical activation of neurons by shaping the electric field [16, 25].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [16] Spencer, 2016, Spatial restriction of neural activation using focused multipolar stimulation with a retinal prosthesis, Invest. Ophthalmol. Vis. Sci. source
Not checked in the free run.
- cites [25] Flores, 2016, Optimization of return electrodes in neurostimulating arrays, J. Neural Eng. source
Not checked in the free run.
- Interpretationreasoning§ 4. Discussion · p. 13
A 3D multilayer CB electrode provides a stimulation configuration that strongly reduces crosstalk between electrodes.
“A 3D multilayer CB electrode provides a stimulation configuration that strongly reduces crosstalk between electrodes.”
Quote in the paperSubstantial claim - Premisereasoning§ 4. Discussion · p. 13
Complex stimulation patterns at high resolution cannot be easily obtained with QMP since for every stimulating electrode, the six surrounding electrodes are used as a return.
“complex stimulation patterns at high resolution cannot be easily obtained since, for every stimulating electrode, the six surrounding electrodes are used as a return.”
Quote in the paperSubstantial claim - Interpretationreasoning§ 4. Discussion · p. 13
A lower peak-to-peak amplitude of the EEPs with the 3D multilayer CB configuration is associated with fewer fibres activated in the optic nerve.
“we could infer that a lower peak-to-peak amplitude of the EEPs with the 3D multilayer CB configuration is associated with fewer fibres activated in the optic nerve.”
Quote in the paperSubstantial claim- Rests on an assumption: The peak-to-peak amplitude of EEPs recorded in V1 is a valid proxy for the number of fibres activated in the optic nerve.
- Interpretationown data§ 3.3. Electrophysiological validation in-vivo · p. 12
This result confirms the prediction of the hybrid FEA-NEURON model.
“This result confirms the prediction of the hybrid FEA-NEURON model (figure 3(d)).”
Quote in the paperSubstantial claim - Interpretationreasoning§ 3.1. Hybrid FEA-NEURON modelling · p. 7
In 3D multilayer concentric bipolar configuration, the electric potential decreases substantially with distance from the electrode surface due to the lateral shunting effect of the concentric return electrode.
“The electric potential decreases substantially with the distance from the electrode surface. This decrease is due to the lateral shunting effect of the concentric return electrode.”
Quote in the paperSubstantial claim - Premisecitation§ 4. Discussion · p. 13
Punctual features appeared to be not informative enough for prediction models.
“we already showed that punctual features appeared to be not informative enough for prediction models [19].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [19] Gaillet, 2021, A machine-learning algorithm correctly classifies cortical evoked potentials from both visual stimulation and electrical stimulation of the optic nerve, J. Neural Eng. source
Not checked in the free run.
- Interpretationcitation§ 3.3. Electrophysiological validation in-vivo · p. 12
This result confirms the previous finding that cortical activation can be modulated in amplitude by increasing the number of pulses instead of changing the current intensity.
“This result confirms the previous finding that the cortical activation can be modulated in amplitude by increasing the number of pulses instead of changing the current intensity [18].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [18] Gaillet, 2020, Spatially selective activation of the visual cortex via intraneural stimulation of the optic nerve, Nat. Biomed. Eng. source
Not checked in the free run.
- Interpretationown data§ 3.1. Hybrid FEA-NEURON modelling · p. 6
In 3D multilayer concentric bipolar configuration, electrodes are electrically independent even for high electrode density.
“In this condition, the electrodes are electrically independent, even for high electrode density.”
- Also stated in: § Abstract · p. 2 · plain
“Simulations showed that three-dimensional CB electrodes provide a high localisation of the electric field in the tissue so that electrodes are electrically independent even for high electrode density.”
Quote in the paperSubstantial claim - Also stated in: § Abstract · p. 2 · plain
- Premisecitation§ 1. Introduction · p. 2
Increasing electrode density increases the risk of stimulation cross-talk and current summation when neighbouring electrodes are activated simultaneously.
“Increasing the electrode density increases the risk of having a stimulation cross-talk and current summation when neighbouring electrodes are activated simultaneously.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [7] Dobelle, 1974, Phosphenes produced by electrical stimulation of human occipital cortex, and their application to the development of a prosthesis for the blind, J. Physiol. source
Not checked in the free run.
- cites [8] Schmidt, 1996, Feasibility of a visual prosthesis for the blind based on intracortical micro stimulation of the visual cortex, Brain source
Not checked in the free run.
- Interpretationown data§ 3.1. Hybrid FEA-NEURON modelling · p. 7
In 3D multilayer concentric bipolar configuration, the localisation of the electric potential due to the concentric return electrode blocks activation of the nerve below the plane of the electrode array.
“In the 3D multilayer CB configuration, the localisation of the electric potential due to the concentric return electrode blocks the activation of the nerve below the plane of the electrode array.”
Quote in the paperSubstantial claim - Premisereasoning§ 1. Introduction · p. 3
The configuration used for electrical stimulation plays a significant role in the balance between electrode density and independence.
“The configuration used for electrical stimulation plays a significant role in this balance.”
Quote in the paperSubstantial claim - Interpretationreasoning§ 3.1. Hybrid FEA-NEURON modelling · p. 6
In monopolar configuration, electrodes cannot be considered electrically independent unless at a much lower density.
“Thus, the electrodes in monopolar configuration cannot be considered electrically independent unless for a much lower density.”
Quote in the paperSubstantial claim - Interpretationown data§ 3.1. Hybrid FEA-NEURON modelling · p. 7
At higher current amplitudes in monopolar configuration, the activation area becomes more symmetric because of the large spreading of the electric field.
“At higher current amplitudes, the activation area becomes more symmetric because of the large spreading of the electric field.”
Quote in the paperNot a substantial claim
- May combine two claims. 17
- The quote only partly states this claim. 2
- Classified as probably not a substantial claim. 14
May combine two claims.
Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 6In monopolar configuration, lateral spreading of the electric potential increases with distance from the electrode, whereas in 3D multilayer concentric bipolar configuration it remains sharp even 100 μm away.
“However, for the monopolar configuration, the lateral spreading of the electric potential increases as the distance from the electrode increase (figure 2(b), left), while it remains sharp for the 3D multilayer CB configuration (figure 2(c), left) even on a plane located 100 µ maway from the electrode.”
Quote in the paperSubstantial claimMay combine two claims.
Findingcitation§ 4. Discussion · p. 14The 3D multilayer CB configuration activated smaller EEPs and a smaller area on the cortex than the monopolar electrodes.
“the 3D multilayer CB configuration activated smaller EEPs and a smaller area on the cortex than the monopolar electrodes.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [33] Wong, 2009, Focal activation of the feline retina via a suprachoroidal electrode array, Vision Res. source
Not checked in the free run.
May combine two claims. The quote only partly states this claim.
Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 8The total activated area is larger by a 30.4% percentage increase in the monopolar configuration compared to the 3D multilayer CB configuration, despite similar total activation probability.
“the total activated area (black contour in the maps) is larger by a 30.4% percentage increase in the monopolar configuration.”
Quote in the paperSubstantial claimThe quote only partly states this claim.
Findingown data§ 3.3. Electrophysiological validation in-vivo · p. 10From 150 μA, an increasing number of stimulating electrodes elicited a significantly different averaged EEP peak-to-peak amplitude between monopolar and 3D multilayer CB configurations.
“From 150 µ A, an increasing number of stimulating electrodes appeared to elicit a significantly different EEP.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown data§ 3.3. Electrophysiological validation in-vivo · p. 10EEP peak-to-peak amplitudes became higher than zero starting from a current amplitude of 150 μA for the monopolar configuration and 250 μA for the 3D multilayer CB.
“EEP peak-to-peak amplitudes became higher than zero, starting from a current amplitude of 150 µ A for the monopolar configuration and 250 µ A for the 3D multilayer CB.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
Findingcitation§ 4. Discussion · p. 13The first two principal components represented more than 95% of the variance.
“We selected the first two principal components representing more than 95% of the variance [31].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [31] Jolliffe, 2002 source
Not checked in the free run.
May combine two claims.
Findingown data§ 3.1. Hybrid FEA-NEURON modelling · p. 8In the 3D multilayer CB configuration, 60% of the cumulative distribution is activated at an activation probability higher than 0.9, while only 40% in the monopolar configuration.
“in the 3Dmultilayer CB configuration, 60% of the cumulative distribution is activated at an activation probability higher than 0.9 (dashed grey line), while only 40% in the monopolar configuration.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown data§ 4. Discussion · p. 14Modulation of the return coefficient α could increase the number of fibres activated and the EEP peak-to-peak amplitude.
“the modulation of the return coefficient α could increase the number of fibres activated and the EEP peak-to-peak amplitude.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
Premisecitation§ 1. Introduction · p. 3Selective activation of a few optic nerve fibres by each electrode was still an open challenge.
“However, the selective activation of a few optic nerve fibres by each electrode was still an open challenge.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [18] Gaillet, 2020, Spatially selective activation of the visual cortex via intraneural stimulation of the optic nerve, Nat. Biomed. Eng. source
Not checked in the free run.
- cites [19] Gaillet, 2021, A machine-learning algorithm correctly classifies cortical evoked potentials from both visual stimulation and electrical stimulation of the optic nerve, J. Neural Eng. source
Not checked in the free run.
May combine two claims.
Premisecitation§ 1. Introduction · p. 3In a concentric bipolar configuration, each stimulating electrode has a concentric return electrode, and the electric field is localised between the two electrodes.
“Each stimulating electrode has a concentric return electrode, and the electric field is localised between the two electrodes [14].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [14] Shivdasani, 2014, Factors affecting perceptual thresholds in a suprachoroidal retinal prosthesis, Invest. Ophthalmol. Vis. Sci. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisecitation§ 1. Introduction · p. 3The OpticSELINE intraneural electrode array was recently proposed for artificial vision via optic nerve electrical stimulation.
“Our research group recently proposed a new intraneural electrode array (OpticSELINE) for artificial vision via optic nerve electrical stimulation [18, 19].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [18] Gaillet, 2020, Spatially selective activation of the visual cortex via intraneural stimulation of the optic nerve, Nat. Biomed. Eng. source
Not checked in the free run.
- cites [19] Gaillet, 2021, A machine-learning algorithm correctly classifies cortical evoked potentials from both visual stimulation and electrical stimulation of the optic nerve, J. Neural Eng. source
Not checked in the free run.
May combine two claims.
Premisereasoning§ 1. Introduction · p. 3The 3D multilayer process allows placing electrodes on separate layers and overlaying feedlines, so each electrode pair occupies the same space on the array as the monopolar configuration.
“This multilayer process allows placing electrodes on separate layers and overlaying the feedlines. Therefore, each electrode pair occupies the same space on the array as the monopolar configuration.”
Quote in the paperSubstantial claimMay combine two claims.
Premisecitation§ 1. Introduction · p. 3In monopolar stimulation, injected current spreads to the common distant ground, preventing confinement of electrical stimulation around the electrode and activating a large portion of neural tissue.
“When the current is injected into the stimulating electrode, the electric field spreads to the common and distant ground, not allowing the confinement of the electrical stimulation around the electrode and resulting in the activation of a large portion of the neural tissue [13].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [13] Moghadam, 2013, Quasi-monopolar stimulation: a novel electrode design configuration for performance optimization of a retinal neuroprosthesis, PLoS One source
Not checked in the free run.
May combine two claims.
Premisereasoning§ 1. Introduction · p. 3A conventional concentric bipolar configuration requires two feedlines for each electrode pair, increasing the space occupied on the array and the size of the implant.
“Compared to the monopolar configuration, the main disadvantage of a conventional CB configuration is that two feedlines are required for each electrode pair, composed of the stimulating electrode and the concentric return electrode. Two feedlines increase the space occupied on the array and, consequently, the size of the implant.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisereasoning§ 4. Discussion · p. 13The ground plane configuration requires fewer feedlines than the QMP configuration.
“Compared to the QMP configuration, its main advantage is that it requires fewer feedlines”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisecitation§ 4. Discussion · p. 13QMP requires complex current injection schemes at each of the hexapolar electrodes, and the electrodes in the external perimeter of the array cannot be used for QMP stimulation.
“QMP requires complex current injection schemes at each of the hexapolar electrodes, and the electrodes in the external perimeter of the array cannot be used for QMP stimulation.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [27] Bendali, 2015, Synthetic 3D diamond-based electrodes for flexible retinal neuroprostheses: model, production and in vivo biocompatibility, Biomaterials source
Not checked in the free run.
May combine two claims.
Interpretationown data§ 3.1. Hybrid FEA-NEURON modelling · p. 7For low current amplitudes in monopolar configuration, the activated area is not symmetrical to the horizontal plane because the electrode is exposed to the upper part of the nerve and the PI substrate reduces stimulation in the lower part.
“For low current amplitudes, the shape is not symmetrical to the horizontal plane because the electrode is exposed to the upper part of the nerve, and the PI substrate reduces the stimulation in the lower part of the nerve.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Interpretationreasoning§ 4. Discussion · p. 13Measuring the fibre activation upon electrical stimulation in the optic nerve remains an open challenge due to the limited space available in the intracranial segment.
“measuring the fibre activation upon electrical stimulation in the optic nerve remains an open challenge due to the limited space available in the intracranial segment, where the array is currently implanted.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone given§ 4. Discussion · p. 13The QMP configuration is suitable for large surface electrode arrays and not for intraneural electrode arrays.
“the QMP configuration is suitable for large surface electrode arrays (e.g. retinal prostheses or ECoG arrays) and not for intraneural electrode arrays.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone given§ 4. Discussion · p. 13A ground plane surrounding each electrode of the array limits the final electrode density.
“a ground plane surrounding each electrode of the array limits the final electrode density.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone given§ 2.7. Signal processing · p. 5EEPs were visually inspected and manually rejected when presenting noisy signals before data analysis.
“Before data analysis in MATLAB, EEPs were visually inspected and manually rejected when presenting noisy signals.”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationreasoning§ 3.1. Hybrid FEA-NEURON modelling · p. 7In 3D multilayer concentric bipolar configuration, stimulation is localised vertically to a few tens of micrometres from the electrode surface, unlike monopolar configuration.
“Thus, the stimulation is localised vertically to a few tens of micrometres from the electrode surface, which is not the case for the monopolar configuration.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone given§ 2.8. Statistical analysis and graphical representation · p. 6The D'Agostino and Pearson omnibus normality test was performed to justify the choice of the statistical test.
“The D'Agostino and Pearson omnibus normality test was performed to justify the choice of the statistical test.”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationreasoning§ 3.1. Hybrid FEA-NEURON modelling · p. 8The peripheral area with low activation probabilities visible in the monopolar configuration is associated with the activation of larger fibres away from the electrode since they have a lower activation threshold compared to smaller fibres.
“The peripheral area with low activation probabilities visible in the monopolar configuration is associated with the activation of larger fibres away from the electrode since they have a lower activation threshold compared to smaller fibres.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisecitation§ 4. Discussion · p. 13The ground plane configuration provides focalisation of the currents.
“A second option is the ground plane configuration, where a highly conductive local ground plane provides focalisation of the currents [28, 29].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [28] Joucla, 2009, Improved focalization of electrical microstimulation using microelectrode arrays: a modeling study, PLoS One source
Not checked in the free run.
- cites [29] Joucla, 2014, Current approaches to model extracellular electrical neural microstimulation, Front. Comput. Neurosci. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductcitation§ 2.5. Animal handling and surgery · p. 5Animal experiments were performed according to authorisation GE519 approved by the Département de l'Emploi, des Affaires Sociales et de la Santé, Direction Générale de la Santé of the Republique et Canton de Genève (Switzerland).
“Animal experiments were performed according to the authorisation GE519 approved by the Département de l'Emploi, des Affaires Sociales et de la Santé, Direction Générale de la Santé of the Republique et Canton de Genève (Switzerland), as previously described [19].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [19] Gaillet, 2021, A machine-learning algorithm correctly classifies cortical evoked potentials from both visual stimulation and electrical stimulation of the optic nerve, J. Neural Eng. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone given§ 2.6. Electrophysiological recording and stimulation · p. 5The stimulation protocol was repeated 30 times for rabbit 1 and 15 times for rabbit 2 for both monopolar and 3D multilayer concentric bipolar configurations.
“The stimulation protocol was repeated 30 times (rabbit 1) and 15 times (rabbit 2) for both monopolar and 3D multilayer CB configurations.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisereasoning§ 4. Discussion · p. 13A metallic ground plane exposed to the extracellular medium is not advantageous because of the risk of delamination, it makes the device not transparent, and it may crack due to implant bending.
“A metallic ground plane exposed to the extracellular medium is not advantageous because of the risk of delamination, it makes the device not transparent (if necessary), and it may crack due to the implant bending necessary in most surgical insertions.”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationown data§ 3.3. Electrophysiological validation in-vivo · p. 12More pulses in the train increased the EEP peak-to-peak amplitude by increasing the probability of fibre activation via a mechanism of temporal summation resulting from the repeated activation of the same few fibres and not by the enlargement of the activated area of the nerve.
“More pulses in the train increased the EEP peak-topeak amplitude by increasing the probability of fibre activation via a mechanism of temporal summation resulting from the repeated activation of the same few fibres and not by the enlargement of the activated area of the nerve.”
Quote in the paperSubstantial claim
The paper relies on this without support.
Highly focused electric stimulation is crucial to achieving high selectivity in fibre activation.
“Highly focused electric stimulation is crucial to achieving high selectivity in fibre activation.”
The paper relies on this without support.
There is a trade-off between electrode density and electrical independence in neural interfaces.
“Although these two concepts work in theory, there is a constraint in practice: a trade-off between density and independence must be found.”
The paper relies on this without support.
Measuring the recruitment of nerve fibres in vivo is a challenging task.
“However, measuring the recruitment of nerve fibres in-vivo is a challenging task.”
The paper relies on this without support.
Similar total activation probability across the entire nerve section corresponds to a similar number of activated fibres.
“It must also be clarified that a similar total activation probability corresponds to a similar number of activated fibres.”
The paper relies on this without support.
The peak-to-peak amplitude of EEPs recorded in V1 is a valid proxy for the number of fibres activated in the optic nerve.
“Thus, we could infer that a lower peak-to-peak amplitude of the EEPs with the 3D multilayer CB configuration is associated with fewer fibres activated in the optic nerve.”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Results in rabbits showed that the selective activation of different portions of the optic nerve induced spatially organised cortical activation patterns in the rabbit's V1.
“Results in rabbits showed that the selective activation of different portions of the optic nerve induced spatially organised cortical activation patterns in the rabbit's V1 [63,74,75].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [75]
A common approach is to use bipolar stimulation through two close electrodes, as shown in retinal, optic nerve, and thalamic prostheses.
“A common approach is to use bipolar stimulation through two close electrodes, as shown in retinal [36,143,144], optic nerve [75], and thalamic prostheses [81].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [75]
The citation lists haven’t been fetched yet
References 41 · Cited by 11
- Authors
- Borda, E., Gaillet, V., Airaghi Leccardi, M. J. I., Zollinger, E. G., Moreira, R. C., & Ghezzi, D.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Corresponding author
- Ghezzi, Diego
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2022-05-27
- Volume
- 19
- Issue
- 3
- Pages
- 036016
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W4228999278
- Semantic Scholar
- c72a6a53f9979ad03720c3d104d28f2c199c9f31
- Cited by
- 11
- References
- 41
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 4 · 2022: 3
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- École Polytechnique Fédérale de Lausanne
- Swiss National Science Foundation (200021_182670)
- Medtronic plc
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- optic nerve stimulation, monopolar stimulation, evoked potentials, primary visual cortex, bioelectronic medicine
- MeSH terms
- Animals, Electric Stimulation, Electrodes, Electrodes, Implanted, Evoked Potentials, Visual, Optic Nerve, Rabbits, Visual Cortex
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-08.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-08.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review