Detection of the Ischemic Penumbra Using pH-Weighted MRI
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
The classic definition of the ischemic penumbra is a hypoperfused region in which metabolism is impaired, but still sufficient to maintain cellular polarization. Perfusion- and diffusion-weighted MRI (PWI, DWI) can identify regions of reduced perfusion and cellular depolarization, respectively, but it often remains unclear whether a PWI—DWI mismatch corresponds to benign oligemia or a true penumbra. We hypothesized that pH-weighted MRI (pHWI) can subdivide the PWI—DWI mismatch into these regions. Twenty-one rats underwent permanent middle cerebral artery occlusion and ischemic evolution over the first 3.5 h post-occlusion was studied using multiparametric MRI. End point was the stroke area defined by T 2-hyperintensity at 24 h. In the acute phase, areas of reduced pH were always larger than or equal to DWI deficits and smaller than or equal to PWI deficits. Group analysis showed that pHWI deficits during this phase coincided with the resulting infarct area at endpoint. Final infarcts were smaller than PWI deficits (range 65% to 90%, depending on the severity of the occlusion) and much larger than acute DWI deficits. These data suggest that the outer boundary of the hypoperfused area showing a decrease in pH without DWI abnormality may correspond to the outer boundary of the ischemic penumbra, while the hypoperfused region at normal pH may correspond to benign oligemia. These first results show that pHWI can provide information complementary to PWI and DWI in the delineation of ischemic tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Ward, K. M., Aletras, A. H., & Balaban, R. S. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1956 · Cited by 1,429
Viability thresholds and the penumbra of focal ischemia
Hossmann, K. (1994) · Annals of Neurology · doi:10.1002/ana.410360404 · Cited by 1,370 · cited 3×
“The classic definition of the penumbra (Astrup, 1976; Hossmann, 1994) is based on impaired metabolism that can sustain still-viable tissue for a limited period of time.”
BackgroundUsing the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI
Zhou, J., Payen, J.-F., Wilson, D. A., Traystman, R. J., & van Zijl, P. C. M. (2003) · Nature Medicine · doi:10.1038/nm907 · Cited by 1,198
Self-citationWu, O., Østergaard, L., Weisskoff, R. M., Benner, T., Rosen, B. R., & Sorensen, A. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10522 · Cited by 604
The role of diffusion tensor imaging in the evaluation of ischemic brain injury – a review
Sotak, C. H. (2002) · NMR in Biomedicine · doi:10.1002/nbm.786 · Cited by 433
Neumann-Haefelin, T., Kastrup, A., de Crespigny, A., Yenari, M. A., Ringer, T., Sun, G. H., & Moseley, M. E. (2000) · Stroke · doi:10.1161/01.str.31.8.1965 · Cited by 347
Magnetization transfer contrast in magnetic resonance imaging.
Balaban, R. S., & Ceckler, T. L. (1992) · PubMed · Cited by 331
Minematsu, K., Li, L., Sotak, C. H., Davis, M. A., & Fisher, M. (1992) · Stroke · doi:10.1161/01.str.23.9.1304 · Cited by 320
Cited by
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Magnetic resonance imaging of glutamate
Cai, K., Haris, M., Singh, A., Kogan, F., Greenberg, J. H., Hariharan, H., Detre, J. A., & Reddy, R. (2012) · Nature Medicine · doi:10.1038/nm.2615 · Cited by 660
APT‐weighted MRI: Techniques, current neuro applications, and challenging issues
Zhou, J., Heo, H., Knutsson, L., van Zijl, P. C. M., & Jiang, S. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26645 · Cited by 345
Self-citationvan Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
Self-citationPractical data acquisition method for human brain tumor amide proton transfer (APT) imaging
Zhou, J., Blakeley, J. O., Hua, J., Kim, M., Laterra, J., Pomper, M. G., & van Zijl, P. C. M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21712 · Cited by 338
Self-citationNuts and bolts of chemical exchange saturation transfer MRI
Liu, G., Song, X., Chan, K. W. Y., & McMahon, M. T. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2899 · Cited by 318
Jin, T., Wang, P., Zong, X., & Kim, S. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24315 · Cited by 273
Jones, C. K., Polders, D., Hua, J., Zhu, H., Hoogduin, H. J., Zhou, J., Luijten, P., & van Zijl, P. C. M. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23141 · Cited by 209
“One type of CEST imaging, amide proton transfer (APT) of mobile cellular peptides and proteins (8,9), has a unique contrast that increases for brain tumors (8,10) and reduces when pH is lowered during acute ischemia (9,11).”
BackgroundSelf-citationDesmond, K. L., Moosvi, F., & Stanisz, G. J. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24822 · Cited by 198
“A pH-dependent relationship between the CEST asymmetry and pH has been observed , which led it to be called pH-weighted contrast by some authors (29).”
BackgroundJin, T., Autio, J., Obata, T., & Kim, S.-G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22721 · Cited by 194
Cerebral ischemia: Models, methods and outcomes
Hossmann, K.-A. (2008) · Neuropharmacology · doi:10.1016/j.neuropharm.2007.12.004 · Cited by 175
Tietze, A., Blicher, J., Mikkelsen, I. K., Østergaard, L., Strother, M. K., Smith, S. A., & Donahue, M. J. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3048 · Cited by 171
“(15,16) have demonstrated the potential of this method by monitoring the evolution of pH changes following middle cerebral artery occlusion in anesthetized rats at 4.”
McVicar, N., Li, A. X., Gonçalves, D. F., Bellyou, M., Meakin, S. O., Prado, M. A., & Bartha, R. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.12 · Cited by 168
Identifying the ischaemic penumbra using pH-weighted magnetic resonance imaging
Harston, G. W. J., Tee, Y. K., Blockley, N., Okell, T. W., Thandeswaran, S., Shaya, G., Sheerin, F., Cellerini, M., Payne, S., Jezzard, P., et al. (2015) · Brain · doi:10.1093/brain/awu374 · Cited by 166
“…evidence of metabolic stress) and benign oligaemia (low CBF with minimal evidence of metabolic stress) in a way consistent with the preclinical data (Sun et al., 2007; Zhou and van Zijl, 2011). pH-weighted MRI provides an insight into ADC lesion reversal, which has variously been reported at 6.7%…”
BackgroundResultInfluentialSun, P. Z., Farrar, C. T., & Sorensen, A. G. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21398 · Cited by 162
Self-citationImaging tumor acidosis: a survey of the available techniques for mapping in vivo tumor pH
Anemone, A., Consolino, L., Arena, F., Capozza, M., & Longo, D. L. (2019) · Cancer and Metastasis Reviews · doi:10.1007/s10555-019-09782-9 · Cited by 162
“This endogenous pHmapping method has also been shown to detect changes in pH following ischemia damage, but not yet applied to map tumor pH [61].”
Metadata
- Authors
- Sun, P. Z., Zhou, J., Sun, W., Huang, J., & van Zijl, P. C.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2007-06
- Volume
- 27
- Issue
- 6
- Pages
- 1129-1136
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2012678826
- Cited by
- 334
- References
- 34
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.