Detection of the Ischemic Penumbra Using pH-Weighted MRI
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
The classic definition of the ischemic penumbra is a hypoperfused region in which metabolism is impaired, but still sufficient to maintain cellular polarization. Perfusion- and diffusion-weighted MRI (PWI, DWI) can identify regions of reduced perfusion and cellular depolarization, respectively, but it often remains unclear whether a PWI—DWI mismatch corresponds to benign oligemia or a true penumbra. We hypothesized that pH-weighted MRI (pHWI) can subdivide the PWI—DWI mismatch into these regions. Twenty-one rats underwent permanent middle cerebral artery occlusion and ischemic evolution over the first 3.5 h post-occlusion was studied using multiparametric MRI. End point was the stroke area defined by T 2-hyperintensity at 24 h. In the acute phase, areas of reduced pH were always larger than or equal to DWI deficits and smaller than or equal to PWI deficits. Group analysis showed that pHWI deficits during this phase coincided with the resulting infarct area at endpoint. Final infarcts were smaller than PWI deficits (range 65% to 90%, depending on the severity of the occlusion) and much larger than acute DWI deficits. These data suggest that the outer boundary of the hypoperfused area showing a decrease in pH without DWI abnormality may correspond to the outer boundary of the ischemic penumbra, while the hypoperfused region at normal pH may correspond to benign oligemia. These first results show that pHWI can provide information complementary to PWI and DWI in the delineation of ischemic tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Ward, K. M., Aletras, A. H., & Balaban, R. S. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1956 · Cited by 1,429
Viability thresholds and the penumbra of focal ischemia
Hossmann, K. (1994) · Annals of Neurology · doi:10.1002/ana.410360404 · Cited by 1,370 · cited 3×
“The classic definition of the penumbra (Astrup, 1976; Hossmann, 1994) is based on impaired metabolism that can sustain still-viable tissue for a limited period of time.”
BackgroundUsing the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI
Zhou, J., Payen, J.-F., Wilson, D. A., Traystman, R. J., & van Zijl, P. C. M. (2003) · Nature Medicine · doi:10.1038/nm907 · Cited by 1,198
Self-citationWu, O., Østergaard, L., Weisskoff, R. M., Benner, T., Rosen, B. R., & Sorensen, A. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10522 · Cited by 604
The role of diffusion tensor imaging in the evaluation of ischemic brain injury – a review
Sotak, C. H. (2002) · NMR in Biomedicine · doi:10.1002/nbm.786 · Cited by 433
Neumann-Haefelin, T., Kastrup, A., de Crespigny, A., Yenari, M. A., Ringer, T., Sun, G. H., & Moseley, M. E. (2000) · Stroke · doi:10.1161/01.str.31.8.1965 · Cited by 347
Magnetization transfer contrast in magnetic resonance imaging.
Balaban, R. S., & Ceckler, T. L. (1992) · PubMed · Cited by 331
Minematsu, K., Li, L., Sotak, C. H., Davis, M. A., & Fisher, M. (1992) · Stroke · doi:10.1161/01.str.23.9.1304 · Cited by 320
Zhou, J., Wilson, D. A., Sun, P. Z., Klaus, J. A., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20048 · Cited by 293
Self-citationSevere ADC Decreases Do Not Predict Irreversible Tissue Damage In Humans
Fiehler, J., Foth, M., Kucinski, T., Knab, R., von Bezold, M., Weiller, C., Zeumer, H., & Röther, J. (2002) · Stroke · doi:10.1161/hs0102.100884 · Cited by 286
Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan
Mori, S., & Van Zijl, P. C. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330107 · Cited by 278
Self-citationWu, O., Koroshetz, W. J., Østergaard, L., Buonanno, F. S., Copen, W. A., Gonzalez, R. G., Rordorf, G., Rosen, B. R., Schwamm, L. H., Weisskoff, R. M., et al. (2001) · Stroke · doi:10.1161/01.str.32.4.933 · Cited by 259
Goffeney, N., Bulte, J. W. M., Duyn, J., Bryant, L. H., & van Zijl, P. C. M. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0158455 · Cited by 195
Self-citationPerfusion imaging with compensation for asymmetric magnetization transfer effects
Pekar, J., Jezzard, P., Roberts, D. A., Leigh, J. S., Frank, J. A., & McLaughlin, A. C. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350110 · Cited by 155
Application of magnetic resonance to animal models of cerebral ischemia
Hoehn, M., Nicolay, K., Franke, C., & van der Sanden, B. P. J. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1213 · Cited by 147
Magnetic Resonance Imaging in Experimental Models of Brain Disorders
Dijkhuizen, R. M., & Nicolay, K. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000100341.78607.eb · Cited by 146
NMR imaging of labile proton exchange
Wolff, S. D., & Balaban, R. S. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90220-4 · Cited by 143
An, H., & Lin, W. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10148 · Cited by 126
Evolving Paradigms in Neuroimaging of the Ischemic Penumbra
Kidwell, C. S., Alger, J. R., & Saver, J. L. (2004) · Stroke · doi:10.1161/01.str.0000143222.13069.70 · Cited by 119
Nicoli, F., Fur, Y. L., Denis, B., Ranjeva, J., Sylviane Confort-gouny, A., & Cozzone, P. J. (2003) · Stroke · doi:10.1161/01.str.0000078659.43423.0a · Cited by 116
Determination of Oxygen Extraction Ratios by Magnetic Resonance Imaging
Oja, J. M. E., GILLEN, J. S., Kauppinen, R. A., Kraut, M. A., & van Zijl, P. C. M. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199912000-00001 · Cited by 114
Lu, H., & van Zijl, P. C. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20379 · Cited by 114
Self-citationMagnetic resonance cerebral metabolic rate of oxygen utilization in hyperacute stroke patients
Lee, J., Vo, K. D., An, H., Çelik, A., Lee, Y. Z., Hsu, C. Y., & Lin, W. (2003) · Annals of Neurology · doi:10.1002/ana.10433 · Cited by 111
Minematsu, K., Fisher, M., Li, L., & Sotak, C. H. (1993) · Stroke · doi:10.1161/01.str.24.12.2074 · Cited by 108
Gröhn, O. H. J., Lukkarinen, J. A., Oja, J. M. E., van Zijl, P. C. M., Ulatowski, J. A., Traystman, R. J., & Kauppinen, R. A. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199808000-00012 · Cited by 95
Moseley, M. E., Mintorovitch, J., Cohen, Y., Asgari, H. S., Derugin, N., Norman, D. M., & Kucharczyk, J. R. (1990) · Springer eBooks · doi:10.1007/978-3-7091-9115-6_70 · Cited by 84
Present Status of Magnetic Resonance Imaging and Spectroscopy in Animal Stroke Models
Weber, R., Ramos‐Cabrer, P., & Hoehn, M. (2006) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600241 · Cited by 69
Suppression of lipid artifacts in amide proton transfer imaging
Sun, P. Z., Zhou, J., Sun, W., Huang, J., & van Zijl, P. C. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20530 · Cited by 64
Self-citationDiffusion-Weighted Imaging in Acute Stroke – A Tool of Uncertain Value?
Fiehler, J., Fiebach, J. B., Gass, A., Hoehn, M., Kucinski, T., Neumann‐Haefelin, T., Schellinger, P. D., Siebler, M., Villringer, A., & Röther, J. (2002) · Cerebrovascular Diseases · doi:10.1159/000065675 · Cited by 53
Thresholds of cerebral ischemia
Astrup, J., Symon, L., Branston, N. M., & Lassen, N. A. (1977) · Springer eBooks · doi:10.1007/978-1-4612-6349-4_3 · Cited by 34
Imaging the ischemic penumbra and treatment effects by PET.
Heiss, W. (2001) · The Keio Journal of Medicine · doi:10.2302/kjm.50.249 · Cited by 22
Wheeler-Kingshott (2000) · doi:10.1002/1522-2594(200011)44:5
Cited by
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Magnetic resonance imaging of glutamate
Cai, K., Haris, M., Singh, A., Kogan, F., Greenberg, J. H., Hariharan, H., Detre, J. A., & Reddy, R. (2012) · Nature Medicine · doi:10.1038/nm.2615 · Cited by 660
APT‐weighted MRI: Techniques, current neuro applications, and challenging issues
Zhou, J., Heo, H., Knutsson, L., van Zijl, P. C. M., & Jiang, S. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26645 · Cited by 345
Self-citationvan Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
Self-citationPractical data acquisition method for human brain tumor amide proton transfer (APT) imaging
Zhou, J., Blakeley, J. O., Hua, J., Kim, M., Laterra, J., Pomper, M. G., & van Zijl, P. C. M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21712 · Cited by 338
Self-citation
Metadata
- Authors
- Sun, P. Z., Zhou, J., Sun, W., Huang, J., & van Zijl, P. C.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2007-06
- Volume
- 27
- Issue
- 6
- Pages
- 1129-1136
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2012678826
- Cited by
- 334
- References
- 34
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.