MRI-Guided Diffuse Optical Spectroscopy of Malignant and Benign Breast Lesions
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
We present the clinical implementation of a novel hybrid system that combines magnetic resonance imaging (MRI) and near-infrared (NIR) optical measurements for the noninvasive study of breast cancer in vivo. Fourteen patients were studied with a MR-NIR prototype imager and spectrometer. A diffuse optical tomographic scheme employed the MR images as a priori information to implement an image-guided NIR localized spectroscopic scheme. All patients who entered the study also underwent gadolinium-enhanced MRI and biopsy so that the optical findings were cross-validated with MR readings and histopathology. The technique quantified the oxy- and deoxyhemoglobin of five malignant and nine benign breast lesions in vivo. Breast cancers were found with decreased oxygen saturation and higher blood concentration than most benign lesions. The average hemoglobin concentration ([H]) of cancers was 0.130+/-0.100 mM, and the average hemoglobin saturation (Y) was 60+/-9% compared to [H]=0.018+/-0.005 mM and Y=69+/-6% of background tissue. Fibroadenomas exhibited high hemoglobin concentration [H]=0.060+/-0.010 mM and mild decrease in oxygen saturation Y=67+/-2%. Cysts and other normal lesions were easily differentiated based on intrinsic contrast information. This novel optical technology can be a significant add-on in MR examinations and can be used to characterize functional parameters of cancers with diagnostic and treatment prognosis potential. It is foreseen that the technique can play a major role in functional activation studies of brain and muscle as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
Tumor Hypoxia: Definitions and Current Clinical, Biologic, and Molecular Aspects
Hockel, M., & Vaupel, P. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.4.266 · Cited by 2,662
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Self-citationNon-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Self-citation(1996) · PubMed · Cited by 1,188
Barriers to Drug Delivery in Solid Tumors
Jain, R. K. (1994) · Scientific American · doi:10.1038/scientificamerican0794-58 · Cited by 1,069
Fluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827
Self-citationConcurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Self-citationNon-Invasive In Vivo Characterization of Breast Tumors Using Photon Migration Spectroscopy
Tromberg, B. J., Shah, N., Lanning, R., Cerussi, A., Espinoza, J., Pham, T., Svaasand, L., & Butler, J. (2000) · Neoplasia · doi:10.1038/sj.neo.7900082 · Cited by 687
104 candidate genes for the hypoxic tumor phenotype
Koong, A. C., Denko, N. O., Schindler, C., Le, Q. T., Terris, D. T., Ibrahim, H. Z., Goffinet, D. R., & Giaccia, A. J. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)90122-0 · Cited by 285
Cited by
Shedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,909
Self-citationDiffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Self-citationRecent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Fass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
FLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731
Self-citationBoas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Optical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625
Ellis, D. I., & Goodacre, R. (2006) · The Analyst · doi:10.1039/b602376m · Cited by 614
Bhaskar, S., Tian, F., Stoeger, T., Kreyling, W., de la Fuente, J. M., Grazú, V., Borm, P., Estrada, G., Ntziachristos, V., & Razansky, D. (2010) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-7-3 · Cited by 495
Self-citationSingle-breath-hold photoacoustic computed tomography of the breast
Lin, L., Hu, P., Shi, J., Appleton, C. M., Maslov, K., Li, L., Zhang, R., & Wang, L. V. (2018) · Nature Communications · doi:10.1038/s41467-018-04576-z · Cited by 454
Assessing the future of diffuse optical imaging technologies for breast cancer management
Tromberg, B. J., Pogue, B. W., Paulsen, K. D., Yodh, A. G., Boas, D. A., & Cerussi, A. E. (2008) · Medical Physics · doi:10.1118/1.2919078 · Cited by 326
Self-citationImaging Angiogenesis: Applications and Potential for Drug Development
Miller, J. C., Pien, H. H., Sahani, D., Sorensen, A. G., & Thrall, J. H. (2005) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/dji023 · Cited by 325
Electromagnetic Breast Imaging: Results of a Pilot Study in Women with Abnormal Mammograms
Poplack, S. P., Tosteson, T. D., Wells, W. A., Pogue, B. W., Meaney, P. M., Hartov, A., Kogel, C. A., Soho, S. K., Gibson, J. J., & Paulsen, K. D. (2007) · Radiology · doi:10.1148/radiol.2432060286 · Cited by 299
Optical imaging in drug discovery and diagnostic applications
LICHA, K., & OLBRICH, C. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.01.021 · Cited by 263
Brooksby, B., Pogue, B. W., Jiang, S., Dehghani, H., Srinivasan, S., Kogel, C., Tosteson, T. D., Weaver, J., Poplack, S. P., & Paulsen, K. D. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509636103 · Cited by 236
Choe, R., Konecky, S. D., Corlu, A., Lee, K., Durduran, T., Busch, D. R., Pathak, S., Czerniecki, B. J., Tchou, J., Fraker, D. L., et al. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3103325 · Cited by 236
Self-citationHybrid PET-optical imaging using targeted probes
Nahrendorf, M., Keliher, E., Marinelli, B., Waterman, P., Feruglio, P. F., Fexon, L., Pivovarov, M., Swirski, F. K., Pittet, M. J., Vinegoni, C., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0915163107 · Cited by 222
“Multimodality image fusion can be achieved with feature recognition (19), contour mapping (20), fiducial matching (13, 15, 21), or other approaches (22).”
BackgroundMULTIMODALITY IN VIVO IMAGING SYSTEMS: Twice the Power or Double the Trouble?
Cherry, S. R. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095728 · Cited by 188
“The system was used for contrast-enhanced diffuse optical tomography of the breast (95) and to perform MR-guided optical spectroscopy in breast lesions (96).”
Simple and robust image-based autofocusing for digital microscopy
Yazdanfar, S., Kenny, K. B., Tasimi, K., Corwin, A. D., Dixon, E. L., & Filkins, R. J. (2008) · Optics Express · doi:10.1364/oe.16.008670 · Cited by 171
Gibson, A., & Dehghani, H. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0080 · Cited by 159
Near‐Infrared Diffuse Optical Tomography
Hielscher, A. H., Bluestone, A. Y., Abdoulaev, G. S., Klose, A. D., Lasker, J., Stewart, M., Netz, U., & Beuthan, J. (2002) · Disease Markers · doi:10.1155/2002/164252 · Cited by 159
“methods [81,147].”
Metadata
- Authors
- Ntziachristos, V., Yodh, A. G., Schnall, M. D., & Chance, B.
- Venue
- Neoplasia
- Publisher
- Elsevier BV
- Published
- 2002
- Volume
- 4
- Issue
- 4
- Pages
- 347-354
- ISSN
- 1476-5586 (ISSN-L)
- OpenAlex
- W2089499666
- Cited by
- 321
- References
- 23
- FWCI
- 16.05
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.