The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Breathable and Stretchable Temperature Sensors Inspired by Skin
Open accessAbstract
Flexible electronics attached to skin for healthcare, such as epidermal electronics, has to struggle with biocompatibility and adapt to specified environment of skin with respect to breath and perspiration. Here, we report a strategy for biocompatible flexible temperature sensors, inspired by skin, possessing the excellent permeability of air and high quality of water-proof by using semipermeable film with porous structures as substrate. We attach such temperature sensors to underarm and forearm to measure the axillary temperature and body surface temperature respectively. The volunteer wears such sensors for 24 hours with two times of shower and the in vitro test shows no sign of maceration or stimulation to the skin. Especially, precise temperature changes on skin surface caused by flowing air and water dropping are also measured to validate the accuracy and dynamical response. The results show that the biocompatible temperature sensor is soft and breathable on the human skin and has the excellent accuracy compared to mercury thermometer. This demonstrates the possibility and feasibility of fully using the sensors in long term body temperature sensing for medical use as well as sensing function of artificial skin for robots or prosthesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Self-citationA Stretchable Form of Single-Crystal Silicon for High-Performance Electronics on Rubber Substrates
Khang, D.-Y., Jiang, H., Huang, Y., & Rogers, J. A. (2006) · Science · doi:10.1126/science.1121401 · Cited by 1,689
Someya, T., Kato, Y., Sekitani, T., Iba, S., Noguchi, Y., Murase, Y., Kawaguchi, H., & Sakurai, T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502392102 · Cited by 1,389
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Controlled buckling of semiconductor nanoribbons for stretchable electronics
Sun, Y., Choi, W. M., Jiang, H., Huang, Y. Y., & Rogers, J. A. (2006) · Nature Nanotechnology · doi:10.1038/nnano.2006.131 · Cited by 933
Multifunctional Epidermal Electronics Printed Directly Onto the Skin
Yeo, W., Kim, Y., Lee, J., Ameen, A., Shi, L., Li, M., Wang, S., Ma, R., Jin, S. H., Kang, Z., et al. (2013) · Advanced Materials · doi:10.1002/adma.201204426 · Cited by 828
Materials and Optimized Designs for Human‐Machine Interfaces Via Epidermal Electronics
Jeong, J., Yeo, W., Akhtar, A., Norton, J. J. S., Kwack, Y., Li, S., Jung, S., Su, Y., Lee, W., Xia, J., et al. (2013) · Advanced Materials · doi:10.1002/adma.201301921 · Cited by 827
In vivo measurements of the elastic mechanical properties of human skin by indentation tests
Pailler-Mattei, C., Bec, S., & Zahouani, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.011 · Cited by 724
Highly Stretchy Black Gold E‐Skin Nanopatches as Highly Sensitive Wearable Biomedical Sensors
Gong, S., Lai, D. T. H., Su, B., Si, K. J., Ma, Z., Yap, L. W., Guo, P., & Cheng, W. (2015) · Advanced Electronic Materials · doi:10.1002/aelm.201400063 · Cited by 461
Competing Fracture in Kinetically Controlled Transfer Printing
Feng, X., Meitl, M. A., Bowen, A. M., Huang, Y., Nuzzo, R. G., & Rogers, J. A. (2007) · Langmuir · doi:10.1021/la701555n · Cited by 411
Self-citationFlexible Wireless Temperature Sensors Based on Ni Microparticle‐Filled Binary Polymer Composites
Jeon, J., Lee, H., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201204082 · Cited by 346
Chitosan‐alginate PEC membrane as a wound dressing: Assessment of incisional wound healing
Wang, L., Khor, E., Wee, A., & Lim, L. Y. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10382 · Cited by 318
Materials and Designs for Wireless Epidermal Sensors of Hydration and Strain
Huang, X., Liu, Y., Cheng, H., Shin, W., Fan, J. A., Liu, Z., Lu, C., Kong, G., Chen, K., Patnaik, D., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303886 · Cited by 302
Capacitive Epidermal Electronics for Electrically Safe, Long‐Term Electrophysiological Measurements
Jeong, J., Kim, M. K., Cheng, H., Yeo, W., Huang, X., Liu, Y., Zhang, Y., Huang, Y., & Rogers, J. A. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201300334 · Cited by 288
Zhang, K., Wang, X., Yang, Y., & Wang, Z. L. (2015) · ACS Nano · doi:10.1021/nn507455f · Cited by 281
Flexible humidity and temperature sensor based on cellulose–polypyrrole nanocomposite
Mahadeva, S. K., Yun, S., & Kim, J. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2010.10.018 · Cited by 228
Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite
Shih, W.-P., Tsao, L.-C., Lee, C.-W., Cheng, M.-Y., Chang, C., Yang, Y.-J., & Fan, K.-C. (2010) · Sensors · doi:10.3390/s100403597 · Cited by 226
Mechanics of Epidermal Electronics
Wang, S., Li, M., Wu, J., Kim, D.-H., Lu, N., Su, Y., Kang, Z., Huang, Y., & Rogers, J. A. (2012) · Journal of Applied Mechanics · doi:10.1115/1.4005963 · Cited by 214
Graz, I., Krause, M., Bauer-Gogonea, S., Bauer, S., Lacour, S. P., Ploss, B., Zirkl, M., Stadlober, B., & Wagner, S. (2009) · Journal of Applied Physics · doi:10.1063/1.3191677 · Cited by 212
Miniaturized Flexible Temperature Sensor
Moser, Y., & Gijs, M. A. M. (2007) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2007.908437 · Cited by 201
Stretchability and compliance of freestanding serpentine-shaped ribbons
Widlund, T., Yang, S., Hsu, Y.-Y., & Lu, N. (2014) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2014.07.025 · Cited by 197
Temperature, humidity and gas sensors integrated on plastic foil for low power applications
Oprea, A., Courbat, J., Bârsan, N., Briand, D., de Rooij, N. F., & Weimar, U. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.04.019 · Cited by 153
Chen, H., Feng, X., Huang, Y., Huang, Y. Y., & Rogers, J. A. (2013) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2013.04.001 · Cited by 135
Self-citationFlexible thin film temperature and strain sensor array utilizing a novel sensing concept
Lichtenwalner, D. J., Hydrick, A. E., & Kingon, A. I. (2006) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2006.07.019 · Cited by 100
Yari, A., Yeganeh, H., & Bakhshi, H. (2012) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-012-4683-6 · Cited by 89
A 32 × 32 temperature and tactile sensing array using PI-copper films
Yang, Y.-J. J., Cheng, M., Shih, S.-H., Huang, X.-H., Tsao, C.-M., Chang, F.-Y., & Fan, K. (2009) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-009-1940-z · Cited by 81
Kelly, G. S. (2007) · PubMed · Cited by 61
A new porous polyetherurethane wound covering
de Bruin, P., Jonkman, M. F., Meijer, H. J., & Pennings, A. J. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240208 · Cited by 60
A cost-effective flexible MEMS technique for temperature sensing
Xiao, S., Che, L., Li, X., & Wang, Y. (2007) · Microelectronics Journal · doi:10.1016/j.mejo.2007.01.022 · Cited by 49
Interfacial Failure in Flexible Electronic Devices
Chen, H., Lu, B., Lin, Y., & Feng, X. (2014) · IEEE Electron Device Letters · doi:10.1109/led.2013.2289932 · Cited by 46
Self-citationEvaluation of wound‐covering materials
Schwope, A. D., Wise, D. L., Sell, K. W., Dressler, D. P., & Skornik, W. A. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110405 · Cited by 44
Stretchability of indium tin oxide (ITO) serpentine thin films supported by Kapton substrates
Yang, S., Su, B., Bitar, G., & Lu, N. (2014) · International Journal of Fracture · doi:10.1007/s10704-014-9977-x · Cited by 38
Micromachined integrated pressure—thermal sensors on flexible substrates
Shamanna, V., Das, S., Çelik‐Butler, Z., Butler, D. P., & Lawrence, K. L. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/10/010 · Cited by 36
Directionally controlled transfer printing using micropatterned stamps
Chen, H., Feng, X., & Chen, Y. (2013) · Applied Physics Letters · doi:10.1063/1.4824976 · Cited by 33
Self-citation
Cited by
Artificial multimodal receptors based on ion relaxation dynamics
You, I., Mackanic, D. G., Matsuhisa, N., Kang, J., Kwon, J., Beker, L., Mun, J., Suh, W., Kim, T. Y., Tok, J. B.-H., et al. (2020) · Science · doi:10.1126/science.aba5132 · Cited by 632
Flexible Hybrid Electronics for Digital Healthcare
Ma, Y., Zhang, Y., Cai, S., Han, Z., Liu, X., Wang, F., Cao, Y., Wang, Z., Li, H., Chen, Y., et al. (2020) · Advanced Materials · doi:10.1002/adma.201902062 · Cited by 620
Self-citationMultifunctional Skin‐Inspired Flexible Sensor Systems for Wearable Electronics
Xu, K., Lu, Y., & Takei, K. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800628 · Cited by 602
Emerging flexible and wearable physical sensing platforms for healthcare and biomedical applications
Kenry, Yeo, J. C., & Lim, C. T. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.43 · Cited by 550
Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring
Chen, Y., Lu, S., Zhang, S., Li, Y., Qu, Z., Chen, Y., Lu, B., Wang, X., & Feng, X. (2017) · Science Advances · doi:10.1126/sciadv.1701629 · Cited by 467
Self-citation
Metadata
- Authors
- Chen, Y., Lu, B., Chen, Y., & Feng, X.
- Venue
- Scientific Reports
- Published
- 2015-06-22
- Volume
- 5
- Issue
- 1
- Pages
- 11505-11505
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2258698049
- Cited by
- 303
- References
- 35
- FWCI
- 12.27
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.