The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Droplet formation in a microchannel network
Abstract
A method is given for generating droplets in a microchannel network. With oil as the continuous phase and water as the dispersed phase, pico/nanoliter-sized water droplets can be generated in a continuous phase flow at a -junction. The channel for the dispersed phase is 100 microm wide and 100 microm deep, whereas the channel for the continuous phase is 500 microm wide and 100 microm deep. For given experimental parameters, regular-sized droplets are reproducibly formed at a uniform speed. The diameter of these droplets is controllable in the range from 100-380 microm as the flow velocity of the continuous phase is varied from 0.01 m s(-1) to 0.15 m s(-1).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regular‐sized cell creation in microchannel emulsification by visual microprocessing method
Kawakatsu, T., Kikuchi, Y., & Nakajima, M. (1997) · Journal of the American Oil Chemists' Society · doi:10.1007/s11746-997-0143-8 · Cited by 396
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Polymeric Scaffolds in Tissue Engineering Application: A Review
Dhandayuthapani, B., Yoshida, Y., Maekawa, T., & Kumar, D. S. (2011) · International Journal of Polymer Science · doi:10.1155/2011/290602 · Cited by 1,773
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Continuous-flow lithography for high-throughput microparticle synthesis
Dendukuri, D., Pregibon, D. C., Collins, J., Hatton, T. A., & Doyle, P. S. (2006) · Nature Materials · doi:10.1038/nmat1617 · Cited by 1,040
Okushima, S., Nisisako, T., Torii, T., & Higuchi, T. (2004) · Langmuir · doi:10.1021/la0480336 · Cited by 656
Self-citationMicrodroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
Microfluidic Synthesis of Nanomaterials
Song, Y., Hormes, J., & Kumar, C. S. S. R. (2008) · Small · doi:10.1002/smll.200701029 · Cited by 468
Zhao, C.-X., & Middelberg, A. P. J. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.038 · Cited by 397
Active droplet sorting in microfluidics: a review
Xi, H.-D., Zheng, H., Guo, W., Gañán-Calvo, A. M., Ai, Y., Tsao, C.-W., Zhou, J., Li, W., Huang, Y., Nguyen, N.-T., et al. (2017) · Lab on a Chip · doi:10.1039/c6lc01435f · Cited by 369
Zhigaltsev, I. V., Belliveau, N., Hafez, I., Leung, A. K. K., Huft, J., Hansen, C., & Cullis, P. R. (2012) · Langmuir · doi:10.1021/la204833h · Cited by 345
Preparation of highly monodisperse droplet in a T‐junction microfluidic device
Xu, J. H., Li, S. W., Tan, J., Wang, Y. J., & Luo, G. S. (2006) · AIChE Journal · doi:10.1002/aic.10924 · Cited by 335
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Monodispersed microfluidic droplet generation by shear focusing microfluidic device
Tan, Y.-C., Cristini, V., & Lee, A. P. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.06.008 · Cited by 305
Roach, L. S., Song, H., & Ismagilov, R. F. (2005) · Analytical Chemistry · doi:10.1021/ac049061w · Cited by 277
Nanoemulsions: the properties, methods of preparation and promising applications
Koroleva, M. Y., & Yurtov, E. V. (2012) · Russian Chemical Reviews · doi:10.1070/rc2012v081n01abeh004219 · Cited by 269
Microfluidic consecutive flow-focusing droplet generators
Seo, M., Paquet, C., Nie, Z., Xu, S., & Kumacheva, E. (2007) · Soft Matter · doi:10.1039/b700687j · Cited by 263
Continuous Microfluidic Reactors for Polymer Particles
Seo, M., Nie, Z., Xu, S., Mok, M., Lewis, P. C., Graham, R., & Kumacheva, E. (2005) · Langmuir · doi:10.1021/la050519e · Cited by 253
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Guanxing, Z., Liu, Z., Deng, W., & Zhu, W. (2021) · Journal of Optics · doi:10.1088/2040-8986/abcc52 · Cited by 34
Metadata
- Authors
- Nisisako, T., Torii, T., & Higuchi, T.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2002
- Volume
- 2
- Issue
- 1
- Pages
- 24-26
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2148307778
- Cited by
- 607
- References
- 1
- FWCI
- 9.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.