Efficient formation of uniform-sized embryoid bodies using a compartmentalized microchannel device
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The formation of spherical aggregates of cells called embryoid bodies (EBs) is an indispensable step in many protocols in which embryonic stem (ES) cells are differentiated to other cell types. Appropriate morphology and embryo size are critical for the sequential developmental stages of naturally conceived embryos. Likewise, regulating the size of EBs and the timing of their formation is crucial for controlling the differentiation of ES cells within the EB. Existing methods of formation of EBs, however, are tedious or provide heterogeneously-sized EBs. Here we describe a microfluidic system for straightforward synchronized formation of uniform-sized EBs, the size of which can be controlled by changing the cross-sectional size of microchannels in the microfluidic device. The device consists of two microchannels separated by a semi-porous polycarbonate membrane treated to be resistant to cell adhesion. ES cells introduced into the upper channel self-aggregate to form uniformly-sized EBs. The semi-porous membrane also allows subsequent treatment of the non-attached EBs with different reagents from the lower channel without the need for wash out because of the compartmentalization afforded by the membrane. This method provides a simple yet robust means to control the formation of EBs and the subsequent differentiation of ES cells in a format compatible for ES cell processing on a chip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilineage differentiation from human embryonic stem cell lines
Odorico, J. S., Kaufman, D. S., & Thomson, J. A. (2001) · Stem Cells · doi:10.1634/stemcells.19-3-193 · Cited by 969
Kelm, J. M., Timmins, N. E., Brown, C. J., Fussenegger, M., & Nielsen, L. K. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10655 · Cited by 934
Cited by
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Self-citationMulticellular tumor spheroids: An underestimated tool is catching up again
Hirschhaeuser, F., Menne, H., Dittfeld, C., West, J., Mueller-Klieser, W., & Kunz-Schughart, L. A. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.01.012 · Cited by 1,674
Opportunities and challenges for use of tumor spheroids as models to test drug delivery and efficacy
Mehta, G., Hsiao, A. Y., Ingram, M., Luker, G. D., & Takayama, S. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.04.045 · Cited by 1,172
“Reproduced from [50] by permission of The Royal Society of Chemistry.”
Self-citationSpheroid culture as a tool for creating 3D complex tissues
Fennema, E., Rivron, N., Rouwkema, J., van Blitterswijk, C., & de Boer, J. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2012.12.003 · Cited by 1,054
High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array
Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-S., Ho, M., & Takayama, S. (2011) · The Analyst · doi:10.1039/c0an00609b · Cited by 969
Self-citationA multi-layer microfluidic device for efficient culture and analysis of renal tubular cells
Jang, K.-J., & Suh, K.-Y. (2010) · Lab Chip · doi:10.1039/b907515a · Cited by 497
Hwang, Y.-S., Chung, B. G., Ortmann, D., Hattori, N., Moeller, H.-C., & Khademhosseini, A. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0905550106 · Cited by 397
Cell Culture Models in Microfluidic Systems
Meyvantsson, I., & Beebe, D. J. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113042 · Cited by 345
Laser-based direct-write techniques for cell printing
Schiele, N. R., Corr, D. T., Huang, Y., Raof, N. A., Xie, Y., & Chrisey, D. B. (2010) · Biofabrication · doi:10.1088/1758-5082/2/3/032001 · Cited by 334
Microfluidic system for formation of PC-3 prostate cancer co-culture spheroids
Hsiao, A. Y., Torisawa, Y.-S., Tung, Y.-C., Sud, S., Taichman, R. S., Pienta, K. J., & Takayama, S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.02.047 · Cited by 323
Self-citationEngineering cancer microenvironments for in vitro 3-D tumor models
Asghar, W., El Assal, R., Shafiee, H., Pitteri, S., Paulmurugan, R., & Demirci, U. (2015) · Materials Today · doi:10.1016/j.mattod.2015.05.002 · Cited by 316
Molding Cell Beads for Rapid Construction of Macroscopic 3D Tissue Architecture
Matsunaga, Y. T., Morimoto, Y., & Takeuchi, S. (2011) · Advanced Materials · doi:10.1002/adma.201004375 · Cited by 308
Engineering the embryoid body microenvironment to direct embryonic stem cell differentiation
Bratt‐Leal, A. M., Carpenedo, R. L., & McDevitt, T. C. (2009) · Biotechnology Progress · doi:10.1002/btpr.139 · Cited by 271
Moshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
“were connected to microchannels within the other layer using the porous membrane [156, 157].”
MethodControlled-size embryoid body formation in concave microwell arrays
Choi, Y. Y., Chung, B. G., Lee, D. H., Khademhosseini, A., Kim, J.-H., & Lee, S.-H. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.115 · Cited by 252
Microfluidic devices for cell cultivation and proliferation
Tehranirokh, M., Kouzani, A. Z., Francis, P. S., & Kanwar, J. R. (2013) · Biomicrofluidics · doi:10.1063/1.4826935 · Cited by 202
Tumor stroma-containing 3D spheroid arrays: A tool to study nanoparticle penetration
Priwitaningrum, D. L., Blondé, J.-B. G., Sridhar, A., van Baarlen, J., Hennink, W. E., Storm, G., Le Gac, S., & Prakash, J. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.09.004 · Cited by 172
“Various platforms have been proposed for generating 3D cell models and for 3D cell cultures, using scaffolds based on different polymers [28], hydrogels [29], microwell arrays [30], hanging drop method [31], and microfluidic devices [32], or combinations thereof [33].”
MethodPatra, B., Chen, Y.-H., Peng, C.-C., Lin, S.-C., Lee, C.-H., & Tung, Y.-C. (2013) · Biomicrofluidics · doi:10.1063/1.4824480 · Cited by 109
In vitro spatially organizing the differentiation in individual multicellular stem cell aggregates
Qi, H., Huang, G., Han, Y. L., Lin, W., Li, X., Wang, S., Lu, T. J., & Xu, F. (2016) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2014.922917 · Cited by 26
“…2006; Lee et al., 2010; Moeller et al., 2008; Mohr et al., 2006, 2010), surface patterning (Bauwens et al., 2008; De Bank et al., 2003, 2007; Gothard et al., 2009; Lee et al., 2009; Park et al., 2007; Peerani et al., 2007; Ungrin et al., 2008) and microchannel compartments (Torisawa et al., 2007).”
Background
Metadata
- Authors
- Torisawa, Y.-S., Chueh, B.-H., Huh, D., Ramamurthy, P., Roth, T. M., Barald, K. F., & Takayama, S.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 6
- Pages
- 770
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2076159213
- Cited by
- 144
- References
- 2
- FWCI
- 8.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.