The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Abstract
Micro- and nanoelectromechanical systems, including cantilevers and other small scale structures, have been studied for sensor applications. Accurate sensing of gaseous or aqueous environments, chemical vapors, and biomolecules have been demonstrated using a variety of these devices that undergo static deflections or shifts in resonant frequency upon analyte binding. In particular, biological detection of viruses, antigens, DNA, and other proteins is of great interest. While the majority of currently used detection schemes are reliant on biomarkers, such as fluorescent labels, time, effort, and chemical activity could be saved by developing an ultrasensitive method of label-free mass detection. Micro- and nanoscale sensors have been effectively applied as label-free detectors. In the following, we review the technologies and recent developments in the field of micro- and nanoelectromechanical sensors with particular emphasis on their application as biological sensors and recent work towards integrating these sensors in microfluidic systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Surface plasmon resonance sensors: review
Homola, J., Yee, S. S., & Gauglitz, G. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00321-9 · Cited by 5,453
The tension of metallic films deposited by electrolysis
Stoney, G. G. (1909) · Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character · doi:10.1098/rspa.1909.0021 · Cited by 4,872
Vibration problems in engineering
Timoshenko, S. P. (1928) · CERN Document Server (European Organization for Nuclear Research) · Cited by 3,449
Electromechanical Resonators from Graphene Sheets
Bunch, J. S., van der Zande, A. M., Verbridge, S. S., Frank, I. W., Tanenbaum, D. M., Parpia, J. M., Craighead, H. G., & McEuen, P. L. (2007) · Science · doi:10.1126/science.1136836 · Cited by 2,886
Self-citationTranslating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Craighead, H. G. (2000) · Science · doi:10.1126/science.290.5496.1532 · Cited by 1,437
Self-citationEkinci, K. L., & Roukes, M. L. (2005) · Review of Scientific Instruments · doi:10.1063/1.1927327 · Cited by 1,374
Weighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Cited by
3D Printing of Interdigitated Li‐Ion Microbattery Architectures
Sun, K., Wei, T., Ahn, B. Y., Seo, J. Y., Dillon, S. J., & Lewis, J. A. (2013) · Advanced Materials · doi:10.1002/adma.201301036 · Cited by 1,341
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Titanium Dioxide Nanomaterials for Sensor Applications
Bai, J., & Zhou, B. (2014) · Chemical Reviews · doi:10.1021/cr400625j · Cited by 900
Cantilever-like micromechanical sensors
Boisen, A., Dohn, S., Keller, S. S., Schmid, S., & Tenje, M. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/3/036101 · Cited by 566
Vollmer, F., & Yang, L. (2012) · nanoph · doi:10.1515/nanoph-2012-0021 · Cited by 546
Eom, K., Park, H. S., Yoon, D. S., & Kwon, T. (2011) · Physics Reports · doi:10.1016/j.physrep.2011.03.002 · Cited by 464
Biosensors based on nanomechanical systems
Tamayo, J., Kosaka, P. M., Ruz, J. J., San Paulo, Á., & Calleja, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35293a · Cited by 391
Longo, G., Alonso-Sarduy, L., Rio, L. M., Bizzini, A., Trampuz, A., Notz, J., Dietler, G., & Kasas, S. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.120 · Cited by 368
Towards on-site pathogen detection using antibody-based sensors
Skottrup, P. D., Nicolaisen, M., & Justesen, A. F. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.06.045 · Cited by 352
Biosensing using dynamic-mode cantilever sensors: A review
Johnson, B. N., & Mutharasan, R. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.054 · Cited by 314
Pires, N., Dong, T., Hanke, U., & Hoivik, N. (2014) · Sensors · doi:10.3390/s140815458 · Cited by 307
Metal nanoparticles in liquid phase catalysis; from recent advances to future goals
Zahmakıran, M., & Özkar, S. (2011) · Nanoscale · doi:10.1039/c1nr10201j · Cited by 299
Fungal disease detection in plants: Traditional assays, novel diagnostic techniques and biosensors
Ray, M., Ray, A., Dash, S., Mishra, A., Achary, K. G., Nayak, S., & Singh, S. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.032 · Cited by 272
Review of Gravimetric Sensing of Volatile Organic Compounds
McGinn, C. K., Lamport, Z. A., & Kymissis, I. (2020) · ACS Sensors · doi:10.1021/acssensors.0c00333 · Cited by 152
Chen, Y., Xu, P., Li, X., Ren, Y., & Deng, Y. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.03.180 · Cited by 75
Metadata
- Authors
- Waggoner, P. S., & Craighead, H. G.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 10
- Pages
- 1238
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2138308932
- Cited by
- 678
- References
- 58
- FWCI
- 43.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.