The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Digital microfluidics for cell-based assays
Abstract
We introduce a new method for implementing cell-based assays. The method is based on digital microfluidics (DMF) which is used to actuate nanolitre droplets of reagents and cells on a planar array of electrodes. We demonstrate that this method is advantageous for cell-based assays because of automated manipulation of multiple reagents in addition to reduced reagent use and analysis time. No adverse effects of actuation by DMF were observed in assays for cell viability, proliferation, and biochemistry. A cytotoxicity assay using Jurkat T-cells was performed using the new method, which had approximately 20 times higher sensitivity than a conventional well plate assay. These results suggest that DMF has great potential as a simple yet versatile analytical tool for implementing cell-based assays on the microscale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Electrowetting-based actuation of liquid droplets for microfluidic applications
Pollack, M. G., Fair, R. B., & Shenderov, A. D. (2000) · Applied Physics Letters · doi:10.1063/1.1308534 · Cited by 1,481
Srinivasan, V., Pamula, V. K., & Fair, R. B. (2004) · Lab on a Chip · doi:10.1039/b403341h · Cited by 1,066
Li Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
Generation of Gradients Having Complex Shapes Using Microfluidic Networks
Dertinger, S. K. W., Chiu, D. T., Jeon, N. L., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac001132d · Cited by 839
Electrowetting and electrowetting-on-dielectric for microscale liquid handling
Lee, J., Moon, H., Fowler, J., Schoellhammer, T., & Kim, C.-J. (2002) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00734-8 · Cited by 652
Microfluidic Device for Single-Cell Analysis
Wheeler, A. R., Throndset, W. R., Whelan, R. J., Leach, A. M., Zare, R. N., Liao, Y. H., Farrell, K., Manger, I. D., & Daridon, A. (2003) · Analytical Chemistry · doi:10.1021/ac0340758 · Cited by 600
Self-citationSubcellular positioning of small molecules
Takayama, S., Ostuni, E., LeDuc, P., Naruse, K., Ingber, D. E., & Whitesides, G. M. (2001) · Nature · doi:10.1038/35082637 · Cited by 545
Continuous perfusion microfluidic cell culture array for high‐throughput cell‐based assays
Hung, P. J., Lee, P. J., Sabounchi, P., Lin, R., & Lee, L. P. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20289 · Cited by 522
An Integrated Microfabricated Cell Sorter
Fu, A. Y., Chou, H.-P., Spence, C., Arnold, F. H., & Quake, S. R. (2002) · Analytical Chemistry · doi:10.1021/ac0255330 · Cited by 510
Transport, Manipulation, and Reaction of Biological Cells On-Chip Using Electrokinetic Effects
Li, P. C. H., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606564 · Cited by 422
Microfluidic Devices for the High-Throughput Chemical Analysis of Cells
McClain, M. A., Culbertson, C. T., Jacobson, S. C., Allbritton, N. L., Sims, C. E., & Ramsey, J. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346510 · Cited by 383
Amiji, M., & Park, K. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90128-b · Cited by 359
On-chip manipulation of free droplets
Velev, O. D., Prevo, B. G., & Bhatt, K. H. (2003) · Nature · doi:10.1038/426515a · Cited by 354
Integrated polymerase chain reaction chips utilizing digital microfluidics
Chang, Y.-H., Lee, G.-B., Huang, F.-C., Chen, Y.-Y., & Lin, J.-L. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-8171-y · Cited by 324
Schilling, E. A., Kamholz, A. E., & Yager, P. (2002) · Analytical Chemistry · doi:10.1021/ac015640e · Cited by 299
Moon, H., Wheeler, A. R., Garrell, R. L., Loo, J. A., & Kim, C.-J. ?. (2006) · Lab on a Chip · doi:10.1039/b601954d · Cited by 296
Self-citationWheeler, A. R., Moon, H., Kim, C.-J. “., Loo, J. A., & Garrell, R. L. (2004) · Analytical Chemistry · doi:10.1021/ac0498112 · Cited by 262
Self-citationDigital Microfluidics with In-Line Sample Purification for Proteomics Analyses with MALDI-MS
Wheeler, A. R., Moon, H., Bird, C. A., Ogorzalek Loo, R. R., Kim, C.-J. “. J. ”., Loo, J. A., & Garrell, R. L. (2005) · Analytical Chemistry · doi:10.1021/ac048754+ · Cited by 255
Self-citationCell-based high content screening using an integrated microfluidic device
Ye, N., Qin, J., Shi, W., Liu, X., & Lin, B. (2007) · Lab on a Chip · doi:10.1039/b711513j · Cited by 246
Pluronic Additives: A Solution to Sticky Problems in Digital Microfluidics
Luk, V. N., Mo, G. C., & Wheeler, A. R. (2008) · Langmuir · doi:10.1021/la7039509 · Cited by 227
Self-citationHigh-density microfluidic arrays for cell cytotoxicity analysis
Wang, Z., Kim, M.-C., Marquez, M., & Thorsen, T. (2007) · Lab on a Chip · doi:10.1039/b618734j · Cited by 214
Microfabricated platform for studying stem cell fates
Chin, V. I., Taupin, P., Sanga, S., Scheel, J., Gage, F. H., & Bhatia, S. N. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20254 · Cited by 202
Portable cell-based biosensor system using integrated CMOS cell-cartridges
DeBusschere, B. D., & Kovacs, G. T. A. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00168-3 · Cited by 174
A Digital Microfluidic Approach to Homogeneous Enzyme Assays
Miller, E. M., & Wheeler, A. R. (2008) · Analytical Chemistry · doi:10.1021/ac702269d · Cited by 167
Self-citationPerfusion and chemical monitoring of living cells on a microfluidic chip
Shackman, J. G., Dahlgren, G. M., Peters, J. L., & Kennedy, R. T. (2004) · Lab on a Chip · doi:10.1039/b404974h · Cited by 144
Morin, F. O., Nishimura, N., Griscom, L., Pioufle, B. L., Fujita, H., Takamura, Y., & Tamiya, E. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.04.020 · Cited by 135
Verkman, A. S. (2004) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00397.2003 · Cited by 126
Yap, B., & Kamm, R. D. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01226.2004 · Cited by 109
Moehlenbrock, M. J., Price, A. K., & Martin, R. S. (2006) · The Analyst · doi:10.1039/b605136g · Cited by 51
A plate reader-compatible microchannel array for cell biology assays
Yu, H., Alexander, C. M., & Beebe, D. J. (2007) · Lab on a Chip · doi:10.1039/b612358a · Cited by 44
Cited by
Choi, K., Ng, A. H. C., Fobel, R., & Wheeler, A. R. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143028 · Cited by 817
Self-citationEngineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
A review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
The Digital Revolution: A New Paradigm for Microfluidics
Abdelgawad, M., & Wheeler, A. R. (2009) · Advanced Materials · doi:10.1002/adma.200802244 · Cited by 382
Self-citationActive droplet sorting in microfluidics: a review
Xi, H.-D., Zheng, H., Guo, W., Gañán-Calvo, A. M., Ai, Y., Tsao, C.-W., Zhou, J., Li, W., Huang, Y., Nguyen, N.-T., et al. (2017) · Lab on a Chip · doi:10.1039/c6lc01435f · Cited by 369
Metadata
- Authors
- Barbulovic-Nad, I., Yang, H., Park, P. S., & Wheeler, A. R.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 4
- Pages
- 519
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2065075903
- Cited by
- 337
- References
- 34
- FWCI
- 23.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.