The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Microfluidic sample preparation: cell lysis and nucleic acid purification
Abstract
Due to the lack of development in the area of sample preparation, few complete lab-on-a-chip systems have appeared in recent years that can deal with raw samples. Cell lysis and nucleic acid extraction systems are sufficiently complex even before adding the complexity of an analysis system. In this review, a variety of microfluidic sample preparation methods are discussed and evaluated. Microsystems for cell lysis are discussed by grouping them into categories based on their lysis mechanisms: mechanical, chemical, thermal or electrical. We classify the nucleic acid purification techniques according to the mechanism that links nucleic acids to substrates: silica-based surface affinity, electrostatic interaction, nanoporous membrane filtration, and functionalized microparticles. The techniques for microfluidic cell lysis and nucleic acid purification are compared based on the ease of microfabrication and integration, and sample flexibility. These assessments can help us determine the appropriate sample preparation technique for generating a true lab-on-a-chip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Cloning: A Laboratory Manual
Sambrook, J., Fritsch, E., & Maniatis, T. (1989) · UCLA - Biblioteca de Ciencias de la Salud · Cited by 133,589
Isolation of biologically active ribonucleic acid from sources enriched in ribonuclease
Chirgwin, J. M., Przybyla, A. E., MacDonald, R. J., & Rutter, W. J. (1979) · Biochemistry · doi:10.1021/bi00591a005 · Cited by 21,725
Nanotube Molecular Wires as Chemical Sensors
Kong, J., Franklin, N. R., Zhou, C., Chapline, M. G., Peng, S., Cho, K., & Dai, H. (2000) · Science · doi:10.1126/science.287.5453.622 · Cited by 6,043
Rapid and simple method for purification of nucleic acids
Boom, R., Sol, C. J., Salimans, M. M., Jansen, C. L., Wertheim-van Dillen, P. M., & van der Noordaa, J. (1990) · Journal of Clinical Microbiology · doi:10.1128/jcm.28.3.495-503.1990 · Cited by 5,266
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Dekker, C. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.27 · Cited by 1,933
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
Effects of high electric fields on microorganismsI. Killing of bacteria and yeasts
SALE, A., & HAMILTON, W. (1967) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(67)90052-9 · Cited by 784
Guide to Electroporation and Electrofusion
(1992) · Elsevier eBooks · doi:10.1016/c2009-0-21564-9 · Cited by 634
A fully integrated microfluidic genetic analysis system with sample-in–answer-out capability
Easley, C. J., Karlinsey, J. M., Bienvenue, J. M., Legendre, L. A., Roper, M. G., Feldman, S. H., Hughes, M. A., Hewlett, E. L., Merkel, T. J., Ferrance, J. P., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604663103 · Cited by 547
Label-free detection of small-molecule–protein interactions by using nanowire nanosensors
Wang, W. U., Chen, C., Lin, K.-H., Fang, Y., & Lieber, C. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406368102 · Cited by 534
Killing of microorganisms by pulsed electric fields
Grahl, T., & Märkl, H. (1996) · Applied Microbiology and Biotechnology · doi:10.1007/s002530050663 · Cited by 532
Neutral Salts: The Generality of Their Effects on the Stability of Macromolecular Conformations
von Hippel, P. H., & Wong, K.-Y. (1964) · Science · doi:10.1126/science.145.3632.577 · Cited by 481
Bunimovich, Y. L., Shin, Y. S., Yeo, W.-S., Amori, M., Kwong, G., & Heath, J. R. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065923u · Cited by 480
A nanoliter-scale nucleic acid processor with parallel architecture
Hong, J. W., Studer, V., Hang, G., Anderson, W. F., & Quake, S. R. (2004) · Nature Biotechnology · doi:10.1038/nbt951 · Cited by 470
Ziegler, C. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2694-y · Cited by 414
Microfluidic Devices for the High-Throughput Chemical Analysis of Cells
McClain, M. A., Culbertson, C. T., Jacobson, S. C., Allbritton, N. L., Sims, C. E., & Ramsey, J. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346510 · Cited by 383
Effects of high electric fields on microorganismsII. Mechanism of action of the lethal effect
HAMILTON, W., & SALE, A. (1967) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(67)90053-0 · Cited by 361
Microchip-Based Purification of DNA from Biological Samples
Breadmore, M. C., Wolfe, K. A., Arcibal, I. G., Leung, W. K., Dickson, D., Giordano, B. C., Power, M. E., Ferrance, J. P., Feldman, S. H., Norris, P. M., et al. (2003) · Analytical Chemistry · doi:10.1021/ac0204855 · Cited by 351
Surface plasmon resonance: principles, methods and applications in biomedical sciences
Englebienne, P., Hoonacker, A. V., & Verhas, M. (2003) · Journal of Spectroscopy · doi:10.1155/2003/372913 · Cited by 348
Cheng, J., Sheldon, E. L., Wu, L., Uribe, A., Gerrue, L. O., Carrino, J., Heller, M. J., & O'Connell, J. P. (1998) · Nature Biotechnology · doi:10.1038/nbt0698-541 · Cited by 347
One-step pathogen specific DNA extraction from whole blood on a centrifugal microfluidic device
Cho, Y.-K., Lee, J.-G., Park, J.-M., Lee, B.-S., Lee, Y., & Ko, C. (2007) · Lab on a Chip · doi:10.1039/b616115d · Cited by 312
Rapid and label-free nanomechanical detection of biomarker transcripts in human RNA
Zhang, J., Lang, H. P., Huber, F., Bietsch, A., Grange, W., Certa, U., Mckendry, R., Güntherodt, H.-J., Hegner, M., & Gerber, C. (2006) · Nature Nanotechnology · doi:10.1038/nnano.2006.134 · Cited by 303
Gao, J., Yin, X.-F., & Fang, Z.-L. (2004) · Lab on a Chip · doi:10.1039/b310552k · Cited by 300
Schilling, E. A., Kamholz, A. E., & Yager, P. (2002) · Analytical Chemistry · doi:10.1021/ac015640e · Cited by 299
Sample Preparation: Quo Vadis?
Pawliszyn, J. (2003) · Analytical Chemistry · doi:10.1021/ac034094h · Cited by 287
Reagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation
Carlo, D. D., Jeong, K.-H., & Lee, L. P. (2003) · Lab on a Chip · doi:10.1039/b305162e · Cited by 246
DNA purification and isolation using a solid-phase
Hawkins, T. L., O‘Connor-Morin, T., Roy, A., & Santillan, C. (1994) · Nucleic Acids Research · doi:10.1093/nar/22.21.4543 · Cited by 225
Nucleic acid purification using microfabricated silicon structures
Cady, N. C., Stelick, S., & Batt, C. A. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00123-4 · Cited by 220
Focus. Dealing with ‘real’ samples: sample pre-treatment in microfluidic systems
de Mello, A. J., & Beard, N. (2003) · Lab Chip · doi:10.1039/b301019h · Cited by 207
Nguyen, B., Tanious, F. A., & Wilson, W. D. (2007) · Methods · doi:10.1016/j.ymeth.2006.09.009 · Cited by 203
Rau, K. R., Quinto-Su, P. A., Hellman, A. N., & Venugopalan, V. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.079921 · Cited by 186
Continuous flow microfluidic device for cell separation, cell lysis and DNA purification
Chen, X., Cui, D., Liu, C., Li, H., & Chen, J. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.11.057 · Cited by 185
Mahalanabis, M., Al-Muayad, H., Kulinski, M. D., Altman, D., & Klapperich, C. M. (2009) · Lab on a Chip · doi:10.1039/b905065p · Cited by 178
A Minisonicator To Rapidly Disrupt Bacterial Spores for DNA Analysis
Belgrader, P., Hansford, D., Kovacs, G. T. A., Venkateswaran, K., Mariella, Milanovich, F., Nasarabadi, S., Okuzumi, M., Pourahmadi, F., & Northrup, M. A. (1999) · Analytical Chemistry · doi:10.1021/ac990347o · Cited by 170
Christel, L. A., Petersen, K., McMillan, W., & Northrup, M. A. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798037 · Cited by 160
Anomalous resonance in a nanomechanical biosensor
Gupta, A. K., Nair, P. R., Akin, D., Ladisch, M. R., Broyles, S., Alam, M. A., & Bashir, R. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602022103 · Cited by 160
Cell lysis on a microfluidic CD (compact disc)
Kim, J.-T., Jang, S. H., Jia, G., Zoval, J. V., Silva, N. A. D., & Madou, M. J. (2004) · Lab on a Chip · doi:10.1039/b401106f · Cited by 151
Self-citationA DNA biochip for on-the-spot multiplexed pathogen identification
Yeung, S. W., Lee, T. M. H., Cai, H. N., & Hsing, I. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkl702 · Cited by 134
A novel, compact disk-like centrifugal microfluidics system for cell lysis and sample homogenization
Kido, H., Mićić, M., Smith, D., Zoval, J. V., Norton, J., & Madou, M. J. (2007) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2007.03.015 · Cited by 130
Heo, J., Thomas, K. J., Seong, G. H., & Crooks, R. M. (2002) · Analytical Chemistry · doi:10.1021/ac0259717 · Cited by 116
Integrated microfluidic cell culture and lysis on a chip
Nevill, J. T., Cooper, R. M., Dueck, M. E., Breslauer, D. N., & Lee, L. P. (2007) · Lab on a Chip · doi:10.1039/b711874k · Cited by 113
Cell Stimulus and Lysis in a Microfluidic Device with Segmented Gas−Liquid Flow
El-Ali, J., Gaudet, S., Günther, A., Sorger, P. K., & Jensen, K. F. (2005) · Analytical Chemistry · doi:10.1021/ac050008x · Cited by 95
Microfluidic biomechanical device for compressive cell stimulation and lysis
Kim, Y. C., Kang, J. H., Park, S.-J., Yoon, E.-S., & Park, J. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.05.050 · Cited by 71
Microfluidic System for Detection of α-Thalassemia-1 Deletion Using Saliva Samples
Lien, K.-Y., Liu, C.-J., Kuo, P., & Lee, G. (2009) · Analytical Chemistry · doi:10.1021/ac900453d · Cited by 55
Selection of surfactants for cell lysis in chemical cytometry to study protein‐DNA interactions
Pang, Z., Al‐Mahrouki, A., Berezovski, M. V., & Krylov, S. N. (2006) · Electrophoresis · doi:10.1002/elps.200500732 · Cited by 26
Extraction and Amplification of Genomic DNA from Human Blood on Nanoporous Aluminum Oxide Membranes
Elgort, M., Herrmann, M. G., Erali, M., Durtschi, J., Voelkerding, K. V., & Smith, R. E. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.035162 · Cited by 25
Kokoris, M. S., Nabavi, M., Lancaster, C. A., et al. (2005) · Methods · doi:10.1016/j.ymeth.2005.07.002 · Cited by 22
Genome-wide transcriptome analysis of 150 cell samples
Irimia, D., Mindrinos, M. N., Russom, A., Xiao, W., Wilhelmy, J., Wang, S., Heath, J. D., Kurn, N., Tompkins, R. G., Davis, R. W., et al. (2008) · Integrative Biology · doi:10.1039/b814329c · Cited by 18
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
Current Nucleic Acid Extraction Methods and Their Implications to Point-of-Care Diagnostics
Ali, N., Rampazzo, R. D. C. P., Costa, A. D. T., & Krieger, M. A. (2017) · BioMed Research International · doi:10.1155/2017/9306564 · Cited by 359
Metadata
- Authors
- Kim, J., Johnson, M., Hill, P., & Gale, B. K.
- Venue
- Integrative Biology
- Publisher
- Oxford University Press (OUP)
- Published
- 2009
- Volume
- 1
- Issue
- 10
- Pages
- 574
- ISSN
- 1757-9694 (ISSN-L)
- 1757-9708
- OpenAlex
- W2045145170
- Cited by
- 282
- References
- 51
- FWCI
- 10.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.