The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Desorption electrospray ionization and other ambient ionization methods: current progress and preview
Abstract
Mass spectrometry allows rapid chemical analysis of untreated samples in the ambient environment. This is a result of recent rapid progress in ambient ionization techniques. The most widely studied of these new methods, desorption electrospray ionization (DESI), uses fast-moving solvent droplets to extract analytes from surfaces and propel the resulting secondary microdroplets towards the mass analyzer. This review of DESI and other ambient methods centers on the accompanying chemical processes. Manipulation of the chemistry accompanying ambient ionization can be used to optimize chemical analysis, including molecular imaging. Solvent effects, geometry effects, electrochemical processes and mechanisms are covered. Extensions of the methodology to solution-phase analysis, to stand-off detection and to therapeutic drug analysis using miniature mass spectrometers are also treated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Self-citationVersatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions
Cody, R. B., Laramée, J. A., & Durst, H. D. (2005) · Analytical Chemistry · doi:10.1021/ac050162j · Cited by 2,483
Cooks, R. G., Ouyang, Z., Takats, Z., & Wiseman, J. M. (2006) · Science · doi:10.1126/science.1119426 · Cited by 1,474
Self-citationTakáts, Z., Wiseman, J. M., & Cooks, R. G. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.922 · Cited by 880
Self-citationNemes, P., & Vertes, A. (2007) · Analytical Chemistry · doi:10.1021/ac071181r · Cited by 817
Paper Spray for Direct Analysis of Complex Mixtures Using Mass Spectrometry
Wang, H., Liu, J., Cooks, R. G., & Ouyang, Z. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906314 · Cited by 771
Self-citationLow-Temperature Plasma Probe for Ambient Desorption Ionization
Harper, J. D., Charipar, N. A., Mulligan, C. C., Zhang, X., Cooks, R. G., & Ouyang, Z. (2008) · Analytical Chemistry · doi:10.1021/ac801641a · Cited by 730
Self-citationDevelopment, Characterization, and Application of Paper Spray Ionization
Liu, J., Wang, H., Manicke, N. E., Lin, J.-M., Cooks, R. G., & Ouyang, Z. (2010) · Analytical Chemistry · doi:10.1021/ac902854g · Cited by 711
Self-citationAmbient desorption ionization mass spectrometry
Venter, A., Nefliu, M., & Graham Cooks, R. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.01.010 · Cited by 552
Shiea, J., Huang, M., HSu, H., Lee, C., Yuan, C., Beech, I., & Sunner, J. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2243 · Cited by 481
Latent Fingerprint Chemical Imaging by Mass Spectrometry
Ifa, D. R., Manicke, N. E., Dill, A. L., & Cooks, R. G. (2008) · Science · doi:10.1126/science.1157199 · Cited by 407
Self-citationDroplet Dynamics and Ionization Mechanisms in Desorption Electrospray Ionization Mass Spectrometry
Venter, A., Sojka, P. E., & Cooks, R. G. (2006) · Analytical Chemistry · doi:10.1021/ac0615807 · Cited by 361
Self-citationWeston, D. J. (2010) · The Analyst · doi:10.1039/b925579f · Cited by 357
In Vivo, In Situ Tissue Analysis Using Rapid Evaporative Ionization Mass Spectrometry
Schäfer, K., Dénes, J., Albrecht, K., Szaniszló, T., Balog, J., Skoumal, R., Katona, M., Tóth, M., Balogh, L., & Takáts, Z. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200902546 · Cited by 334
Ouyang, Z., & Cooks, R. G. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155229 · Cited by 323
Self-citationVan Berkel, G. J., Pasilis, S. P., & Ovchinnikova, O. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1440 · Cited by 299
Ifa, D. R., Wiseman, J. M., Song, Q., & Cooks, R. G. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.08.003 · Cited by 261
Self-citationGao, L., Cooks, R. G., & Ouyang, Z. (2008) · Analytical Chemistry · doi:10.1021/ac800014v · Cited by 258
Self-citationWu, C., Ifa, D. R., Manicke, N. E., & Cooks, R. G. (2009) · Analytical Chemistry · doi:10.1021/ac901003u · Cited by 238
Self-citationRatcliffe, L., Rutten, F. J. M., Barrett, D. A., Whitmore, T. D., Seymour, D. L., Greenwood, C., Gonzalvo, Y. A., Robinson, S., & McCoustra, M. R. S. (2007) · Analytical Chemistry · doi:10.1021/ac070109q · Cited by 231
Weston, D. J., Bateman, R., Wilson, I. D., Wood, T. R., & Creaser, C. S. (2005) · Analytical Chemistry · doi:10.1021/ac051277q · Cited by 224
Nemes, P., Barton, A. A., & Vertes, A. (2009) · Analytical Chemistry · doi:10.1021/ac900745e · Cited by 223
Lane, A. L., Nyadong, L., Galhena, A. S., Shearer, T. L., Stout, E. P., Parry, R. M., Kwasnik, M., Wang, M. D., Hay, M. E., Fernandez, F. M., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0812020106 · Cited by 220
Costa, A. B., & Graham Cooks, R. (2008) · Chemical Physics Letters · doi:10.1016/j.cplett.2008.08.020 · Cited by 216
Rapid Screening of Anabolic Steroids in Urine by Reactive Desorption Electrospray Ionization
Huang, G., Chen, H., Zhang, X., Cooks, R. G., & Ouyang, Z. (2007) · Analytical Chemistry · doi:10.1021/ac0711079 · Cited by 201
Self-citationEberlin, L. S., Ifa, D. R., Wu, C., & Cooks, R. G. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906283 · Cited by 187
Self-citationKertesz, V., Van Berkel, G. J., Vavrek, M., Koeplinger, K. A., Schneider, B. B., & Covey, T. R. (2008) · Analytical Chemistry · doi:10.1021/ac800546a · Cited by 171
Cotte-Rodríguez, I., Chen, H., & Cooks, R. G. (2006) · Chemical Communications · doi:10.1039/b515122h · Cited by 161
Self-citationElectrochemistry Combined Online with Electrospray Mass Spectrometry
Zhou, F., & Van Berkel, G. J. (1995) · Analytical Chemistry · doi:10.1021/ac00116a005 · Cited by 161
cis-Diol functional group recognition by reactive desorption electrospray ionization (DESI)
Chen, H., Cotte-Rodríguez, I., & Cooks, R. G. (2006) · Chemical Communications · doi:10.1039/b516448f · Cited by 149
Self-citationImproved imaging resolution in desorption electrospray ionization mass spectrometry
Kertész, V., & Berkel, G. J. V. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3662 · Cited by 149
Dill, A. L., Ifa, D. R., Manicke, N. E., Costa, A. B., Ramos, J. A., Knapp, D. W., & Cooks, R. G. (2009) · Analytical Chemistry · doi:10.1021/ac901028b · Cited by 134
Self-citationAmbient imaging mass spectrometry by electrospray ionization using solid needle as sampling probe
Chen, L. C., Yoshimura, K., Yu, Z., Iwata, R., Ito, H., Suzuki, H. R., Mori, K., Ariyada, O., Takeda, S., Kubota, T., et al. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1632 · Cited by 114
Salt tolerance of desorption electrospray ionization (DESI)
Jackson, A. U., Talaty, N. N., Cooks, R. G., & Berkel, G. J. V. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.09.018 · Cited by 100
Self-citationMolecular imaging of adrenal gland by desorption electrospray ionization mass spectrometry
Wu, C., Ifa, D. R., Manicke, N. E., & Cooks, R. G. (2009) · The Analyst · doi:10.1039/b919816d · Cited by 94
Self-citationNon-aqueous spray solvents and solubility effects in desorption electrospray ionization
Badu-Tawiah, A. K., Bland, C., Campbell, D. I., & Cooks, R. G. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.12.012 · Cited by 89
Self-citationDirect analysis of curcumin in turmeric by DART‐MS
Kim, H. J., & Jang, Y. P. (2009) · Phytochemical Analysis · doi:10.1002/pca.1136 · Cited by 85
Electrospray ionization of volatiles in breath
Martínez-Lozano, P., & de la Mora, J. F. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.05.008 · Cited by 78
Surface effects and electrochemical cell capacitance in desorption electrospray ionization
Volný, M., Venter, A. R., Smith, S. A., Pazzi, M., & Cooks, R. G. (2008) · The Analyst · doi:10.1039/b717693g · Cited by 75
Self-citationZhang, Y., & Chen, H. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.09.015 · Cited by 72
Song, Y., & Cooks, R. G. (2007) · Journal of Mass Spectrometry · doi:10.1002/jms.1244 · Cited by 63
Self-citationFast and automated large-area imaging MALDI mass spectrometry in microprobe and microscope mode
Klerk, L. A., Altelaar, M. A. F., Froesch, M., McDonnell, L. A., & Heeren, R. M. A. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.02.032 · Cited by 42
Atmospheric pressure Eberlin transacetalization reactions in the heterogeneous liquid/gas phase
Augusti, R., Chen, H., Eberlin, L. S., Nefliu, M., & Cooks, R. G. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.05.005 · Cited by 30
Self-citation
Cited by
Ambient Sampling/Ionization Mass Spectrometry: Applications and Current Trends
Harris, G. A., Galhena, A. S., & Fernández, F. M. (2011) · Analytical Chemistry · doi:10.1021/ac200918u · Cited by 527
Ambient Ionization Mass Spectrometry: Recent Developments and Applications
Feider, C. L., Krieger, A., DeHoog, R. J., & Eberlin, L. S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00807 · Cited by 496
Mass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Self-citationMass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization
Monge, M. E., Harris, G. A., Dwivedi, P., & Fernández, F. M. (2013) · Chemical Reviews · doi:10.1021/cr300309q · Cited by 476
Weston, D. J. (2010) · The Analyst · doi:10.1039/b925579f · Cited by 357
Metadata
- Authors
- Ifa, D. R., Wu, C., Ouyang, Z., & Cooks, R. G.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 135
- Issue
- 4
- Pages
- 669
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2040677997
- Cited by
- 384
- References
- 43
- FWCI
- 22.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.