The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Programmable diagnostic devices made from paper and tape
Open accessAbstract
This paper describes three-dimensional microfluidic paper-based analytical devices (3-D microPADs) that can be programmed (postfabrication) by the user to generate multiple patterns of flow through them. These devices are programmed by pressing single-use 'on' buttons, using a stylus or a ballpoint pen. Pressing a button closes a small space (gap) between two vertically aligned microfluidic channels, and allows fluids to wick from one channel to the other. These devices are simple to fabricate, and are made entirely out of paper and double-sided adhesive tape. Programmable devices expand the capabilities of microPADs and provide a simple method for controlling the movement of fluids in paper-based channels. They are the conceptual equivalent of field-programmable gate arrays (FPGAs) widely used in electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Self-citationDiagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Self-citationUnderstanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Self-citationMartinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Self-citationThree-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
Self-citationElectrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Electrochemical sensing in paper-based microfluidic devices
Nie, Z., Nijhuis, C. A., Gong, J., Chen, X., Kumachev, A., Martinez, A. W., Narovlyansky, M., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b917150a · Cited by 929
Self-citationFPGA Design Methodology for Industrial Control Systems—A Review
Monmasson, E., & Cirstea, M. N. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.898281 · Cited by 908
Oh, K. W., & Ahn, C. H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/r01 · Cited by 838
Inkjet-Printed Microfluidic Multianalyte Chemical Sensing Paper
Abe, K., Suzuki, K., & Citterio, D. (2008) · Analytical Chemistry · doi:10.1021/ac800604v · Cited by 766
FLASH: A rapid method for prototyping paper-based microfluidic devices
Martinez, A. W., Phillips, S. T., Wiley, B. J., Gupta, M., & Whitesides, G. M. (2008) · Lab on a Chip · doi:10.1039/b811135a · Cited by 695
Self-citationLow-Cost Printing of Poly(dimethylsiloxane) Barriers To Define Microchannels in Paper
Bruzewicz, D. A., Reches, M., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac702605a · Cited by 616
Self-citationA simple artificial urine for the growth of urinary pathogens
Brooks, T., & Keevil, C. W. (1997) · Letters in Applied Microbiology · doi:10.1046/j.1472-765x.1997.00378.x · Cited by 528
Controlled reagent transport in disposable 2D paper networks
Fu, E., Lutz, B., Kauffman, P., & Yager, P. (2010) · Lab on a Chip · doi:10.1039/b919614e · Cited by 363
(2008) · Lab on a Chip · doi:10.1039/b814043j · Cited by 235
Metering the Capillary-Driven Flow of Fluids in Paper-Based Microfluidic Devices
Noh, H., & Phillips, S. T. (2010) · Analytical Chemistry · doi:10.1021/ac100431y · Cited by 203
Self-citationTorque-Actuated Valves for Microfluidics
Weibel, D. B., Kruithof, M., Potenta, S., Sia, S. K., Lee, A., & Whitesides, G. M. (2005) · Analytical Chemistry · doi:10.1021/ac048303p · Cited by 197
Self-citationPMMA/PDMS valves and pumps for disposable microfluidics
Zhang, W., Lin, S., Wang, C., Hu, J., Li, C., Zhuang, Z., Zhou, Y., Mathies, R. A., & Yang, C. J. (2009) · Lab on a Chip · doi:10.1039/b907254c · Cited by 183
Design and fabrication of chemically robust three-dimensional microfluidic valves
Maltezos, G., Garcia, E., Hanrahan, G., Gomez, F. A., Vyawhare, S., van Dam, R. M., Chen, Y., & Scherer, A. (2007) · Lab on a Chip · doi:10.1039/b705031c · Cited by 32
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
A perspective on paper-based microfluidics: Current status and future trends
Li, X., Ballerini, D. R., & Shen, W. (2012) · Biomicrofluidics · doi:10.1063/1.3687398 · Cited by 813
Metadata
- Authors
- Martinez, A. W., Phillips, S. T., Nie, Z., Cheng, C.-M., Carrilho, E., Wiley, B. J., & Whitesides, G. M.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 19
- Pages
- 2499
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2110438953
- Cited by
- 360
- References
- 19
- FWCI
- 15.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.