The DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Lab-on-a-chip based immunosensor principles and technologies for the detection of cardiac biomarkers: a review
Open accessAbstract
This review examines the current state of the art lab-on-a-chip and microfluidic based biosensor technologies used in the detection of cardiac biomarkers. The determination and quantification of blood based, cardiac biomarkers are crucial in the triage and management of a range of cardiac related conditions, where time delay has a major impact on short and longer-term outcomes of a patient. The design and manufacturing of biomarker detection systems are multi-disciplinary in nature and require researchers to have knowledge of both life sciences and engineering for the full potential of this field to be realised. This review will therefore provide a comprehensive overview of chip based immunosensing technology as applied to cardiac biomarker detection, while discussing the potential suitability and limitations of each configuration for incorporation within a clinical diagnostics device suitable for point-of-care applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probing Single Molecules and Single Nanoparticles by Surface-Enhanced Raman Scattering
Nie, S., & Emory, S. R. (1997) · Science · doi:10.1126/science.275.5303.1102 · Cited by 10,238
Surface-enhanced resonance Raman spectroscopy of Rhodamine 6G adsorbed on colloidal silver
Hildebrandt, P., & Stockburger, M. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150668a038 · Cited by 1,482
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
Buttry, D. A., & Ward, M. D. (1992) · Chemical Reviews · doi:10.1021/cr00014a006 · Cited by 1,375
Bioassay of prostate-specific antigen (PSA) using microcantilevers
Wu, G., Datar, R. H., Hansen, K. M., Thundat, T., Cote, R. J., & Majumdar, A. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-856 · Cited by 1,013
Electrochemical Biosensors: Recommended Definitions and Classification
Thevenot, D. R., Tóth, K., Durst, R. A., & Wilson, G. S. (1999) · Pure and Applied Chemistry · doi:10.1351/pac199971122333 · Cited by 909
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Surface acoustic wave biosensors: a review
Länge, K., Rapp, B. E., & Rapp, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1911-5 · Cited by 806
Grubisha, D. S., Lipert, R. J., Park, H.-Y., Driskell, J., & Porter, M. D. (2003) · Analytical Chemistry · doi:10.1021/ac034356f · Cited by 779
Troponin: the biomarker of choice for the detection of cardiac injury
Babuin, L., & Jaffe, A. S. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.050141 · Cited by 686
Multiplexed Toxin Analysis Using Four Colors of Quantum Dot Fluororeagents
Goldman, E. R., Clapp, A. R., Anderson, G. P., Uyeda, H. T., Mauro, J. M., Medintz, I. L., & Mattoussi, H. (2004) · Analytical Chemistry · doi:10.1021/ac035083r · Cited by 651
Advances in biosensors for detection of pathogens in food and water
Leonard, P., Hearty, S., Brennan, J., Dunne, L., Quinn, J. G., Chakraborty, T., & O’Kennedy, R. J. (2002) · Enzyme and Microbial Technology · doi:10.1016/s0141-0229(02)00232-6 · Cited by 605
Fatty acid-binding proteins as plasma markers of tissue injury
Pelsers, M. M. A. L., Hermens, W. T., & Glatz, J. F. C. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.09.001 · Cited by 488
Landesberg, G., Shatz, V., Akopnik, I., Wolf, Y. G., Mayer, M., Berlatzky, Y., Weissman, C., & Mosseri, M. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.05.001 · Cited by 486
Innovations in optical microfluidic technologies for point-of-care diagnostics
Myers, F. B., & Lee, L. P. (2008) · Lab on a Chip · doi:10.1039/b812343h · Cited by 474
NACB WRITING GROUP MEMBERS, Morrow, D. A., Cannon, C. P., Jesse, R. L., Newby, L. K., Ravkilde, J., Storrow, A. B., Wu, A. H. B., Christenson, R. H., NACB COMMITTEE MEMBERS, et al. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.084194 · Cited by 474
Mulvaney, S. P., Musick, M. D., Keating, C. D., & Natan, M. J. (2003) · Langmuir · doi:10.1021/la026706j · Cited by 457
Immunoassay Readout Method Using Extrinsic Raman Labels Adsorbed on Immunogold Colloids
Ni, J., Lipert, R. J., Dawson, G. B., & Porter, M. D. (1999) · Analytical Chemistry · doi:10.1021/ac990616a · Cited by 443
Magnetoresistive-based biosensors and biochips
Graham, D. L., Ferreira, H. A., & Freitas, P. P. (2004) · Trends in Biotechnology · doi:10.1016/j.tibtech.2004.06.006 · Cited by 435
Biosensing with Luminescent Semiconductor Quantum Dots
Sapsford, K. E., Pons, T., Medintz, I. L., & Mattoussi, H. (2006) · Sensors · doi:10.3390/s6080925 · Cited by 420
Surface Plasmon Resonance for Biosensing: A Mini-Review
Abdulhalim, I., Zourob, M., & Lakhtakia, A. (2008) · Electromagnetics · doi:10.1080/02726340801921650 · Cited by 410
Label-free protein assay based on a nanomechanical cantilever array
Arntz, Y., Seelig, J. D., Lang, H. P., Zhang, J., Hunziker, P., Ramseyer, J. P., Meyer, E., Hegner, M., & Gerber, C. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/1/319 · Cited by 409
Microcantilevers: Sensing Chemical Interactions via Mechanical Motion
Goeders, K. M., Colton, J. S., & Bottomley, L. A. (2008) · Chemical Reviews · doi:10.1021/cr0681041 · Cited by 351
Endo, T., Kerman, K., Nagatani, N., Hiepa, H. M., Kim, D.-K., Yonezawa, Y., Nakano, K., & Tamiya, E. (2006) · Analytical Chemistry · doi:10.1021/ac0608321 · Cited by 349
Gervais, L., & Delamarche, E. (2009) · Lab on a Chip · doi:10.1039/b906523g · Cited by 345
Electrochemical biosensors - principles and applications
Pohanka, M., & Skládal, P. (2008) · Journal of Applied Biomedicine · doi:10.32725/jab.2008.008 · Cited by 341
Bertoncello, P., & Forster, R. J. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.02.013 · Cited by 336
A label-free immunosensor array using single-chain antibody fragments
Backmann, N., Zahnd, C., Huber, F., Bietsch, A., Plückthun, A., Lang, H.-P., Güntherodt, H.-J., Hegner, M., & Gerber, C. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504917102 · Cited by 284
Nanomaterials in fluorescence-based biosensing
Zhong, W. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2643-x · Cited by 269
Electrochemical and chemiluminescent immunosensors for tumor markers
Lin, J., & Ju, H. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.05.008 · Cited by 269
NACB WRITING GROUP MEMBERS, Apple, F. S., Jesse, R. L., Newby, L. K., Wu, A. H. B., Christenson, R. H., NACB COMMITTEE MEMBERS, Christenson, R. H., Apple, F. S., Cannon, C. P., et al. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.084715 · Cited by 258
Cardiac biomarkers and the case for point-of-care testing
McDonnell, B., Hearty, S., Leonard, P., & O'Kennedy, R. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.01.019 · Cited by 254
Electrochemical Impedance Immunosensor Based on Three-Dimensionally Ordered Macroporous Gold Film
Chen, X., Wang, Y., Zhou, J., Yan, W., Li, X., & Zhu, J.-J. (2008) · Analytical Chemistry · doi:10.1021/ac7021376 · Cited by 250
Surface acoustic wave sensors in the bioanalytical field: Recent trends and challenges
Gronewold, T. M. A. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.09.056 · Cited by 250
Protein Detection with Aptamer Biosensors
Strehlitz, B., Nikolaus, N., & Stoltenburg, R. (2008) · Sensors · doi:10.3390/s8074296 · Cited by 237
Su, X.-L., & Li, Y. (2004) · Analytical Chemistry · doi:10.1021/ac049442+ · Cited by 234
Surface enhanced Raman spectroscopy and its application to molecular and cellular analysis
Huh, Y. S., Chung, A. J., & Erickson, D. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0392-3 · Cited by 217
Sung Kim, K., & Park, J.-K. (2005) · Lab on a Chip · doi:10.1039/b502225h · Cited by 217
Mayilo, S., Kloster, M. A., Wunderlich, M., Lutich, A., Klar, T. A., Nichtl, A., Kürzinger, K., Stefani, F. D., & Feldmann, J. (2009) · Nano Letters · doi:10.1021/nl903178n · Cited by 213
Magnetic labeling, detection, and system integration
Tamanaha, C. R., Mulvaney, S. P., Rife, J. C., & Whitman, L. J. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.02.009 · Cited by 205
Wolf, M., Juncker, D., Michel, B., Hunziker, P., & Delamarche, E. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.11.003 · Cited by 193
Cho, I.-H., Paek, E.-H., Kim, Y.-K., Kim, J.-H., & Paek, S.-H. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.11.019 · Cited by 187
Performance of the Spreeta 2000 integrated surface plasmon resonance affinity sensor
Chinowsky, T. M., Quinn, J. G., Bartholomew, D. U., Kaiser, R., & Elkind, J. L. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00113-8 · Cited by 185
Fluoroimmunoassay for Antigen Based on Fluorescence Quenching Signal of Gold Nanoparticles
Ao, L., Gao, F., Pan, B., He, R., & Cui, D. (2006) · Analytical Chemistry · doi:10.1021/ac051323m · Cited by 180
Point-of-care testing of proteins
Warsinke, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2572-0 · Cited by 173
Bioanalytical applications of SERS (surface-enhanced Raman spectroscopy)
Hudson, S. D., & Chumanov, G. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2756-2 · Cited by 170
Faulds, K., Littleford, R. E., Graham, D., Dent, G., & Smith, W. E. (2004) · Analytical Chemistry · doi:10.1021/ac035053o · Cited by 162
Recent developments in potentiometric biosensors for biomedical analysis
Koncki, R. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.08.003 · Cited by 158
Selective Detection of Deoxyribonucleic Acid at Ultralow Concentrations by SERRS
Graham, D., Smith, W. E., Linacre, A. M. T., Munro, C. H., Watson, N. D., & White, P. C. (1997) · Analytical Chemistry · doi:10.1021/ac970657b · Cited by 158
Role and importance of biochemical markers in clinical cardiology
Panteghini, M. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.04.026 · Cited by 153
Cardiac markers and their point-of-care testing for diagnosis of acute myocardial infarction
Yang, Z., & Zhou, D. M. (2006) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2006.05.011 · Cited by 141
Sun, B., Xie, W., Yi, G., Chen, D., Zhou, Y., & Cheng, J. (2001) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00331-8 · Cited by 138
Silane–dextran chemistry on lateral flow polymer chips for immunoassays
Jönsson, C., Aronsson, M., Rundström, G., Pettersson, C., Mendel-Hartvig, I., Bakker, J. W. P., Martinsson, E., Liedberg, B., MacCraith, B. D., Öhman, O., et al. (2008) · Lab on a Chip · doi:10.1039/b800297e · Cited by 132
Feltis, B., Sexton, B. A., Glenn, F. L., Best, M., Wilkins, M., & Davis, T. J. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.11.005 · Cited by 131
Lee, J. H., Yoon, K. H., Hwang, K. S., et al. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.01.024 · Cited by 131
Faulds, K., Barbagallo, R. P., Keer, J. T., Smith, W. E., & Graham, D. (2004) · The Analyst · doi:10.1039/b406423b · Cited by 130
A potentiometric protein sensor built with surface molecular imprinting method
Wang, Y., Zhou, Y., Sokolov, J., Rigas, B., Levón, K., & Rafailovich, M. H. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.04.010 · Cited by 129
A new protein A assay based on Raman reporter labeled immunogold nanoparticles
Lin, J. F., Yang, Y.-M., Chen, Y., Yang, T.-S., & Chang, H.-C. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.03.035 · Cited by 119
Lanthanide Complexes and Quantum Dots: A Bright Wedding for Resonance Energy Transfer
Charbonnière, L. J., & Hildebrandt, N. (2008) · European Journal of Inorganic Chemistry · doi:10.1002/ejic.200800332 · Cited by 116
Electrochemical biosensors for food analysis
Viswanathan, S., Radecka, H., & Radecki, J. (2009) · Monatshefte für Chemie - Chemical Monthly · doi:10.1007/s00706-009-0143-5 · Cited by 115
Aptamer–antibody on-chip sandwich immunoassay for detection of CRP in spiked serum
Pultar, J., Sauer, U., Domnanich, P., & Preininger, C. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.08.052 · Cited by 114
Luminescent quantum dots in immunoassays
Goldman, E. R., Medintz, I. L., & Mattoussi, H. M. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0212-5 · Cited by 113
Bhattacharyya, A., & Klapperich, C. M. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-9026-2 · Cited by 111
Multiple-Analyte Fluoroimmunoassay Using an Integrated Optical Waveguide Sensor
Plowman, T. E., Durstchi, J. D., Wang, H. K., Christensen, D. A., Herron, J. N., & Reichert, W. M. (1999) · Analytical Chemistry · doi:10.1021/ac990183b · Cited by 107
Han, X. X., Cai, L., Guo, J., Wang, C. X., Ruan, W., Han, W. Y., Xu, W. Q., Zhao, B., & Ozaki, Y. (2008) · Analytical Chemistry · doi:10.1021/ac702497t · Cited by 91
Metal particle-enhanced fluorescent immunoassays on metal mirrors
Matveeva, E. G., Gryczyński, I., Barnett, A., Leonenko, Z., Lakowicz, J. R., & Gryczynski, Z. K. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.030 · Cited by 86
Kurosawa, S., Nakamura, M., Park, J.-W., Aizawa, H., Yamada, K., & Hirata, M. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.05.016 · Cited by 83
Compact, high performance surface plasmon resonance imaging system
Chinowsky, T. M., Grow, M. S., Johnston, K. S., Nelson, K. E., Edwards, T. L., Fu, E. S., & Yager, P. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.10.030 · Cited by 73
Fabrication of Anti-human Cardiac Troponin I Immunogold Nanorods for Sensing Acute Myocardial Damage
Zr, G., Gu, C., Fan, X., Bian, Z., Wu, H., Yang, D., Gu, N., & Zhang, J. N. (2009) · Nanoscale Research Letters · doi:10.1007/s11671-009-9415-6 · Cited by 69
Christenson, R. H., & Azzazy, H. M. E.-S. (2008) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2008.09.105 · Cited by 65
Kamahori, M., Ishige, Y., & Shimoda, M. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.01.011 · Cited by 60
Quantitative SERRS immunoassay for the detection of human PSA
Stevenson, R., Ingram, A., Leung, H. Y., McMillan, D. C., & Graham, D. (2009) · The Analyst · doi:10.1039/b902174d · Cited by 51
Achieving high-purity colloidal gold nanoprisms and their application as biosensing platforms
Guo, Z., Fan, X., Liu, L., Bian, Z., Gu, C., Zhang, Y., Gu, N., Yang, D., & Zhang, J. (2010) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2010.04.013 · Cited by 48
Quantum Dots as Reporters in Multiplexed Immunoassays for Biomarkers of Exposure to Agrochemicals
Nichkova, M. I., Dosev, D., Davies, A. E., Gee, S. J., Kennedy, I. M., & Hammock, B. D. (2007) · Analytical Letters · doi:10.1080/00032710701327088 · Cited by 42
Autonomous capillary system for one-step immunoassays
Zimmermann, M., Hunziker, P., & Delamarche, E. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9187-2 · Cited by 42
SERRS immunoassay for quantitative human CRP analysis
Campbell, F., Ingram, A., Monaghan, P., Cooper, J. M., Sattar, N. A., Eckersall, P. D., & Graham, D. (2008) · The Analyst · doi:10.1039/b808087a · Cited by 36
Wei, H., Zhou, L., Li, J., Liu, J., & Wang, E. (2008) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2008.02.012 · Cited by 36
Modification of ISFETs with a monolayer of latex beads for specific detection of proteins
Besselink, G. A. J., Schasfoort, R. B. M., & Bergveld, P. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00243-9 · Cited by 33
Gül, Ö., Calay, E. S., Sezerman, O. U., Başağa, H., & Gürbüz, Y. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.03.005 · Cited by 32
Magnetic Immunoassays Utilizing Magnetic Markers and a High- $T_rm c$ SQUID
Enpuku, K., Inoue, K., Soejima, K., Yoshinaga, K., Kuma, H., & Hamasaki, N. (2005) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2005.849991 · Cited by 31
Proteomic approach to the diagnosis of acute coronary syndrome: Preliminary results
Serio, F. D., Amodio, G., Ruggieri, E., Sario, R. D., Varraso, L., Antonelli, G., & Pansini, N. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.03.031 · Cited by 28
Yun, K., Lee, D., Kim, H., et al. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/12/s10 · Cited by 27
Cardiac marker point-of-care testing in the Emergency Department and Cardiac Care Unit
Brogan, G. X., & Bock, J. L. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.8.1865 · Cited by 27
New cut-off values of cardiac markers for risk stratification of angina pectoris
Jordanova, N., Gyöngyösi, M., Khorsand, A., Falkensammer, C. B., Zorn, G., Wojta, J., Anvari, A., & Huber, K. (2004) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.03.003 · Cited by 21
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Nanomaterial-based Electrochemical Biosensors
Şensoy, K. G., Akpınar, F., & Muti, M. (2024) · Current Nanoscience · doi:10.2174/1573413718666220819143711 · Cited by 701
Paper-based nanobiosensors for diagnostics
Parolo, C., & Merkoçi, A. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35255a · Cited by 550
Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies
Jung, W., Han, J., Choi, J.-W., & Ahn, C. H. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.09.024 · Cited by 510
Biosensors for cardiac biomarkers detection: A review
Qureshi, A., Gurbuz, Y., & Niazi, J. H. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.05.077 · Cited by 409
Metadata
- Authors
- Mohammed, M.-I., & Desmulliez, M. P. Y.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 4
- Pages
- 569-595
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2106330541
- Cited by
- 304
- References
- 84
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.