The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Energy transfer cassettes based on organic fluorophores: construction and applications in ratiometric sensing
Abstract
This tutorial review presents some recent developments in the construction and applications of cassettes based on resonance energy transfer between fluorescent dyes in the visible and infrared region. We focused on the contributions of different connections between the energy donor and acceptor according to the "through-space" and "through-bond" methods, and emphasised their applications in ratiometric sensing for the detection of ions and small molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy transfer: a spectroscopic ruler.
Stryer, L., & Haugland, R. P. (1967) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.58.2.719 · Cited by 1,957
Bright Ideas for Chemical Biology
Lavis, L. D., & Raines, R. T. (2008) · ACS Chemical Biology · doi:10.1021/cb700248m · Cited by 1,290
Fluorescence resonance energy transfer (FRET) microscopy imaging of live cell protein localizations
Sekar, R. B., & Periasamy, A. (2003) · The Journal of Cell Biology · doi:10.1083/jcb.200210140 · Cited by 932
A Ratiometric Fluorescent Probe Based on FRET for Imaging Hg 2+ Ions in Living Cells
Zhang, X., Xiao, Y., & Qian, X. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803246 · Cited by 800
Oevering, H., Paddon‐Row, M. N., Heppener, M., et al. (1987) · Journal of the American Chemical Society · doi:10.1021/ja00245a014 · Cited by 542
Oh, E., Hong, M.-Y., Lee, D., Nam, S.-H., Yoon, H. C., & Kim, H.-S. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0433323 · Cited by 512
Speiser, S. (1996) · Chemical Reviews · doi:10.1021/cr941193+ · Cited by 418
Coskun, A., & Akkaya, E. U. (2006) · Journal of the American Chemical Society · doi:10.1021/ja066144g · Cited by 391
Yuan, L., Lin, W., Xie, Y., Chen, B., & Zhu, S. (2012) · Journal of the American Chemical Society · doi:10.1021/ja2100577 · Cited by 387
A FRET-Based Approach to Ratiometric Fluorescence Detection of Hydrogen Peroxide
Albers, A. E., Okreglak, V. S., & Chang, C. J. (2006) · Journal of the American Chemical Society · doi:10.1021/ja063308k · Cited by 375
Synthesis and Application of Quantum Dots FRET-Based Protease Sensors
Shi, L., De Paoli, V., Rosenzweig, N., & Rosenzweig, Z. (2006) · Journal of the American Chemical Society · doi:10.1021/ja063509o · Cited by 352
dos Remedios, C. G., & Moens, P. D. J. (1995) · Journal of Structural Biology · doi:10.1006/jsbi.1995.1042 · Cited by 347
Ratiometric Detection of Cr3+and Hg2+by a Naphthalimide-Rhodamine Based Fluorescent Probe
Mahato, P., Saha, S., Suresh, E., Di Liddo, R., Parnigotto, P. P., Conconi, M. T., Kesharwani, M. K., Ganguly, B., & Das, A. (2012) · Inorganic Chemistry · doi:10.1021/ic202073q · Cited by 319
Anthracene–BODIPY Cassettes: Syntheses and Energy Transfer
Wan, C., Burghart, A., Chen, J., Bergström, F., Johansson, L. B. ‐., Wolford, M. F., Kim, T. G., Topp, M. R., Hochstrasser, R. M., & Burgess, K. (2003) · Chemistry – A European Journal · doi:10.1002/chem.200304754 · Cited by 274
Shao, J., Sun, H., Guo, H., Ji, S., Zhao, J., Wu, W., Yuan, X., Zhang, C., & James, T. D. (2012) · Chem. Sci. · doi:10.1039/c2sc00762b · Cited by 265
Fluorescein Provides a Resonance Gate for FRET from Conjugated Polymers to DNA Intercalated Dyes
Wang, S., Gaylord, B. S., & Bazan, G. C. (2004) · Journal of the American Chemical Society · doi:10.1021/ja035550m · Cited by 260
Han, Z.-X., Zhang, X.-B., Li, Z., Gong, Y.-J., Wu, X.-Y., Jin, Z., He, C.-M., Jian, L.-X., Zhang, J., Shen, G.-L., et al. (2010) · Analytical Chemistry · doi:10.1021/ac100376a · Cited by 245
Kurishita, Y., Kohira, T., Ojida, A., & Hamachi, I. (2010) · Journal of the American Chemical Society · doi:10.1021/ja103615z · Cited by 239
Construction of a FRET-based ratiometric fluorescent thiol probe
Long, L., Lin, W., Chen, B., Gao, W., & Yuan, L. (2011) · Chem. Commun. · doi:10.1039/c0cc03806g · Cited by 222
Ratiometric Molecular Sensor for Monitoring Oxygen Levels in Living Cells
Yoshihara, T., Yamaguchi, Y., Hosaka, M., Takeuchi, T., & Tobita, S. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201107557 · Cited by 222
Szöllosi, J., Damjanovich, S., & Mátyus, L. (1998) · Cytometry · doi:10.1002/(sici)1097-0320(19980815)34:4<159::aid-cyto1>3.3.co;2-9 · Cited by 214
Yuan, L., Lin, W., Chen, B., & Xie, Y. (2012) · Organic Letters · doi:10.1021/ol202706k · Cited by 199
Qu, X., Liu, Q., Ji, X., Chen, H., Zhou, Z., & Shen, Z. (2012) · Chemical Communications · doi:10.1039/c2cc31011b · Cited by 196
Jiao, G.-S., Thoresen, L. H., & Burgess, K. (2003) · Journal of the American Chemical Society · doi:10.1021/ja037193l · Cited by 190
Lin, W., Yuan, L., Cao, Z., Feng, Y., & Song, J. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200904515 · Cited by 189
Yilmaz, M. D., Bozdemir, O. A., & Akkaya, E. U. (2006) · Organic Letters · doi:10.1021/ol061110z · Cited by 181
Yuan, L., Lin, W., Xie, Y., Chen, B., & Song, J. (2012) · Chemistry – A European Journal · doi:10.1002/chem.201101918 · Cited by 181
Takakusa, H., Kikuchi, K., Urano, Y., Sakamoto, S., Yamaguchi, K., & Nagano, T. (2002) · Journal of the American Chemical Society · doi:10.1021/ja011251q · Cited by 170
Highly Efficient Energy Transfer in Subphthalocyanine−BODIPY Conjugates
Liu, J.-Y., Yeung, H.-S., Xu, W., Li, X., & Ng, D. K. P. (2008) · Organic Letters · doi:10.1021/ol8023677 · Cited by 166
Zhang, X., Xiao, Y., & Qian, X. H. (2007) · Organic Letters · doi:10.1021/ol702381j · Cited by 158
FRET spectral unmixing: a ratiometric fluorescent nanoprobe for hypochlorite
Chen, G., Song, F., Wang, J., Yang, Z., Sun, S., Fan, J., Qiang, X., Wang, X., Dou, B., & Peng, X. (2011) · Chemical Communications · doi:10.1039/c2cc17617c · Cited by 152
Self-citationA FRET-Based Ultraviolet to Near-Infrared Frequency Converter
Serin, J. M., Brousmiche, D. W., & Fréchet, J. M. J. (2002) · Journal of the American Chemical Society · doi:10.1021/ja027564i · Cited by 148
Functionalized BF2 chelated azadipyrromethene dyes
Loudet, A., Bandichhor, R., Wu, L., & Burgess, K. (2008) · Tetrahedron · doi:10.1016/j.tet.2008.01.117 · Cited by 126
Water-Soluble Through-Bond Energy Transfer Cassettes for Intracellular Imaging
Bandichhor, R., Petrescu, A. D., Vespa, A., Kier, A. B., Schroeder, F., & Burgess, K. (2006) · Journal of the American Chemical Society · doi:10.1021/ja063784a · Cited by 119
Cao, X., Lin, W., & Yu, Q. (2011) · The Journal of Organic Chemistry · doi:10.1021/jo201199k · Cited by 117
Encapsulated Energy-Transfer Cassettes with Extremely Well Resolved Fluorescent Outputs
Ueno, Y., Jose, J., Loudet, A., Pérez‐Bolívar, C., Anzenbacher, P., & Burgess, K. (2010) · Journal of the American Chemical Society · doi:10.1021/ja107193j · Cited by 112
Batat, P., Cantuel, M., Jonušauskas, G., Scarpantonio, L., Palma, A., O’Shea, D. F., & McClenaghan, N. D. (2011) · The Journal of Physical Chemistry A · doi:10.1021/jp2077775 · Cited by 105
El‐Khouly, M. E., Amin, A. N., Zandler, M. E., Fukuzumi, S., & D'Souza, F. W. (2012) · Chemistry - A European Journal · doi:10.1002/chem.201103074 · Cited by 104
Zhao, Y. F., Zhang, Y., Lv, X., Liu, Y., Chen, M., Wang, P., Liu, J., & Guo, W. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm12503f · Cited by 72
Boradiazaindacene (Bodipy)-based building blocks for the construction of energy transfer cassettes
Barın, G., Yilmaz, M. D., & Akkaya, E. U. (2009) · Tetrahedron Letters · doi:10.1016/j.tetlet.2009.01.141 · Cited by 63
Jiao, G., Thoresen, L. H., Kim, T. G., Haaland, W. C., Gao, F., Topp, M. R., Hochstrasser, R. M., Metzker, M. L., & Burgess, K. (2006) · Chemistry - A European Journal · doi:10.1002/chem.200600197 · Cited by 52
Hu, X., Zhang, X., He, G., He, C., & Duan, C. (2010) · Tetrahedron · doi:10.1016/j.tet.2010.12.026 · Cited by 37
Cited by
Small molecule-based ratiometric fluorescence probes for cations, anions, and biomolecules
Lee, M. H., Kim, J. S., & Sessler, J. L. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00280f · Cited by 1,642
Triplet photosensitizers: from molecular design to applications
Zhao, J., Wu, W., Sun, J., & Guo, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35531d · Cited by 1,579
Structural modification strategies for the rational design of red/NIR region BODIPYs
Lu, H., Mack, J., Yang, Y., & Shen, Z. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00030g · Cited by 1,326
Recent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
Self-citationFörster resonance energy transfer (FRET)-based small-molecule sensors and imaging agents
Wu, L., Huang, C., Emery, B. P., Sedgwick, A. C., Bull, S. D., He, X.-P., Tian, H., Yoon, J., Sessler, J. L., & James, T. D. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00318e · Cited by 1,026
Metadata
- Authors
- Fan, J., Hu, M., Zhan, P., & Peng, X.
- Venue
- Chem. Soc. Rev.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 42
- Issue
- 1
- Pages
- 29-43
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2152173477
- Cited by
- 821
- References
- 42
- FWCI
- 2.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.