The DOI matches its Crossref record; 219 of the 219 references it cites were found in a registry or an index.
Assessment, origin, and implementation of breath volatile cancer markers
Open accessAbstract
A new non-invasive and potentially inexpensive frontier in the diagnosis of cancer relies on the detection of volatile organic compounds (VOCs) in exhaled breath samples. Breath can be sampled and analyzed in real-time, leading to fascinating and cost-effective clinical diagnostic procedures. Nevertheless, breath analysis is a very young field of research and faces challenges, mainly because the biochemical mechanisms behind the cancer-related VOCs are largely unknown. In this review, we present a list of 115 validated cancer-related VOCs published in the literature during the past decade, and classify them with respect to their "fat-to-blood" and "blood-to-air" partition coefficients. These partition coefficients provide an estimation of the relative concentrations of VOCs in alveolar breath, in blood and in the fat compartments of the human body. Additionally, we try to clarify controversial issues concerning possible experimental malpractice in the field, and propose ways to translate the basic science results as well as the mechanistic understanding to tools (sensors) that could serve as point-of-care diagnostics of cancer. We end this review with a conclusion and a future perspective.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Genomic signatures to guide the use of chemotherapeutics
Potti, A., Dressman, H. K., Bild, A., Riedel, R. F., Chan, G., Sayer, R., Cragun, J., Cottrill, H., Kelley, M. J., Petersen, R., et al. (2006) · Nature Medicine · doi:10.1038/nm1491 · Cited by 593
RetractedSinger, S. J., & Nicolson, G. L. (1972) · Science · doi:10.1126/science.175.4023.720 · Cited by 9,154
Why Do Cancers Have High Aerobic Glycolysis?
Gatenby, R. A., & Gillies, R. J. (2004) · Nature reviews. Cancer · doi:10.1038/nrc1478 · Cited by 4,784
Herbst, R. S., Heymach, J. V., & Lippman, S. M. (2008) · New England Journal of Medicine · doi:10.1056/nejmra0802714 · Cited by 2,389
Free radicals, antioxidants, and human disease: where are we now?
Halliwell, B. B., Gutteridge, J. M. C., & Cross, C. E. (1992) · PubMed · Cited by 2,163
Weinberg, R. A., & Weinberg, R. A. (2006) · W.W. Norton eBooks · doi:10.1201/9780203852569 · Cited by 1,751
DNA Repair by ERCC1 in Non–Small-Cell Lung Cancer and Cisplatin-Based Adjuvant Chemotherapy
Olaussen, K. A., Dunant, A., Fouret, P., Brambilla, E., André, F., Haddad, V., Taranchon, E., Filipits, M., Pirker, R., Popper, H. H., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa060570 · Cited by 1,727
Detection of Mutations in EGFR in Circulating Lung-Cancer Cells
Maheswaran, S., Sequist, L. V., Nagrath, S., Ulkus, L., Brannigan, B., Collura, C. V., Inserra, E., Diederichs, S., Iafrate, A. J., Bell, D. W., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800668 · Cited by 1,617
Electronic Nose: Current Status and Future Trends
Röck, F., Barsan, N., & Weimar, U. (2008) · Chemical Reviews · doi:10.1021/cr068121q · Cited by 1,437
Arnstein, H. R. V. (1986) · FEBS Letters · doi:10.1016/0014-5793(86)80238-1 · Cited by 1,387
Cited by
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Self-citationRecent Progress on the Development of Chemosensors for Gases
Zhou, X., Lee, S., Xu, Z., & Yoon, J. (2015) · Chemical Reviews · doi:10.1021/cr500567r · Cited by 777
A European Respiratory Society technical standard: exhaled biomarkers in lung disease
Horváth, I., Barnes, P. J., Loukides, S., Sterk, P. J., Högman, M., Olin, A.-C., Amann, A., Antus, B., Baraldi, E., Bikov, A., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00965-2016 · Cited by 638
Self-citationSensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Self-citationNakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b04930 · Cited by 510
Self-citationBreath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487
Self-citationBroza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Self-citationElectronic Noses: From Advanced Materials to Sensors Aided with Data Processing
Hu, W., Wan, L., Jian, Y., Ren, C., Jin, K., Su, X., Bai, X., Haick, H., Yao, M., & Wu, W. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800488 · Cited by 366
Self-citationSolid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
Wearable and Miniaturized Sensor Technologies for Personalized and Preventive Medicine
Tricoli, A., Nasiri, N., & De, S. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605271 · Cited by 346
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
Self-citationProspects and Challenges of Volatile Organic Compound Sensors in Human Healthcare
Jalal, A. H., Alam, F., Roychoudhury, S., Umasankar, Y., Pala, N., & Bhansali, S. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00400 · Cited by 315
Advanced Materials for Health Monitoring with Skin‐Based Wearable Devices
Jin, H., Abu‐Raya, Y. S., & Haick, H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700024 · Cited by 317
Self-citationBreath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Chen, Y., Zhang, Y., Pan, F., Liu, J., Wang, K., Zhang, C., Cheng, S., Lu, L., Zhang, W., Zhang, Z., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b01441 · Cited by 298
Hybrid Volatolomics and Disease Detection
Broza, Y. Y., Mochalski, P., Ruzsanyi, V., Amann, A., & Haick, H. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201500153 · Cited by 290
Self-citationSynergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation
Broza, Y. Y., Vishinkin, R., Barash, O., Nakhleh, M. K., & Haick, H. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00317c · Cited by 276
Self-citationShehada, N., Brönstrup, G., Funka, K., Christiansen, S., Leja, M., & Haick, H. (2015) · Nano Letters · doi:10.1021/nl504482t · Cited by 255
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236
Silicon Nanowire Sensors Enable Diagnosis of Patients via Exhaled Breath
Shehada, N., Cancilla, J. C., Torrecilla, J. S., Pariente, E. S., Brönstrup, G., Christiansen, S., Johnson, D. W., Leja, M., Davies, M. P. A., Liran, O., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b03127 · Cited by 227
Self-citationFlexible MXene/rGO/CuO hybrid aerogels for high performance acetone sensing at room temperature
Liu, M., Wang, Z., Song, P., Yang, Z., & Wang, Q. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129946 · Cited by 222
Maity, A., Raychaudhuri, A. K., & Ghosh, B. (2019) · Scientific Reports · doi:10.1038/s41598-019-43961-6 · Cited by 200
Jin, H., Huynh, T.-P., & Haick, H. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01066 · Cited by 167
Self-citationBreath VOC analysis and machine learning approaches for disease screening: a review
P, H., Rangarajan, M., & Pandya, H. J. (2023) · Journal of Breath Research · doi:10.1088/1752-7163/acb283 · Cited by 37
Metadata
- Authors
- Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A.
- Venue
- Chem. Soc. Rev.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 43
- Issue
- 5
- Pages
- 1423-1449
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2106055476
- Cited by
- 644
- References
- 219
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.