The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Micromilling: a method for ultra-rapid prototyping of plastic microfluidic devices
Open accessAbstract
Micromilling is a fast and simple method capable of fabricating complex 2D or 3D microdevices compatible with cell culture and microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RESISTANCE OF SOLID SURFACES TO WETTING BY WATER
Wenzel, R. N. (1936) · Industrial & Engineering Chemistry · doi:10.1021/ie50320a024 · Cited by 13,316
Femtosecond laser micromachining in transparent materials
Gattass, R. R., & Mazur, E. (2008) · Nature Photonics · doi:10.1038/nphoton.2008.47 · Cited by 3,247
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Self-citationA review on stereolithography and its applications in biomedical engineering
Melchels, F. P. W., Feijen, J., & Grijpma, D. W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.050 · Cited by 2,457
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,187
Commercialization of microfluidic point-of-care diagnostic devices
Chin, C. D., Linder, V., & Sia, S. K. (2012) · Lab on a Chip · doi:10.1039/c2lc21204h · Cited by 1,124
Deligianni, D. D., Katsala, N. D., Koutsoukos, P. G., & Missirlis, Y. F. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00174-5 · Cited by 1,111
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
The interaction of cells and bacteria with surfaces structured at the nanometre scale
Anselme, K., Davidson, P., Popa, A. M., Giazzon, M., Liley, M., & Ploux, L. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.04.001 · Cited by 827
Gittens, R. A., McLachlan, T., Olivares-Navarrete, R., Cai, Y., Berner, S., Tannenbaum, R., Schwartz, Z., Sandhage, K. H., & Boyan, B. D. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.029 · Cited by 827
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Self-citationPolymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795
Hot embossing as a method for the fabrication of polymer high aspect ratio structures
Becker, H., & Heim, U. (2000) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(00)00296-x · Cited by 666
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Self-citationMetal Machining: Theory and Applications
Childs, T. H. C., Maekawa, K., OBIKAWA, T., & Yamane, Y. (2000) · Cited by 571
Kieswetter, K., Schwartz, Z., Hummert, T. W., Cochran, D. L., Simpson, J., Dean, D. D., & Boyan, B. D. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199609)32:1<55::aid-jbm7>3.0.co;2-o · Cited by 565
Anselme, K., Bigerelle, M., Noel, B., Dufresne, E., Judas, D., Iost, A., & Hardouin, P. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(200002)49:2<155::aid-jbm2>3.0.co;2-j · Cited by 507
Klank, H., Kutter, J. P., & Geschke, O. (2002) · Lab on a Chip · doi:10.1039/b206409j · Cited by 477
Micro-injection moulding of polymer microfluidic devices
Attia, U. M., Marson, S., & Alcock, J. R. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0421-x · Cited by 474
Waldbaur, A., Rapp, H., Länge, K., & Rapp, B. E. (2011) · Analytical Methods · doi:10.1039/c1ay05253e · Cited by 381
Mail-order microfluidics: evaluation of stereolithography for the production of microfluidic devices
Au, A. K., Lee, W., & Folch, A. (2014) · Lab Chip · doi:10.1039/c3lc51360b · Cited by 380
Dowling, D. P., Miller, I. S., Ardhaoui, M., & Gallagher, W. M. (2011) · Journal of Biomaterials Applications · doi:10.1177/0885328210372148 · Cited by 376
Mukhopadhyay, R. (2007) · Analytical Chemistry · doi:10.1021/ac071903e · Cited by 355
Discrete elements for 3D microfluidics
Bhargava, K. C., Thompson, B., & Malmstadt, N. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1414764111 · Cited by 298
Xu, C., Yang, F., Wang, S., & Ramakrishna, S. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30143 · Cited by 267
Hard AlTiN, AlCrN PVD coatings for machining of austenitic stainless steel
Endrino, J. L., Fox-Rabinovich, G. S., & Gey, C. (2006) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2005.10.030 · Cited by 262
核内受容体NR2F2は,マウスMA-10とMLTC-1ライディヒ細胞におけるStar発現とステロイド産生を活性化する
Raifish, E. M.-V., Nicholas, M. R., Luc, J. M., et al. (2014) · Biology of Reproduction · Cited by 243
Micro-burr formation and minimization through process control
Lee, K., & Dornfeld, D. A. (2004) · Precision Engineering · doi:10.1016/j.precisioneng.2004.09.002 · Cited by 218
Hatano, K., Inoue, H., Kojo, T., Matsunaga, T., Tsujisawa, T., Uchiyama, C., & Uchida, Y. (1999) · Bone · doi:10.1016/s8756-3282(99)00192-1 · Cited by 216
Rapid prototyping of microfluidic chips in COC
Steigert, J., Haeberle, S., Brenner, T., Müller, C., Steinert, C. P., Koltay, P., Gottschlich, N., Reinecke, H., Rühe, J., Zengerle, R., et al. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/2/020 · Cited by 194
Reduction of surface roughness for optical quality microfluidic devices in PMMA and COC
Ogilvie, I. R. G., Sieben, V. J., Floquet, C. F. A., Zmijan, R., Mowlem, M. C., & Morgan, H. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/6/065016 · Cited by 185
Rapid Prototyping of Arrayed Microfluidic Systems in Polystyrene for Cell-Based Assays
Young, E. W. K., Berthier, E., Guckenberger, D. J., Sackmann, E., Lamers, C., Meyvantsson, I., Huttenlocher, A., & Beebe, D. J. (2011) · Analytical Chemistry · doi:10.1021/ac102897h · Cited by 172
Self-citationWilson, M. E., Kota, N., Kim, Y., Wang, Y., Stolz, D. B., LeDuc, P. R., & Ozdoganlar, O. B. (2011) · Lab on a Chip · doi:10.1039/c0lc00561d · Cited by 158
Shrinky-Dink microfluidics: 3D polystyrene chips
Chen, C., Breslauer, D. N., Luna, J. I., Grimes, A., Chin, W., Lee, L. P., & Khine, M. (2008) · Lab on a Chip · doi:10.1039/b719029h · Cited by 152
New materials for microfluidics in biology
Ren, K., Chen, Y., & Wu, H. (2013) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.09.004 · Cited by 142
5-axis micro milling machine for machining micro parts
Bang, Y., Lee, K.-M., & Oh, S. H. (2004) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-003-1950-1 · Cited by 130
Three‐dimensional femtosecond laser micromachining of photosensitive glass for biomicrochips
Sugioka, K., Hanada, Y., & Midorikawa, K. (2009) · Laser & Photonics Review · doi:10.1002/lpor.200810074 · Cited by 106
Mustafa, K. B. E., Odén, A., Wennerberg, A., Hultenby, K. R., & Arvidson, K. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.037 · Cited by 105
Lamíkiz, A., de Lacalle, L. N. L., Ocerin, O., Díez, D., & Maidagan, E. (2007) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-007-0956-5 · Cited by 101
Three-dimensional axisymmetric flow-focusing device using stereolithography
Morimoto, Y., Tan, W.-H., & Takeuchi, S. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9243-y · Cited by 85
Bischel, L. L., Mader, B. R., Green, J. M., Anna Huttenlocher, A., & Beebe, D. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50099c · Cited by 63
Self-citationThe VerIFAST: an integrated method for cell isolation and extracellular/intracellular staining
Casavant, B. P., Guckenberger, D. J., Berry, S. M., et al. (2012) · Lab on a Chip · doi:10.1039/c2lc41136a · Cited by 62
Self-citationChip Morphology and Forces in End Milling of Elastomers
Shih, A. J., Luo, J., Lewis, M. A., & Strenkowski, J. S. (2004) · Journal of Manufacturing Science and Engineering · doi:10.1115/1.1633276 · Cited by 51
Young, E. W. K., Berthier, E., & Beebe, D. J. (2012) · Analytical Chemistry · doi:10.1021/ac3034773 · Cited by 49
Self-citationContact Angle Hysteresis on Polymer Surfaces: An Experimental Study
Ruiz‐Cabello, F. J. M., Rodríguez-Valverde, M. A., & Cabrerizo-Vílchez, M. Á. (2011) · Journal of Adhesion Science and Technology · doi:10.1163/016942410x544848 · Cited by 41
The development of an in-process surface roughness adaptive control system in end milling operations
Zhang, J. Z., & Chen, J. C. (2006) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-005-0262-z · Cited by 35
Kit-On-A-Lid-Assays for accessible self-contained cell assays
Berthier, E., Guckenberger, D. J., Cavnar, P. J., Anna Huttenlocher, A., Keller, N. P., & Beebe, D. J. (2012) · Lab on a Chip · doi:10.1039/c2lc41019b · Cited by 26
Self-citationCarney, C. M., Muszynski, J. L., Strotman, L. N., Lewis, S. R., O'Connell, R. L., Beebe, D. J., Theberge, A. B., & Jorgensen, J. S. (2014) · Biology of Reproduction · doi:10.1095/biolreprod.114.118570 · Cited by 25
Self-citationIon channel recordings on an injection-molded polymer chip
Tanzi, S., Matteucci, M., Christiansen, T. L., Friis, S., Christensen, M. T., Garnaes, J., Wilson, S., Kutchinsky, J., & Taboryski, R. (2013) · Lab on a Chip · doi:10.1039/c3lc50760b · Cited by 14
High-Density Self-Contained Microfluidic KOALA Kits for Use by Everyone
Guckenberger, D. J., Berthier, E., & Beebe, D. J. (2014) · SLAS TECHNOLOGY · doi:10.1177/2211068214560609 · Cited by 12
Self-citation
Cited by
Fabrication and Applications of Microfluidic Devices: A Review
Niculescu, A.-G., Chircov, C., Bîrcă, A. C., & Grumezescu, A. M. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22042011 · Cited by 678
Point-of-Care Diagnostics: Recent Developments in a Connected Age
Nayak, S., Blumenfeld, N. R., Laksanasopin, T., & Sia, S. K. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04630 · Cited by 508
Tsao, C.-W. (2016) · Micromachines · doi:10.3390/mi7120225 · Cited by 367
Recent Advances in Analytical Chemistry by 3D Printing
Gross, B., Lockwood, S. Y., & Spence, D. M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04344 · Cited by 359
Moragues, T., Arguijo, D., Beneyton, T., Modavi, C., Simutis, K., Abate, A. R., Baret, J.-C., deMello, A. J., Densmore, D., & Griffiths, A. D. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00212-3 · Cited by 316
Metadata
- Authors
- Guckenberger, D. J., de Groot, T. E., Wan, A. M. D., Beebe, D. J., & Young, E. W. K.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 15
- Issue
- 11
- Pages
- 2364-2378
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2071571360
- Cited by
- 513
- References
- 50
- FWCI
- 19.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.