CoChat

Variability of photoplethysmographyperipheral pulse measurementsat the ears, thumbs and toes

Allen, J., Murray, A. · 2000 · IEE Proceedings - Science, Measurement and Technology
Cited by 76

The DOI matches its Crossref record.

Abstract

Pulses radiating to the periphery after each heart beat can be detected by photoplethysmography (PPG). A multi-site PPG measurement and analysis system is described for beat-to-beat analysis of the pulse waveforms. Waveforms were collected from the right and left ear lobes, thumb pads, and toe pads of 20 normal subjects whilst they performed paced breathing. The median coefficients of variation for pulse amplitude were; ears and thumbs 11%, and toes 14%. Significant differences in pulse transit time of 4 ms (to foot of pulse), and 14 ms (to peak of pulse) between the right and left toes were detected (right lagging left, p < 0.01). The median pulse transit times (to foot) were; ears (0.133 s), thumbs (0.199 s), and toes (0.301 s), with coefficients of variation; 2.8%, 2.2%, and 1.6%, respectively. The median pulse transit times (to peak) were; ears (0.397 s), thumbs (0.436 s), and toes (0.515 s), with coefficients of variation; 1.4%, 2.0%, and 1.5%, respectively. The authors have utilised signal processing algorithms to calculate beat-to-beat measures of pulsatility, and determined normative data for multi-site PPG pulse assessments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1049/ip-smt:20000846

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Allen, J., & Murray, A.
Venue
IEE Proceedings - Science, Measurement and Technology
Published
2000-11-03
Volume
147
Issue
6
Pages
403-407
ISSN
  • 1350-2344 (ISSN-L)
  • 1359-7094
OpenAlex
W1985278913
Cited by
76
References
0
FWCI
1.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.