Variability of photoplethysmographyperipheral pulse measurementsat the ears, thumbs and toes
The DOI matches its Crossref record.
Abstract
Pulses radiating to the periphery after each heart beat can be detected by photoplethysmography (PPG). A multi-site PPG measurement and analysis system is described for beat-to-beat analysis of the pulse waveforms. Waveforms were collected from the right and left ear lobes, thumb pads, and toe pads of 20 normal subjects whilst they performed paced breathing. The median coefficients of variation for pulse amplitude were; ears and thumbs 11%, and toes 14%. Significant differences in pulse transit time of 4 ms (to foot of pulse), and 14 ms (to peak of pulse) between the right and left toes were detected (right lagging left, p < 0.01). The median pulse transit times (to foot) were; ears (0.133 s), thumbs (0.199 s), and toes (0.301 s), with coefficients of variation; 2.8%, 2.2%, and 1.6%, respectively. The median pulse transit times (to peak) were; ears (0.397 s), thumbs (0.436 s), and toes (0.515 s), with coefficients of variation; 1.4%, 2.0%, and 1.5%, respectively. The authors have utilised signal processing algorithms to calculate beat-to-beat measures of pulsatility, and determined normative data for multi-site PPG pulse assessments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“These characteristics are also body site dependent (Allen and Murray 2000b).”
BackgroundInfluentialSelf-citationToward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“7) at rest typically ranges from 180 to 260 ms (finger) [98], [147], [148], [152], [153], 125 to 155 ms (ear) [152], [153], and 180 to 330 ms (toe) [144], [152], [153].”
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9505-0 · Cited by 203
Allen, J., & Murray, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/306 · Cited by 202
Self-citationAge-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179
Self-citationHartmann, V., Liu, H., Chen, F., Qiu, Q., Hughes, S., & Zheng, D. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00198 · Cited by 173
The effect of contacting force on photoplethysmographic signals
Teng, X. F., & Zhang, Y. T. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/020 · Cited by 171
“These results are consistent with a previous report that the coefficient of variability of pulse amplitude is 11% when signals are obtained from the fingers of healthy subjects (Allen and Murray 2000).”
ResultRelation between heart rate and pulse transit time during paced respiration
Drinnan, M. J., Allen, J., & Murray, A. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/3/301 · Cited by 167
Self-citationPhotoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
“The degree of variability has been quantified for amplitude and timing measurements [1], [132].”
BackgroundSelf-citationAllen, J., Frame, J. R., & Murray, A. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/2/312 · Cited by 86
The effect of applied sensor contact force on pulse transit time
Teng, X. F., & Zhang, Y. T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/8/002 · Cited by 53
Sex-Related Differences in Photoplethysmography Signals Measured From Finger and Toe
Dehghanojamahalleh, S., & Kaya, M. (2019) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2019.2938506 · Cited by 25
Metadata
- Authors
- Allen, J., & Murray, A.
- Venue
- IEE Proceedings - Science, Measurement and Technology
- Published
- 2000-11-03
- Volume
- 147
- Issue
- 6
- Pages
- 403-407
- ISSN
- 1350-2344 (ISSN-L)
- 1359-7094
- OpenAlex
- W1985278913
- Cited by
- 76
- References
- 0
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.