Quality Standards for Sample Collection in Coagulation Testing
The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories
Lippi, G., Blanckaert, N., Bonini, P., Green, S., Kitchen, S., Palicka, V., Vassault, A. J., & Plebani, M. (2008) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2008.170 · Cited by 466
Self-citationBazzano, L. A., He, J., Muntner, P., Vupputuri, S., & Whelton, P. K. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-11-200306030-00010 · Cited by 407
Preanalytical quality improvement: from dream to reality
Lippi, G., Chance, J. J., Church, S., Dazzi, P., Fontana, R., Giavarina, D., Grankvist, K., Huisman, W., Kouri, T., Palicka, V., et al. (2011) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.600 · Cited by 388
Self-citationBanfi, G., Salvagno, G. L., & Lippi, G. (2007) · Clinical Chemical Laboratory Medicine · doi:10.1515/cclm.2007.110 · Cited by 297
Self-citationHemolyzed specimens: a major challenge for emergency departments and clinical laboratories
Lippi, G., Plebani, M., Di Somma, S., & Cervellin, G. (2011) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2011.600228 · Cited by 226
Self-citationNarayanan, S. (2000) · American Journal of Clinical Pathology · doi:10.1309/c0nm-q7r0-ll2e-b3uy · Cited by 198
Causes, consequences, detection, and prevention of identification errors in laboratory diagnostics
Lippi, G., Blanckaert, N., Bonini, P., Green, S., Kitchen, S., Palicka, V., Vassault, A. J., Mattiuzzi, C., & Plebani, M. (2009) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2009.045 · Cited by 167
Self-citationPreanalytical and Postanalytical Variables: The Leading Causes of Diagnostic Error in Hemostasis?
Favaloro, E. J., Lippi, G., & Adcock, D. M. (2008) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0028-1104540 · Cited by 166
Self-citationPhlebotomy issues and quality improvement in results of laboratory testing.
Lippi, G., Salvagno, G. L., Montagnana, M., Franchini, M., & Guidi, G. C. (2006) · PubMed · Cited by 159
Self-citationEffect of 3.2%vs3.8% Sodium Citrate Concentration on Routine Coagulation Testing
Adcock, D. M., Kressin, D. C., & Marlar, R. A. (1997) · American Journal of Clinical Pathology · doi:10.1093/ajcp/107.1.105 · Cited by 155
Cited by
Preanalytical quality improvement: in quality we trust
Lippi, G., Becan-McBride, K., Behúlová, D., Bowen, R. A., Church, S., Delanghe, J., Grankvist, K., Kitchen, S., Nybo, M., Nauck, M., et al. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0597 · Cited by 236
“For example, in glass blood collection tubes, the glass interior surface itself plays a key role in the activation of blood coagulation [28] .”
BackgroundSelf-citationHarmonization in laboratory medicine: the complete picture
Plebani, M. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0075 · Cited by 174
“The most prevalent pre-analytical errors are those occurring during the collection of blood specimens; so the definition, implementation, and monitoring of suitable sample collection standards are highly conducive to improving the quality of the testing process [ 50 ].”
BackgroundPreanalytical Variables Affecting the Integrity of Human Biospecimens in Biobanking
Ellervik, C., & Vaught, J. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2014.228783 · Cited by 167
Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories
Magnette, A., Chatelain, M., Chatelain, B., Ten Cate, H., & Mullier, F. (2016) · Thrombosis Journal · doi:10.1186/s12959-016-0123-z · Cited by 166
“Sodium citrated tubes must be filled up to 90% of the nominal volume or to the mark noted on the tube if provided [41, 47].”
BackgroundInfluentialArnold, J. E., Camus, M. S., Freeman, K. P., Giori, L., Hooijberg, E. H., Jeffery, U., Korchia, J., Meindel, M. J., Moore, A. R., Sisson, S. C., et al. (2019) · Veterinary Clinical Pathology · doi:10.1111/vcp.12810 · Cited by 158
Lippi, G., von Meyer, A., Cadamuro, J., & Simundic, A.-M. (2019) · Diagnosis · doi:10.1515/dx-2018-0018 · Cited by 135
Self-citationKershaw, G., Mohammed, S., Lippi, G., & Favaloro, E. (2019) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0038-1677018 · Cited by 96
Self-citationSimundic, A.-M., Cornes, M., Grankvist, K., Lippi, G., Nybo, M., Kovalevskaya, S., Sprongl, L., Sumarac, Z., & Church, S. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0283 · Cited by 84
Self-citationLippi, G., Cervellin, G., & Mattiuzzi, C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.022 · Cited by 66
“Among various preanalytical non-conformances that can be encountered in routine laboratory practice, sample hemolysis represents the primary source of problems, in terms of prevalence and likelihood of sample rejection (3,4).”
BackgroundSelf-citationIncorrect order of draw could be mitigate the patient safety: a phlebotomy management case report
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.026 · Cited by 33
“The PP procedures involving phlebotomy are critical for obtaining diagnostic blood specimens: on the whole they represent a well known and recognized problem, probably among the most important issues in laboratory medicine (2-5).”
BackgroundSelf-citationEffects of vigorous mixing of blood vacuum tubes on laboratory test results
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Gelati, M., Volanski, W., Boritiza, K. C., Picheth, G., & Guidi, G. C. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.10.033 · Cited by 33
Self-citationCould light meal jeopardize laboratory coagulation tests?
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Danese, E., Gelati, M., Montagnana, M., Picheth, G., & Guidi, G. C. (2014) · Biochemia Medica · doi:10.11613/bm.2014.036 · Cited by 30
“Moreover, poor control and standardization of the preanalytical phase in the whole testing process may influence the reliability of coagulation testing in the following points: i) phlebotomy procedure (21-23); ii) venous stasis (11,24): iii) vacuum tube used for blood collection by venipuncture (25).”
BackgroundSelf-citationInfluence of posture on routine hemostasis testing
Lippi, G., Salvagno, G. L., Lima-Oliveira, G., Danese, E., Favaloro, E. J., & Guidi, G. C. (2015) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000326 · Cited by 27
Self-citationGuidance on the critical shortage of sodium citrate coagulation tubes for hemostasis testing
Gosselin, R. C., Bowyer, A., Favaloro, E. J., Johnsen, J. M., Lippi, G., Marlar, R. A., Neeves, K., & Rollins‐Raval, M. A. (2021) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15514 · Cited by 25
Self-citationLima-Oliveira, G., Lippi, G., Salvagno, G. L., Brocco, G., Gaino, S., Dima, F., Volaski, W., Rego, F. G., Picheth, G., & Guidi, G. C. (2014) · Biopreservation and Biobanking · doi:10.1089/bio.2013.0043 · Cited by 22
Self-citationAvoidance to wipe alcohol before venipuncture is not a source of spurious hemolysis
Salvagno, G. L., Danese, E., Lima-Oliveira, G., Guidi, G. C., & Lippi, G. (2013) · Biochemia Medica · doi:10.11613/bm.2013.023 · Cited by 20
“Biochemia Medica 2013;23(2):201–5 http://dx.”
BackgroundSelf-citationPerformance and interpretation of mixing tests in coagulation
Kershaw, G. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-7196-1_6 · Cited by 16
Bostic, G., Thompson, R., Atanasoski, S., Canlas, C., Ye, H., Kolins, M., & Smith, M. D. (2015) · Laboratory Medicine · doi:10.1309/lma4wyn3xfukelbd · Cited by 14
Metadata
- Authors
- Lippi, G., Salvagno, G., Montagnana, M., Lima-Oliveira, G., Guidi, G., & Favaloro, E.
- Venue
- Seminars in Thrombosis and Hemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 2012-06-05
- Volume
- 38
- Issue
- 06
- Pages
- 565-575
- ISSN
- 0094-6176 (ISSN-L)
- 1098-9064
- OpenAlex
- W2051731532
- Cited by
- 196
- References
- 60
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.