Termination of Malignant Ventricular Arrhythmias with an Implanted Automatic Defibrillator in Human Beings
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
THE development of a clinically applicable, automatic, implantable defibrillator has been described previously.1 This electronic device is designed to monitor cardiac electrical activity, to recognize ventricular fibrillation and ventricular tachyarrhythmias with a sinusoidal wave form, and then to deliver corrective defibrillatory discharges. It is intended to protect patients at particularly high risk of sudden death whenever and wherever they are stricken by these lethal arrhythmias.After extensive preclinical testing, 2 a pilot study of this new technique was recently initiated at The Johns Hopkins Hospital. This article decribes the first three patients in whom the automatic defibrillator was implanted to manage . . .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Approaches to Sudden Death from Coronary Heart Disease
LOWN, B., & WOLF, M. (1971) · Circulation · doi:10.1161/01.cir.44.1.130 · Cited by 1,257
Josephson, M. E., Harken, A. H., & Horowitz, L. N. (1979) · Circulation · doi:10.1161/01.cir.60.7.1430 · Cited by 482
Prehospital Ventricular Defibrillation: Prognosis and Follow-up Course
Liberthson, R. R., Nagel, E. L., Hirschman, J. C., & Nussenfeld, S. R. (1974) · New England Journal of Medicine · doi:10.1056/nejm197408152910701 · Cited by 474
Guiraudon, G., Fontaine, G., Frank, R., Escande, G., Etievent, P., & Cabrol, C. (1978) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(10)62923-2 · Cited by 404
Survival after Resuscitation from Out-of-Hospital Ventricular Fibrillation
BAUM, R. S., ALVAREZ, H., & COBB, L. A. (1974) · Circulation · doi:10.1161/01.cir.50.6.1231 · Cited by 364
Schaffer, W. A., & Cobb, L. A. (1975) · New England Journal of Medicine · doi:10.1056/nejm197508072930601 · Cited by 328
Standby Automatic Defibrillator: An Approach to Prevention of Sudden Coronary Death
Mirowski, M. (1970) · Archives of Internal Medicine · doi:10.1001/archinte.1970.00310070160014 · Cited by 221
Self-citationMirowski, M., Mm, M., Langer, A. A., et al. (1978) · Circulation · doi:10.1161/01.cir.58.1.90 · Cited by 133
Self-citation
Cited by
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Writing Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Kuck, K.-H., Cappato, R., Siebels, J., & Rüppel, R. (2000) · Circulation · doi:10.1161/01.cir.102.7.748 · Cited by 1,482
Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02528-7 · Cited by 1,266
Baddour, L. M., Epstein, A. E., Erickson, C. C., Knight, B. P., Levison, M. E., Lockhart, P. B., Masoudi, F. A., Okum, E. J., Wilson, W. R., Beerman, L. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192665 · Cited by 1,030
Bigger, J. T. (1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372201 · Cited by 1,020
The Management of Hypertrophic Cardiomyopathy
Spirito, P., Seidman, C. E., McKenna, W. J., & Maron, B. J. (1997) · New England Journal of Medicine · doi:10.1056/nejm199703133361107 · Cited by 1,007
Committee Members, Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., et al. (2002) · Circulation · doi:10.1161/01.cir.0000035996.46455.09 · Cited by 910
Task Force on Sudden Cardiac Death of the European Society of Cardiology
Priori, S. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2824 · Cited by 903
Maron, B. J., Shen, W.-K., Link, M. S., Epstein, A. E., Almquist, A. K., Daubert, J. P., Bardy, G. H., Favale, S., Rea, R. F., Boriani, G., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002103420601 · Cited by 832
The long QT syndromes: A critical review, new clinical observations and a unifying hypothesis
Jackman, W. M., Friday, K. J., Anderson, J. L., Aliot, E. M., Clark, M., & Lazzara, R. (1988) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(88)90014-x · Cited by 783
Tracy, C. M., Epstein, A. E., Darbar, D., DiMarco, J. P., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P. E., Link, M. S., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 732
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Bänsch, D., Antz, M., Boczor, S., Volkmer, M., Tebbenjohanns, J., Seidl, K., Block, M., Gietzen, F., Berger, J., & Kuck, K. H. (2002) · Circulation · doi:10.1161/01.cir.0000012350.99718.ad · Cited by 646
Safety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter Defibrillator
Weiss, R., Knight, B. P., Gold, M. R., Leon, A. R., Herre, J. M., Hood, M., Rashtian, M., Kremers, M., Crozier, I., Lee, K. L., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.003042 · Cited by 557
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 552
Determinants of Survival in Patients with Ventricular Tachyarrhythmias
Swerdlow, C. D., Winkle, R. A., & Mason, J. W. (1983) · New England Journal of Medicine · doi:10.1056/nejm198306163082402 · Cited by 509
Nonvalvular Cardiovascular Device–Related Infections
Baddour, L. M., Bettmann, M. A., Bolger, A. F., Epstein, A. E., Ferrieri, P., Gerber, M. A., Gewitz, M. H., Jacobs, A. K., Levison, M. E., Newburger, J. W., et al. (2003) · Circulation · doi:10.1161/01.cir.0000093201.57771.47 · Cited by 496
Lambiase, P. D., Barr, C., Theuns, D. A. M. J., Knops, R., Neuzil, P., Johansen, J. B., Hood, M., Pedersen, S., Kääb, S., Murgatroyd, F., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu112 · Cited by 462
Guidelines for implantation of cardiac pacemakers and antiarrhythmia devices
Forcinito, M. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80209-8 · Cited by 399
Increasing rates of cardiac device infections among medicare beneficiaries: 1990–1999
Cabell, C. H., Heidenreich, P. A., Chu, V. H., Moore, C. M., Stryjewski, M. E., Corey, G. R., & Fowler, V. G. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.06.005 · Cited by 397
Tung, R., Zimetbaum, P., & Josephson, M. E. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.058 · Cited by 362
de Oliveira, J. C., Martinelli, M., Nishioka, S. A. D., Varejão, T., Uipe, D., Pedrosa, A. A. A., Costa, R., & Danik, S. B. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.795906 · Cited by 349
Oxley, T. J., Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Wheeler, T. L., Judy, J. W., McDonald, A. J., Dornom, A., Lovell, T. J. H., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3428 · Cited by 339
Wilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.11.018 · Cited by 301
Maron, B. J. (2010) · Circulation · doi:10.1161/circulationaha.109.878579 · Cited by 296
Implantable Cardioverter–Defibrillators
DiMarco, J. P. (2003) · New England Journal of Medicine · doi:10.1056/nejmra035432 · Cited by 290
Guidelines for clinical intracardiac electrophysiological and catheter ablation procedures
Zipes, D. P., Dimarco, J. P., Gillette, P. C., Jackman, W. M., Myerburg, R. J., Rahimtoola, S. H., Ritchie, J. L., Cheitlin, M. D., Garson, A., Gibbons, R. J., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)80037-h · Cited by 282
Implantable Cardioverter-Defibrillators: Expanding Indications and Technologies
Goldberger, Z., & Lampert, R. (2006) · JAMA · doi:10.1001/jama.295.7.809 · Cited by 271
“Because there are no warning symptoms to identify persons who might potentially experience SCD,(4) successful therapy has focused on identifying high-risk patients and treating them with implantable cardioverter-defibrillators (ICDs), which continuously monitor the heart rhythm and deliver a shock or other appropriate…”
BackgroundSurgical Treatment of Pacemaker and Defibrillator Lead Endocarditis
del Río, A., Anguera, I., Miró, J. M., Mont, L., Fowler, V. G., Azqueta, M., & Mestres, C. A. (2003) · Chest · doi:10.1378/chest.124.4.1451 · Cited by 256
Advances In The Prevention And Treatment Of Cardiovascular Disease
Weisfeldt, M. L., & Zieman, S. J. (2007) · Health Affairs · doi:10.1377/hlthaff.26.1.25 · Cited by 250
Self-citationMaron, B. J., Rowin, E. J., Casey, S. A., & Maron, M. S. (2016) · JAMA Cardiology · doi:10.1001/jamacardio.2015.0354 · Cited by 246
Wilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Europace · doi:10.1093/europace/euv411 · Cited by 243
“tion all created a culture of programming for rapid tachycardia detection and the shortest possible time to initial therapy [75–77].”
BackgroundChen, P. S., Shibata, N., Dixon, E. G., Wolf, P. D., Danieley, N. D., Sweeney, M. B., Smith, W. M., & Ideker, R. E. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112378 · Cited by 236
Roguin, A., Bomma, C. S., Nasir, K., Tandri, H., Tichnell, C., James, C., Rutberg, J., Crosson, J., Spevak, P. J., Berger, R. D., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.030 · Cited by 211
FELDMAN, A. M., KLEIN, H., TCHOU, P., MURALI, S., HALL, W. J., MANCINI, D., BOEHMER, J., HARVEY, M., HEILMAN, M. S., SZYMKIEWICZ, S. J., et al. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00378.x · Cited by 210
Self-citationThe Proarrhythmic Potential of Implantable Cardioverter-Defibrillators
Pinski, S. L., & Fahy, G. J. (1995) · Circulation · doi:10.1161/01.cir.92.6.1651 · Cited by 198
Next-generation pacemakers: from small devices to biological pacemakers
Cingolani, E., Goldhaber, J. I., & Marbán, E. (2018) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.165 · Cited by 194
Lickfett, L. (2004) · Europace · doi:10.1016/j.eupc.2003.09.001 · Cited by 193
“The treatment of ventricular tachyarrhythmias was revolutionized by the introduction of implantable cardioverter defibrillators (ICD) to clinical use in 1980 [1].”
Fisher, J. D., Brodman, R., Kim, S. G., Matos, J. A., Elizabeth Brodman, L., Wallerson, D., & Waspe, L. E. (1984) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(84)80394-0 · Cited by 183
Dreifus, L. S., Fisch, C., Griffin, J. C., Gillette, P. C., Mason, J. W., & Parsonnet, V (1991) · Circulation · doi:10.1161/01.cir.84.1.455 · Cited by 178
Nademanee, K., Hendrickson, J., Kannan, R., & Singh, B. N. (1982) · American Heart Journal · doi:10.1016/0002-8703(82)90556-7 · Cited by 176
Antiarrhythmics Versus Implantable Defibrillators (AVID)—Rationale, design, and methods
The AVID Investigators (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80583-9 · Cited by 164
Primary Prevention of Sudden Death as a Novel Treatment Strategy in Hypertrophic Cardiomyopathy
Maron, B. J., Estes, N. A. M., Maron, M. S., Almquist, A. K., Link, M. S., & Udelson, J. E. (2003) · Circulation · doi:10.1161/01.cir.0000072343.81530.75 · Cited by 164
O'Mahony, C., Tome-Esteban, M., Lambiase, P. D., Pantazis, A., Dickie, S., McKenna, W. J., & Elliott, P. M. (2013) · Heart · doi:10.1136/heartjnl-2012-303271 · Cited by 159
Limitations and Late Complications of Third-Generation Automatic Cardioverter-Defibrillators
Nunain, S. O., Roelke, M., Trouton, T., Osswald, S., Kim, Y. H., Sosa-Suarez, G., Brooks, D. R., McGovern, B., Guy, M., Torchiana, D. F., et al. (1995) · Circulation · doi:10.1161/01.cir.91.8.2204 · Cited by 158
Implantable Cardioverter‐Defibrillators for Secondary Prevention of Sudden Cardiac Death: A Review
Borne, R. T., Katz, D., Betz, J., Peterson, P. N., & Masoudi, F. A. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.005515 · Cited by 43
Habibović, M., Denollet, J., Cuijpers, P., van der Voort, P. H., Herrman, J.-P., Bouwels, L., Valk, S. D. A., Alings, M., Theuns, D. A. M. J., & Pedersen, S. S. (2017) · Health Psychology · doi:10.1037/hea0000451 · Cited by 26
Droogan, C., Patel, C., Yan, G.-X., & Kowey, P. R. (2011) · Heart Failure Clinics · doi:10.1016/j.hfc.2010.12.003 · Cited by 10
Guidelines for Managing Pacemaker and Implantable Defibrillator Advisories
Kramer, D. B., & Maisel, W. H. (2011) · Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy · doi:10.1016/b978-1-4377-1616-0.00034-5 · Cited by 8
Metadata
- Authors
- Mirowski, M., Reid, P. R., Mower, M. M., Watkins, L., Gott, V. L., Schauble, J. F., Langer, A., Heilman, M. S., Kolenik, S. A., Fischell, R. E., & Weisfeldt, M. L.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1980-08-07
- Volume
- 303
- Issue
- 6
- Pages
- 322-324
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W1981964073
- Cited by
- 1,361
- References
- 8
- FWCI
- 22.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.