Variability in Radiologists' Interpretations of Mammograms
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Despite the proved value of mammography in screening for breast cancer, its efficacy depends on radiologists' interpretations. The variability in such interpretations is not well understood. METHODS: Using a technique of stratified random sampling, we selected 150 mammograms obtained in 1987: 27 from women with histopathologically confirmed breast cancer and 123 from women with no evidence of breast cancer after three years of follow-up examinations. Ten radiologists, who were unaware of the diagnoses and research hypothesis, each interpreted the 150 mammograms. Disagreement was analyzed within pairs of the 10 radiologists, as well as for the group of 150 women as a whole. RESULTS: The diagnostic consistency between pairs of radiologists was moderate, with a median weighted percentage of agreement of 78 percent (weighted kappa, 0.47). The frequency of the radiologists' recommendations for an immediate workup ranged from 74 to 96 percent for mammograms from the women with cancer and from 11 to 65 percent for films from the women without cancer. A substantial disagreement in management recommendations--in which one radiologist recommended routine follow-up and another recommended a biopsy for the same patient--occurred in 3 percent of the pairwise comparisons but in 25 percent of the comparisons for the group of women as a whole. When two or more radiologists recommended a biopsy for the same patient, a disagreement in the stated location (right or left breast) occurred in 2 percent of the pairwise comparisons among the radiologists but in 9 percent of comparisons for the group of women as a whole. Because some disagreement was likely, given that 10 radiologists read each film, the pairwise comparison is a more conservative estimate of disagreement. CONCLUSIONS: Although mammography is of value in screening women for breast cancer, radiologists can differ, sometimes substantially, in their interpretations of mammograms and in their recommendations for management. Efforts to improve accuracy and reduce variability in interpretation may increase the effectiveness of mammography in detecting early breast cancers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Weighted kappa: nominal scale agreement provision for scaled disagreement or partial credit
Cohen, J. (1968) · Psychological Bulletin · doi:10.1037/h0026256 · Cited by 8,736
Statistical Methods for Rates and Proportions, 2nd ed
GROVE, W. A. (1981) · American Journal of Psychiatry · doi:10.1176/ajp.138.12.1644-a · Cited by 3,748
High agreement but low Kappa: I. the problems of two paradoxes
Feinstein, A. R., & Cicchetti, D. V. (1990) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(90)90158-l · Cited by 3,034
Self-citationREDUCTION IN MORTALITY FROM BREAST CANCER AFTER MASS SCREENING WITH MAMMOGRAPHY
Tabár, L., Gad, A., Holmberg, L. H., Ljungquist, U., Fagerberg, C. J. G., Baldetorp, L., Gröntoft, O., Lundström, B., Månson, J. C., Eklund, G., et al. (1985) · The Lancet · doi:10.1016/s0140-6736(85)92204-4 · Cited by 1,781
Problems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic Tests
Ransohoff, D. F., & Feinstein, A. R. (1978) · New England Journal of Medicine · doi:10.1056/nejm197810262991705 · Cited by 1,734
Self-citationClinical biostatistics: LIV. The biostatistics of concordance
Kramer, M. S., & Feinstein, A. R. (1981) · Clinical Pharmacology and Therapeutics · doi:10.1038/clpt.1981.18 · Cited by 1,087
Self-citationMammographic screening and mortality from breast cancer: the Malmö mammographic screening trial.
Andersson, I., Aspegren, K., Janzon, L., Landberg, T., Lindholm, K., Linell, F., Ljungberg, O., Ranstam, J., & Sigfússon, B. (1988) · BMJ · doi:10.1136/bmj.297.6654.943 · Cited by 916
Ten- to Fourteen-Year Effect of Screening on Breast Cancer Mortality 2
(1982) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/69.2.349 · Cited by 840
REDUCTION OF BREAST CANCER MORTALITY THROUGH MASS SCREENING WITH MODERN MAMMOGRAPHY
Verbeek, A. L. M., Holland, R., Sturmans, F., Hendriks, J. H. C. L., Avunac, M., & Day, N. E. (1984) · The Lancet · doi:10.1016/s0140-6736(84)91703-3 · Cited by 495
Cited by
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · BMC Medical Research Methodology · doi:10.1186/1471-2288-1-2 · Cited by 2,755
STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration
Cohen, J. F., Korevaar, D. A., Altman, D. G., Bruns, D. E., Gatsonis, C. A., Hooft, L., Irwig, L., Levine, D., Reitsma, J. B., de Vet, H. C. W., et al. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012799 · Cited by 2,570
Breast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Incidence and Types of Adverse Events and Negligent Care in Utah and Colorado
Thomas, E. J., Studdert, D. M., Burstin, H. R., Orav, E. J., Zeena, T., Williams, E. J., Howard, K. M., Weiler, P. C., & Brennan, T. A. (2000) · Medical Care · doi:10.1097/00005650-200003000-00003 · Cited by 1,673
Measurement of Observer Agreement
Kundel, H. L., & Polansky, M. (2003) · Radiology · doi:10.1148/radiol.2282011860 · Cited by 1,492
Kuhl, C. K., Mielcareck, P., Klaschik, S., Leutner, C., Wardelmann, E., Gieseke, J., & Schild, H. H. (1999) · Radiology · doi:10.1148/radiology.211.1.r99ap38101 · Cited by 1,277
Berg, W. A., Campassi, C., Langenberg, P., & Sexton, M. J. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.6.1741769 · Cited by 1,273
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
“Many studies have shown reader variability, especially in the field of imaging (43, 44).”
Elmore, J. G. (2005) · JAMA · doi:10.1001/jama.293.10.1245 · Cited by 1,075
Self-citationThe incidence and nature of surgical adverse events in Colorado and Utah in 1992
Gawande, A. A., Thomas, E. J., Zinner, M. J., & Brennan, T. A. (1999) · Surgery · doi:10.1067/msy.1999.98664 · Cited by 977
Grading and staging systems for inflammation and fibrosis in chronic liver diseases
Goodman, Z. D. (2007) · Journal of Hepatology · doi:10.1016/j.jhep.2007.07.006 · Cited by 884
The art and science of clinical knowledge: evidence beyond measures and numbers
Malterud, K. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05548-9 · Cited by 847
Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
Diagnostic Concordance Among Pathologists Interpreting Breast Biopsy Specimens
Elmore, J. G., Longton, G. M., Carney, P. A., Geller, B. M., Onega, T., Tosteson, A. N. A., Nelson, H. D., Pepe, M. S., Allison, K. H., Schnitt, S. J., et al. (2015) · JAMA · doi:10.1001/jama.2015.1405 · Cited by 751
“001 Atypia 72 2070 17 (15-21) 35 (31-39) 48 (44-52)”
Self-citationDickinson, L., Ahmed, H. U., Allen, C., Barentsz, J. O., Carey, B., Futterer, J. J., Heijmink, S. W., Hoskin, P. J., Kirkham, A., Padhani, A. R., et al. (2011) · European Urology · doi:10.1016/j.eururo.2010.12.009 · Cited by 737
Krause, J., Gulshan, V., Rahimy, E., Karth, P., Widner, K., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.034 · Cited by 564
Zheng, B., Yoon, S. W., & Lam, S. S. (2014) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.08.044 · Cited by 549
An expert system for detection of breast cancer based on association rules and neural network
Karabatak, M., & Ince, M. C. (2009) · Expert Systems with Applications · doi:10.1016/j.eswa.2008.02.064 · Cited by 494
Farmer, E. R., Gonin, R., & Hanna, M. P. (1996) · Human Pathology · doi:10.1016/s0046-8177(96)90157-4 · Cited by 440
Elmore, J. G., Barnhill, R. L., Elder, D. E., Longton, G. M., Pepe, M. S., Reisch, L. M., Carney, P. A., Titus, L. J., Nelson, H. D., Onega, T., et al. (2017) · BMJ · doi:10.1136/bmj.j2813 · Cited by 436
Self-citationRegional Variations in Diagnostic Practices
Song, Y., Skinner, J., Bynum, J., Sutherland, J., Wennberg, J. E., & Fisher, E. S. (2010) · New England Journal of Medicine · doi:10.1056/nejmsa0910881 · Cited by 430
Sayres, R., Taly, A., Rahimy, E., Blumer, K., Coz, D., Hammel, N., Krause, J., Narayanaswamy, A., Rastegar, Z., Wu, D., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2018.11.016 · Cited by 418
Effects of Estrogen and Estrogen–Progestin on Mammographic Parenchymal Density
Greendale, G. A., Reboussin, B. A., Sie, A., Singh, H. R., Olson, L. K., Gatewood, O., Bassett, L. W., Wasilauskas, C., Bush, T., Barrett-Connor, E., et al. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-4_part_1-199902160-00003 · Cited by 401
Assessing the quality of research.
Glasziou, P., Vandenbroucke, J., & Chalmers, I. (2004) · BMJ · doi:10.1136/bmj.328.7430.39 · Cited by 391
Interobserver Variability in Applying a Radiographic Definition for ARDS
Rubenfeld, G. D., Caldwell, E., Granton, J., Hudson, L. D., & Matthay, M. A. (1999) · Chest · doi:10.1378/chest.116.5.1347 · Cited by 382
Langlotz, C. P., Allen, B., Erickson, B. J., Kalpathy-Cramer, J., Bigelow, K., Cook, T. S., Flanders, A. E., Lungren, M. P., Mendelson, D. S., Rudie, J. D., et al. (2019) · Radiology · doi:10.1148/radiol.2019190613 · Cited by 368
The Reproducibility of a Method to Identify the Overuse and Underuse of Medical Procedures
Shekelle, P. G., Kahan, J. P., Bernstein, S. J., Leape, L. L., Kamberg, C. J., & Park, R. E. (1998) · New England Journal of Medicine · doi:10.1056/nejm199806253382607 · Cited by 368
Performance Benchmarks for Screening Mammography
Rosenberg, R. D., Yankaskas, B. C., Abraham, L. A., Sickles, E. A., Lehman, C. D., Geller, B. M., Carney, P. A., Kerlikowske, K., Buist, D. S. M., Weaver, D. L., et al. (2006) · Radiology · doi:10.1148/radiol.2411051504 · Cited by 336
Implementation of Breast Tomosynthesis in a Routine Screening Practice: An Observational Study
Rose, S. L., Tidwell, A. L., Bujnoch, L. J., Kushwaha, A. C., Nordmann, A. S., & Sexton, R. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9672 · Cited by 329
Thermography Based Breast Cancer Detection Using Texture Features and Support Vector Machine
Acharya, U. R., Ng, E. Y. K., Tan, J.-H., & Sree, S. V. (2012) · Journal of Medical Systems · doi:10.1007/s10916-010-9611-z · Cited by 316
Gur, D., Sumkin, J. H., Rockette, H. E., Ganott, M., Hakim, C., Hardesty, L., Poller, W. R., Shah, R., & Wallace, L. (2004) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djh067 · Cited by 306
A systematic survey of computer-aided diagnosis in medicine: Past and present developments
Yanase, J., & Triantaphyllou, E. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.112821 · Cited by 303
“For instance, in a study by Elmore and his associates [Elmore, et al., 1994] it was found that 90% of radiologists had recognized fewer than 3% of the mammograms that they had screened 5 months prior to that time, while 10% had claimed to have recognized about 25% of the cases.”
ResultKerlikowske, K., Grady, D., Barclay, J., Ernster, V., Frankel, S. D., Ominsky, S. H., & Sickles, E. A. (1998) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/90.23.1801 · Cited by 298
Newman, E. A., Guest, A. B., Helvie, M. A., Roubidoux, M. A., Chang, A. E., Kleer, C. G., Diehl, K. M., Cimmino, V. M., Pierce, L., Hayes, D., et al. (2006) · Cancer · doi:10.1002/cncr.22266 · Cited by 290
Thomas, K. E., Hasbun, R., Jekel, J., & Quagliarello, V. J. (2002) · Clinical Infectious Diseases · doi:10.1086/340979 · Cited by 287
A Similarity Learning Approach to Content-Based Image Retrieval: Application to Digital Mammography
El-Naqa, I., Yang, Y., Galatsanos, N. P., Nishikawa, R. M., & Wernick, M. N. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.834601 · Cited by 287
A systematic review classifies sources of bias and variation in diagnostic test accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., & Mallett, S. (2013) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2013.05.014 · Cited by 283
Missed Breast Carcinoma: Pitfalls and Pearls
Majid, A. S., de Paredes, E. S., Doherty, R. D., Sharma, N. R., & Salvador, X. (2003) · RadioGraphics · doi:10.1148/rg.234025083 · Cited by 275
Elmore, J. G., Jackson, S. L., Abraham, L., Miglioretti, D. L., Carney, P. A., Geller, B. M., Yankaskas, B. C., Kerlikowske, K., Onega, T., Rosenberg, R. D., et al. (2009) · Radiology · doi:10.1148/radiol.2533082308 · Cited by 263
Self-citationAvoiding the Unintended Consequences of Growth in Medical Care: How Might More Be Worse?
Fisher, E. S., & Welch, H. G. (1999) · JAMA · doi:10.1001/jama.281.5.446 · Cited by 251
PanNuke: An Open Pan-Cancer Histology Dataset for Nuclei Instance Segmentation and Classification
Gamper, J., Alemi Koohbanani, N., Benet, K., Khuram, A., & Rajpoot, N. (2019) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-23937-4_2 · Cited by 245
Automated Breast Cancer Diagnosis Based on Machine Learning Algorithms
Dhahri, H., Al Maghayreh, E., Mahmood, A., Elkilani, W., & Faisal Nagi, M. (2019) · Journal of Healthcare Engineering · doi:10.1155/2019/4253641 · Cited by 239
“Many imaging techniques have been developed for early detection and treatment of breast cancer and to reduce the number of deaths [2], and many aided breast cancer diagnosis methods have been used to increase the diagnostic accuracy [3, 4].”
MethodClinimetrics: the science of clinical measurements
Fava, G. A., Tomba, E., & Sonino, N. (2012) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2011.02825.x · Cited by 233
Doing Well by Making Well: The Impact of Corporate Wellness Programs on Employee Productivity
Gubler, T., Larkin, I., & Pierce, L. (2018) · Management Science · doi:10.1287/mnsc.2017.2883 · Cited by 222
Epidemiology of acute lung injury
Rubenfeld, G. D. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000057904.62683.2b · Cited by 222
Skaane, P., Young, K., & Skjennald, A. (2003) · Radiology · doi:10.1148/radiol.2293021171 · Cited by 221
Accuracy of Screening Mammography Interpretation by Characteristics of Radiologists
Barlow, W. E., Chi, C., Carney, P. A., Taplin, S. H., D'Orsi, C., Cutter, G., Hendrick, R. E., & Elmore, J. G. (2004) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djh333 · Cited by 216
“The accuracy of mammographic interpretation among individual radiologists varies widely ( 4 ,5).”
BackgroundSelf-citationBerg, W. A., D’Orsi, C. J., Jackson, V. P., Bassett, L. W., Beam, C. A., Lewis, R. S., & Crewson, P. E. (2002) · Radiology · doi:10.1148/radiol.2243011626 · Cited by 208
Shi, Z., Miao, C., Schoepf, U. J., Savage, R. H., Dargis, D. M., Pan, C., Chai, X., Li, X. L., Xia, S., Zhang, X., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19527-w · Cited by 207
Ljung, B.-M., Drejet, A., Chiampi, N., Jeffrey, J., Goodson, W. H., Chew, K., Moore, D. H., & Miller, T. R. (2001) · Cancer · doi:10.1002/cncr.9040 · Cited by 206
Chou, S.-M., Lee, T.-S., Shao, Y. E., & Chen, I.-F. (2004) · Expert Systems with Applications · doi:10.1016/j.eswa.2003.12.013 · Cited by 206
“However, literature has reported that radiologists show considerable variation in interpreting a mammography (Elmore et al., 1994).”
BackgroundAttention-Enriched Deep Learning Model for Breast Tumor Segmentation in Ultrasound Images
Vakanski, A., Xian, M., & Freer, P. E. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.06.015 · Cited by 196
Context Bias: A Problem in Diagnostic Radiology
Egglin, T. K. P. (1996) · JAMA · doi:10.1001/jama.1996.03540210060035 · Cited by 192
Who Said What: Modeling Individual Labelers Improves Classification
Guan, M., Gulshan, V., Dai, A., & Hinton, G. (2018) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v32i1.11756 · Cited by 191
The Applications of Genetic Algorithms in Medicine
Ghaheri, A., Shoar, S., Naderan, M., & Hoseini, S. S. (2015) · Oman Medical Journal · doi:10.5001/omj.2015.82 · Cited by 186
Baker, J. A., Kornguth, P. J., & Floyd, C. E. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.4.8610547 · Cited by 178
“ment recommendations for breast lesions [ 4-6 ], none have TABLE I : Terms Included in the ACR BI-RADS Standardized”
BackgroundMethodAutomated computerized classification of malignant and benign masses on digitized mammograms
Huo, Z., Giger, M. L., Vyborny, C. J., Wolverton, D. E., Schmidt, R. A., & Doi, K. (1998) · Academic Radiology · doi:10.1016/s1076-6332(98)80278-x · Cited by 167
International Variation in Screening Mammography Interpretations in Community-Based Programs
Elmore, J. G., Nakano, C. Y., Koepsell, T. D., Desnick, L. M., D'Orsi, C. J., & Ransohoff, D. F. (2003) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djg048 · Cited by 166
Self-citationAccuracy of Diagnostic Procedures: Has It Improved Over the Past Five Decades?
Berlin, L. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1270 · Cited by 165
“A 1994 study at Yale University School of Medicine found on retrospective review of mammograms originally interpreted by experienced radiologists as normal that from 15% to 63% of breast carcinomas had been overlooked at the initial interpretations [53].”
Redondo, A., Comas, M., Macià, F., Ferrer, F., Murta-Nascimento, C., Maristany, M. T., Molins, E., Sala, M., & Castells, X. (2012) · The British Journal of Radiology · doi:10.1259/bjr/21256379 · Cited by 162
“Previous studies also reported fair to moderate variability in interobserver mammographie interpretation [9, 14, 18, 19].”
BackgroundEvaluating Imaging and Computer-aided Detection and Diagnosis Devices at the FDA
Gallas, B. D., Chan, H.-P., D’Orsi, C. J., Dodd, L. E., Giger, M. L., Gur, D., Krupinski, E. A., Metz, C. E., Myers, K. J., Obuchowski, N. A., et al. (2012) · Academic Radiology · doi:10.1016/j.acra.2011.12.016 · Cited by 81
“Demonstrations of this reader variability in the interpretation of mammograms are given in reports by Elmore et al (20) and Beam et al (21).”
MethodRadiology-GPT: A Large Language Model for Radiology
Liu, Z., Zhong, A., Li, Y., Yang, L., Ju, C., Wu, Z., Ma, C., Shu, P., Chen, C., Kim, S., et al. (2023) · arXiv · doi:10.48550/arxiv.2306.08666 · Cited by 59
“There could be significant variations in how different radiologists interpret the same set of radiology findings [39, 40, 41].”
Artificial Intelligence in Medicine: Validation and Study Design
Oakden-Rayner, L., & Palmer, L. J. (2019) · Artificial Intelligence in Medical Imaging · doi:10.1007/978-3-319-94878-2_8 · Cited by 14
Metadata
- Authors
- Elmore, J. G., Wells, C. K., Lee, C. H., Howard, D. H., & Feinstein, A. R.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1994-12
- Volume
- 331
- Issue
- 22
- Pages
- 1493-1499
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2010120422
- Cited by
- 601
- References
- 17
- FWCI
- 18.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.