The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Abstract
BACKGROUND: An accurate, noninvasive technique for the diagnosis of coronary disease would be an important advance. We investigated the accuracy of coronary magnetic resonance angiography among patients with suspected coronary disease in a prospective, multicenter study. METHODS: Coronary magnetic resonance angiography was performed during free breathing in 109 patients before elective x-ray coronary angiography, and the results of the two diagnostic procedures were compared. RESULTS: A total of 636 of 759 proximal and middle segments of coronary arteries (84 percent) were interpretable on magnetic resonance angiography. In these segments, 78 (83 percent) of 94 clinically significant lesions (those with a > or = 50 percent reduction in diameter on x-ray angiography) were also detected by magnetic resonance angiography. Overall, coronary magnetic resonance angiography had an accuracy of 72 percent (95 percent confidence interval, 63 to 81 percent) in diagnosing coronary artery disease. The sensitivity, specificity, and accuracy for patients with disease of the left main coronary artery or three-vessel disease were 100 percent (95 percent confidence interval, 97 to 100 percent), 85 percent (95 percent confidence interval, 78 to 92 percent), and 87 percent (95 percent confidence interval, 81 to 93 percent), respectively. The negative predictive values for any coronary artery disease and for left main artery or three-vessel disease were 81 percent (95 percent confidence interval, 73 to 89 percent) and 100 percent (95 percent confidence interval, 97 to 100 percent), respectively. CONCLUSIONS: Among patients referred for their first x-ray coronary angiogram, three-dimensional coronary magnetic resonance angiography allows for the accurate detection of coronary artery disease of the proximal and middle segments. This noninvasive approach reliably identifies (or rules out) left main coronary artery or three-vessel disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive technique for high-definition MR imaging of moving structures.
Ehman, R. L., & Felmlee, J. P. (1989) · Radiology · doi:10.1148/radiology.173.1.2781017 · Cited by 801
Coronary angiography with multi-slice computed tomography
Nieman, K., Oudkerk, M., Rensing, B. J., van Ooijen, P., Munne, A., van Geuns, R.-J., & de Feyter, P. J. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04058-7 · Cited by 725
A Preliminary Report Comparing Magnetic Resonance Coronary Angiography with Conventional Angiography
Manning, W. J., Li, W., & Edelman, R. R. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303253281202 · Cited by 544
Self-citationBudoff, M. J., Georgiou, D., Brody, A., Agatston, A. S., Kennedy, J., Wolfkiel, C., Stanford, W., Shields, P., Lewis, R. J., Janowitz, W. R., et al. (1996) · Circulation · doi:10.1161/01.cir.93.5.898 · Cited by 488
Improved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRA
Botnar, R. M., Stuber, M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Circulation · doi:10.1161/01.cir.99.24.3139 · Cited by 425
Self-citationCardiac Catheterization, Angiography, and Intervention
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-115-8-664_3 · Cited by 423
Achenbach, S., Moshage, W., Ropers, D., Nossen, J., & Daniel, W. G. (1998) · New England Journal of Medicine · doi:10.1056/nejm199812313392702 · Cited by 382
Coronary arteries: breath-hold MR angiography.
Edelman, R. R., Manning, W. J., Burstein, D., & Paulin, S. (1991) · Radiology · doi:10.1148/radiology.181.3.1947074 · Cited by 361
Self-citationPost, J. C., van Rossum, A. C., Bronzwaer, J. G. F., de Cock, C. C., Hofman, M. B. M., Valk, J., & Visser, C. A. (1995) · Circulation · doi:10.1161/01.cir.92.11.3163 · Cited by 339
Stuber, M., Botnar, R. M., Danias, P. G., Sodickson, D. K., Kissinger, K. V., Van Cauteren, M., De Becker, J., & Manning, W. J. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00223-5 · Cited by 320
Self-citationStuber, M., Botnar, R. M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Radiology · doi:10.1148/radiology.212.2.r99au50579 · Cited by 256
Self-citationTwo-dimensional coronary MR angiography: analysis of initial clinical results.
Duerinckx, A. J., & Urman, M. K. (1994) · Radiology · doi:10.1148/radiology.193.3.7972815 · Cited by 224
van der Zwet, P. M. J., & Reiber, J. H. C. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90566-5 · Cited by 205
Assessment of coronary artery stenosis by magnetic resonance imaging.
Pennell, D. J., Bogren, H. G., Keegan, J., Firmin, D. N., & Underwood, S. R. (1996) · Heart · doi:10.1136/hrt.75.2.127 · Cited by 158
Coronary Arterial Stents: Safety and Artifacts during MR Imaging
Hug, J., Nagel, E. C., Bornstedt, A., Schnackenburg, B., Oswald, H., & Fleck, E. (2000) · Radiology · doi:10.1148/radiology.216.3.r00se03781 · Cited by 140
Self-citationSawyer-Glover, A. M., & Shellock, F. G. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<92::aid-jmri11>3.0.co;2-7 · Cited by 140
Proximal coronary artery stenosis: Three‐dimensional MRI with fat saturation and navigator echo
Müller, M. F., Fleisch, M., Kroeker, R. M., Chatterjee, T. K., Meier, B., & Vock, P. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070406 · Cited by 135
Intravenous Coronary Angiography by Electron Beam Computed Tomography
Rensing, B. J. W. M., Bongaerts, A. H. H., van Geuns, R., van Ooijen, P. M. A., Oudkerk, M., & de Feyter, P. J. (1998) · Circulation · doi:10.1161/01.cir.98.23.2509 · Cited by 128
Regenfus, M., Ropers, D., Achenbach, S. S., Kessler, W., Laub, G. A., Daniel, W. G., & Moshage, W. E. L. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00672-0 · Cited by 126
MR Coronary Angiography with Breath-hold Targeted Volumes: Preliminary Clinical Results
van Geuns, R., Wielopolski, P. A., de Bruin, H. G., Rensing, B. J. W. M., Hulshoff, M., van Ooijen, P. M. A., de Feyter, P. J., & Oudkerk, M. (2000) · Radiology · doi:10.1148/radiology.217.1.r00oc01270 · Cited by 113
Woodard, P. K., Li, D., Haacke, E. M., Dhawale, P. J., Kaushikkar, S., Barzilai, B., Braverman, A. C., Ludbrook, P. A., Weiss, A. N., Brown, J. J., et al. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.4.9530027 · Cited by 91
Hillis, L. D., & Winniford, M. D. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90814-9 · Cited by 11
Cited by
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · BMC Medical Research Methodology · doi:10.1186/1471-2288-1-2 · Cited by 2,755
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
Greenwood, J. P., Maredia, N., Younger, J. F., Brown, J. M., Nixon, J., Everett, C. C., Bijsterveld, P., Ridgway, J. P., Radjenovic, A., Dickinson, C. J., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61335-4 · Cited by 1,114
Self-citation
Metadata
- Authors
- Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., Botnar, R. M., & Manning, W. J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2001-12-27
- Volume
- 345
- Issue
- 26
- Pages
- 1863-1869
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W1982676263
- Cited by
- 903
- References
- 22
- FWCI
- 52.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.