The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
An Entirely Subcutaneous Implantable Cardioverter–Defibrillator
Open accessAbstract
BACKGROUND: Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS: First, we conducted two short-term clinical trials to identify a suitable device configuration and assess energy requirements. We evaluated four subcutaneous ICD configurations in 78 patients who were candidates for ICD implantation and subsequently tested the best configuration in 49 additional patients to determine the subcutaneous defibrillation threshold in comparison with that of the standard transvenous ICD. Then we evaluated the long-term use of subcutaneous ICDs in a pilot study, involving 6 patients, which was followed by a trial involving 55 patients. RESULTS: The best device configuration consisted of a parasternal electrode and a left lateral thoracic pulse generator. This configuration was as effective as a transvenous ICD for terminating induced ventricular fibrillation, albeit with a significantly higher mean (+/-SD) energy requirement (36.6+/-19.8 J vs. 11.1+/-8.5 J). Among patients who received a permanent subcutaneous ICD, ventricular fibrillation was successfully detected in 100% of 137 induced episodes. Induced ventricular fibrillation was converted twice in 58 of 59 patients (98%) with the delivery of 65-J shocks in two consecutive tests. Clinically significant adverse events included two pocket infections and four lead revisions. After a mean of 10+/-1 months, the device had successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. CONCLUSIONS: In small, nonrandomized studies, an entirely subcutaneous ICD consistently detected and converted ventricular fibrillation induced during electrophysiological testing. The device also successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. (ClinicalTrials.gov numbers, NCT00399217 and NCT00853645.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical principles in experimental design.
Winer, B. J. (1962) · McGraw-Hill Book Company · doi:10.1037/11774-000 · Cited by 26,755
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Self-citation(1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,232
Writing Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Management and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infections
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S., & Baddour, L. M. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.072 · Cited by 751
Kleemann, T., Becker, T., Doenges, K., Vater, M., Senges, J., Schneider, S., Saggau, W., Weisse, U., & Seidl, K. (2007) · Circulation · doi:10.1161/circulationaha.106.663807 · Cited by 634
Statistical Methods in Medical Research, 4th edn
Purdie, D. (2003) · Internal Medicine Journal · doi:10.1046/j.1445-5994.2002.00319.x · Cited by 492
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.015 · Cited by 468
Tung, R., Zimetbaum, P., & Josephson, M. E. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.058 · Cited by 362
Pacemaker and ICD Generator Malfunctions: Analysis of Food and Drug Administration Annual Reports
Maisel, W. H., Moynahan, M., Zuckerman, B. D., Gross, T. P., Tovar, O. H., Tillman, D.-B., & Schultz, D. B. (2006) · JAMA · doi:10.1001/jama.295.16.1901 · Cited by 353
Khairy, P., Landzberg, M. J., Gatzoulis, M. A., Mercier, L.-A., Fernandes, S. M., Côté, J.-M., Lavoie, J.-P., Fournier, A., Guerra, P. G., Frogoudaki, A., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.622076 · Cited by 300
Sacher, F., Probst, V., Iesaka, Y., Jacon, P., Laborderie, J., Mizon-Gérard, F., Mabo, P., Reuter, S., Lamaison, D., Takahashi, Y., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.628537 · Cited by 293
ALEXANDER, M. E., CECCHIN, F., WALSH, E. P., TRIEDMAN, J. K., BEVILACQUA, L. M., & BERUL, C. I. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03388.x · Cited by 281
Intravascular Extraction of Problematic or Infected Permanent Pacemaker Leads: 1994–1996
BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., TURK, K. T., REEVES, R., YOUNG, R., CREVEY, B., KUTALEK, S. P., FREEDMAN, R., et al. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00628.x · Cited by 279
Complications of Implantable Cardioverter Defibrillator Therapy in 440 Consecutive Patients
ALTER, P., WALDHANS, S., PLACHTA, E., MOOSDORF, R., & GRIMM, W. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00195.x · Cited by 274
de Acosta, J., & Markham, C. R. (2009) · Cambridge University Press eBooks · Cited by 266
Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead
Hauser, R. G., Kallinen, L. M., Almquist, A. K., Gornick, C. C., & Katsiyiannis, W. T. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.03.041 · Cited by 247
Incidence and Risk Factors of Early Venous Thrombosis Associated with Permanent Pacemaker Leads
VAN ROODEN, C. J., MOLHOEK, S. G., ROSENDAAL, F. R., SCHALIJ, M. J., MEINDERS, A. E., & HUISMAN, M. V. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04081.x · Cited by 190
Detection and management of animplantable cardioverter defibrillator lead failure
Ellenbogen, K. A., Wood, M. A., Shepard, R. K., Clemo, H. F., Vaughn, T., Holloman, K., Dow, M., Leffler, J., Abeyratne, A., & Verness, D. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02620-7 · Cited by 164
Necessity for Surgical Revision of Defibrillator Leads Implanted Long-Term
Eckstein, J., Koller, M., Zabel, M., Kalusche, D., Schaer, B. A., Osswald, S., & Sticherling, C. (2008) · Circulation · doi:10.1161/circulationaha.107.740670 · Cited by 150
Implantable Cardioverter–Defibrillators after Myocardial Infarction
Myerburg, R. J. (2008) · New England Journal of Medicine · doi:10.1056/nejmra0803409 · Cited by 138
Transvenous Defibrillation Leads: High Incidence of Failure During Long‐Term Follow‐Up
Dorwarth, U., Frey, B., Dugas, M., Matis, T., Fiek, M., Schmoeckel, M., REMP, T., DURCHLAUB, I., GERTH, A., Steinbeck, G., et al. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.02305.x · Cited by 134
Implantable cardioverter defibrillators after myocardial infarction.
Bonny, A., Ditah, I. C., & Tonga, N. (2009) · PubMed · Cited by 123
Al‐Khatib, S. M., Greiner, M. A., Peterson, E. D., Hernandez, A. F., Schulman, K. A., & Curtis, L. H. (2008) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.777888 · Cited by 116
Lessons From the Failure and Recall of an Implantable Cardioverter-Defibrillator
Hauser, R. G., & Maron, B. J. (2005) · Circulation · doi:10.1161/circulationaha.105.580381 · Cited by 102
Danik, S. B., MANSOUR, M. C., Singh, J. P., Reddy, V. Y., Ellinor, P. T., Milan, D. J., Heist, E. K., d’Ávila, A., Ruskin, J. N., & Mela, T. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2006.12.044 · Cited by 100
Semper Fidelis — Consumer Protection for Patients with Implanted Medical Devices
Maisel, W. H. (2008) · New England Journal of Medicine · doi:10.1056/nejmp0800495 · Cited by 98
Risks and Challenges of Implantable Cardioverter-Defibrillators in Young Adults
Sherrid, M. V., & Daubert, J. P. (2008) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2008.10.001 · Cited by 80
Accelerating risk of Fidelis lead fracture
Farwell, D. J., Green, M. S., Lemery, R., Gollob, M. H., & Birnie, D. H. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.06.024 · Cited by 79
Complications of Third‐Generation Implantable Cardioverter Defibrillator Therapy
Grimm, W., Menz, V., Hoffmann, J., Timmann, U., FUNCK, R. C., Moosdorf, R., & Maisch, B. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00334.x · Cited by 74
Outcome of advisory implantable cardioverter-defibrillator replacement: One-year follow-up
Gould, P. A., Gula, L. J., Champagne, J., Healey, J. S., Cameron, D., Simpson, C., Thibault, B., Pintér, A., Tung, S., Sterns, L. D., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.09.020 · Cited by 70
A computer modeling tool for comparing novel ICD electrode orientations in children and adults
Jolley, M. A., Stinstra, J. G., Pieper, S., MacLeod, R., Brooks, D. H., Cecchin, F., & Triedman, J. K. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.01.018 · Cited by 68
Duray, G. Z., Schmitt, J., Cicek-Hartvig, S., Hohnloser, S. H., & Israel, C. W. (2008) · EP Europace · doi:10.1093/europace/eun322 · Cited by 65
Performance of the St. Jude Medical Riata Leads
Epstein, A. E., Baker, J. H., Beau, S. L., Deering, T. F., Greenberg, S. M., & Goldman, D. S. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.10.030 · Cited by 62
Benefits of the Implantable Cardioverter-Defibrillator
Epstein, A. E. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.06.035 · Cited by 40
Lieberman, R. A., Havel, W. J., Rashba, E. J., DeGroot, P., Stromberg, K. D., & Shorofsky, S. R. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.08.030 · Cited by 33
The Sprint Fidelis lead fracture story: What do we really know and where do we go from here?
Ellenbogen, K. A., Wood, M. A., & Swerdlow, C. D. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.08.001 · Cited by 19
The Fidelis Recall: How Much Pressure Can the ICD World Bear?
Cannom, D. S., & Fisher, J. D. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01170.x · Cited by 14
Implantable cardioverter-defibrillator lead complication: When is an outbreak out of bounds?
Maisel, W. H. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.10.014 · Cited by 8
The “natural” history of implantable defibrillators under advisory
Schoenfeld, M. H. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.10.010 · Cited by 6
Lelakowski, J., Majewski, J., Małecka, B., et al. (2007) · PubMed · Cited by 4
Cited by
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab670 · Cited by 19,442
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429
2016 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.592 · Cited by 5,866
2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy
Authors/Task Force members, Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu284 · Cited by 4,332
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Metadata
- Authors
- Bardy, G. H., Smith, W. M., Hood, M. A., Crozier, I. G., Melton, I. C., Jordaens, L., Theuns, D., Park, R. E., Wright, D. J., Connelly, D. T., Fynn, S. P., Murgatroyd, F. D., Sperzel, J., Neuzner, J., Spitzer, S. G., Ardashev, A. V., Oduro, A., Boersma, L., Maass, A. H., Van Gelder, I. C., Wilde, A. A., van Dessel, P. F., Knops, R. E., Barr, C. S., Lupo, P., Cappato, R., & Grace, A. A.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2010-07
- Volume
- 363
- Issue
- 1
- Pages
- 36-44
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2139305230
- Cited by
- 780
- References
- 42
- FWCI
- 30.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.