The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Cerebral Embolic Protection during Transcatheter Aortic-Valve Replacement
Open accessAbstract
BACKGROUND: Transcatheter aortic-valve replacement (TAVR) for the treatment of aortic stenosis can lead to embolization of debris. Capture of debris by devices that provide cerebral embolic protection (CEP) may reduce the risk of stroke. METHODS: We randomly assigned patients with aortic stenosis in a 1:1 ratio to undergo transfemoral TAVR with CEP (CEP group) or without CEP (control group). The primary end point was stroke within 72 hours after TAVR or before discharge (whichever came first) in the intention-to-treat population. Disabling stroke, death, transient ischemic attack, delirium, major or minor vascular complications at the CEP access site, and acute kidney injury were also assessed. A neurology professional examined all the patients at baseline and after TAVR. RESULTS: A total of 3000 patients across North America, Europe, and Australia underwent randomization; 1501 were assigned to the CEP group and 1499 to the control group. A CEP device was successfully deployed in 1406 of the 1489 patients (94.4%) in whom an attempt was made. The incidence of stroke within 72 hours after TAVR or before discharge did not differ significantly between the CEP group and the control group (2.3% vs. 2.9%; difference, -0.6 percentage points; 95% confidence interval, -1.7 to 0.5; P = 0.30). Disabling stroke occurred in 0.5% of the patients in the CEP group and in 1.3% of those in the control group. There were no substantial differences between the CEP group and the control group in the percentage of patients who died (0.5% vs. 0.3%); had a stroke, a transient ischemic attack, or delirium (3.1% vs. 3.7%); or had acute kidney injury (0.5% vs. 0.5%). One patient (0.1%) had a vascular complication at the CEP access site. CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral TAVR, the use of CEP did not have a significant effect on the incidence of periprocedural stroke, but on the basis of the 95% confidence interval around this outcome, the results may not rule out a benefit of CEP during TAVR. (Funded by Boston Scientific; PROTECTED TAVR ClinicalTrials.gov number, NCT04149535.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationTranscatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients
Leon, M. B., Smith, C. R., Mack, M. J., Makkar, R. R., Svensson, L. G., Kodali, S. K., Thourani, V. H., Tuzcu, E. M., Miller, D. C., Herrmann, H. C., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1514616 · Cited by 5,053
Self-citationTranscatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
Mack, M. J., Leon, M. B., Thourani, V. H., Makkar, R., Kodali, S. K., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Pibarot, P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1814052 · Cited by 4,847
Self-citationTranscatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients
Popma, J. J., Deeb, G. M., Yakubov, S. J., Mumtaz, M., Gada, H., O’Hair, D., Bajwa, T., Heiser, J. C., Merhi, W., Kleiman, N. S., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1816885 · Cited by 3,674
Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
Adams, D. H., Popma, J. J., Reardon, M. J., Yakubov, S. J., Coselli, J. S., Deeb, G. M., Gleason, T. G., Buchbinder, M., Hermiller, J., Kleiman, N. S., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1400590 · Cited by 2,902
Popma, J. J., Adams, D. H., Reardon, M. J., Yakubov, S. J., Kleiman, N. S., Heimansohn, D., Hermiller, J., Hughes, G. C., Harrison, J. K., Coselli, J., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.556 · Cited by 1,040
Thourani, V. H., Kodali, S., Makkar, R. R., Herrmann, H. C., Williams, M., Babaliaros, V., Smalling, R., Lim, S., Malaisrie, S. C., Kapadia, S., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30073-3 · Cited by 1,028
Self-citationTranscatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis
Thyregod, H. G. H., Steinbrüchel, D. A., Ihlemann, N., Nissen, H., Kjeldsen, B. J., Petursson, P., Chang, Y., Franzen, O. W., Engstrøm, T., Clemmensen, P., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.03.014 · Cited by 933
Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement
Kapadia, S. R., Kodali, S., Makkar, R., Mehran, R., Lazar, R. M., Zivadinov, R., Dwyer, M. G., Jilaihawi, H., Virmani, R., Anwaruddin, S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.023 · Cited by 509
Self-citationHaussig, S., Mangner, N., Dwyer, M. G., Lehmkuhl, L., Lücke, C., Woitek, F., Holzhey, D. M., Mohr, F. W., Gutberlet, M., Zivadinov, R., et al. (2016) · JAMA · doi:10.1001/jama.2016.10302 · Cited by 367
Self-citationRisk and Fate of Cerebral Embolism After Transfemoral Aortic Valve Implantation
Ghanem, A., Müller, A., Nähle, C. P., Kocurek, J., Werner, N., Hammerstingl, C., Schild, H. H., Schwab, J. O., Mellert, F., Fimmers, R., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.026 · Cited by 345
Histopathology of Embolic Debris Captured During Transcatheter Aortic Valve Replacement
Van Mieghem, N. M., Schipper, M. E. I., Ladich, E., Faqiri, E., van der Boon, R., Randjgari, A., Schultz, C., Moelker, A., van Geuns, R.-J., Otsuka, F., et al. (2013) · Circulation · doi:10.1161/circulationaha.112.001091 · Cited by 263
The Utility of Health States After Stroke: A Systematic Review of the Literature
Post, P. N., Stiggelbout, A. M., & Wakker, P. P. (2001) · Stroke · doi:10.1161/01.str.32.6.1425 · Cited by 244
Van Mieghem, N. M., van Gils, L., Ahmad, H., van Kesteren, F., van der Werf, H. W., Brueren, G., Storm, M., Lenzen, M., Daemen, J., van den Heuvel, A. F. M., et al. (2016) · EuroIntervention · doi:10.4244/eijv12i4a84 · Cited by 237
Association Between Transcatheter Aortic Valve Replacement and Early Postprocedural Stroke
Huded, C. P., Tuzcu, E. M., Krishnaswamy, A., Mick, S. L., Kleiman, N. S., Svensson, L. G., Carroll, J., Thourani, V. H., Kirtane, A. J., Manandhar, P., et al. (2019) · JAMA · doi:10.1001/jama.2019.7525 · Cited by 208
Self-citationKapadia, S., Agarwal, S., Miller, D. C., Webb, J. G., Mack, M., Ellis, S., Herrmann, H. C., Pichard, A. D., Tuzcu, E. M., Svensson, L. G., et al. (2016) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.115.002981 · Cited by 185
Self-citationProposed Standardized Neurological Endpoints for Cardiovascular Clinical Trials
Lansky, A. J., Messé, S. R., Brickman, A. M., Dwyer, M., van der Worp, H. B., Lazar, R. M., Pietras, C. G., Abrams, K. J., McFadden, E., Petersen, N. H., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.11.045 · Cited by 160
Self-citationSeeger, J., Gonska, B., Otto, M., Rottbauer, W., & Wöhrle, J. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.06.037 · Cited by 159
Self-citationVlastra, W., Jiménez‐Quevedo, P., Tchétché, D., Chandrasekhar, J., de Brito, F. S., Barbanti, M., Kornowski, R., Latib, A., D’Onofrio, A., Ribichini, F. L., et al. (2019) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.118.007546 · Cited by 152
Butala, N. M., Makkar, R., Secemsky, E. A., Gallup, D. S., Marquis‐Gravel, G., Kosinski, A. S., Vemulapalli, S., Valle, J. A., Bradley, S. M., Chakravarty, T., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.052874 · Cited by 106
Self-citationSeeger, J., Kapadia, S. R., Kodali, S., Linke, A. H.-P., Wöhrle, J., Haußig, S., Makkar, R., Mehran, R., Rottbauer, W., & Leon, M. B. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy847 · Cited by 94
Self-citationKapadia, S. R., Huded, C. P., Kodali, S., Svensson, L. G., Tuzcu, E. M., Baron, S. J., Cohen, D. J., Miller, D. C., Thourani, V. H., Herrmann, H. C., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.08.2172 · Cited by 84
Self-citationFanning, J. P., Walters, D., Platts, D. G., Eeles, E. M., Bellapart, J., & Fraser, J. F. (2014) · Circulation · doi:10.1161/circulationaha.113.004103 · Cited by 82
Reardon, M. J., Kleiman, N. S., Adams, D. H., Yakubov, S. J., Coselli, J. S., Deeb, G. M., O’Hair, D. P., Gleason, T. G., Lee, J. S., Hermiller, J. B., et al. (2016) · JAMA Cardiology · doi:10.1001/jamacardio.2016.2257 · Cited by 80
Ndunda, P. M., Vindhyal, M. R., Muutu, T. M., & Fanari, Z. (2019) · Cardiovascular revascularization medicine · doi:10.1016/j.carrev.2019.04.023 · Cited by 51
Transcatheter Aortic-Valve Implantation — At What Price?
Schaff, H. V. (2011) · New England Journal of Medicine · doi:10.1056/nejme1103978 · Cited by 40
Impact of Perioperative Stroke on Midterm Outcomes After Transcatheter Aortic Valve Replacement
Habertheuer, A., Gleason, T. G., Kilic, A., Schindler, J. T., Kliner, D., Bianco, V. J., Toma, C., Aranda-Michel, E. C., Kacin, A. J., & Sultan, I. S. (2020) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2020.01.074 · Cited by 28
Outcomes of stroke events during transcatheter aortic valve implantation
Almarzooq, Z., Kazi, D. S., Wang, Y., Chung, M., Tian, W., Strom, J. B., Baron, S. J., & Yeh, R. W. (2022) · EuroIntervention · doi:10.4244/eij-d-21-00951 · Cited by 28
Self-citationAppraisal of Health States Worse Than Death in Patients With Acute Stroke
Everett, E. A., Everett, W., Brier, M. R., & White, P. (2020) · Neurology Clinical Practice · doi:10.1212/cpj.0000000000000856 · Cited by 24
Cited by
Martin, S. S., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Barone Gibbs, B., Beaton, A. Z., Boehme, A. K., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001209 · Cited by 2,800
Transcatheter Aortic-Valve Replacement in Low-Risk Patients at Five Years
Mack, M. J., Leon, M. B., Thourani, V. H., Pibarot, P., Hahn, R. T., Genereux, P., Kodali, S. K., Kapadia, S. R., Cohen, D. J., Pocock, S. J., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2307447 · Cited by 635
Self-citation
Metadata
- Authors
- Kapadia, S. R., Makkar, R., Leon, M., Abdel-Wahab, M., Waggoner, T., Massberg, S., Rottbauer, W., Horr, S., Sondergaard, L., Karha, J., Gooley, R., Satler, L., Stoler, R. C., Messé, S. R., Baron, S. J., Seeger, J., Kodali, S., Krishnaswamy, A., Thourani, V. H., Harrington, K., Pocock, S., Modolo, R., Allocco, D. J., Meredith, I. T., & Linke, A.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2022-10-06
- Volume
- 387
- Issue
- 14
- Pages
- 1253-1263
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W4296143892
- Cited by
- 325
- References
- 30
- FWCI
- 38.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.