The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Self-Expanding or Balloon-Expandable TAVR in Patients with a Small Aortic Annulus
Abstract
Background Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). Methods We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm 2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). Results A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan–Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, −1.2 percentage points; 90% confidence interval [CI], −4.9 to 2.5; P<0.001 for noninferiority). The Kaplan–Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, −32.2 percentage points; 95% CI, −38.7 to −25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm 2 and 1.50 cm 2 ; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis–patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. Conclusions Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250 .)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationTranscatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients
Leon, M. B., Smith, C. R., Mack, M. J., Makkar, R. R., Svensson, L. G., Kodali, S. K., Thourani, V. H., Tuzcu, E. M., Miller, D. C., Herrmann, H. C., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1514616 · Cited by 5,053
Self-citationTranscatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
Mack, M. J., Leon, M. B., Thourani, V. H., Makkar, R., Kodali, S. K., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Pibarot, P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1814052 · Cited by 4,847
Proposed Modifications to the Duke Criteria for the Diagnosis of Infective Endocarditis
Li, J. S., Sexton, D. J., Mick, N., Nettles, R., Fowler, V. G., Ryan, T., Bashore, T., & Corey, G. R. (2000) · Clinical Infectious Diseases · doi:10.1086/313753 · Cited by 4,027
Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients
Popma, J. J., Deeb, G. M., Yakubov, S. J., Mumtaz, M., Gada, H., O’Hair, D., Bajwa, T., Heiser, J. C., Merhi, W., Kleiman, N. S., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1816885 · Cited by 3,674
Self-citationSurgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients
Reardon, M. J., Van Mieghem, N. M., Popma, J. J., Kleiman, N. S., Søndergaard, L., Mumtaz, M., Adams, D. H., Deeb, G. M., Maini, B., Gada, H., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1700456 · Cited by 3,009
Self-citationTranscatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
Adams, D. H., Popma, J. J., Reardon, M. J., Yakubov, S. J., Coselli, J. S., Deeb, G. M., Gleason, T. G., Buchbinder, M., Hermiller, J., Kleiman, N. S., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1400590 · Cited by 2,902
Self-citationGreen, C. P., Porter, C. B., Bresnahan, D. R., & Spertus, J. A. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00531-3 · Cited by 1,827
Updated Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.001 · Cited by 1,668
Self-citationGénéreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., Blackstone, E. H., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.02.038 · Cited by 1,313
Self-citationCapodanno, D., Petronio, A. S., Prendergast, B., Eltchaninoff, H., Vahanian, A., Modine, T., Lancellotti, P., Sondergaard, L., Ludman, P. F., Tamburino, C., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx303 · Cited by 535
Self-citationKodali, S., Thourani, V. H., White, J., Malaisrie, S. C., Lim, S., Greason, K. L., Williams, M., Guerrero, M., Eisenhauer, A. C., Kapadia, S., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw112 · Cited by 352
Self-citationAortic Bioprosthetic Valve Durability
Rodriguez-Gabella, T., Voisine, P., Puri, R., Pibarot, P., & Rodés-Cabau, J. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.715 · Cited by 351
Prosthesis–Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement
Herrmann, H. C., Daneshvar, S. A., Fonarow, G. C., Stebbins, A., Vemulapalli, S., Desai, N. D., Malenka, D. J., Thourani, V. H., Rymer, J., & Kosinski, A. S. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.09.001 · Cited by 336
Self-citationThiele, H., Kurz, T., Feistritzer, H.-J., Stachel, G., Hartung, P., Eitel, I., Marquetand, C., Nef, H., Doerr, O., Lauten, A., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa036 · Cited by 262
Self-citationLong-Term Durability of Transcatheter Aortic Valve Prostheses
Blackman, D. J., Saraf, S., MacCarthy, P. A., Myat, A., Anderson, S. G., Malkin, C. J., Cunnington, M. S., Somers, K., Brennan, P., Manoharan, G., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.078 · Cited by 261
Self-citation5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves
Abdel-Wahab, M., Landt, M., Neumann, F.-J., Massberg, S., Frerker, C., Kurz, T., Kaur, J., Toelg, R., Sachse, S., Jochheim, D., et al. (2020) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.12.026 · Cited by 239
Self-citationComprehensive Echocardiographic Assessment of Normal Transcatheter Valve Function
Hahn, R. T., Leipsic, J., Douglas, P. S., Jaber, W. A., Weissman, N. J., Pibarot, P., Blanke, P., & Oh, J. K. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.04.010 · Cited by 232
Tamburino, C., Bleiziffer, S., Thiele, H., Scholtz, S., Hildick-Smith, D., Cunnington, M., Wolf, A., Barbanti, M., Tchetchè, D., Garot, P., et al. (2020) · Circulation · doi:10.1161/circulationaha.120.051547 · Cited by 170
Self-citationAbdel-Wahab, M., Neumann, F.-J., Mehilli, J., Frerker, C., Richardt, D., Landt, M., Jose, J., Toelg, R., Kuck, K.-H., Massberg, S., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.06.026 · Cited by 162
Self-citationAortic Stenosis and Small Aortic Annulus: Clinical Challenges and Current Therapeutic Alternatives
Freitas-Ferraz, A. B., Tirado-Conte, G., Dagenais, F., Ruel, M., Al-Atassi, T., Dumont, E., Mohammadi, S., Bernier, M., Pibarot, P., & Rodés-Cabau, J. (2019) · Circulation · doi:10.1161/circulationaha.118.038408 · Cited by 159
Makkar, R., Cheng, W., Waksman, R., Satler, L. F., Chakravarty, T., Groh, M. A., Abernethy, W. B., Russo, M. J., Heimansohn, D. A., Hermiller, J. B., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31358-1 · Cited by 149
Abdelghani, M., Mankerious, N., Allali, A., Landt, M., Kaur, J., Sulimov, D. S., Merten, C., Sachse, S., Mehilli, J., Neumann, F., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.07.050 · Cited by 132
Self-citationSalaün, E., Mahjoub, H., Girerd, N., Dagenais, F., Voisine, P., Mohammadi, S., Yanagawa, B., Kalavrouziotis, D., Jüni, P., Verma, S., et al. (2018) · Circulation · doi:10.1161/circulationaha.118.035150 · Cited by 126
O’Hair, D. P., Yakubov, S. J., Grubb, K. J., Oh, J. K., Ito, S., Deeb, G. M., Mieghem, N. M. V., Adams, D. H., BAJWA, T. K., Kleiman, N. S., et al. (2022) · JAMA Cardiology · doi:10.1001/jamacardio.2022.4627 · Cited by 124
Self-citationImpact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
Sá, M. P., Jacquemyn, X., den Eynde, J. V., Tasoudis, P., Dokollari, A., Torregrossa, G., Sicouri, S., Clavel, M.-A. A., Pîbarot, P., & Ramlawi, B. (2022) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2022.07.013 · Cited by 122
Self-citationLeone, P. P., Regazzoli, D., Pagnesi, M., Sanz‐Sánchez, J., Chiarito, M., Cannata, F., Mieghem, N. M. V., Barbanti, M., Tamburino, C., Teles, R. C., et al. (2021) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2021.03.060 · Cited by 106
Bleiziffer, S., Eichinger, W. B., Hettich, I. M., Ruzicka, D., Wottke, M., Bauernschmitt, R., & Lange, R. (2007) · Heart · doi:10.1136/hrt.2007.116673 · Cited by 81
Self-citationBioprosthetic Aortic Valve Hemodynamics: Definitions, Outcomes, and Evidence Gaps
Herrmann, H. C., Pîbarot, P., Wu, C., Hahn, R. T., Tang, G. H. L., Abbas, A. E., Playford, D. A., Ruel, M., Jilaihawi, H., Sathananthan, J., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.06.001 · Cited by 74
Self-citationFeistritzer, H., Kurz, T., Stachel, G., Hartung, P., Lurz, P. C., Eitel, I., Marquetand, C., NEF, H. M., Doerr, O., Vigelius-Rauch, U., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.03.007 · Cited by 67
Self-citationRationale and design of the SMall Annuli Randomized To Evolut or SAPIEN Trial (SMART Trial)
Herrmann, H. C., Abdel‐Wahab, M., Attizzani, G. F., Batchelor, W., Bleiziffer, S., Verdoliva, S., Chang, Y., Gada, H., Gillam, L. D., Guerrero, M. E., et al. (2021) · American Heart Journal · doi:10.1016/j.ahj.2021.09.011 · Cited by 41
Self-citationPlayford, D. A., Stewart, S., Celermajer, D. S., Prior, D., Scalia, G. M., Marwick, T. H., Ilton, M. K., Codde, J., & Strange, G. A. (2020) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2020.04.024 · Cited by 39
Mosleh, W., Amer, M. R., Joshi, S., Mather, J. F., Gandhi, S., Iyer, V., Curtis, L., Kiernan, F. J., McMahon, S. R., Duvall, W. L., et al. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.08.014 · Cited by 34
Multiple Endpoints in Clinical Trials
Weissfeld, L. A. (2014) · Wiley StatsRef: Statistics Reference Online · doi:10.1002/9781118445112.stat04948 · Cited by 33
Kamioka, N., Arita, T., Hanyu, M., Hayashi, M., Watanabe, S., Miura, S., Isotani, A., Arai, Y., Kakumoto, S., Andò, K., et al. (2018) · International Heart Journal · doi:10.1536/ihj.17-656 · Cited by 28
Stanová, V., Rieu, R., Côté, N., Salaün, E., Rodés‐Cabau, J., & Pîbarot, P. (2021) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.29974 · Cited by 12
Cited by
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Metadata
- Authors
- Herrmann, H. C., Mehran, R., Blackman, D. J., Bailey, S., Möllmann, H., Abdel-Wahab, M., Ben Ali, W., Mahoney, P. D., Ruge, H., Wood, D. A., Bleiziffer, S., Ramlawi, B., Gada, H., Petronio, A. S., Resor, C. D., Merhi, W., Garcia del Blanco, B., Attizzani, G. F., Batchelor, W. B., Gillam, L. D., Guerrero, M., Rogers, T., Rovin, J. D., Szerlip, M., Whisenant, B., Deeb, G. M., Grubb, K. J., Padang, R., Fan, M. T., Althouse, A. D., & Tchétché, D.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2024-06-06
- Volume
- 390
- Issue
- 21
- Pages
- 1959-1971
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W4394062014
- Cited by
- 306
- References
- 36
- FWCI
- 82.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.