Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
We describe an ultrasensitive atomic magnetometer based on optically pumped potassium atoms operating in a spin-exchange relaxation free regime. We demonstrate magnetic field sensitivity of 160 aT/Hz1/2 in a gradiometer arrangement with a measurement volume of 0.45 cm3 and energy resolution per unit bandwidth of 44ℏ. As an example of an application enabled by such a magnetometer, we describe measurements of weak remnant rock magnetization as a function of temperature with a sensitivity on the order of 10−10 emu/cm3/Hz1/2 and temperatures up to 420°C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [33]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Self-citationA subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationSingle spin detection by magnetic resonance force microscopy
Rugar, D., Budakian, R., Mamin, H. J., & Chui, B. W. (2004) · Nature · doi:10.1038/nature02658 · Cited by 1,630
Spin-exchange optical pumping of noble-gas nuclei
Walker, T. G., & Happer, W. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.629 · Cited by 1,444
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationPaleomagnetic Principles and Practice
(2003) · Modern Approaches in Geophysics · doi:10.1007/0-306-48128-6 · Cited by 470
High-temperature weak ferromagnetism in a low-density free-electron gas
Young, D. P., Hall, D., Torelli, M. E., Fisk, Z., Sarrao, J. L., Thompson, J. D., Ott, H.-R., Oseroff, S. B., Goodrich, R. G., & Zysler, R. (1999) · Nature · doi:10.1038/17081 · Cited by 430
Ultrasensitive magnetic biosensor for homogeneous immunoassay
Chemla, Y. R., Grossman, H. L., Poon, Y., McDermott, R., Stevens, R., Alper, M. D., & Clarke, J. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.26.14268 · Cited by 421
Highly Sensitive and Easy-to-Use SQUID Sensors
Drung, D., Assmann, C., Beyer, J., Kirste, A., Peters, M., Ruede, F., & Schurig, T. (2007) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2007.897403 · Cited by 348
Cited by
Items 401–500 of 913
Li, R., Liu, Y., Li, J., Cao, Q., Huang, B., & Zhai, Y. (2024) · Optics & Laser Technology · doi:10.1016/j.optlastec.2024.111217 · Cited by 11
In-situ magnetic fields monitoring and compensation for zero-field atomic magnetometers
Yan, Y., Zhang, K., Liu, Z., Liu, Z., Li, X., Zhou, Y., & Lu, J. (2024) · Measurement · doi:10.1016/j.measurement.2024.115410 · Cited by 12
Huang, K., Mao, X., Zhang, Y., Wang, M., He, X., Ran, G., Hu, Q. C., & Lin, Z. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3470972 · Cited by 11
Accurate vector optically pumped magnetometer with microwave-driven Rabi frequency measurements
Kiehl, C., Menon, T. S., Knappe, S. A., Thiele, T., & Regal, C. A. (2024) · Optica · doi:10.1364/optica.542502 · Cited by 12
Ye, L., Pang, H., Liu, Y., Quan, J., Ma, L., Fan, W., & Quan, W. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3660442 · Cited by 11
Schneiderman, J. F., Ruffieux, S., Pfeiffer, C., & Riaz, B. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_78 · Cited by 12
Makarov, A. O., Brazhnikov, D. V., & Goncharov, A. (2023) · Journal of Experimental and Theoretical Physics Letters · doi:10.1134/s0021364023600684 · Cited by 54
Measurement of Relaxation Mechanism for the Spin-Exchange Relaxation-Free Magnetometer
Peng, J., Xu, A., Yin, Y., & Liu, B. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3334710 · Cited by 12
Suppressing the Decoherence of Alkali-Metal Spins at Low Magnetic Fields
Dikopoltsev, M., Berrebi, A., Levy, U., & Katz, O. (2025) · Physical Review Letters · doi:10.1103/physrevlett.134.143201 · Cited by 11
Wide-range and self-locking atomic magnetometer based on free spin precession
Miao, P.-X., Zheng, W., Yang, S., Wu, B., Cheng, B., Tu, J., Ke, H.-L., Yang, W., Wang, J., Jing-zhong, C., et al. (2019) · Journal of the Optical Society of America B · doi:10.1364/josab.36.000819 · Cited by 11
A calibration method for coil constants using an atomic spin self-sustaining vector magnetometer
Zhao, Q., Fan, B. L., Wang, S. G., & Wang, L. J. (2020) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2020.166977 · Cited by 11
Quieting an environmental magnetic field without shielding
Xiao, K., Wang, L., Guo, J., Zhu, M., Zhao, X., Sun, X., Ye, C., & Zhou, X. H. (2020) · Review of Scientific Instruments · doi:10.1063/5.0007464 · Cited by 11
Chen, Y., Zhao, L., Ma, Y., Yu, M., Wang, Y., Zhang, N., Wei, K., & Jiang, Z. (2022) · Biomedical Optics Express · doi:10.1364/boe.474862 · Cited by 11
Interaxial time-domain interference in single-beam SERF magnetometer
Lin, S., Yuan, Z., Tang, J., Lu, J., Cao, Q., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.112890 · Cited by 11
Shi, R., & Wang, Y. (2013) · Chinese Physics B · doi:10.1088/1674-1056/22/10/100703 · Cited by 12
Zhang, X., Jin, S., Qu, W., & Xiao, Y. (2021) · Applied Physics Letters · doi:10.1063/5.0054842 · Cited by 11
The Uncertainty Quantification for Parameters Optimization in SERF Atomic Magnetomer
Zhao, W., Li, Y., Wang, Y., Yan, Q., Song, Q., Wang, C., Kang, X., & Gao, X. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3116312 · Cited by 11
Shi, Y., Guo, X., Liu, X., Tang, J., Zhai, Y., & Feng, R. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3449978 · Cited by 10
Pulsed dual-axis alkali-metal–noble-gas comagnetometer
Wang, J., Lee, J., Loughlin, H. A., Hedges, M. P., & Romalis, M. V. (2025) · Physical Review A · doi:10.1103/physreva.111.053103 · Cited by 10
Self-citationMEMS Torsion Oscillator Magnetic Field Sensor
Yin, X., Jiao, Q., Yuan, L., & Liou, S. H. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2252153 · Cited by 10
Dual-beam room-temperature atomic magnetometer with high sensitivity and large dynamic range
Liu, B., Peng, J., Wang, H., Fang, C., Wang, J., Zhao, X., & Deng, L. (2022) · Applied Physics Express · doi:10.35848/1882-0786/acaa1c · Cited by 11
Single-beam three-axis SERF atomic magnetometer based on coordinate system rotation
Zhang, J., Chen, T., Chen, W., Ou, Z., Yue, H., & Liu, Y. (2024) · Optics Express · doi:10.1364/oe.524308 · Cited by 11
In Situ Measurement of High-Frequency Magnetic Field Produced by Electric Heaters in Atomic Sensors
Shao, Q., Jiang, L., Zhao, X. H., Liu, J., Fang, C., Zhu, J., Zou, Y., Lei, X., & Quan, W. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3427861 · Cited by 10
Interaction of vector light beams with atoms exposed to a time-dependent magnetic field
Ramakrishna, S., Schmidt, R. P., Peshkov, A. A., Franke‐Arnold, S., Surzhykov, A., & Fritzsche, S. (2024) · Physical Review A · doi:10.1103/physreva.110.043101 · Cited by 10
Femtotesla atomic magnetometer with counter-propagating optical sideband pumping
Peng, J., Xu, A., & Liu, B. (2024) · Optics Letters · doi:10.1364/ol.540032 · Cited by 10
Bandwidth compensation for ultra-high-sensitivity SERF magnetometers in magnetocardiac sensing
Jia, Y., Pei, H., Yang, Y., Jiang, L., Lu, J., Ning, X., Cui, Y., & Xiang, M. (2024) · Measurement · doi:10.1016/j.measurement.2024.116095 · Cited by 10
A dual closed-loop drive and control system of photoelastic modulator for atomic magnetometer
Quan, W., Wang, Q., & Zhai, Y. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aab6f4 · Cited by 10
Ma, Y., Chen, Y., Zhao, L., Yu, M., Wang, Y., Guo, J., Yang, P., Lin, Q., & Jiang, Z. (2022) · Measurement Science and Technology · doi:10.1088/1361-6501/ac72f9 · Cited by 11
Interleaved NQR detection using atomic magnetometers
Quiroz, D. R., Cooper, R. J., Foley, E. L., Kornack, T. W., Lee, G. J., & Sauer, K. L. (2022) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2022.107288 · Cited by 10
Liu, X., Yang, Y., Ding, M., Quan, W., Hu, Y., Li, Y., Jin, W., & Fang, J. (2019) · Journal of Lightwave Technology · doi:10.1109/jlt.2019.2892479 · Cited by 11
Multi-objective optimization of multilayer passive magnetic shield based on genetic algorithm
Li, J., Wang, Z., & Quan, W. (2019) · AIP Advances · doi:10.1063/1.5131250 · Cited by 11
Cavity-enhanced magnetometer with a spinor Bose–Einstein condensate
Gietka, K., Mivehvar, F., & Busch, T. (2021) · New Journal of Physics · doi:10.1088/1367-2630/abedff · Cited by 10
Ma, D., Fang, X., Lu, J., Wang, K., Sun, B., Gao, Y., Xu, X., & Han, B. (2022) · Materials · doi:10.3390/ma15238704 · Cited by 10
Hewatt, D. P., Ellmeier, M., Kiehl, C., Menon, T. S., Pollock, J. W., Regal, C. A., & Knappe, S. A. (2025) · Physical Review A · doi:10.1103/physreva.111.033106 · Cited by 9
Quantum sensing enhancement through a nuclear spin register in nitrogen-vacancy centers in diamond
Kenny, J., Zhou, F., He, R., Jelezko, F., Koh, T. S., & Gao, W. (2025) · Applied Physics Reviews · doi:10.1063/5.0235057 · Cited by 9
Heterodyne Detection of Low-Frequency Fields via Rydberg EIT with Phase Demodulation
Jin, S., Fan, X., Wang, X., Song, Y., & Sun, Y. (2025) · Chinese Physics Letters · doi:10.1088/0256-307x/42/11/110304 · Cited by 16
Sunlight-Driven Quantum Magnetometry
Zhu, Y., Xie, Y., Jing, K., Yu, Z., Yu, H., Zhang, W., Qin, X., Duan, C., Rong, X., & Du, J. (2022) · PRX Energy · doi:10.1103/prxenergy.1.033002 · Cited by 9
Coupling of Magnetic Field Noise in Multilayer Magnetic Shields for Atomic Magnetometer
Wang, Z., Zhang, M., Yang, K., Yu, T., Lv, B., Chen, Y., Zhang, N., Guo, J., Li, D., & Wang, X. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3353834 · Cited by 9
Unambiguous measurement in an unshielded microscale magnetometer with sensitivity below 1 pT / Hz
Taylor, H. A. M., Bounds, C. C., Tritt, A., & Turner, L. D. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.024047 · Cited by 11
Censorship of quantum resources in quantum networks
Pinske, J., & Mølmer, K. (2024) · Physical Review A · doi:10.1103/physreva.110.062404 · Cited by 9
Miniaturized Mechanical Antennas: Advances, Challenges, and Future Directions
Ren, H. (2024) · Advanced Physics Research · doi:10.1002/apxr.202400074 · Cited by 9
Magnetic-field-independent spin-exchange relaxation-free magnetometer
Dikopoltsev, M., Levy, U., & Katz, O. (2025) · Physical Review A · doi:10.1103/physreva.111.032602 · Cited by 9
Generation of polarization squeezed light with an optical parametric amplifier at 795 nm
Han, Y., Wen, X., Liu, J., He, J., & Wang, J. (2018) · Optics Communications · doi:10.1016/j.optcom.2018.01.038 · Cited by 9
Passive Magnetic Shielding of Stacked Joint-free Superconducting Annular Disks Made of REBCO Tapes
Peng, Y., Zeng, Z., Zhou, D., Zhao, W., Jia, Z., Guo, Y., Bai, C., Feng, F., Chen, Y., & Cai, C. (2021) · Journal of Superconductivity and Novel Magnetism · doi:10.1007/s10948-021-05894-y · Cited by 9
Reflected Atomic Magnetometer With Single Beam
Liu, X., Li, Y., Wu, X., Zhang, R., Chang, M., & Zhang, X. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3128944 · Cited by 9
A review of fiber‐coupled atomic magnetometer
Liu, X., Bi, W., Li, Y., Hu, Y., Chang, M., & Zhang, X. (2022) · Microwave and Optical Technology Letters · doi:10.1002/mop.33497 · Cited by 10
Liu, Z., Lu, J., Hu, Z., Li, X., Yan, Y., Zhan, D., & Li, J. (2024) · Chinese Optics Letters · doi:10.3788/col202422.051201 · Cited by 9
Conversion of thermal equilibrium states into superpositions of macroscopically distinct states
Tatsuta, M., & Shimizu, A. (2018) · Physical Review A · doi:10.1103/physreva.97.012124 · Cited by 11
Bai, M., Huang, Y., Zhang, G., Zheng, W., Lin, Q., & Hu, Z. (2019) · Optics Express · doi:10.1364/oe.27.029534 · Cited by 9
D’Agati, M. J., Sofronici, S., Huo, Y., Finkel, P., Bussmann, K., Mclaughlin, K. L., Wheeler, B., Jones, N. J., Mion, T., Staruch, M. L., et al. (2022) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2022.3226150 · Cited by 9
Measurement Sensitivity Improvement of All-Optical Atomic Spin Magnetometer by Suppressing Noises
Chen, X., Zhang, H., & Zou, S. (2016) · Sensors · doi:10.3390/s16060896 · Cited by 9
Enhancement of the Signal-to-Noise Ratio of an Atomic Magnetometer by 10 dB
Bao, G., Wu, S., Liu, S., Huang, W., Li, Z., Chen, L. Q., Yuan, C.-H., & Zhang, W. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.054075 · Cited by 9
Zero-field atomic magnetometer to extract longitudinal magnetic field
Wang, S., Lu, J., Zhang, K., Zhao, L., Qi, Y., & Fang, J. (2025) · Physical Review Research · doi:10.1103/yjc6-b26g · Cited by 8
Methods of Parametric Resonance Excitation in the Scheme of an Optical Magnetometric Sensor
Vershovskii, A. K., & Petrenko, M. V. (2021) · Technical Physics · doi:10.1134/s106378422105025x · Cited by 8
Fast measurement of magnetic gradient based on four-channel optically pumped atomic magnetometer
Zhang, Y., Tang, J., Li, C., Zhao, B., Li, L., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114591 · Cited by 9
Zhang, G., Zeng, H., Guo, R., Zhang, Q., Yu, W., & Lin, Q. (2023) · Optics Letters · doi:10.1364/ol.496076 · Cited by 9
Wang, H., Wang, S., Li, B., Qian, Y., & Lu, J. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.107070 · Cited by 8
Modeling and experimental studies of degaussing hysteresis in near-zero magnetic shielding systems
Wang, Z., Li, H., Yang, S., Han, B., Yu, S., & Wen, T. (2024) · Journal of Applied Physics · doi:10.1063/5.0193131 · Cited by 8
Beigh, N. T., Murali, N., Beigh, F. T., Betal, S., & Mallick, D. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3415388 · Cited by 8
Neural Network-Assisted Magnetic Moment Measurement Using an Atomic Magnetometer
Wang, Z., Lu, J., Liu, Z., Li, X., Sheng, J., & Li, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3544322 · Cited by 8
Trapped-ion based nanoscale quantum sensing
Yoo, J., Kim, H., Kim, H., Kim, Y. J., & Choi, T. (2025) · Nano Convergence · doi:10.1186/s40580-025-00479-0 · Cited by 12
Yan, B., Peng, Y., Zhang, Y., Zhang, Y., Zhang, H., Cao, Y., Sun, C. K., & Ding, M. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121262 · Cited by 8
Cavity-enhanced room-temperature high sensitivity optical Faraday magnetometry
Sun, H., Lei, Y., Fan, S., Zhang, Q., & Guo, H. M. (2016) · Physics Letters A · doi:10.1016/j.physleta.2016.10.045 · Cited by 8
Ultra-sensitive single-beam atom-optical magnetometer using weak measurement method
Chacko, V. F. T. J., Suna, R. R., Madhu, P. K., Viswanathan, N. K., & Rajalakshmi, G. (2019) · AIP Advances · doi:10.1063/1.5090581 · Cited by 9
Experimental optimization of atomic magnetometer in nuclear magnetic resonance gyroscope
Zhang, K., Luo, Z., Tang, F., Zhao, N., & Wang, Y. (2020) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ab6caf · Cited by 9
Atomic magnetometer with microfabricated vapor cells based on coherent population trapping*
Li, X., Shi, Y., Xue, H., Ruan, Y., & Feng, Y. (2020) · Chinese Physics B · doi:10.1088/1674-1056/abc2b9 · Cited by 8
Qin, J., Zhou, Y., & Wang, Y. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3137161 · Cited by 8
Zero field optically pumped magnetometer with independent dual-mode operation
Zhang, S., Lu, J., Zhou, Y., Lu, F., Yin, K., Zhan, D., Zhai, Y., & Ye, M. (2022) · Chinese Optics Letters · doi:10.3788/col202220.081202 · Cited by 9
Grating magneto-optical trap optimization and drift-mitigation based on Bayesian learning
Yu, Z., Chen, L., Duan, J., Yao, M., Tan, N., & Liu, X. (2024) · Applied Physics Letters · doi:10.1063/5.0187999 · Cited by 8
Effects of system parameters on a single-beam synthetic gradiometer with a dual-cell structure
Wu, Z., Zhang, J., Chen, W., Ou, Z., Yue, H., Cheng, C., & Liu, Y. (2024) · Optics Letters · doi:10.1364/ol.518697 · Cited by 8
Hu, Y., Hu, Z., Liu, X., Li, Y., Zhang, J., Yao, H., & Ding, M. (2017) · Applied Optics · doi:10.1364/ao.56.005927 · Cited by 9
Du, P., Li, J., Yang, S., Wang, X.-T., Zhuo, Y., Wang, F., & Wang, R. (2019) · Chinese Physics B · doi:10.1088/1674-1056/28/4/040702 · Cited by 8
Direct control of high magnetic fields for cold atom experiments based on NV centers
Hesse, A., Köster, K., Steiner, J. M., Michl, J., Vorobyov, V., Dasari, D. B. R., Wrachtrup, J., & Jendrzejewski, F. (2021) · New Journal of Physics · doi:10.1088/1367-2630/abe1e5 · Cited by 8
Comprehensive influence of modulated and bias magnetic fields on an atomic magnetometer
Yin, Y., Zhou, B., Yin, K., Tang, J., Ning, X., Han, B., & Fang, J. (2021) · Measurement Science and Technology · doi:10.1088/1361-6501/abdb79 · Cited by 11
Magnetic shielding property for cylinder with circular, square, and equilateral triangle holes*
Hao, S.-Y., Lou, X., Zhu, J., Chen, G., & Li, H. (2021) · Chinese Physics B · doi:10.1088/1674-1056/abeeee · Cited by 8
Ma, Y., Lu, J., Yang, K., Wang, Z., Wang, Y., Sun, B., Zhai, Y., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3207824 · Cited by 9
Static weak magnetic field measurements based on low-field nuclear magnetic resonance
Wang, X., Zhu, M., Xiao, K., Guo, J., & Wang, L. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.106580 · Cited by 8
Grewal, R. S., Pulido, M., Pati, G. S., & Tripathi, R. (2020) · Applied Physics Letters · doi:10.1063/5.0030696 · Cited by 8
All-optical self-oscillating 4He atomic mangnetometer with optical phase shift
Wang, H., Wu, T., Wang, H., Liu, Y., Mao, X., Peng, X., & Guo, H. (2020) · Optics Express · doi:10.1364/oe.390375 · Cited by 7
Shao, Q., Jiang, L., Zou, Y., Zhao, X. H., Zhu, J., Fang, C., Xiang, M., Lei, X., & Quan, W. (2024) · Measurement · doi:10.1016/j.measurement.2024.115734 · Cited by 7
Magnetic field compensation method of dual-beam SERF atomic magnetometer under probing-axis bias
Song, X., Wu, D., Long, T., Wu, Z., & Jia, L. (2025) · Measurement · doi:10.1016/j.measurement.2025.118102 · Cited by 8
Sun, Y., Zhou, Y., Wang, X., Bai, D., Wang, Y., & Zhou, Z. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3375422 · Cited by 7
Metasurface-based optical system for miniaturization of atomic magnetometers
Li, J., Zheng, J., Pan, S., Li, K., Yu, H., & Zheng, W. (2024) · Optics Express · doi:10.1364/oe.523114 · Cited by 7
Zheng, F., Li, C., Li, D., Xu, W., Ru, X., Cheng, H., Liu, Z., Na, S., Qin, L., Lyu, B., et al. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3435882 · Cited by 8
Effect of Optical Nonorthogonality on Dynamic Response in Dual-Beam Atomic Magnetometer
Xing, B., Li, S., Fang, X., Lu, H., & Ma, D. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3502819 · Cited by 7
High-Sensitivity, Microfabricated Quantum Magnetometers With an Intelligent Solar Heating System
Ma, Y., Chen, Y., Yu, M., Yanbin, W., Guo, J., Zhao, M., Yang, P., Lin, Q., & Zhao, L. (2025) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2024.3519377 · Cited by 10
A real-time signal space separation method for a 32-channel planar sensor array
Qiu, S., Tang, J., Wang, R., Zhao, F., Zhang, L., & Zhang, Z. (2025) · Measurement · doi:10.1016/j.measurement.2025.116759 · Cited by 8
Enhancement of Electron-Spin Polarization Using Magneto-Optical Synchronous Modulation
Fang, C., Jiang, L., Liu, J., Chen, Y., Zhu, J., Shao, Q., Zou, Y., & Quan, W. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3541674 · Cited by 8
Circular Dichroism Analysis and Ellipticity Measurement in SERF Atom Ensemble
Lv, H., Xing, B., Fang, X., Ma, D., & Lu, H. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3545202 · Cited by 8
Spin-amplification SERF atomic magnetometer based on direct feedback
Ma, Y., Yuan, Z., Lin, S., Zhai, Y., & Tang, J. (2025) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-025-00378-7 · Cited by 7
Fedosov, N., Medvedeva, D., Shevtsov, O., & Ossadtchi, A. E. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/aded35 · Cited by 8
Wang, F., Fang, X., Xing, B., Wang, Y., Li, J., Liu, J., Zhai, Y., & Ma, D. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3619263 · Cited by 8
Microscopic theory of a precessing ferromagnet for ultrasensitive magnetometry
Ni, X., Zou, Z., Lecamwasam, R., Vinante, A., Budker, D., Lam, P. K., Wang, T., & Gong, J. (2025) · Physical Review Research · doi:10.1103/1v1p-kpb2 · Cited by 11
Force‐Induced Remnant Magnetization Spectroscopy for Specific Magnetic Imaging of Molecules
Yao, L., & Xu, S. (2011) · Angewandte Chemie · doi:10.1002/ange.201007297 · Cited by 7
In-situ measurement and cancellation of the light-shift in fiber-coupled atomic magnetometers
Zhao, B., Tang, J., Li, L., Zhang, Y., Li, C., Liu, Y., & Zhai, Y. (2022) · Optics Express · doi:10.1364/oe.476113 · Cited by 7
Liu, X., Zhu, J., Wang, S., & Zhu, L. (2023) · Sensors International · doi:10.1016/j.sintl.2023.100233 · Cited by 7
Tunable magnetoresistance driven by electronic structure in Kagome semimetal Co1−xFexSn
Vijay, K., Chandra, L. S. S., Ali, K., Sagdeo, A., Tiwari, P., Chattopadhyay, M. K., Arya, A., & Banik, S. (2023) · Applied Physics Letters · doi:10.1063/5.0153865 · Cited by 7
Yong, 刘. L., Haobin, 林. L., Shaochun, 张. Z., Yang, 董. D., Xiangdong, 陈. C., & Fangwen, 孙. S. (2023) · Laser & Optoelectronics Progress · doi:10.3788/lop230704 · Cited by 7
Li, L., Tang, J., Zhao, B., & Zhai, Y. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.106728 · Cited by 7
Xing, B., Ma, N., Lv, H., & Lu, J. (2024) · Advanced Quantum Technologies · doi:10.1002/qute.202400226 · Cited by 7
Metadata
- Authors
- Dang, H. B., Maloof, A. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- ORCID
- Maloof, A. C.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2010-10-11
- Volume
- 97
- Issue
- 15
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2131775935
- Cited by
- 891
- References
- 24
- Citations by year
- 2026: 69 · 2025: 110 · 2024: 104 · 2023: 107 · 2022: 94 · 2021: 77 · 2020: 55 · 2019: 67 · 2018: 34 · 2017: 33 · 2016: 30 · 2015: 26 · 2014: 18 · 2013: 23 · 2012: 25
- FWCI
- 11.49
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Applied Physics Letters (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- atomic magnetometer, spin-exchange relaxation-free, magnetic field sensitivity, energy resolution, temperature dependence of magnetization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.