Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
We describe an ultrasensitive atomic magnetometer based on optically pumped potassium atoms operating in a spin-exchange relaxation free regime. We demonstrate magnetic field sensitivity of 160 aT/Hz1/2 in a gradiometer arrangement with a measurement volume of 0.45 cm3 and energy resolution per unit bandwidth of 44ℏ. As an example of an application enabled by such a magnetometer, we describe measurements of weak remnant rock magnetization as a function of temperature with a sensitivity on the order of 10−10 emu/cm3/Hz1/2 and temperatures up to 420°C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [33]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Self-citationA subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationSingle spin detection by magnetic resonance force microscopy
Rugar, D., Budakian, R., Mamin, H. J., & Chui, B. W. (2004) · Nature · doi:10.1038/nature02658 · Cited by 1,630
Spin-exchange optical pumping of noble-gas nuclei
Walker, T. G., & Happer, W. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.629 · Cited by 1,444
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationPaleomagnetic Principles and Practice
(2003) · Modern Approaches in Geophysics · doi:10.1007/0-306-48128-6 · Cited by 470
High-temperature weak ferromagnetism in a low-density free-electron gas
Young, D. P., Hall, D., Torelli, M. E., Fisk, Z., Sarrao, J. L., Thompson, J. D., Ott, H.-R., Oseroff, S. B., Goodrich, R. G., & Zysler, R. (1999) · Nature · doi:10.1038/17081 · Cited by 430
Ultrasensitive magnetic biosensor for homogeneous immunoassay
Chemla, Y. R., Grossman, H. L., Poon, Y., McDermott, R., Stevens, R., Alper, M. D., & Clarke, J. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.26.14268 · Cited by 421
Highly Sensitive and Easy-to-Use SQUID Sensors
Drung, D., Assmann, C., Beyer, J., Kirste, A., Peters, M., Ruede, F., & Schurig, T. (2007) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2007.897403 · Cited by 348
Cited by
Items 201–300 of 913
Detection and analysis of MEG signals in occipital region with double-channel OPM sensors
Zhang, X., Chen, C.-Q., Zhang, M., Ma, C., Zhang, Y., Wang, H., Guo, Q., Hu, T., Liu, Z., Chang, Y., et al. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108948 · Cited by 29
Integrated Polarization-Splitting Grating Coupler for Chip-Scale Atomic Magnetometer
Hu, J., Lu, J., Liang, Z., Liu, L., Wang, W., Zhou, P., & Ye, M. (2022) · Biosensors · doi:10.3390/bios12070529 · Cited by 29
A novel low-noise Mu-metal magnetic shield with winding shape
Ma, D., Lu, J., Fang, X., Dou, Y., Wang, K., Gao, Y., Li, S., & Han, B. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113884 · Cited by 29
A hybrid-systems approach to spin squeezing using a highly dissipative ancillary system
Dooley, S., Yukawa, E., Matsuzaki, Y., Knee, G. C., Munro, W. J., & Nemoto, K. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/5/053011 · Cited by 35
Cavity enhanced atomic magnetometry
Crepaz, H., Ley, L. Y., & Dumke, R. (2015) · Scientific Reports · doi:10.1038/srep15448 · Cited by 33
Bai, L., Wen, X., Yang, Y.-L., Zhang, L., He, J., Wang, Y., & Wang, J. (2021) · Journal of Optics · doi:10.1088/2040-8986/ac1b7c · Cited by 32
Zhang, S., Zhang, K., Zhou, Y., Ye, M., & Lu, J. (2022) · Optics Express · doi:10.1364/oe.464361 · Cited by 28
Suppression of Nonuniform Magnetic Fields in Magnetic Shielding System for SERF Co-Magnetometer
Fu, Y., Wang, Z., Li, X., Fan, W., Ruan, J., & Pang, H. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3178738 · Cited by 28
Nondestructive in-line sub-picomolar detection of magnetic nanoparticles in flowing complex fluids
Bougas, L., Langenegger, L. D., Mora, C. A., Zeltner, M., Stark, W. J., Wickenbrock, A., Blanchard, J. W., & Budker, D. (2018) · Scientific Reports · doi:10.1038/s41598-018-21802-2 · Cited by 32
Voigt-effect-based three-dimensional vector magnetometer
Pyragius, T., Florez, H. M., & Fernholz, T. (2019) · Physical Review A · doi:10.1103/physreva.100.023416 · Cited by 30
Design and Analysis of a High-Sensitivity Atomic Magnetic Gradiometer With Adjustable Baseline
Zhang, Y., Tang, J., Xu, X., Wang, Z., & Zhai, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3544375 · Cited by 27
PT -symmetry-breaking-enhanced cavity optomechanical magnetometry
Zhang, Z., Wang, Y.-P., & Wang, X. (2020) · Physical Review A · doi:10.1103/physreva.102.023512 · Cited by 27
Fu, Y., Sun, J., Ruan, J., & Quan, W. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113487 · Cited by 27
Ouyang, K., Shi, Y., Lei, M., & Shi, M. (2023) · Applied Physics Letters · doi:10.1063/5.0186065 · Cited by 27
Scholtes, T., Schultze, V., IJsselsteijn, R. P. J., Woetzel, S., & Meyer, H. (2012) · Optics Express · doi:10.1364/oe.20.029217 · Cited by 28
Miniature quad-channel spin-exchange relaxation-free magnetometer for magnetoencephalography
Li, J., Du, P., Fu, J., Wang, X.-T., Zhou, Q., & Wang, R. (2019) · Chinese Physics B · doi:10.1088/1674-1056/28/4/040703 · Cited by 27
Synchronous measurement of inertial rotation and magnetic field using a K−Rb−Ne21 comagnetometer
Quan, W., Wei, K., Zhao, T., Li, H., & Zhai, Y. (2019) · Physical Review A · doi:10.1103/physreva.100.012118 · Cited by 27
Vector magnetocardiography using compact optically-pumped magnetometers
Su, S., Xu, Z., He, X., Zhang, G., Wu, H., Gao, Y., Ma, Y., Yin, C., Ruan, Y., Li, K., et al. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e29092 · Cited by 26
Free-induction-decay 4 He magnetometer using a multipass cell
Yi, K., Liu, Y., Wang, B., Xiao, W., Sheng, D., Peng, X., & Guo, H. M. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.014084 · Cited by 27
Yang, K., Lu, J., Ding, M., Zhao, J., Ma, D., Li, Y., Xing, B., Han, B., & Fang, J. (2019) · IEEE Access · doi:10.1109/access.2019.2935034 · Cited by 26
Geographic True Navigation Based on Real-Time Measurements of Geomagnetic Fields
Qi, X., Xu, K., Xu, Z., Li, H., & Ran, L. (2023) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2023.3312164 · Cited by 26
Shao, Q., Lei, X., Jiang, L., Zhu, J., Zou, Y., Fang, C., Liang, X., Song, X., & Quan, W. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3314810 · Cited by 26
Suppression of spin-exchange relaxation in tilted magnetic fields within the geophysical range
Scholtes, T., Pustelny, S., Fritzsche, S., Schultze, V., Stolz, R., & Meyer, H. (2016) · Physical Review A · doi:10.1103/physreva.94.013403 · Cited by 27
A method for calibrating coil constants by using an atomic spin co-magnetometer
Zhang, H., Zou, S., & Chen, X. (2016) · The European Physical Journal D · doi:10.1140/epjd/e2016-70091-y · Cited by 28
Ji, W., Fu, C., & Gao, H. (2017) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.95.075014 · Cited by 27
Experimental realization of open magnetic shielding
Gu, C., Chen, S., Pang, T. C. I., & Qu, T. (2017) · Applied Physics Letters · doi:10.1063/1.4983490 · Cited by 26
Zhang, K., Guo, J., Chen, L. Q., Yuan, C.-H., Ou, Z. Y., & Zhang, W. (2014) · Physical Review A · doi:10.1103/physreva.90.033823 · Cited by 29
Mode analysis of spin field of thermal atomic ensembles
Wang, W., Xia, M., Quan, W., & Wei, K. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad4912 · Cited by 25
New Classes of Magnetic Noise Self-Compensation Effects in Atomic Comagnetometer
Qin, Y., Shao, Z., Hong, T., Wang, Y., Jiang, M., & Peng, X. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.023202 · Cited by 25
Quantum metrology with generalized cat states
Tatsuta, M., Matsuzaki, Y., & Shimizu, A. (2019) · Physical Review A · doi:10.1103/physreva.100.032318 · Cited by 26
Zhang, G., Zeng, H., Tan, G., & Lin, Q. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3156814 · Cited by 26
Optical pumping enhancement of a free-induction-decay magnetometer
Hunter, D., Mrozowski, M. S., McWilliam, A., Ingleby, S. J., Dyer, T., Griffin, P. F., & Riis, E. (2023) · Journal of the Optical Society of America B · doi:10.1364/josab.501086 · Cited by 27
Transient dynamics of atomic spin in the spin-exchange-relaxation-free regime
Tang, J., Yin, Y., Zhai, Y., Zhou, B., Han, B., Yang, H., & Liu, G. (2021) · Optics Express · doi:10.1364/oe.418776 · Cited by 27
Searches for exotic spin-dependent interactions with spin sensors
Jiang, M., Su, H., Chen, Y., Jiao, M., Huang, Y., Wang, Y., Rong, X., Peng, X., & Du, J. (2024) · Reports on Progress in Physics · doi:10.1088/1361-6633/ad99e6 · Cited by 27
Spin Exchange Relaxation Free (SERF) Magnetometers
Savukov, I. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-34070-8_15 · Cited by 35
Towards the Non-Zero Field Cesium Magnetic Sensor Array for Magnetoencephalography
Petrenko, M. V., Dmitriev, S. P., Pazgalev, A. S., Ossadtchi, A. E., & Vershovskii, A. K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3089455 · Cited by 26
Spin-exchange relaxation-free magnetic gradiometer with dual-beam and closed-loop Faraday modulation
Fang, J., Wan, S., Qin, J., Zhang, C., & Quan, W. (2014) · Journal of the Optical Society of America B · doi:10.1364/josab.31.000512 · Cited by 24
Optically pumped vector magnetometer using a strong bias magnetic field
Schönau, T., Scholtes, T., Wittkämper, F., Sekels, A., Hiebel, S., Oelsner, G., & Stolz, R. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.024006 · Cited by 27
Adaptive cold-atom magnetometry mitigating the trade-off between sensitivity and dynamic range
Ma, Z., Han, C., Tan, Z., He, H.-N., Shi, S., Kang, X., Wu, J., Huang, J., Lü, B., & Lee, C. (2025) · Science Advances · doi:10.1126/sciadv.adt3938 · Cited by 23
Ji, Y., Shang, J., Gan, Q., Wu, L., & Wong, C. (2018) · IEEE Transactions on Components Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2018.2868313 · Cited by 23
Triaxial Vector Operation in Near-Zero Field of Atomic Magnetometer With Femtotesla Sensitivity
Lu, F., Lu, J., Li, B., Yan, Y., Zhang, S., Yin, K., Ye, M., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3162282 · Cited by 27
Li, L., Tang, J., Zhao, B., Li, C., Zhou, B., & Zhai, Y. (2022) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac9cea · Cited by 23
A novel oven structure for improving temperature uniformity of vapor cell in atomic sensors
Gao, Y., Ma, D., Jiang, S., Ma, Y., Li, S., Wang, K., & Xu, X. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.106339 · Cited by 26
Yu, A., Tian, J., Zhang, Y., & Xia, L. (2023) · Optics & Laser Technology · doi:10.1016/j.optlastec.2023.110349 · Cited by 23
Magnetic tensor gradiometry using Ramsey interferometry of spinor condensates
Wood, A. A., Bennie, L. M., Duong, A., Jasperse, M., Turner, L. D., & Anderson, R. P. (2015) · Physical Review A · doi:10.1103/physreva.92.053604 · Cited by 23
The development of a multichannel atomic magnetometer array for fetal magnetocardiography
Wylie, R. B. (2012) · Cited by 33
Magnetic noise calculation of mu-metal shields at extremely low frequencies for atomic devices
Ma, D., Ding, M., Lu, J., Zhao, J., Yang, K., Fang, X., Wang, K., Zhang, N., & Han, B. (2020) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/abbe4b · Cited by 23
Search for plant biomagnetism with a sensitive atomic magnetometer
Corsini, E., Acosta, V., Baddour, N., Higbie, J., Lester, B., Licht, P., Patton, B., Prouty, M., & Budker, D. (2011) · Journal of Applied Physics · doi:10.1063/1.3560920 · Cited by 23
Sensitive imaging of electromagnetic fields with paramagnetic polar molecules
Alyabyshev, S., Lemeshko, M., & Krems, R. V. (2012) · Physical Review A · doi:10.1103/physreva.86.013409 · Cited by 24
Femtotesla 4 He magnetometer with a multipass cell
Liu, Y., Peng, X., Wang, H., Wang, B., Yi, K., Sheng, D., & Guo, H. M. (2022) · Optics Letters · doi:10.1364/ol.471557 · Cited by 24
Experimental studies on the performance of magnetic shields under different magnetization conditions
Yang, J., Zhang, X., Shi, M., Yuan, S., Zhang, L., Wang, L., & Han, B. (2023) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/acc412 · Cited by 22
Automatic co-registration of OPM-MEG and MRI using a 3D laser scanner
Gao, Z., Cao, F., An, N., & Ning, X. (2023) · Measurement · doi:10.1016/j.measurement.2023.113729 · Cited by 22
Tang, J., Qiu, S., Zhang, L., Sun, J., & Zhou, X. (2023) · Measurement · doi:10.1016/j.measurement.2023.113904 · Cited by 23
Intrinsic relaxation rates of polarized Cs vapor in miniaturized cells
Scholtes, T., Woetzel, S., IJsselsteijn, R. P. J., Schultze, V., & Meyer, H. (2014) · Applied Physics B · doi:10.1007/s00340-014-5824-z · Cited by 25
A dual-axis, high-sensitivity atomic magnetometer
Li, R., Quan, W., Fan, W., Li, X., Wang, Z., Zhai, Y., & Fang, J. (2017) · Chinese Physics B · doi:10.1088/1674-1056/26/12/120702 · Cited by 22
Suppression Method of AC-Stark Shift in SERF Atomic Magnetometer
Li, Y., Ding, M., Liu, X., Cai, H., Zhao, J., & Fang, J. (2018) · IEEE photonics journal · doi:10.1109/jphot.2018.2872026 · Cited by 27
Elliptically polarized laser-pumped Mx magnetometer towards applications at room temperature
Su, S., Zhang, G., Bi, X., He, X., Zheng, W., & Lin, Q. (2019) · Optics Express · doi:10.1364/oe.27.033027 · Cited by 22
Effect of gaps on magnetic noise of cylindrical ferrite shield
Lu, J., Sun, C., Ma, D., Yang, K., Zhao, J., Han, B., Quan, W., Zhang, N., & Ding, M. (2021) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/abf169 · Cited by 22
Fang, X., Ma, D., Sun, B., Xu, X., Quan, W., Xiao, Z., & Zhai, Y. (2022) · Materials · doi:10.3390/ma15196680 · Cited by 21
Li, L., Tang, J., Zhao, B., Cao, L., Zhang, Y., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.113161 · Cited by 22
Suppression of Magnetic Noise and Field in Cubic Low-Noise Ferrite Magnetic Shields
Sun, B., Ma, D., Fang, X., Xue, Y., Lu, J., Chen, H., Zhang, M., Wei, H., Han, B., & Zhai, Y. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3385809 · Cited by 25
Ji, D., Xiao, X., Wu, J., He, X., Zhang, G., Guo, R., Liu, M., Xu, M., Lin, Q., Jung, T., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad44d8 · Cited by 21
Tunable current circulation in triangular quantum-dot metastructures
Lai, C.-Y., Ventra, M. D., Scheibner, M., & Chien, C.-C. (2018) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/123/47002 · Cited by 21
Alghannam, F. S., & Hemmer, P. (2019) · Scientific Reports · doi:10.1038/s41598-019-42323-6 · Cited by 24
Electromagnetic fields induced by an electric charge near a Weyl semimetal
Martín-Ruiz, A., Cambiaso, M., & Urrutia, L. F. (2019) · Physical review. B./Physical review. B · doi:10.1103/physrevb.99.155142 · Cited by 26
Signal-enhanced real-time magnetic resonance of enzymatic reactions at millitesla fields
Korchak, S. E., Jagtap, A. P., & Glöggler, S. (2020) · Chemical Science · doi:10.1039/d0sc04884d · Cited by 21
Quantitative analysis of magnetic cobalt particles with an optically pumped atomic magnetometer
Bi, X., Ruan, L., Liu, Z., Li, K., Ruan, Y., Zheng, W., & Lin, Q. (2021) · Applied Physics Letters · doi:10.1063/5.0039565 · Cited by 21
In Situ Measurement of Nonorthogonal Angles of a Three-Axis Vector Optically Pumped Magnetometer
Li, S., Lu, J., Ma, D., Wang, K., Gao, Y., Sun, C., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3144737 · Cited by 21
Quantum Sensing with Spin Defects Beyond Diamond
Roberts, H. C., Abudayyeh, H. A., Li, X., & Li, X. (2025) · ACS Nano · doi:10.1021/acsnano.5c00802 · Cited by 29
Quantum sensing of the electron electric dipole moment using ultracold entangled Fr atoms
Aoki, T., Sreekantham, R., Sahoo, B. K., Arora, B., Kastberg, A., Sato, T., Ikeda, H., Okamoto, N., Torii, Y., Hayamizu, T., et al. (2021) · Quantum Science and Technology · doi:10.1088/2058-9565/ac1b6a · Cited by 22
Drug Monitoring by Optically Pumped Atomic Magnetometer
Ruan, Y., He, X., Ruan, L., Liu, F., Zhang, Z., Weng, J., Yan, Q., Zhang, G., Li, K., Zheng, W., et al. (2022) · IEEE photonics journal · doi:10.1109/jphot.2022.3184050 · Cited by 20
Ma, N., Duan, L., Ma, D., Lu, J., Xing, B., Li, J., & Han, B. (2022) · Optics Express · doi:10.1364/oe.474777 · Cited by 20
Triaxial closed-loop measurement based on a single-beam zero-field optically pumped magnetometer
Wang, K., Zhang, K., Zhou, B., Lu, F., Zhang, S., Yan, Y., Wang, W., & Lu, J. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.1059487 · Cited by 20
Hands-On Quantum Sensing with NV− Centers in Diamonds
Toural, J. L. S., Marzoa, V., Gavito, R. B., Pau, J. L., & Granados, D. (2023) · C – Journal of Carbon Research · doi:10.3390/c9010016 · Cited by 20
Signal-enhanced spin-exchange relaxation-free atomic magnetometer
Li, C., Tang, J., Zhang, Y., Yuan, Z., Li, J., Zhai, Y., & Liu, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114247 · Cited by 22
Suppression of modulation-magnetic-fields crosstalk for single-beam optically-pumped magnetometers
Suo, Y., Song, X., Jiang, L., Jia, L., Long, T., & Wu, Z. (2023) · Measurement · doi:10.1016/j.measurement.2023.113059 · Cited by 20
Optimal Design of Self-Shielded Biplanar Coil Assembly With Miniaturized Structure
Tang, S., Lu, J., Sun, B., Wang, S., Wang, K., Zhang, X., & Li, B. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3323002 · Cited by 25
Quan, W., Wei, K., & Li, H. (2017) · Optics Express · doi:10.1364/oe.25.008470 · Cited by 20
Zhao, J., Liu, G., Lu, J., Yang, K., Ma, D., Xing, B., Han, B., & Ding, M. (2019) · IEEE Access · doi:10.1109/access.2019.2954103 · Cited by 22
Rapid Online Solid-State Battery Diagnostics with Optically Pumped Magnetometers
Hu, Y., Iwata, G. Z., Bougas, L., Blanchard, J. W., Wickenbrock, A., Jakob, G., Schwarz, S., Schwarzinger, C., Jerschow, A., & Budker, D. (2020) · Applied Sciences · doi:10.3390/app10217864 · Cited by 20
Microfabricated Optically-Pumped Magnetometers
Jiménez-Martínez, R., & Knappe, S. A. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-34070-8_17 · Cited by 28
Low Noise, Strain Modulated, Multiferroic Magnetic Field Sensor Systems
Huo, Y., Sofronici, S., Wang, X., D’Agati, M. J., Finkel, P., Bussmann, K., Mion, T., Staruch, M. L., Jones, N. J., Wheeler, B., et al. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3279229 · Cited by 20
Gusarov, A., Levron, D., Baranga, A. B.-A., Paperno, E., & Shuker, R. (2011) · Journal of Applied Physics · doi:10.1063/1.3536673 · Cited by 20
In Situ Compensation of Triaxial Magnetic Field Gradient for Atomic Magnetometers
Yang, K., Lu, J., Ma, Y., Wang, Z., Sun, B., Wang, Y., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3162607 · Cited by 29
Xu, X., Liu, W., Zhao, Z., & Ye, F. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3395694 · Cited by 19
Subpicotesla Optomechanical Magnetometry
Xu, A., Li, Y., Li, X., Liu, B., & Liu, Y. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.153601 · Cited by 19
On-chip integrated high-performance bi-planar coils for chip-scale atomic magnetometers
Wang, A., Hu, G., Zhou, P., Wang, Y., Yang, J., Liang, Z., Hu, J., Liu, L., & Ye, M. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116260 · Cited by 19
Spatially-selective in situ magnetometry of ultracold atomic clouds
Elíasson, O., Heck, R., Laustsen, J. S., Napolitano, M., Müller, R., Bason, M. G., Arlt, J. J., & Sherson, J. F. (2019) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/ab0bd6 · Cited by 22
Repumping atomic media for an enhanced sensitivity atomic magnetometer
Li, R., Perrella, C., & Luiten, A. N. (2022) · Optics Express · doi:10.1364/oe.467513 · Cited by 19
Four-channel optically pumped magnetometer for a magnetoencephalography sensor array
Iivanainen, J., Carter, T. R., Dhombridge, J. E., Read, T. S., Campbell, K., Abate, Q., Ridley, D. M., Borna, A., & Schwindt, P. D. D. (2024) · Optics Express · doi:10.1364/oe.517961 · Cited by 18
“[1]) operating in the spin-exchange-relaxation-free (SERF) regime [2] are among the most sensitive magnetic-field sensors, achieving sensitivity levels as low as 0.16 fT/rt-Hz [3] and 0.54 fT/rt-Hz [4].”
InfluentialZhu, R., Zhang, Y., Du, P., Xuan, Y., Yang, F., Zhou, Y., Zhang, K., Li, X., Sun, S., Cheng, T., et al. (2025) · Measurement · doi:10.1016/j.measurement.2025.117099 · Cited by 18
Wei, Y., Liu, S., Liu, F., Fan, W., Zhai, Y., & Quan, W. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114467 · Cited by 19
Sun, B., Ma, D., Bai, G., Zeng, M., Cheng, T., Ma, Y., Xu, X., Quan, W., Han, B., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.113419 · Cited by 19
Portable single-beam cesium zero-field magnetometer for magnetocardiography
Dawson, R., O’Dwyer, C., Mrozowski, M. S., Irwin, E., McGilligan, J. P., Burt, D. P., Hunter, D., Ingleby, S. J., Rea, M., Holmes, N., et al. (2023) · Journal of Optical Microsystems · doi:10.1117/1.jom.3.4.044501 · Cited by 20
Eavesdropping on Tinnitus Using MEG: Lessons Learned and Future Perspectives
Reisinger, L., Demarchi, G., & Weisz, N. (2023) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-023-00916-z · Cited by 19
Hu, J., Liang, Z., Zhou, P., Liu, L., Hu, G., Du, P., & Ye, M. (2024) · Optics Letters · doi:10.1364/ol.527932 · Cited by 18
Femtotesla Spin-Exchange Relaxation-Free Atomic Magnetometer With a Multipass Cell
Qi, Y., Li, B., Wang, S., Xu, N., Qian, Y., & Lu, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3460884 · Cited by 19
Simultaneous measurement of magnetic field and inertia based on hybrid optical pumping
Quan, W., Li, Y., & Liu, B. (2015) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/110/60002 · Cited by 18
Wu, L., Shang, J., Ji, Y., Gan, Q., & Wong, C. (2017) · IEEE Transactions on Components Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2017.2773509 · Cited by 19
Jiang, L., Duan, L., Liu, J., Liang, Y., Quan, W., & Fang, J. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3033933 · Cited by 20
Metadata
- Authors
- Dang, H. B., Maloof, A. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- ORCID
- Maloof, A. C.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2010-10-11
- Volume
- 97
- Issue
- 15
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2131775935
- Cited by
- 891
- References
- 24
- Citations by year
- 2026: 69 · 2025: 110 · 2024: 104 · 2023: 107 · 2022: 94 · 2021: 77 · 2020: 55 · 2019: 67 · 2018: 34 · 2017: 33 · 2016: 30 · 2015: 26 · 2014: 18 · 2013: 23 · 2012: 25
- FWCI
- 11.49
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Applied Physics Letters (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- atomic magnetometer, spin-exchange relaxation-free, magnetic field sensitivity, energy resolution, temperature dependence of magnetization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.