CoChat

Ta and Au(Pd) alloy metal film transducers for time-domain thermoreflectance at high pressures

Hsieh, Wen-Pin, Cahill, David G. · 2011 · Journal of Applied Physics
Cited by 23

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

We studied the pressure dependence of the thermoreflectance and piezo-optical coefficients of metal film transducers—Al, Ta, and Au(Pd) alloy (≈5 at. % Pd)—at a laser wavelength, 785 nm, commonly used in time-domain thermoreflectance (TDTR) and picosecond acoustics experiments. Al has exceptionally high thermoreflectance at ambient pressure, dR/dT ≈ 1.3 × 10−4 K−1, but its applicability at high temperatures is limited by the low melting temperature. The thermoreflectance of Al also has an undesirable zero-crossing near 6 GPa. The thermoreflectance values of Ta and Au(Pd) are comparable to that of Al at ambient conditions but independent of pressure in the pressure range 0 < P < 10 GPa. Ta and Au(Pd) thin film transducers also show strong picosecond acoustic echoes at all pressures in this range. We conclude that Ta and Au(Pd) metal film transducers can replace Al in TDTR experiments and thereby facilitate the extension of TDTR methods to high pressures and temperatures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.3592882

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Hsieh, W.-P., & Cahill, D. G.
Venue
Journal of Applied Physics
Published
2011-06-01
Volume
109
Issue
11
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2093742784
Cited by
23
References
7
FWCI
1.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.