The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Adsorption-induced surface stress and its effects on resonance frequency of microcantilevers
Abstract
It is well known that bimetallic microcantilevers can exhibit static deflection as a result of thermal effects, including exothermic adsorption of chemicals on their surfaces. It is shown here that the resonance frequency of a cantilever can change due to a combination of mass loading and change of spring constant resulting from adsorption of chemicals on the surface. Cantilevers also undergo static bending that is induced by differential surface stress. The magnitude of these effects depends upon the chemical properties of the surface and upon the amount of material adsorbed. Hence cantilever deflection as well as resonance frequency change can be used as the basis for development of novel chemical sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Hass, G., & Gerstenberg, D. (1964) · Journal of The Electrochemical Society · doi:10.1149/1.2426128 · Cited by 1,754
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Calculated elastic constants for stress problems associated with semiconductor devices
Brantley, W. A. (1973) · Journal of Applied Physics · doi:10.1063/1.1661935 · Cited by 1,203
Observation of a chemical reaction using a micromechanical sensor
Gimzewski, J. K., Gerber, C., Meyer, E., & Schlittler, R. R. (1994) · Chemical Physics Letters · doi:10.1016/0009-2614(93)e1419-h · Cited by 469
Thermal and ambient-induced deflections of scanning force microscope cantilevers
Thundat, T., Warmack, R. J., Chen, G. Y., & Allison, D. P. (1994) · Applied Physics Letters · doi:10.1063/1.111407 · Cited by 419
Self-citationCalculation of stress in electrodeposits from the curvature of a plated strip
Brenner, A., & Senderoff, S. (1949) · Journal of Research of the National Bureau of Standards · doi:10.6028/jres.042.009 · Cited by 412
Force microscopy with a bidirectional capacitance sensor
Neubauer, G., Cohen, S. R., McClelland, G. M., Horne, D., & Mate, C. M. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141354 · Cited by 188
Friction effects in the deflection of atomic force microscope cantilevers
Warmack, R. J. B., Zheng, X.-J., Thundat, T. G., & Allison, D. P. (1994) · Review of Scientific Instruments · doi:10.1063/1.1145144 · Cited by 108
Self-citation
Cited by
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Micromechanical cantilever-based biosensors
Raiteri, R., Grattarola, M., Butt, H.-J., & Skládal, P. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00856-5 · Cited by 734
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Smart single-chip gas sensor microsystem
Hagleitner, C., Hierlemann, A., Lange, D., Kummer, A., Kerness, N., Brand, O., & Baltes, H. (2001) · Nature · doi:10.1038/35104535 · Cited by 619
Cantilever-like micromechanical sensors
Boisen, A., Dohn, S., Keller, S. S., Schmid, S., & Tenje, M. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/3/036101 · Cited by 566
Single virus particle mass detection using microresonators with nanoscale thickness
Gupta, A., Akin, D., & Bashir, R. (2004) · Applied Physics Letters · doi:10.1063/1.1667011 · Cited by 543
Ziegler, C. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2694-y · Cited by 414
Surface-Stress Induced Macroscopic Bending of Nanoporous Gold Cantilevers
Kramer, D., Viswanath, R. N., & Weissmüller, J. (2004) · Nano Letters · doi:10.1021/nl049927d · Cited by 409
Biosensors based on nanomechanical systems
Tamayo, J., Kosaka, P. M., Ruz, J. J., San Paulo, Á., & Calleja, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35293a · Cited by 391
Nanosensors for trace explosive detection
Senesac, L., & Thundat, T. G. (2008) · Materials Today · doi:10.1016/s1369-7021(08)70017-8 · Cited by 368
Self-citationMicrocantilevers: Sensing Chemical Interactions via Mechanical Motion
Goeders, K. M., Colton, J. S., & Bottomley, L. A. (2008) · Chemical Reviews · doi:10.1021/cr0681041 · Cited by 351
Surface stress effect in mechanics of nanostructured materials
Wang, J., Huang, Z., Duan, H., Yu, S., Feng, X., Wang, G., Zhang, W., & Wang, T. (2011) · Acta Mechanica Solida Sinica · doi:10.1016/s0894-9166(11)60009-8 · Cited by 349
Biosensing using dynamic-mode cantilever sensors: A review
Johnson, B. N., & Mutharasan, R. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.054 · Cited by 314
Adsorption-induced deformation of nanoporous materials—A review
Gor, G. Y., Huber, P., & Bernstein, N. (2017) · Applied Physics Reviews · doi:10.1063/1.4975001 · Cited by 273
Fritz, J. (2008) · The Analyst · doi:10.1039/b718174d · Cited by 254
Metadata
- Authors
- Chen, G. Y., Thundat, T., Wachter, E. A., & Warmack, R. J.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1995-04-15
- Volume
- 77
- Issue
- 8
- Pages
- 3618-3622
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W1968514543
- Cited by
- 539
- References
- 10
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.