CoChat

High-speed long-wave infrared ultra-thin photodetectors

Open access

The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.

Abstract

The primary challenge for long-wavelength infrared (λ = 8–13 µm) detection has long been the mitigation of dark current while achieving a high conversion efficiency of optical to electrical signals. Often overlooked is the bandwidth of detector response, despite several existing and expected future long-wave infrared high bandwidth applications. Here, we demonstrate ultra-fast response times in long-wave infrared detectors leveraging ultra-thin absorbers. The time response of the detectors is characterized using mid-infrared femtosecond pulses generated by an optical parametric amplifier, as a function of the device temperature and operating bias, as well as excitation wavelength. An equivalent circuit model for the detectors is presented and compared to our experimental results with excellent agreement. We demonstrate detector impulse response times of <100ps and 3 dB bandwidths in the GHz frequency range (f3dB > 3.5 GHz). Spectral response measurements confirm that the detectors have a resonant cavity mode enhanced response in the long-wave infrared, peaking at 10.2 µm. The presented detectors offer a potential solution for a range of high-frequency applications in the long-wave infrared.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/5.0181052

Cites

62 of 62 references verified0 citation errors · 0 not checkable

Statistics

Figures

Image 1
CC-BY · From the PDF
FIG. 1 (a) Ultra-thin detector schematics. (i) The effective band structure of the detector considering the band edge positions and energy gaps of the T2SL minibands in the contact, barrier, absorber, and n ++ ground plane, as well as a schematic of the electron-hole pair excitation and collection. (ii) Schematic of the LWIR T2SL band structure showing the valence (blue) and conduction (red) band edges of both constituent materials, as well as the lowest energy valence (blue) and conduction (red) band minibands. (b) Schematic of the as-grown layer stack, layer materials, and thicknesses, for the ultra-thin detector. (c) Normalized T = 77 K photoluminescence (black) and room temperature reflectivity (red) from the as-grown material.
FIG. 1 (a) Ultra-thin detector schematics. (i) The effective band structure of the detector considering the band edge positions and energy gaps of the T2SL minibands in the contact, barrier, absorber, and n ++ ground plane, as well as a schematic of the electron-hole pair excitation and collection. (ii) Schematic of the LWIR T2SL band structure showing the valence (blue) and conduction (red) band edges of both constituent materials, as well as the lowest energy valence (blue) and conduction (red) band minibands. (b) Schematic of the as-grown layer stack, layer materials, and thicknesses, for the ultra-thin detector. (c) Normalized T = 77 K photoluminescence (black) and room temperature reflectivity (red) from the as-grown material.CC-BY · From the PDF
FIG. 2 (a) Ultra-thin detector fabrication process flow schematics. (i) As-grown layer stack. (ii) Mesa definition by UV photolithography and citric and phosphoric acid wet etch. (iii) SiO2 backfill and photoresist lift-off. (iv) Second, planarizing SiO 2 deposition. (v) UV photolithography and reactive ion etch of SiO 2 aperture. (vi) UV photolithography, metal deposition, and lift-off for top and bottom contacts. (b) Optical micrograph of the fabricated detector. (c) Temperature-dependent current density vs voltage of fabricated devices. At low temperatures, the noise in the measurement is caused by the low dark current approaching the instrument noise floor.
FIG. 2 (a) Ultra-thin detector fabrication process flow schematics. (i) As-grown layer stack. (ii) Mesa definition by UV photolithography and citric and phosphoric acid wet etch. (iii) SiO2 backfill and photoresist lift-off. (iv) Second, planarizing SiO 2 deposition. (v) UV photolithography and reactive ion etch of SiO 2 aperture. (vi) UV photolithography, metal deposition, and lift-off for top and bottom contacts. (b) Optical micrograph of the fabricated detector. (c) Temperature-dependent current density vs voltage of fabricated devices. At low temperatures, the noise in the measurement is caused by the low dark current approaching the instrument noise floor.CC-BY · From the PDF
Image 4
CC-BY · From the PDF
FIG. 4 (a) Equivalent circuit model of the nBn detector and the external measurement circuit. (b) The simulated response fitting of the experimentally measured response of the D = 100 μ mdevice at 77 and 150 K. Only Rj , the time constant τ , and the amplitude of the current source I nBn are changed to represent the temperature change, which is sufficient to reproduce the observed negative time response signals.
FIG. 4 (a) Equivalent circuit model of the nBn detector and the external measurement circuit. (b) The simulated response fitting of the experimentally measured response of the D = 100 μ mdevice at 77 and 150 K. Only Rj , the time constant τ , and the amplitude of the current source I nBn are changed to represent the temperature change, which is sufficient to reproduce the observed negative time response signals.CC-BY · From the PDF
FIG. 5 [(a) and (b)] Fourier transform frequency spectra of the time response signals from the four devices with mesa sizes ranging from 100 to 20 μ m, under an applied bias of -0.5 V, at (a) 77 K and (b) 150 K, respectively. [(c) and (d)] 3-dB bandwidth extracted from the respective frequency spectra of the four devices, plotted as a function of the applied bias, at (c) 77 K and (d) 150 K, respectively.
FIG. 5 [(a) and (b)] Fourier transform frequency spectra of the time response signals from the four devices with mesa sizes ranging from 100 to 20 μ m, under an applied bias of -0.5 V, at (a) 77 K and (b) 150 K, respectively. [(c) and (d)] 3-dB bandwidth extracted from the respective frequency spectra of the four devices, plotted as a function of the applied bias, at (c) 77 K and (d) 150 K, respectively.CC-BY · From the PDF
FIG. 6 Normalized spectral response of the representative D = 100 μ m device, measured both with the FTIR and with the OPA. The FTIR spectra are obtained at both 77 and 150 K and normalized to their respective LWIR response peaks. The OPA spectrum is the extracted peak intensity of the response signals as a function of the OPA wavelength, normalized to the beam profile and photon energy at each wavelength, at the highest operating temperature tested (150 K) under an applied bias of -0.3 V.
FIG. 6 Normalized spectral response of the representative D = 100 μ m device, measured both with the FTIR and with the OPA. The FTIR spectra are obtained at both 77 and 150 K and normalized to their respective LWIR response peaks. The OPA spectrum is the extracted peak intensity of the response signals as a function of the OPA wavelength, normalized to the beam profile and photon energy at each wavelength, at the highest operating temperature tested (150 K) under an applied bias of -0.3 V.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 3

  1. 1. A. Rogalski, Infrared Detectors (CRC Press, 2000).
  2. 22. μm," Appl. Phys. Lett. 89, 061119 (2006).
  3. 58. R. T. Howe and C. G. Sodini, Microelectronics: An Integrated Approach (Prentice Hall Upper, Saddle River, NJ, 1997).

Cited by

See all 14

Metadata

Authors
Wang, Y., Muhowski, A. J., Nordin, L., Dev, S., Allen, M., Allen, J., & Wasserman, D.
Affiliations
  • The University of Texas at Austin (US)
  • Sandia National Laboratories (US)
  • University of Central Florida (US)
  • Eglin Air Force Base (US)
Corresponding author
Wasserman, Daniel
Venue
APL Photonics
Published
2024-01-01
Volume
9
Issue
1
ISSN
2378-0967 (ISSN-L)
OpenAlex
W4391377856
Cited by
13
References
62
Citations by year
2026: 7 · 2025: 2 · 2024: 4
FWCI
1.34
Type
journal article
Language
en
Open access
Licence
Locations
  • APL Photonics (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Air Force Office of Scientific Research (23RWCOR002)
  • University of Dayton Research Institute (RSC20061)
  • National Science Foundation (NNCI-202522, ECCS-1926187)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Semiconductor Detectors and Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
Keywords
ultrathin absorber, high-speed response, femtosecond pulse characterization, equivalent circuit model, resonant cavity modes, 3-dB bandwidth, dark current, mid-infrared detection, optical parametric amplifier

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.